Pankaj Goyal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pankaj Goyal has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Valeria Pino
Novartis Argentina S.A, Buenos Aires, Argentina
1 shared publication Bjoern Holzhauer
Novartis Pharma AG, Basel, Switzerland
1 shared publication- Brian Ament
Novartis Pharmaceuticals Corporation, San Carlos, California, USA
1 shared publication Brian Kelly
IQVIA, Durham, United States of America
1 shared publicationFrancesc Calvo
Novartis Pharma AG, Basel, Switzerland
1 shared publicationGerald Bacher
Novartis Pharma AG, Basel, Switzerland
1 shared publication
Latest Publications
- 7 September 2020
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 56 (suppl 64)
Clinical feasibility study utilizing multi-sensor devices with the goal of developing remote monitoring digital health solutions for patients with asthma or COPD
Introduction: Using multi-sensor devices in large scale clinical trials may facilitate development of new digital health solutions for remote monitoring and care of patients. Choice of appropriate parameters and devices for use in such clinical trials poses significant technological and operational challenges. Aim: Conduct a technological, operational and clinical feasibility study to determine the most appropriate multi-sensor devices for use in large scale Asthma and COPD clinical trials Methods: Parameters of clinical relevance to monitor Asthma and COPD patients were shortlisted. Sensor devices were chosen based on required parameter coverage, regulatory status, scientific evidence and technological and operational feasibility. Sensor data was collected and analyzed from 29 patients (moderate to severe COPD or uncontrolled Asthma) in a 4-week observational clinical feasibility study. Results: Parameters with potential clinical relevance (inclusive of heart rate, oxygen saturation, respiratory rate, sleep, physical activity, lung function, FeNO, rescue medication use and environmental data) were assessed using the following devices: Philips Biosensor®, Biovotion®, ActiGraph®, GoSpiro®, NIOX VERO®, MDI Sensor (Propeller Health®) and Emfit® . Patient compliance, burden to patient, usability and data quality, varied between the sensor devices and between asthma and COPD patients. Conclusions: The key considerations for selection of digital sensors for large scale remote monitoring clinical trials are: type and severity of disease, clinically relevant parameters, burden to patient, usability and data-quality of devices.
- 7 September 2020
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 56 (suppl 64)
Clinical feasibility study utilizing multi-sensor devices with the goal of developing remote monitoring digital health solutions for patients with asthma or COPD
Introduction: Using multi-sensor devices in large scale clinical trials may facilitate development of new digital health solutions for remote monitoring and care of patients. Choice of appropriate parameters and devices for use in such clinical trials poses significant technological and operational challenges. Aim: Conduct a technological, operational and clinical feasibility study to determine the most appropriate multi-sensor devices for use in large scale Asthma and COPD clinical trials Methods: Parameters of clinical relevance to monitor Asthma and COPD patients were shortlisted. Sensor devices were chosen based on required parameter coverage, regulatory status, scientific evidence and technological and operational feasibility. Sensor data was collected and analyzed from 29 patients (moderate to severe COPD or uncontrolled Asthma) in a 4-week observational clinical feasibility study. Results: Parameters with potential clinical relevance (inclusive of heart rate, oxygen saturation, respiratory rate, sleep, physical activity, lung function, FeNO, rescue medication use and environmental data) were assessed using the following devices: Philips Biosensor®, Biovotion®, ActiGraph®, GoSpiro®, NIOX VERO®, MDI Sensor (Propeller Health®) and Emfit® . Patient compliance, burden to patient, usability and data quality, varied between the sensor devices and between asthma and COPD patients. Conclusions: The key considerations for selection of digital sensors for large scale remote monitoring clinical trials are: type and severity of disease, clinically relevant parameters, burden to patient, usability and data-quality of devices.
- Open Access
- 14 June 2018
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 18 (1) , 100
Comparison of peak inspiratory flow rate via the Breezhaler®, Ellipta® and HandiHaler® dry powder inhalers in patients with moderate to very severe COPD: a randomized cross-over trial
The chronic and progressive nature of chronic obstructive pulmonary disease (COPD) requires self-administration of inhaled medication. Dry powder inhalers (DPIs) are increasingly being used for inhalation therapy in COPD. Important considerations when selecting DPIs include inhalation effort required and flow rates achieved by patients. Here, we present the comparison of the peak inspiratory flow rate (PIF) values achieved by COPD patients, with moderate to very severe airflow limitation, through the Breezhaler®, the Ellipta® and the HandiHaler® inhalers. The effects of disease severity, age and gender on PIF rate were also evaluated. This randomized, open-label, multicenter, cross-over, Phase IV study recruited patients with moderate to very severe airflow limitation (Global Initiative for Obstructive Lung Disease 2014 strategy), aged ≥40 years and having a smoking history of ≥10 pack years. No active drug or placebo was administered during the study. The inhalation profiles were recorded using inhalers fitted with a pressure tap and transducer at the wall of the mouthpiece. For each patient, the inhalation with the highest PIF value, out of three replicate inhalations per device, was selected for analysis. A paired t-test was performed to compare mean PIFs between each combination of devices. In total, 97 COPD patients were enrolled and completed the study. The highest mean PIF value (L/min ± SE) was observed with the Breezhaler® (108 ± 23), followed by the Ellipta® (78 ± 15) and the HandiHaler® (49 ± 9) inhalers and the lowest mean pressure drop values were recorded with the Breezhaler® inhaler, followed by the Ellipta® inhaler and the HandiHaler® inhaler, in the overall patient population. A similar trend was consistently observed in patients across all subgroups of COPD severity, within all age groups and for both genders. Patients with COPD were able to inhale with the least inspiratory effort and generate the highest mean PIF value through the Breezhaler® inhaler when compared with the Ellipta® and the HandiHaler® inhalers. These results were similar irrespective of patients’ COPD severity, age or gender. The trial was registered with ClinicalTrials.gov NCT02596009 on 4 November 2015.
- 14 June 2018
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 18 (1) , 100
Open AccessComparison of peak inspiratory flow rate via the Breezhaler®, Ellipta® and HandiHaler® dry powder inhalers in patients with moderate to very severe COPD: a randomized cross-over trial
The chronic and progressive nature of chronic obstructive pulmonary disease (COPD) requires self-administration of inhaled medication. Dry powder inhalers (DPIs) are increasingly being used for inhalation therapy in COPD. Important considerations when selecting DPIs include inhalation effort required and flow rates achieved by patients. Here, we present the comparison of the peak inspiratory flow rate (PIF) values achieved by COPD patients, with moderate to very severe airflow limitation, through the Breezhaler®, the Ellipta® and the HandiHaler® inhalers. The effects of disease severity, age and gender on PIF rate were also evaluated. This randomized, open-label, multicenter, cross-over, Phase IV study recruited patients with moderate to very severe airflow limitation (Global Initiative for Obstructive Lung Disease 2014 strategy), aged ≥40 years and having a smoking history of ≥10 pack years. No active drug or placebo was administered during the study. The inhalation profiles were recorded using inhalers fitted with a pressure tap and transducer at the wall of the mouthpiece. For each patient, the inhalation with the highest PIF value, out of three replicate inhalations per device, was selected for analysis. A paired t-test was performed to compare mean PIFs between each combination of devices. In total, 97 COPD patients were enrolled and completed the study. The highest mean PIF value (L/min ± SE) was observed with the Breezhaler® (108 ± 23), followed by the Ellipta® (78 ± 15) and the HandiHaler® (49 ± 9) inhalers and the lowest mean pressure drop values were recorded with the Breezhaler® inhaler, followed by the Ellipta® inhaler and the HandiHaler® inhaler, in the overall patient population. A similar trend was consistently observed in patients across all subgroups of COPD severity, within all age groups and for both genders. Patients with COPD were able to inhale with the least inspiratory effort and generate the highest mean PIF value through the Breezhaler® inhaler when compared with the Ellipta® and the HandiHaler® inhalers. These results were similar irrespective of patients’ COPD severity, age or gender. The trial was registered with ClinicalTrials.gov NCT02596009 on 4 November 2015.