Haoming Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haoming Lin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Siping Chen
National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, Guangdong China
2 shared publications - Xin Chen
College of Art and Design, Division of Arts, Shenzhen University
2 shared publications - Lingyao Yu
Guilin University of Electronic Technology
1 shared publication - Mian Chen
Shenzhen University Medical School, Shenzhen University
1 shared publication - Ming Dai
Shenzhen Polytechnic University, Shenzhen, China
1 shared publication - Pengpeng Zhang
School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
A 2D Magneto-Acousto-Electrical Tomography Method to Detect Conductivity Variation Using Multifocus Image Method
As magneto-acoustic-electrical tomography (MAET) combines the merits of high contrast and high imaging resolution, and is extremely useful for electrical conductivity measurement, so it is expected to be a promising medical imaging modalities for diagnosis of early-stage cancer. Based on the Verasonics system and the MC600 displacement platform, we designed and implemented a MAET system with a chirp pulse stimulation (MAET-CPS) method and a focal probe was utilized for stepscan focus excitation to enhance the imaging resolution. The relevant experiments were conducted to explore the influence of excitation positions of the single-focus point, and the effect of the excitation position on the amplitudes of the conductivity variation was clearly demonstrated. In order to take advantage of the merits of multifocus imaging, we firstly proposed a single focus MAET system with a chirp pulse stimulation (sfMAET-CPS) method and a multifocus MAET system with a chirp pulse stimulation (mfMAET-CPS) method for high-resolution conductivity imaging, and a homogenous gelatin phantom with a cuboid-shaped hole was used to investigate the accuracy of mfMAET-CPS. Comparative experiments were carried out on the same uniform phantom by the sfMAET-CPS and the mfMAET-CPS, respectively. The results showed that: (1) the electrical conductivity distributions of the homogenous phantom with a cuboid-shaped hole were detected by the sfMAET-CPS but were easily affected by the focal point, which demonstrated that the sfMAET-CPS had a low imaging resolution. (2) Compared with the sfMAET-CPS, the imaging effect of the mfMAET-CPS was much better than that of the sfMAET-CPS. (3) A linear interpolation algorithm was used to process the 2D conductivity distribution; it increased the smoothness of the conductivity distribution and improved the imaging effect. The stepscan focus excitation and the linearly frequency-modulated theory provide an alternative scheme for the clinical application of MAET.
Open AccessA 2D Magneto-Acousto-Electrical Tomography Method to Detect Conductivity Variation Using Multifocus Image Method
As magneto-acoustic-electrical tomography (MAET) combines the merits of high contrast and high imaging resolution, and is extremely useful for electrical conductivity measurement, so it is expected to be a promising medical imaging modalities for diagnosis of early-stage cancer. Based on the Verasonics system and the MC600 displacement platform, we designed and implemented a MAET system with a chirp pulse stimulation (MAET-CPS) method and a focal probe was utilized for stepscan focus excitation to enhance the imaging resolution. The relevant experiments were conducted to explore the influence of excitation positions of the single-focus point, and the effect of the excitation position on the amplitudes of the conductivity variation was clearly demonstrated. In order to take advantage of the merits of multifocus imaging, we firstly proposed a single focus MAET system with a chirp pulse stimulation (sfMAET-CPS) method and a multifocus MAET system with a chirp pulse stimulation (mfMAET-CPS) method for high-resolution conductivity imaging, and a homogenous gelatin phantom with a cuboid-shaped hole was used to investigate the accuracy of mfMAET-CPS. Comparative experiments were carried out on the same uniform phantom by the sfMAET-CPS and the mfMAET-CPS, respectively. The results showed that: (1) the electrical conductivity distributions of the homogenous phantom with a cuboid-shaped hole were detected by the sfMAET-CPS but were easily affected by the focal point, which demonstrated that the sfMAET-CPS had a low imaging resolution. (2) Compared with the sfMAET-CPS, the imaging effect of the mfMAET-CPS was much better than that of the sfMAET-CPS. (3) A linear interpolation algorithm was used to process the 2D conductivity distribution; it increased the smoothness of the conductivity distribution and improved the imaging effect. The stepscan focus excitation and the linearly frequency-modulated theory provide an alternative scheme for the clinical application of MAET.
- Open Access
- 13 June 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 75
Noninvasive assessment of age-related stiffness of crystalline lenses in a rabbit model using ultrasound elastography
The pathological or physiological changes of a crystalline lens directly affect the eye accommodation and transmittance, and then they increase the risk of presbyopia and cataracts for people in the middle and old age groups. There is no universally accepted quantitative method to measure the lens' mechanical properties in vivo so far. This study aims to investigate the possibility of assessing the age-related stiffness change of crystalline lens by acoustic-radiation-force-based ultrasound elastography (ARF-USE) in a rabbit model in vivo. There were 13 New Zealand white rabbits that were divided into four groups and fed normally until they were 60 (n = 4), 90 (n = 2), 120 (n = 4), and 150 (n = 3) days old, respectively. An ARF-USE platform was built based on the Verasonics™ Vantage 256 system. The shear waves were excited and traced in the lens by a linear ultrasound probe after a rabbit was anaesthetized. The average group velocities were 1.38 ± 0.2 m/s, 2.06 ± 0.3 m/s, 2.07 ± 0.29 m/s, and 2.30 ± 0.28 m/s, respectively, for the four groups of rabbits. The results shows that the group velocity has a strong correlation with the day age (r = 0.84, p < 1 × 10−7) and the weight (r = 0.83, p < 1×10−7) of the rabbits while the maximum displacement has no correlations with the day age (r = 0.27, p > 0.1) and the weight (r = 0.32, p > 0.1). This study demonstrated that the group velocity measured by ARF-USE had a strong correlation with age-related stiffness in a rabbit model, suggesting that group velocity is a good biomarker to characterize the stiffness of a crystalline lens. This study also demonstrated the feasibility of using this USE technique to assess the mechanical properties of the lens in vivo for clinical or research purposes.
- 13 June 2018
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 17 (1) , 75
Open AccessNoninvasive assessment of age-related stiffness of crystalline lenses in a rabbit model using ultrasound elastography
The pathological or physiological changes of a crystalline lens directly affect the eye accommodation and transmittance, and then they increase the risk of presbyopia and cataracts for people in the middle and old age groups. There is no universally accepted quantitative method to measure the lens' mechanical properties in vivo so far. This study aims to investigate the possibility of assessing the age-related stiffness change of crystalline lens by acoustic-radiation-force-based ultrasound elastography (ARF-USE) in a rabbit model in vivo. There were 13 New Zealand white rabbits that were divided into four groups and fed normally until they were 60 (n = 4), 90 (n = 2), 120 (n = 4), and 150 (n = 3) days old, respectively. An ARF-USE platform was built based on the Verasonics™ Vantage 256 system. The shear waves were excited and traced in the lens by a linear ultrasound probe after a rabbit was anaesthetized. The average group velocities were 1.38 ± 0.2 m/s, 2.06 ± 0.3 m/s, 2.07 ± 0.29 m/s, and 2.30 ± 0.28 m/s, respectively, for the four groups of rabbits. The results shows that the group velocity has a strong correlation with the day age (r = 0.84, p < 1 × 10−7) and the weight (r = 0.83, p < 1×10−7) of the rabbits while the maximum displacement has no correlations with the day age (r = 0.27, p > 0.1) and the weight (r = 0.32, p > 0.1). This study demonstrated that the group velocity measured by ARF-USE had a strong correlation with age-related stiffness in a rabbit model, suggesting that group velocity is a good biomarker to characterize the stiffness of a crystalline lens. This study also demonstrated the feasibility of using this USE technique to assess the mechanical properties of the lens in vivo for clinical or research purposes.