OLOmri Lubovsky

Omri Lubovsky

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Omri Lubovsky has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Acetabular cup orientation and postoperative leg length discrepancy in patients undergoing elective total hip arthroplasty via a direct anterior and anterolateral approaches

    by Ronen Debi, Evyatar Slamowicz, Ornit Cohen, Avi Elbaz, Omri Lubovsky, Dror Lakstein, Zachary Tan, Ehud Atoun

    Total hip arthroplasty (THA) is considered a successful surgical procedure. It can be performed by several surgical approaches. Although the posterior and anterolateral approaches are the most common, there has been increased interest in the direct anterior approach. The goal of the present study is to compare postoperative leg length discrepancy and acetabular cup orientation among patients who underwent total hip arthroplasty through a direct anterior (DAA) and anterolateral (ALA) approaches. The study included 172 patients undergoing an elective THA by a single surgeon at our institution within the study period. Ninety-eight arthroplasties were performed through the ALA and 74 arthroplasties through the DAA. Preoperative planning was performed for all patients. Assessment of the two groups included the following postoperative parameters: abduction angle, cup anteversion angle and leg length discrepancy (LLD). Additional analysis was done to evaluate component positioning by comparing deviation from the Lewinnek zone of safety in both approaches. For the DAA the absolute LLD was 11 mm, ranging from -6 mm to 5 mm. For the ALA, the absolute LLD was 36 mm, ranging from -22 mm to 14 mm. None of the DAA patients had an absolute LLD greater than 6 mm. Comparatively, 7.4% of the ALA group exceeded 6 mm of LLD in addition to 2.1% with LLD greater than 10 mm. 15% of the ALA group resided out of the Lewinnek abduction zone compared to 3% of the DAA group (P = 0.016). 17% of the ALA group were out of the Lewinnek anteversion zone as opposed to 8% of the DAA group (P = 0.094). Our study demonstrates good component positioning outcomes and LLD values in patients following THA through the DAA compared to the ALA.


  • A novel self-care biomechanical treatment for obese patients with knee osteoarthritis

    by Omri Lubovsky, Amit Mor, Ganit Segal, Ehud Atoun, Ronen Debi, Yiftah Beer, Gabriel Agar, Doron Norman, Eli Peled, Avi Elbaz

    AimTo examine the effect of a novel biomechanical, home‐based, gait training device on gait patterns of obese individuals with knee OA.MethodsThis was a retrospective analysis of 105 (32 males, 73 females) obese (body mass index > 30 kg/m2) subjects with knee OA who completed a 12‐month program using a biomechanical gait training device and performing specified exercises. They underwent a computerized gait test to characterize spatiotemporal parameters, and completed the Western Ontario and McMaster Osteoarthritis Index (WOMAC) questionnaire and Short Form‐36 (SF‐36) Health Survey. They were then fitted with biomechanical gait training devices and began a home‐based exercise program. Gait patterns and clinical symptoms were assessed after 3 and 12 months of therapy.ResultsEach gait parameter improved significantly at 3 months and more so at 12 months (P = 0.03 overall). Gait velocity increased by 11.8% and by 16.1%, respectively. Single limb support of the more symptomatic knee increased by 2.5% and by 3.6%, respectively. There was a significant reduction in pain, stiffness and functional limitation at 3 months (P < 0.001 for each) that further improved at 12 months. Pain decreased by 34.7% and by 45.7%, respectively. Functional limitation decreased by 35.0% and by 44.7%, respectively. Both the Physical and Mental Scales of the SF‐36 increased significantly (P < 0.001) at 3 months and more so following 12 months.ConclusionsObese subjects with knee OA who complied with a home‐based exercise program using a biomechanical gait training device demonstrated a significant improvement in gait patterns and clinical symptoms after 3 months, followed by an additional improvement after 12 months.


  • Subchondral bone density distribution in the human femoral head

    by David A. Wright, Michael Meguid, Omri Lubovsky, Cari M. Whyne


  • Acetabular orientation: anatomical and functional measurement

    by Omri Lubovsky, David Wright, Michael Hardisty, Alex Kiss, Hans Kreder, Cari Whyne

    Acetabular orientation is important to consider in hip joint pathology and treatment. This study aims to describe the functional orientation of the acetabulum as a representative measure of force transmitted through the hip joint generated from bone density mapping and compare it to landmark-based anatomical orientation measures. CT scans of 38 non-pathologic individuals were analyzed. Functional orientation was computed as the density-weighted average of the acetabular surface normals based on surface density maps. Two anatomical measures were also used to describe the orientation of each acetabulum: the normal to the acetabular rim plane and the abduction angle based on AP pelvic “Radiographs” generated from the CT data. The average functional and anatomic abduction and anteversion angles ranged from 32°–58° and 22°–31°, respectively, with significant side-to-side correlation in individual patients for the majority of measures. Functional acetabular orientation was weakly correlated only with the rim plane measure. Native acetabular abduction in the 3D anatomic and functional methods was significantly shallower than the 2D “Radiographic” measure. The vector generated to describe functional acetabular orientation was found to be more vertically and posteriorly oriented than the anatomic measures. Functional acetabular orientation, reflecting the calculated directionality of the subchondral bone density, yields a more posterior and vertical measure of acetabular orientation as compared to the direction of load transmission suggested by the anatomic methods.


  • Importance of the dome and posterior wall as evidenced by bone density mapping in the acetabulum

    by Omri Lubovsky, David Wright, Michael Hardisty, Alex Kiss, Hans J. Kreder, Cari Whyne


  • Acetabular orientation variability and symmetry based on CT scans of adults

    by Omri Lubovsky, Eran Peleg, Leo Joskowicz, Meir Liebergall, Amal Khoury

    Understanding acetabular orientation is important in many orthopaedic procedures. Acetabular orientation, usually described by anteversion and abduction angles, has uncertain measurement variability in adult patients. The goals of this study are threefold: (1) to describe a new method for computing patient-specific abduction/anteversion angles from a single CT study based on the identification of anatomical landmarks and acetabular rim points; (2) to quantify the inaccuracies associated with landmark selection in computing the acetabular angles; and (3) to quantify the variability and symmetry of acetabular orientation. A total of 25 CT studies from adult patients scanned for non-orthopaedic indications were retrospectively reviewed. The patients were randomly selected from the hospital’s database. Inclusion criteria were adults 20–65 years of age. Acetabular landmark coordinates were identified by expert observers and tabulated in a spreadsheet. Two sets of calculations were done using the data: (1) computation of the abduction and anteversion for each patient, and (2) evaluation of the variability of measurements in the same individual by the same surgeon. The results were tabulated and summary statistics computed. This retrospective study showed that acetabular abduction and anteversion angles averaged 54° and 17°, respectively, in adults. A clinically significant intra-patient variability of >20° was found. We also found that the right and left side rim plane orientation were significantly correlated, but were not always symmetric. A new method of computing patient-specific abduction and anteversion angles from a CT study of the anterior pelvic plane and the left and right acetabular rim planes was reliable and accurate. We found that the acetabular rim plane can be reliably and accurately computed from identified points on the rim. The novelty of this work is that angular measurements are performed between planes on a 3-D model rather than lines on 2-D projections, as was done in the past.


  • A new external upper airway opening device combined with a cervical collar

    by Omri Lubovsky, Meir Liebergall, Charles Weissman, Meros Yuval