Li Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Li Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Wei Chen
Department of Ophthalmology, Tianjin Eye Hospital, Nankai University Affiliated Eye Hospital, Clinical College of Ophthalmology, Tianjin, 300020, PR China; Tianjin Medical University, Tianjin Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin, 300070, PR China
2 shared publications - Hongyuan Zhang
Department of Gynecology, Tianjin central Hospital of Obstetrics and Gynecology, Tianjin, China
1 shared publication Mei Han
Tianjin Key Laboratory of Ophthalmology and Vision Science, Tianjin Eye Hospital, Tianjin 300020, P.R. China
1 shared publication- Mei Han
Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin, China
1 shared publication Wei Chen
Tianjin Key Laboratory of Ophthalmology and Vision Science, Tianjin Eye Hospital, Tianjin 300020, P.R. China
1 shared publication- Xu Chen
Tianjin Central Hospital of Gynecology and Obstetrics, Tianjin, China
1 shared publication
Latest Publications
- Open Access
- 22 October 2025
- Published by Spandidos Publications in Biomedical Reports
- Vol. 23 (6) , 1-12
Systematic review and meta‑analysis of risk prediction models for retinopathy of prematurity in preterm infants
Retinopathy of prematurity (ROP) is a proliferative vascular disease affecting preterm infants with incompletely developed retinal vasculature, characterized by abnormal vascular proliferation that can lead to retinal detachment and blindness. Given its impact on neonatal visual health, developing reliable risk prediction models for ROP has become crucial for optimizing clinical screening and intervention strategies. However, existing models exhibit substantial heterogeneity in methodology, validation, and performance, limiting their generalizability across diverse clinical settings. The present study aimed to evaluate and summarize the effectiveness of existing ROP risk prediction models in preterm infants through a systematic review and meta‑analysis, with the goal of providing reliable clinical screening tools based on effectiveness metrics. A systematic search was conducted across PubMed, Cochrane Library, Web of Science and Embase databases using a strategy that combined MeSH terms and free‑text words to identify literature associated with risk prediction models for ROP in preterm infants. The risk of bias was assessed using the PROBAST tool. Statistical analysis involved data synthesis, heterogeneity testing, subgroup and sensitivity analyses, and publication bias assessment. A total of 492 relevant articles were retrieved; following deduplication and screening, 28 articles involving ROP risk prediction models were included. The included studies were published between 2009 and 2025, with sample sizes ranging from 90 to 22,569 participants, and a total sample size of 72,991. A total of 16 studies did not specify the validation method, five conducted external validation, two performed both internal and external validation, and five performed only internal validation. PROBAST assessment revealed that all included models had a moderate risk of bias, primarily attributed to the retrospective nature of the study design, inconsistent variable measurement and inadequate control of confounding factors. Meta‑analysis showed that the pooled area under the receiver operating characteristic curve (AUC) was 0.87 (95% CI: 0.34; 0.99), indicating good discriminative ability of the models. However, significant heterogeneity was observed (I²=99.2%, P<0.05). Subgroup analysis by model type demonstrated significant heterogeneity in both traditional statistical (I²=92.2%) and machine learning models (I²=97.3%). Subgroup analysis by study region showed no significant heterogeneity in studies from South America (I²=0%), while high heterogeneity was found in studies from Asia and North America + Europe (I²=96.6 and 93.6%, respectively). This may be associated with cross‑regional differences in population characteristics (such as ethnicity and disease spectra) and variations in medical standards. Funnel plot and Peters' bias test indicated high reliability of the overall study conclusions, and the results of the sensitivity analysis were stable. However, some studies had small sample sizes and single‑center designs, leading to selection bias. Additionally, multiple studies lacked model validation, and samples were limited to specific regions, failing to cover diverse healthcare settings and ethnic groups. In conclusion, current ROP risk prediction models for preterm infants exhibit good clinical application potential, with certain discriminative and predictive abilities, which can provide references for clinical screening. However, the risk of bias and insufficient validation limit their generalization ability. Future studies should expand sample sizes through prospective designs, strengthen external validation and optimize model development to improve prediction accuracy and universality, addressing the identified risks of bias and limited generalizability.
- 22 October 2025
- Published by Spandidos Publications in Biomedical Reports
- Vol. 23 (6) , 1-12
Open AccessSystematic review and meta‑analysis of risk prediction models for retinopathy of prematurity in preterm infants
Retinopathy of prematurity (ROP) is a proliferative vascular disease affecting preterm infants with incompletely developed retinal vasculature, characterized by abnormal vascular proliferation that can lead to retinal detachment and blindness. Given its impact on neonatal visual health, developing reliable risk prediction models for ROP has become crucial for optimizing clinical screening and intervention strategies. However, existing models exhibit substantial heterogeneity in methodology, validation, and performance, limiting their generalizability across diverse clinical settings. The present study aimed to evaluate and summarize the effectiveness of existing ROP risk prediction models in preterm infants through a systematic review and meta‑analysis, with the goal of providing reliable clinical screening tools based on effectiveness metrics. A systematic search was conducted across PubMed, Cochrane Library, Web of Science and Embase databases using a strategy that combined MeSH terms and free‑text words to identify literature associated with risk prediction models for ROP in preterm infants. The risk of bias was assessed using the PROBAST tool. Statistical analysis involved data synthesis, heterogeneity testing, subgroup and sensitivity analyses, and publication bias assessment. A total of 492 relevant articles were retrieved; following deduplication and screening, 28 articles involving ROP risk prediction models were included. The included studies were published between 2009 and 2025, with sample sizes ranging from 90 to 22,569 participants, and a total sample size of 72,991. A total of 16 studies did not specify the validation method, five conducted external validation, two performed both internal and external validation, and five performed only internal validation. PROBAST assessment revealed that all included models had a moderate risk of bias, primarily attributed to the retrospective nature of the study design, inconsistent variable measurement and inadequate control of confounding factors. Meta‑analysis showed that the pooled area under the receiver operating characteristic curve (AUC) was 0.87 (95% CI: 0.34; 0.99), indicating good discriminative ability of the models. However, significant heterogeneity was observed (I²=99.2%, P<0.05). Subgroup analysis by model type demonstrated significant heterogeneity in both traditional statistical (I²=92.2%) and machine learning models (I²=97.3%). Subgroup analysis by study region showed no significant heterogeneity in studies from South America (I²=0%), while high heterogeneity was found in studies from Asia and North America + Europe (I²=96.6 and 93.6%, respectively). This may be associated with cross‑regional differences in population characteristics (such as ethnicity and disease spectra) and variations in medical standards. Funnel plot and Peters' bias test indicated high reliability of the overall study conclusions, and the results of the sensitivity analysis were stable. However, some studies had small sample sizes and single‑center designs, leading to selection bias. Additionally, multiple studies lacked model validation, and samples were limited to specific regions, failing to cover diverse healthcare settings and ethnic groups. In conclusion, current ROP risk prediction models for preterm infants exhibit good clinical application potential, with certain discriminative and predictive abilities, which can provide references for clinical screening. However, the risk of bias and insufficient validation limit their generalization ability. Future studies should expand sample sizes through prospective designs, strengthen external validation and optimize model development to improve prediction accuracy and universality, addressing the identified risks of bias and limited generalizability.
- Open Access
- 6 June 2022
- Published by Springer Nature in BMC Ophthalmology
- Vol. 22 (1) , 1-8
Screening for retinopathy of prematurity in North China
Purpose: To analyze the incidence and severity of retinopathy of prematurity (ROP) in north China, and to evaluate the effectiveness of different ROP screening criteria. Patients and methods: The screening data of premature infants were collected from 2016 to 2021. The severity of ROP was graded according to the International Classification of Retinopathy of Prematurity (2005). And the treatment for ROP followed the Early Treatment for Retinopathy of Prematurity Cooperative Group. The effects of gestational age (GA) and birth weight (BW) on the incidence and severity of ROP were evaluated. The screening data were also analyzed using different ROP screening guidelines. Results: A total of 4069 infants underwent ROP screening, and 728 infants (17.9%) were diagnosed with ROP. Of those, 78 infants (1.9%) received treatments. Gestational age and BW showed significant differences between infants with and without ROP (29.1 ± 2.1w vs. 32.9 ± 2.6w, p < 0.001; 1362.7 ± 427.3 g vs. 1751.9 ± 509.4 g, p < 0.001; respectively). Fifty-six infants (7.69%), 188 infants (25.82%), and 104 infants (14.29%) in all infants with ROP would have been missed according to the China, USA, and UK screening guidelines respectively. If GA ≤ 33 weeks and/or BW ≤ 2100 g were considered as screening criteria, only one infant (0.14%) with critical systemic illness was missed diagnosed with severe ROP. Conclusion: Gestational age and BW are major risk factors for the incidence and severity of ROP. And the incidence and treatment rate of ROP in Tianjin is similar to that reported in the other regions of China. Modified ROP screening criteria were considered to be more effective in Tianjin.
- 6 June 2022
- Published by Springer Nature in BMC Ophthalmology
- Vol. 22 (1) , 1-8
Open AccessScreening for retinopathy of prematurity in North China
Purpose: To analyze the incidence and severity of retinopathy of prematurity (ROP) in north China, and to evaluate the effectiveness of different ROP screening criteria. Patients and methods: The screening data of premature infants were collected from 2016 to 2021. The severity of ROP was graded according to the International Classification of Retinopathy of Prematurity (2005). And the treatment for ROP followed the Early Treatment for Retinopathy of Prematurity Cooperative Group. The effects of gestational age (GA) and birth weight (BW) on the incidence and severity of ROP were evaluated. The screening data were also analyzed using different ROP screening guidelines. Results: A total of 4069 infants underwent ROP screening, and 728 infants (17.9%) were diagnosed with ROP. Of those, 78 infants (1.9%) received treatments. Gestational age and BW showed significant differences between infants with and without ROP (29.1 ± 2.1w vs. 32.9 ± 2.6w, p < 0.001; 1362.7 ± 427.3 g vs. 1751.9 ± 509.4 g, p < 0.001; respectively). Fifty-six infants (7.69%), 188 infants (25.82%), and 104 infants (14.29%) in all infants with ROP would have been missed according to the China, USA, and UK screening guidelines respectively. If GA ≤ 33 weeks and/or BW ≤ 2100 g were considered as screening criteria, only one infant (0.14%) with critical systemic illness was missed diagnosed with severe ROP. Conclusion: Gestational age and BW are major risk factors for the incidence and severity of ROP. And the incidence and treatment rate of ROP in Tianjin is similar to that reported in the other regions of China. Modified ROP screening criteria were considered to be more effective in Tianjin.
- Open Access
- 8 June 2018
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 18 (1) , 220
Macular choroidal thickness in highly myopic women during pregnancy and postpartum: a longitudinal study
High myopia, a cause of serious visual impairment, is a significant global public health concern. We investigate longitudinal changes in macular choroidal thickness (CT) during pregnancy and 6-months postpartum in women with high myopia (HM). A prospective longitudinal study was conducted in HM-pregnant women during the course of pregnancy (n = 42 eyes, 42 patients) and 6 months postpartum (n = 40 eyes, 40 patients, two cases lost).Macular CT was measured via enhanced-depth imaging (EDI)-optical coherence tomography (OCT) (EDI-OCT). Intraocular pressure (IOP), axial length (AL), refractive error, mean arterial pressure (MAP), mean ocular perfusion pressure (MOPP), and body mass index (BMI) were also measured. Macular CTs of HM pregnant women (214.3 ± 52.3 μm) had increased significantly during the third trimester of pregnancy compared with postpartum women (192.7 ± 51.9 μm, p = 0.014). No significant differences in AL, refractive error, or MAP were found between pregnant and postpartum groups (p > 0.05 for all parameters).During pregnancy, macular CT was negatively correlated with AL (first trimester: p = 0.010; second trimester: p = 0.013; and third trimester: p = 0.008) and positively correlated with refractive error (first trimester: p = 0.038; second trimester: p = 0.024; and third trimester: p = 0.010). No correlations between macular CT and age, IOP, MOPP, MAP, or BMI were found. Our study revealed the presence of a significantly thicker choroid during the third trimester of pregnancy compared with 6-mo postpartum in HM women. Macular CT positively correlated with refractive error and negatively correlated with AL during pregnancy, but did not correlate with gestational age, MOPP, IOP, MAP, or BMI.
- 8 June 2018
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 18 (1) , 220
Open AccessMacular choroidal thickness in highly myopic women during pregnancy and postpartum: a longitudinal study
High myopia, a cause of serious visual impairment, is a significant global public health concern. We investigate longitudinal changes in macular choroidal thickness (CT) during pregnancy and 6-months postpartum in women with high myopia (HM). A prospective longitudinal study was conducted in HM-pregnant women during the course of pregnancy (n = 42 eyes, 42 patients) and 6 months postpartum (n = 40 eyes, 40 patients, two cases lost).Macular CT was measured via enhanced-depth imaging (EDI)-optical coherence tomography (OCT) (EDI-OCT). Intraocular pressure (IOP), axial length (AL), refractive error, mean arterial pressure (MAP), mean ocular perfusion pressure (MOPP), and body mass index (BMI) were also measured. Macular CTs of HM pregnant women (214.3 ± 52.3 μm) had increased significantly during the third trimester of pregnancy compared with postpartum women (192.7 ± 51.9 μm, p = 0.014). No significant differences in AL, refractive error, or MAP were found between pregnant and postpartum groups (p > 0.05 for all parameters).During pregnancy, macular CT was negatively correlated with AL (first trimester: p = 0.010; second trimester: p = 0.013; and third trimester: p = 0.008) and positively correlated with refractive error (first trimester: p = 0.038; second trimester: p = 0.024; and third trimester: p = 0.010). No correlations between macular CT and age, IOP, MOPP, MAP, or BMI were found. Our study revealed the presence of a significantly thicker choroid during the third trimester of pregnancy compared with 6-mo postpartum in HM women. Macular CT positively correlated with refractive error and negatively correlated with AL during pregnancy, but did not correlate with gestational age, MOPP, IOP, MAP, or BMI.