GCGarnett B. Cross

Garnett B. Cross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Garnett B. Cross has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Thermodynamic scaling of growth and defect activation in inn PA-MOCVD

    by Zaheer Ahmad, Osama A Rana, Shakeel Ahmad, Mark Vernon, Brendan Cross, Alexander Kozhanov

    Defect related disorder during InN growth is a major challenge for high performance electronic and optoelectronic devices. Film quality is often described using reactor specific settings instead of general physical variables. We test whether plasma assisted MOCVD (PA-MOCVD) growth of InN can be described using a single thermodynamic driving force coordinate. We build a driving force coordinate from the process conditions and use it to organize growth kinetics, defect sensitive Raman response, and structural coherence across different growth conditions. A kinetic Monte Carlo (KMC) model with driving force biased incorporation and defect activation events is used to test the proposed mechanism. When plotted against this coordinate, the incorporation rate follows an activated trend with a clear kinetic scale. Raman measurements show a crossover between a defect sparse and a defect rich regime: a disorder activated metric increases rapidly beyond the onset, while an A1-LO control metric stays statistically invariant. This suggests that short range lattice disorder, rather than long range polar coupling, dominates defect activation. X-ray diffraction shows that the out of plane coherence length is similar for samples that share the same driving force, even when their reactor settings differ. The KMC model reproduces the observed exponential trends and the two regimes. A single driving force coordinate brings together growth kinetics, defect activation, and structural coherence in PA-MOCVD InN, and offers a practical way to identify and reach defect sparse growth conditions.

  • Open Access

    Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

    by M. K. Indika Senevirathna, Mark Vernon, Graham A. Cooke, Garnett B. Cross, Alexander Kozhanov, Michael D. Williams

    The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.


  • Analysis of useful ion yield for the Mg dopant in GaN by quadrupole—SIMS

    by M. K. Indika Senevirathna, Michael D. Williams, Graham A. Cooke, Alexander Kozhanov, Mark Vernon, Garnett B. Cross

    The authors present a quantitative secondary ion mass spectrometry (SIMS) analysis of the useful ion yield of magnesium dopant in a gallium nitride matrix. A quadrupole SIMS instrument was used to analyze an Mg-doped GaN sample grown by metal organic chemical vapor deposition. Oxygen (O2+) was used as the primary ion beam and its energy was varied in the range from 0.5 to 5 kV with and without oxygen flooding near the sample. The results of the analysis can be used to determine the primary beam energies for optimal magnesium sensitivity.