Xiaodong Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaodong Cheng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Shuo Peng
Department of Bone Disease, Third Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, China
1 shared publication - Tao Wu
Department of Bone Disease, Third Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, China
1 shared publication - Xuejiao Ren
Department of Radiotherapy, Fourth Hospital of Hebei Medical University, Shijiazhuang, 050011, Hebei, China
1 shared publication - Yong-Tai Han
Hebei Med Univ, Hosp 3, Dept Bone Dis, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
1 shared publication - Yunwei Cui
Department of Trauma, Third Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, China
1 shared publication - Zhiyong Hou
Department of Orthopedic Surgery, Hebei Medical University Third Hospital
1 shared publication
Latest Publications
- Open Access
- 19 June 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 1-8
Biomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.
- 19 June 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 1-8
Open AccessBiomechanical study of three kinds of internal fixation for the treatment of sacroiliac joint disruption using biomechanical test and finite element analysis
To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.