Catherine Hegarty
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Catherine Hegarty has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- James Davis
School of Engineering, Ulster University, Belfast, UK
5 shared publications - Stephen McKillop
School of Engineering, Ulster University, Jordanstown, U.K.
2 shared publications - Aaron McConville
School of Engineering, Ulster University, Jordanstown, Northern Ireland, BT37 0QB, UK
1 shared publication Amy Devine
School of Engineering, Ulster University, Belfast, U.K.
1 shared publication- Amy Devine
School of Engineering, Ulster University, Jordanstown BT37 0QB, Northern Ireland, UK
1 shared publication - Ashish Mathur
Centre for Interdisciplinary Research and Innovation (CIDRI), University of Petroleum and Energy Studies, Dehradun 248007, India
1 shared publication
Latest Publications
- 15 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (3) , 1-4
Conductive Composite Microneedle Sensors Based on Cellulose Acetate Phthalate: Investigating Performance and Biodegradability
Conductive microneedle patches based on carbon nanoparticle composites in which cellulose acetate phthalate (CAP) or polystyrene (PS) acted as a binder were investigated. The electrochemical properties of the composite system were assessed using ferrocyanide as a redox probe and compared to screen printed carbon electrodes. Preliminary investigations of biodegradability were conducted with the influence of soil interment assessed by electron microscopy. While the PS microneedles exhibited no breakdown, the CAP systems were found to be substantially degraded after 1 week with complete removal of the needle tips and hence piercing capability.
- 15 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (3) , 1-4
Conductive Composite Microneedle Sensors Based on Cellulose Acetate Phthalate: Investigating Performance and Biodegradability
Conductive microneedle patches based on carbon nanoparticle composites in which cellulose acetate phthalate (CAP) or polystyrene (PS) acted as a binder were investigated. The electrochemical properties of the composite system were assessed using ferrocyanide as a redox probe and compared to screen printed carbon electrodes. Preliminary investigations of biodegradability were conducted with the influence of soil interment assessed by electron microscopy. While the PS microneedles exhibited no breakdown, the CAP systems were found to be substantially degraded after 1 week with complete removal of the needle tips and hence piercing capability.
- Open Access
Minimising Blood Stream Infection: Developing New Materials for Intravascular Catheters
Catheter related blood stream infection is an ever present hazard for those patients requiring venous access and particularly for those requiring long term medication. The implementation of more rigorous care bundles and greater adherence to aseptic techniques have yielded substantial reductions in infection rates but the latter is still far from acceptable and continues to place a heavy burden on patients and healthcare providers. While advances in engineering design and the arrival of functional materials hold considerable promise for the development of a new generation of catheters, many challenges remain. The aim of this review is to identify the issues that presently impact catheter performance and provide a critical evaluation of the design considerations that are emerging in the pursuit of these new catheter systems.
Open AccessMinimising Blood Stream Infection: Developing New Materials for Intravascular Catheters
Catheter related blood stream infection is an ever present hazard for those patients requiring venous access and particularly for those requiring long term medication. The implementation of more rigorous care bundles and greater adherence to aseptic techniques have yielded substantial reductions in infection rates but the latter is still far from acceptable and continues to place a heavy burden on patients and healthcare providers. While advances in engineering design and the arrival of functional materials hold considerable promise for the development of a new generation of catheters, many challenges remain. The aim of this review is to identify the issues that presently impact catheter performance and provide a critical evaluation of the design considerations that are emerging in the pursuit of these new catheter systems.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 3 (9) , 1-4
Composite Microneedle Arrays Modified With Palladium Nanoclusters for Electrocatalytic Detection of Peroxide
The fabrication of conductive composite microneedle (MN) patches modified with palladium clusters for the electrocatalytic detection of peroxide is described in this letter. Micromolding techniques are utilized in which carbon nanoparticles are bound within a polystyrene matrix resulting in the production of a 10 × 10 array of needles of length 700 μm. Electrochemical anodization of the carbon particles increases the interfacial carboxyl group population which facilitates the capture of Pd 2+ ions. Their subsequent electroreduction yields a catalytic interface with a high sensitivity toward the electroreduction of peroxide (-0.3 V:49.7+/-2.8 μA·mM -1 ·cm -2 ; -0.5 V:102.1+/-2.32 μA·mM -1 ·cm -2 ). The MN sensing system and the various modification stages has been characterized using mechanical testing (fracture testing), cyclic voltammetry, and high-resolution X-ray photoelectron spectroscopy.
- 21 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 3 (9) , 1-4
Composite Microneedle Arrays Modified With Palladium Nanoclusters for Electrocatalytic Detection of Peroxide
The fabrication of conductive composite microneedle (MN) patches modified with palladium clusters for the electrocatalytic detection of peroxide is described in this letter. Micromolding techniques are utilized in which carbon nanoparticles are bound within a polystyrene matrix resulting in the production of a 10 × 10 array of needles of length 700 μm. Electrochemical anodization of the carbon particles increases the interfacial carboxyl group population which facilitates the capture of Pd 2+ ions. Their subsequent electroreduction yields a catalytic interface with a high sensitivity toward the electroreduction of peroxide (-0.3 V:49.7+/-2.8 μA·mM -1 ·cm -2 ; -0.5 V:102.1+/-2.32 μA·mM -1 ·cm -2 ). The MN sensing system and the various modification stages has been characterized using mechanical testing (fracture testing), cyclic voltammetry, and high-resolution X-ray photoelectron spectroscopy.
- Open Access
- 30 April 2019
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (15) , 10705-10714
Microneedle array sensors based on carbon nanoparticle composites: interfacial chemistry and electroanalytical properties
- 30 April 2019
- Published by Springer Nature in Journal of Materials Science
- Vol. 54 (15) , 10705-10714
Open AccessMicroneedle array sensors based on carbon nanoparticle composites: interfacial chemistry and electroanalytical properties
- Open Access
Mini-Review: Assessing the Potential Impact of Microneedle Technologies on Home Healthcare Applications
The increasing devolution of healthcare towards community care has meant that the management of many conditions is conducted within the home either by community nurses or by the patients themselves. The administration of medicines within home healthcare scenarios can however be problematic—especially when considering the delivery of medicines through injection. The possibility of needlestick injury (NSI) has become an ever-present hazard within healthcare settings, with a significant proportion of percutaneous injuries occurring during the handling and disposal of the needle. The emergence of transdermal microneedle systems, however, offers a potentially revolutionary advance and could dramatically improve safety—particularly within home healthcare where there are mounting concerns over the use and disposal of sharps. A mini-review of the advantages proffered by microneedle drug delivery technologies is presented and the potential impact on delivery of medicines within the home is critically appraised.
Open AccessMini-Review: Assessing the Potential Impact of Microneedle Technologies on Home Healthcare Applications
The increasing devolution of healthcare towards community care has meant that the management of many conditions is conducted within the home either by community nurses or by the patients themselves. The administration of medicines within home healthcare scenarios can however be problematic—especially when considering the delivery of medicines through injection. The possibility of needlestick injury (NSI) has become an ever-present hazard within healthcare settings, with a significant proportion of percutaneous injuries occurring during the handling and disposal of the needle. The emergence of transdermal microneedle systems, however, offers a potentially revolutionary advance and could dramatically improve safety—particularly within home healthcare where there are mounting concerns over the use and disposal of sharps. A mini-review of the advantages proffered by microneedle drug delivery technologies is presented and the potential impact on delivery of medicines within the home is critically appraised.