Hermie J. Hermens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Hermie J. Hermens has a total of 197 co-authors. Here are the top co-authors by number of shared publications:
- Monique Tabak
University of Twente
21 shared publications - Lex van Velsen
Roessingh Research and Development
15 shared publications - Miriam M. R. Vollenbroek-Hutten
University of Twente
13 shared publications - Harm Op Den Akker
Health Group, Roessingh Research and Development, Enschede, The Netherlands
10 shared publications - Mathilde C. van Rossum
Biomedical Signals and Systems, University of Twente, Enschede, the Netherlands
8 shared publications - Bernhard Johannes Frederik van Beijnum
Department of Biomedical Signals and Systems, University of Twente, Enschede, The Netherlands
7 shared publications
Latest Publications
- Open Access
- 7 November 2026
- Published by Elsevier in Smart Health
Exploring the correlation between continuous wearable sensor data, emotional arousal and lifestyle: an observational study
- 7 November 2026
- Published by Elsevier in Smart Health
Open AccessExploring the correlation between continuous wearable sensor data, emotional arousal and lifestyle: an observational study
- Open Access
- 8 November 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e13723
Developing Game-Based Design for eHealth in Practice: 4-Phase Game Design Process
Background: Games are increasingly used in eHealth as a strategy for user engagement. There is an enormous diversity of end users and objectives targeted by eHealth. Hence, identifying game content that drives and sustains engagement is challenging. More openness in the game design process and motivational strategies could aid researchers and designers of future game-based apps. Objective: This study aims to provide insights into our approach to develop game-based eHealth in practice with a case study (Personalised ICT Supported Services for Independent Living and Active Ageing [PERSSILAA]). PERSSILAA is a self-management platform that aims to counter frailty by offering training modules to older adults in the domains of healthy nutrition and physical and cognitive training to maintain a healthy lifestyle. We elaborate on the entire game design process and show the motivational strategies applied. Methods: We introduce four game design phases in the process toward game-based eHealth: (1) end-user research, (2) conceptualization, (3) creative design, and (4) refinement (ie, prototyping and evaluations). Results: First, 168 participants participated in end-user research, resulting in an overview of their preferences for game content and a set of game design recommendations. We found that conventional games popular among older adults do not necessarily translate well into engaging concepts for eHealth. Recommendations include focusing game concepts on thinking, problem-solving, variation, discovery, and achievement and using high-quality aesthetics. Second, stakeholder sessions with development partners resulted in strategies for long-term engagement using indicators of user performance on the platform’s training modules. These performance indicators, for example, completed training sessions or exercises, form the basis for game progression. Third, results from prior phases were used in creative design to create the game “Stranded!” The user plays a person who is shipwrecked who must gather parts for a life raft by completing in-game objectives. Finally, iterative prototyping resulted in the final prototype of the game-based app. A total of 35 older adults participated using simulated training modules. End users scored appreciation (74/100), ease of use (73/100), expected effectivity and motivation (62/100), fun and pleasantness of using the app (75/100), and intended future use (66/100), which implies that the app is ready for use by a larger population. Conclusions: The study resulted in a game-based app for which the entire game design process within eHealth was transparently documented and where engagement strategies were based on extensive user research. Our user evaluations indicate that the strategies for long-term engagement led to game content that was perceived as engaging by older adults. As a next step, research is needed on the user experience and actual engagement with the game to support the self-management of older adults, followed by clinical studies on its added value.
- 8 November 2024
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 8 (1) , e13723
Open AccessDeveloping Game-Based Design for eHealth in Practice: 4-Phase Game Design Process
Background: Games are increasingly used in eHealth as a strategy for user engagement. There is an enormous diversity of end users and objectives targeted by eHealth. Hence, identifying game content that drives and sustains engagement is challenging. More openness in the game design process and motivational strategies could aid researchers and designers of future game-based apps. Objective: This study aims to provide insights into our approach to develop game-based eHealth in practice with a case study (Personalised ICT Supported Services for Independent Living and Active Ageing [PERSSILAA]). PERSSILAA is a self-management platform that aims to counter frailty by offering training modules to older adults in the domains of healthy nutrition and physical and cognitive training to maintain a healthy lifestyle. We elaborate on the entire game design process and show the motivational strategies applied. Methods: We introduce four game design phases in the process toward game-based eHealth: (1) end-user research, (2) conceptualization, (3) creative design, and (4) refinement (ie, prototyping and evaluations). Results: First, 168 participants participated in end-user research, resulting in an overview of their preferences for game content and a set of game design recommendations. We found that conventional games popular among older adults do not necessarily translate well into engaging concepts for eHealth. Recommendations include focusing game concepts on thinking, problem-solving, variation, discovery, and achievement and using high-quality aesthetics. Second, stakeholder sessions with development partners resulted in strategies for long-term engagement using indicators of user performance on the platform’s training modules. These performance indicators, for example, completed training sessions or exercises, form the basis for game progression. Third, results from prior phases were used in creative design to create the game “Stranded!” The user plays a person who is shipwrecked who must gather parts for a life raft by completing in-game objectives. Finally, iterative prototyping resulted in the final prototype of the game-based app. A total of 35 older adults participated using simulated training modules. End users scored appreciation (74/100), ease of use (73/100), expected effectivity and motivation (62/100), fun and pleasantness of using the app (75/100), and intended future use (66/100), which implies that the app is ready for use by a larger population. Conclusions: The study resulted in a game-based app for which the entire game design process within eHealth was transparently documented and where engagement strategies were based on extensive user research. Our user evaluations indicate that the strategies for long-term engagement led to game content that was perceived as engaging by older adults. As a next step, research is needed on the user experience and actual engagement with the game to support the self-management of older adults, followed by clinical studies on its added value.
- Open Access
- 31 July 2024
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 13 (1) , e50849
Consequences of Data Loss on Clinical Decision-Making in Continuous Glucose Monitoring: Retrospective Cohort Study
Background: The impact of missing data on individual continuous glucose monitoring (CGM) data is unknown but can influence clinical decision-making for patients. Objective: We aimed to investigate the consequences of data loss on glucose metrics in individual patient recordings from continuous glucose monitors and assess its implications on clinical decision-making. Methods: The CGM data were collected from patients with type 1 and 2 diabetes using the FreeStyle Libre sensor (Abbott Diabetes Care). We selected 7-28 days of 24 hours of continuous data without any missing values from each individual patient. To mimic real-world data loss, missing data ranging from 5% to 50% were introduced into the data set. From this modified data set, clinical metrics including time below range (TBR), TBR level 2 (TBR2), and other common glucose metrics were calculated in the data sets with and that without data loss. Recordings in which glucose metrics deviated relevantly due to data loss, as determined by clinical experts, were defined as expert panel boundary error (εEPB). These errors were expressed as a percentage of the total number of recordings. The errors for the recordings with glucose management indicator <53 mmol/mol were investigated. Results: A total of 84 patients contributed to 798 recordings over 28 days. With 5%-50% data loss for 7-28 days recordings, the εEPB varied from 0 out of 798 (0.0%) to 147 out of 736 (20.0%) for TBR and 0 out of 612 (0.0%) to 22 out of 408 (5.4%) recordings for TBR2. In the case of 14-day recordings, TBR and TBR2 episodes completely disappeared due to 30% data loss in 2 out of 786 (0.3%) and 32 out of 522 (6.1%) of the cases, respectively. However, the initial values of the disappeared TBR and TBR2 were relatively small (<0.1%). In the recordings with glucose management indicator <53 mmol/mol the εEPB was 9.6% for 14 days with 30% data loss. Conclusions: With a maximum of 30% data loss in 14-day CGM recordings, there is minimal impact of missing data on the clinical interpretation of various glucose metrics. Trial Registration: ClinicalTrials.gov NCT05584293; https://clinicaltrials.gov/study/NCT05584293
- 31 July 2024
- Published by JMIR Publications Inc. in Interactive Journal of Medical Research
- Vol. 13 (1) , e50849
Open AccessConsequences of Data Loss on Clinical Decision-Making in Continuous Glucose Monitoring: Retrospective Cohort Study
Background: The impact of missing data on individual continuous glucose monitoring (CGM) data is unknown but can influence clinical decision-making for patients. Objective: We aimed to investigate the consequences of data loss on glucose metrics in individual patient recordings from continuous glucose monitors and assess its implications on clinical decision-making. Methods: The CGM data were collected from patients with type 1 and 2 diabetes using the FreeStyle Libre sensor (Abbott Diabetes Care). We selected 7-28 days of 24 hours of continuous data without any missing values from each individual patient. To mimic real-world data loss, missing data ranging from 5% to 50% were introduced into the data set. From this modified data set, clinical metrics including time below range (TBR), TBR level 2 (TBR2), and other common glucose metrics were calculated in the data sets with and that without data loss. Recordings in which glucose metrics deviated relevantly due to data loss, as determined by clinical experts, were defined as expert panel boundary error (εEPB). These errors were expressed as a percentage of the total number of recordings. The errors for the recordings with glucose management indicator <53 mmol/mol were investigated. Results: A total of 84 patients contributed to 798 recordings over 28 days. With 5%-50% data loss for 7-28 days recordings, the εEPB varied from 0 out of 798 (0.0%) to 147 out of 736 (20.0%) for TBR and 0 out of 612 (0.0%) to 22 out of 408 (5.4%) recordings for TBR2. In the case of 14-day recordings, TBR and TBR2 episodes completely disappeared due to 30% data loss in 2 out of 786 (0.3%) and 32 out of 522 (6.1%) of the cases, respectively. However, the initial values of the disappeared TBR and TBR2 were relatively small (<0.1%). In the recordings with glucose management indicator <53 mmol/mol the εEPB was 9.6% for 14 days with 30% data loss. Conclusions: With a maximum of 30% data loss in 14-day CGM recordings, there is minimal impact of missing data on the clinical interpretation of various glucose metrics. Trial Registration: ClinicalTrials.gov NCT05584293; https://clinicaltrials.gov/study/NCT05584293
- Open Access
Missing Data Statistics Provide Causal Insights into Data Loss in Diabetes Health Monitoring by Wearable Sensors
Background: Data loss in wearable sensors is an inevitable problem that leads to misrepresentation during diabetes health monitoring. We systematically investigated missing wearable sensors data to get causal insight into the mechanisms leading to missing data. Methods: Two-week-long data from a continuous glucose monitor and a Fitbit activity tracker recording heart rate (HR) and step count in free-living patients with type 2 diabetes mellitus were used. The gap size distribution was fitted with a Planck distribution to test for missing not at random (MNAR) and a difference between distributions was tested with a Chi-squared test. Significant missing data dispersion over time was tested with the Kruskal–Wallis test and Dunn post hoc analysis. Results: Data from 77 subjects resulted in 73 cleaned glucose, 70 HR and 68 step count recordings. The glucose gap sizes followed a Planck distribution. HR and step count gap frequency differed significantly (p < 0.001), and the missing data were therefore MNAR. In glucose, more missing data were found in the night (23:00–01:00), and in step count, more at measurement days 6 and 7 (p < 0.001). In both cases, missing data were caused by insufficient frequency of data synchronization. Conclusions: Our novel approach of investigating missing data statistics revealed the mechanisms for missing data in Fitbit and CGM data.
Open AccessMissing Data Statistics Provide Causal Insights into Data Loss in Diabetes Health Monitoring by Wearable Sensors
Background: Data loss in wearable sensors is an inevitable problem that leads to misrepresentation during diabetes health monitoring. We systematically investigated missing wearable sensors data to get causal insight into the mechanisms leading to missing data. Methods: Two-week-long data from a continuous glucose monitor and a Fitbit activity tracker recording heart rate (HR) and step count in free-living patients with type 2 diabetes mellitus were used. The gap size distribution was fitted with a Planck distribution to test for missing not at random (MNAR) and a difference between distributions was tested with a Chi-squared test. Significant missing data dispersion over time was tested with the Kruskal–Wallis test and Dunn post hoc analysis. Results: Data from 77 subjects resulted in 73 cleaned glucose, 70 HR and 68 step count recordings. The glucose gap sizes followed a Planck distribution. HR and step count gap frequency differed significantly (p < 0.001), and the missing data were therefore MNAR. In glucose, more missing data were found in the night (23:00–01:00), and in step count, more at measurement days 6 and 7 (p < 0.001). In both cases, missing data were caused by insufficient frequency of data synchronization. Conclusions: Our novel approach of investigating missing data statistics revealed the mechanisms for missing data in Fitbit and CGM data.
- Open Access
- 30 August 2023
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 6 (1) , e44483
Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
Background: Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. Objective: This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms). Methods: Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR). Results: The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P<.004) compared with the control group (median 2.8, IQR 2.4-3.2). The alarm sensitivity of the hourly sensor EWSs was the highest (80%-67%) for thresholds of 3 to 5, which was associated with alarm rates of 2 (FDR=85%) to 1.2 (FDR=83%) alarms per patient per day respectively. The sensitivity of sensor EWS–based alarms was higher than that of nurse EWS–based alarms (maximum=40%) but lower than that of single-parameter alarms (87%) for all thresholds. In contrast, the (false) alarm rates of sensor EWS–based alarms were higher than that of nurse EWS–based alarms (maximum=0.6 alarm/patient/d; FDR=80%) but lower than that of single-parameter alarms (2 alarms/patient/d; FDR=84%) for most thresholds. Alarm rates for sensor EWSs increased for shorter time windows, reaching 70 alarms per patient per day when calculated every minute. Conclusions: EWSs obtained using wireless vital sign sensors may contribute to the early recognition of postoperative complications in a ward setting, with higher alarm sensitivity compared with manual EWS measurements. Although hourly sensor EWSs provide fewer alarms compared with single-parameter alarms, high false alarm rates can be expected when calculated over shorter time spans. Further studies are recommended to optimize care escalation criteria for continuous monitoring of vital signs in a ward setting and to evaluate the effects on patient outcomes.
- 30 August 2023
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 6 (1) , e44483
Open AccessEarly Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study
Background: Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. Objective: This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms). Methods: Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR). Results: The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P<.004) compared with the control group (median 2.8, IQR 2.4-3.2). The alarm sensitivity of the hourly sensor EWSs was the highest (80%-67%) for thresholds of 3 to 5, which was associated with alarm rates of 2 (FDR=85%) to 1.2 (FDR=83%) alarms per patient per day respectively. The sensitivity of sensor EWS–based alarms was higher than that of nurse EWS–based alarms (maximum=40%) but lower than that of single-parameter alarms (87%) for all thresholds. In contrast, the (false) alarm rates of sensor EWS–based alarms were higher than that of nurse EWS–based alarms (maximum=0.6 alarm/patient/d; FDR=80%) but lower than that of single-parameter alarms (2 alarms/patient/d; FDR=84%) for most thresholds. Alarm rates for sensor EWSs increased for shorter time windows, reaching 70 alarms per patient per day when calculated every minute. Conclusions: EWSs obtained using wireless vital sign sensors may contribute to the early recognition of postoperative complications in a ward setting, with higher alarm sensitivity compared with manual EWS measurements. Although hourly sensor EWSs provide fewer alarms compared with single-parameter alarms, high false alarm rates can be expected when calculated over shorter time spans. Further studies are recommended to optimize care escalation criteria for continuous monitoring of vital signs in a ward setting and to evaluate the effects on patient outcomes.
- Open Access
- 14 July 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Consequences of Data Loss on Clinical Decision-Making in Continuous Glucose Monitoring: Retrospective Cohort Study (Preprint)
BACKGROUND The impact of missing data on individual continuous glucose monitoring (CGM) data is unknown but can influence clinical decision-making for patients. OBJECTIVE We aimed to investigate the consequences of data loss on glucose metrics in individual patient recordings from continuous glucose monitors and assess its implications on clinical decision-making. METHODS The CGM data were collected from patients with type 1 and 2 diabetes using the FreeStyle Libre sensor (Abbott Diabetes Care). We selected 7-28 days of 24 hours of continuous data without any missing values from each individual patient. To mimic real-world data loss, missing data ranging from 5% to 50% were introduced into the data set. From this modified data set, clinical metrics including time below range (TBR), TBR level 2 (TBR2), and other common glucose metrics were calculated in the data sets with and that without data loss. Recordings in which glucose metrics deviated relevantly due to data loss, as determined by clinical experts, were defined as expert panel boundary error (εEPB). These errors were expressed as a percentage of the total number of recordings. The errors for the recordings with glucose management indicator <53 mmol/mol were investigated. RESULTS A total of 84 patients contributed to 798 recordings over 28 days. With 5%-50% data loss for 7-28 days recordings, the εEPB varied from 0 out of 798 (0.0%) to 147 out of 736 (20.0%) for TBR and 0 out of 612 (0.0%) to 22 out of 408 (5.4%) recordings for TBR2. In the case of 14-day recordings, TBR and TBR2 episodes completely disappeared due to 30% data loss in 2 out of 786 (0.3%) and 32 out of 522 (6.1%) of the cases, respectively. However, the initial values of the disappeared TBR and TBR2 were relatively small (<0.1%). In the recordings with glucose management indicator <53 mmol/mol the εEPB was 9.6% for 14 days with 30% data loss. CONCLUSIONS With a maximum of 30% data loss in 14-day CGM recordings, there is minimal impact of missing data on the clinical interpretation of various glucose metrics. CLINICALTRIAL ClinicalTrials.gov NCT05584293; https://clinicaltrials.gov/study/NCT05584293
- 14 July 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessConsequences of Data Loss on Clinical Decision-Making in Continuous Glucose Monitoring: Retrospective Cohort Study (Preprint)
BACKGROUND The impact of missing data on individual continuous glucose monitoring (CGM) data is unknown but can influence clinical decision-making for patients. OBJECTIVE We aimed to investigate the consequences of data loss on glucose metrics in individual patient recordings from continuous glucose monitors and assess its implications on clinical decision-making. METHODS The CGM data were collected from patients with type 1 and 2 diabetes using the FreeStyle Libre sensor (Abbott Diabetes Care). We selected 7-28 days of 24 hours of continuous data without any missing values from each individual patient. To mimic real-world data loss, missing data ranging from 5% to 50% were introduced into the data set. From this modified data set, clinical metrics including time below range (TBR), TBR level 2 (TBR2), and other common glucose metrics were calculated in the data sets with and that without data loss. Recordings in which glucose metrics deviated relevantly due to data loss, as determined by clinical experts, were defined as expert panel boundary error (εEPB). These errors were expressed as a percentage of the total number of recordings. The errors for the recordings with glucose management indicator <53 mmol/mol were investigated. RESULTS A total of 84 patients contributed to 798 recordings over 28 days. With 5%-50% data loss for 7-28 days recordings, the εEPB varied from 0 out of 798 (0.0%) to 147 out of 736 (20.0%) for TBR and 0 out of 612 (0.0%) to 22 out of 408 (5.4%) recordings for TBR2. In the case of 14-day recordings, TBR and TBR2 episodes completely disappeared due to 30% data loss in 2 out of 786 (0.3%) and 32 out of 522 (6.1%) of the cases, respectively. However, the initial values of the disappeared TBR and TBR2 were relatively small (<0.1%). In the recordings with glucose management indicator <53 mmol/mol the εEPB was 9.6% for 14 days with 30% data loss. CONCLUSIONS With a maximum of 30% data loss in 14-day CGM recordings, there is minimal impact of missing data on the clinical interpretation of various glucose metrics. CLINICALTRIAL ClinicalTrials.gov NCT05584293; https://clinicaltrials.gov/study/NCT05584293
- Open Access
- 19 April 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-4
HEROES, Design of an Exergame for Balance Recovery of Stroke Patients for a Home Environment
- 19 April 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-4
Open AccessHEROES, Design of an Exergame for Balance Recovery of Stroke Patients for a Home Environment
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Factors Influencing the Use of an Artificial Intelligence-Based App (SELFBACK) for Tailored Self-Management Support Among Adults with Neck and/or Low Back Pain
Objective: Tailored self-management support is recommended as first-line treatment for neck and low back pain. Using mHealth applications has been put forward as a promising way to provide such support. However, there is limited knowledge about factors influencing the engagement with app-delivered self-management interventions. The aim of this study was to assess barriers and facilitators for engaging with a self-management mHealth app among adults suffering from neck and/or low back pain. Methods: We carried out an observational cohort study among adults with neck and/or low back pain. The artificial intelligence-based SELFBACK app supports tailored self-management of neck and low back pain and was used by the participants for six weeks. After six weeks of use, participants were interviewed by phone. A deductive approach was used for analysing the barriers and facilitators. Results: Thirty-two adults (17 males) with neck and/or low back pain participated in this study (mean age=54.9 (SD=15.8)). Our results show that the mode of delivery (i.e. the way the intervention is delivered to the users (via smartphone)) and the novelty of the SELFBACK app were perceived most often as a barrier to use the app, and the action plans (i.e. weekly self-management recommendations) of the app and health-related factors (e.g. pain relief) were perceived most often as facilitating factors to use the app. Conclusions: This study provides strategies on how to improve an eHealth service, by tackling the barriers and incorporating the facilitators. Furthermore, our study shows that these adults are willing and ready to receive blended treatment.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessFactors Influencing the Use of an Artificial Intelligence-Based App (SELFBACK) for Tailored Self-Management Support Among Adults with Neck and/or Low Back Pain
Objective: Tailored self-management support is recommended as first-line treatment for neck and low back pain. Using mHealth applications has been put forward as a promising way to provide such support. However, there is limited knowledge about factors influencing the engagement with app-delivered self-management interventions. The aim of this study was to assess barriers and facilitators for engaging with a self-management mHealth app among adults suffering from neck and/or low back pain. Methods: We carried out an observational cohort study among adults with neck and/or low back pain. The artificial intelligence-based SELFBACK app supports tailored self-management of neck and low back pain and was used by the participants for six weeks. After six weeks of use, participants were interviewed by phone. A deductive approach was used for analysing the barriers and facilitators. Results: Thirty-two adults (17 males) with neck and/or low back pain participated in this study (mean age=54.9 (SD=15.8)). Our results show that the mode of delivery (i.e. the way the intervention is delivered to the users (via smartphone)) and the novelty of the SELFBACK app were perceived most often as a barrier to use the app, and the action plans (i.e. weekly self-management recommendations) of the app and health-related factors (e.g. pain relief) were perceived most often as facilitating factors to use the app. Conclusions: This study provides strategies on how to improve an eHealth service, by tackling the barriers and incorporating the facilitators. Furthermore, our study shows that these adults are willing and ready to receive blended treatment.
- Open Access
- 28 November 2022
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 5 (1) , e40815
Determining the Reliable Measurement Period for Preoperative Baseline Values With Telemonitoring Before Major Abdominal Surgery: Pilot Cohort Study
Background: Preoperative telemonitoring of vital signs, physical activity, and well-being might be able to optimize prehabilitation of the patient’s physical and mental condition prior to surgery, support setting alarms during in-hospital monitoring, and allow personalization of the postoperative recovery process. Objective: The primary aim of this study was to evaluate when and how long patients awaiting major abdominal surgery should be monitored to get reliable preoperative individual baseline values of heart rate (HR), daily step count, and patient-reported outcome measures (PROMs). The secondary aim was to describe the perioperative course of these measurements at home. Methods: In this observational single-center cohort study, patients used a wearable sensor during waking hours and reported PROMs (pain, anxiety, fatigue, nausea) on a tablet twice a day. Intraclass correlation coefficients (ICCs) were used to evaluate the reliability of mean values on 2 specific preoperative days (the first day of telemonitoring and the day before hospital admission) and randomly selected preoperative periods compared to individual reference values. Mean values of HR, step count, and PROMs per day were visualized in a boxplot from 14 days before hospital admission until 30 days after surgery. Results: A total of 16 patients were included in the data analyses. The ICCs of mean values on the first day of telemonitoring were 0.91 for HR, 0.71 for steps, and at least 0.86 for PROMs. The day before hospital admission showed reliability coefficients of 0.76 for HR, 0.71 for steps, and 0.92-0.99 for PROMs. ICC values of randomly selected measurement periods increased over the continuous period of time from 0.68 to 0.99 for HR and daily step counts. A lower bound of the 95% CI of at least 0.75 was determined after 3 days of measurements. The ICCs of randomly selected PROM measurements were 0.89-0.94. Visualization of mean values per day mainly showed variable preoperative daily step counts (median 2409, IQR 1735-4661 steps/day) and lower postoperative daily step counts (median 884, IQR 474-1605 steps/day). In addition, pain was visually reduced until 30 days after surgery at home. Conclusions: In this prospective pilot study, for patients awaiting major abdominal surgery, baseline values for HR and daily step count could be measured reliably by a wearable sensor worn for at least 3 consecutive days and PROMs during any preoperative day. No clear conclusions were drawn from the description of the perioperative course by showing mean values of HR, daily step count, and PROM values over time in the home situation.
- 28 November 2022
- Published by JMIR Publications Inc. in JMIR Perioperative Medicine
- Vol. 5 (1) , e40815
Open AccessDetermining the Reliable Measurement Period for Preoperative Baseline Values With Telemonitoring Before Major Abdominal Surgery: Pilot Cohort Study
Background: Preoperative telemonitoring of vital signs, physical activity, and well-being might be able to optimize prehabilitation of the patient’s physical and mental condition prior to surgery, support setting alarms during in-hospital monitoring, and allow personalization of the postoperative recovery process. Objective: The primary aim of this study was to evaluate when and how long patients awaiting major abdominal surgery should be monitored to get reliable preoperative individual baseline values of heart rate (HR), daily step count, and patient-reported outcome measures (PROMs). The secondary aim was to describe the perioperative course of these measurements at home. Methods: In this observational single-center cohort study, patients used a wearable sensor during waking hours and reported PROMs (pain, anxiety, fatigue, nausea) on a tablet twice a day. Intraclass correlation coefficients (ICCs) were used to evaluate the reliability of mean values on 2 specific preoperative days (the first day of telemonitoring and the day before hospital admission) and randomly selected preoperative periods compared to individual reference values. Mean values of HR, step count, and PROMs per day were visualized in a boxplot from 14 days before hospital admission until 30 days after surgery. Results: A total of 16 patients were included in the data analyses. The ICCs of mean values on the first day of telemonitoring were 0.91 for HR, 0.71 for steps, and at least 0.86 for PROMs. The day before hospital admission showed reliability coefficients of 0.76 for HR, 0.71 for steps, and 0.92-0.99 for PROMs. ICC values of randomly selected measurement periods increased over the continuous period of time from 0.68 to 0.99 for HR and daily step counts. A lower bound of the 95% CI of at least 0.75 was determined after 3 days of measurements. The ICCs of randomly selected PROM measurements were 0.89-0.94. Visualization of mean values per day mainly showed variable preoperative daily step counts (median 2409, IQR 1735-4661 steps/day) and lower postoperative daily step counts (median 884, IQR 474-1605 steps/day). In addition, pain was visually reduced until 30 days after surgery at home. Conclusions: In this prospective pilot study, for patients awaiting major abdominal surgery, baseline values for HR and daily step count could be measured reliably by a wearable sensor worn for at least 3 consecutive days and PROMs during any preoperative day. No clear conclusions were drawn from the description of the perioperative course by showing mean values of HR, daily step count, and PROM values over time in the home situation.
- Open Access
- 24 November 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Early Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study (Preprint)
BACKGROUND Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. OBJECTIVE This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms). METHODS Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR). RESULTS The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P<.004) compared with the control group (median 2.8, IQR 2.4-3.2). The alarm sensitivity of the hourly sensor EWSs was the highest (80%-67%) for thresholds of 3 to 5, which was associated with alarm rates of 2 (FDR=85%) to 1.2 (FDR=83%) alarms per patient per day respectively. The sensitivity of sensor EWS–based alarms was higher than that of nurse EWS–based alarms (maximum=40%) but lower than that of single-parameter alarms (87%) for all thresholds. In contrast, the (false) alarm rates of sensor EWS–based alarms were higher than that of nurse EWS–based alarms (maximum=0.6 alarm/patient/d; FDR=80%) but lower than that of single-parameter alarms (2 alarms/patient/d; FDR=84%) for most thresholds. Alarm rates for sensor EWSs increased for shorter time windows, reaching 70 alarms per patient per day when calculated every minute. CONCLUSIONS EWSs obtained using wireless vital sign sensors may contribute to the early recognition of postoperative complications in a ward setting, with higher alarm sensitivity compared with manual EWS measurements. Although hourly sensor EWSs provide fewer alarms compared with single-parameter alarms, high false alarm rates can be expected when calculated over shorter time spans. Further studies are recommended to optimize care escalation criteria for continuous monitoring of vital signs in a ward setting and to evaluate the effects on patient outcomes.
- 24 November 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEarly Warning Scores to Support Continuous Wireless Vital Sign Monitoring for Complication Prediction in Patients on Surgical Wards: Retrospective Observational Study (Preprint)
BACKGROUND Wireless vital sign sensors are increasingly being used to monitor patients on surgical wards. Although early warning scores (EWSs) are the current standard for the identification of patient deterioration in a ward setting, their usefulness for continuous monitoring is unknown. OBJECTIVE This study aimed to explore the usability and predictive value of high-rate EWSs obtained from continuous vital sign recordings for early identification of postoperative complications and compares the performance of a sensor-based EWS alarm system with manual intermittent EWS measurements and threshold alarms applied to individual vital sign recordings (single-parameter alarms). METHODS Continuous vital sign measurements (heart rate, respiratory rate, blood oxygen saturation, and axillary temperature) collected with wireless sensors in patients on surgical wards were used for retrospective simulation of EWSs (sensor EWSs) for different time windows (1-240 min), adopting criteria similar to EWSs based on manual vital signs measurements (nurse EWSs). Hourly sensor EWS measurements were compared between patients with (event group: 14/46, 30%) and without (control group: 32/46, 70%) postoperative complications. In addition, alarms were simulated for the sensor EWSs using a range of alarm thresholds (1-9) and compared with alarms based on nurse EWSs and single-parameter alarms. Alarm performance was evaluated using the sensitivity to predict complications within 24 hours, daily alarm rate, and false discovery rate (FDR). RESULTS The hourly sensor EWSs of the event group (median 3.4, IQR 3.1-4.1) was significantly higher (P<.004) compared with the control group (median 2.8, IQR 2.4-3.2). The alarm sensitivity of the hourly sensor EWSs was the highest (80%-67%) for thresholds of 3 to 5, which was associated with alarm rates of 2 (FDR=85%) to 1.2 (FDR=83%) alarms per patient per day respectively. The sensitivity of sensor EWS–based alarms was higher than that of nurse EWS–based alarms (maximum=40%) but lower than that of single-parameter alarms (87%) for all thresholds. In contrast, the (false) alarm rates of sensor EWS–based alarms were higher than that of nurse EWS–based alarms (maximum=0.6 alarm/patient/d; FDR=80%) but lower than that of single-parameter alarms (2 alarms/patient/d; FDR=84%) for most thresholds. Alarm rates for sensor EWSs increased for shorter time windows, reaching 70 alarms per patient per day when calculated every minute. CONCLUSIONS EWSs obtained using wireless vital sign sensors may contribute to the early recognition of postoperative complications in a ward setting, with higher alarm sensitivity compared with manual EWS measurements. Although hourly sensor EWSs provide fewer alarms compared with single-parameter alarms, high false alarm rates can be expected when calculated over shorter time spans. Further studies are recommended to optimize care escalation criteria for continuous monitoring of vital signs in a ward setting and to evaluate the effects on patient outcomes.