David Reens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Reens has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Colin D. Bruzewicz
7 shared publications- John Chiaverini
Massachusetts Institute of Technology, Cambridge, MA, USA
7 shared publications - Dave Kharas
MIT Lincoln Laboratory
5 shared publications - Hao Wu
Department of Physics and Astronomy, University of California, Los Angeles, Los Angeles, USA
5 shared publications - Robert McConnell
Lincoln Laboratory, Massachusetts Institute of Technology, Lexington, MA, USA
5 shared publications - Jeremy M. Sage
Lincoln Laboratory, Massachusetts Institute of Technology, Lexington, MA, USA
4 shared publications
Latest Publications
- 13 July 2026
- Published by Springer Nature in Nature Physics
- Vol. 22 (9) , 1446-1452
Error correction of a logical qubit encoded in a single atomic ion
- 13 July 2026
- Published by Springer Nature in Nature Physics
- Vol. 22 (9) , 1446-1452
Error correction of a logical qubit encoded in a single atomic ion
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (6)
Real-time magnetic field noise correction using trapped-ion monitor qubits
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review A
- Vol. 113 (6)
Real-time magnetic field noise correction using trapped-ion monitor qubits
- Open Access
- 17 February 2025
- Published by Springer Nature in Nature Photonics
- Vol. 19 (3) , 335
Publisher Correction: Optical atomic clock interrogation using an integrated spiral cavity laser
- 17 February 2025
- Published by Springer Nature in Nature Photonics
- Vol. 19 (3) , 335
Open AccessPublisher Correction: Optical atomic clock interrogation using an integrated spiral cavity laser
- 6 January 2025
- Published by Springer Nature in Nature Photonics
- Vol. 19 (3) , 277-283
Optical atomic clock interrogation using an integrated spiral cavity laser
- 6 January 2025
- Published by Springer Nature in Nature Photonics
- Vol. 19 (3) , 277-283
Optical atomic clock interrogation using an integrated spiral cavity laser
- Open Access
Optical Atomic Clock Interrogation Via an Integrated Spiral Cavity Laser
Optical atomic clocks have demonstrated revolutionary advances in precision timekeeping, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to clock portability stems from the many obstacles not only in miniaturizing the underlying components of the clock $-$ namely the ultrastable laser, the frequency comb, and the atomic reference itself $-$ but also in making the clock resilient to environmental fluctuations. Photonic integration offers one compelling solution to simultaneously address the problems of miniaturization and ruggedization, but brings with it a new set of challenges in recreating the functionality of an optical clock using chip-scale building blocks. The clock laser used for atom interrogation is one particular point of uncertainty, as the performance of the meticulously-engineered bulk-cavity stabilized lasers would be exceptionally difficult to transfer to chip. Here we demonstrate that a chip-integrated ultrahigh quality factor (Q) spiral cavity, when interfaced with a 1348 nm seed laser, reaches a fractional frequency instability of $7.5 \times 10^{-14}$, meeting the stability requirements for interrogating the narrow-linewidth transition of $^{88}$Sr$^+$ upon frequency doubling to 674 nm. In addition to achieving the record for laser stability on chip, we use this laser to showcase the operation of a Sr-ion clock with short-term instability averaging down as $3.9 \times 10^{-14} / \sqrtτ$, where $τ$ is the averaging time. Our demonstration of an optical atomic clock interrogated by an integrated spiral cavity laser opens the door for future advanced clock systems to be entirely constructed using lightweight, portable, and mass-manufacturable integrated optics and electronics.Open AccessOptical Atomic Clock Interrogation Via an Integrated Spiral Cavity Laser
Optical atomic clocks have demonstrated revolutionary advances in precision timekeeping, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to clock portability stems from the many obstacles not only in miniaturizing the underlying components of the clock $-$ namely the ultrastable laser, the frequency comb, and the atomic reference itself $-$ but also in making the clock resilient to environmental fluctuations. Photonic integration offers one compelling solution to simultaneously address the problems of miniaturization and ruggedization, but brings with it a new set of challenges in recreating the functionality of an optical clock using chip-scale building blocks. The clock laser used for atom interrogation is one particular point of uncertainty, as the performance of the meticulously-engineered bulk-cavity stabilized lasers would be exceptionally difficult to transfer to chip. Here we demonstrate that a chip-integrated ultrahigh quality factor (Q) spiral cavity, when interfaced with a 1348 nm seed laser, reaches a fractional frequency instability of $7.5 \times 10^{-14}$, meeting the stability requirements for interrogating the narrow-linewidth transition of $^{88}$Sr$^+$ upon frequency doubling to 674 nm. In addition to achieving the record for laser stability on chip, we use this laser to showcase the operation of a Sr-ion clock with short-term instability averaging down as $3.9 \times 10^{-14} / \sqrtτ$, where $τ$ is the averaging time. Our demonstration of an optical atomic clock interrogated by an integrated spiral cavity laser opens the door for future advanced clock systems to be entirely constructed using lightweight, portable, and mass-manufacturable integrated optics and electronics. - 2 September 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (10) , 100502
High-Fidelity Ion State Detection Using Trap-Integrated Avalanche Photodiodes
Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. We detect the state of a trapped ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in , opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.- 2 September 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (10) , 100502
High-Fidelity Ion State Detection Using Trap-Integrated Avalanche Photodiodes
Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. We detect the state of a trapped ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in , opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.- Open Access
- 1 October 2021
- Published by Elsevier in Measurement
- Vol. 183, 109888
Detection and manipulation of the transverse motion of neutral molecules in a Stark decelerator
- 1 October 2021
- Published by Elsevier in Measurement
- Vol. 183, 109888
Open AccessDetection and manipulation of the transverse motion of neutral molecules in a Stark decelerator
- Open Access
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11700, 117000K-16
A Brillouin laser optical atomic clock
Optical clocks have achieved accuracies better than 1 part in 1018 and are now some of the best measurement devices ever made, significantly surpassing previous-generation microwave clocks in terms of stability. A significant challenge is to transition optical clocks to field environments, which requires the ruggedization and miniaturization of the atomic reference and clock laser along with their supporting lasers and electronics. In this talk, I discuss the use of a stimulated-Brillouin-scattering (SBS) laser based on a compact fiber resonator to run an optical clock, demonstrating a potential portable replacement for the bulk-cavity-stabilized lasers typically used as the stable oscillator in these systems. We achieve a short-term stability of 3.9 x 10-14 in 1 s, outperforming the best microwave clocks. I also discuss our development of integrated photonics and detectors for chip-based ion traps as a pathway towards miniaturizing the clock’s atomic reference through elimination of free-space optics for light delivery and collection.
- 5 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11700, 117000K-16
Open AccessA Brillouin laser optical atomic clock
Optical clocks have achieved accuracies better than 1 part in 1018 and are now some of the best measurement devices ever made, significantly surpassing previous-generation microwave clocks in terms of stability. A significant challenge is to transition optical clocks to field environments, which requires the ruggedization and miniaturization of the atomic reference and clock laser along with their supporting lasers and electronics. In this talk, I discuss the use of a stimulated-Brillouin-scattering (SBS) laser based on a compact fiber resonator to run an optical clock, demonstrating a potential portable replacement for the bulk-cavity-stabilized lasers typically used as the stable oscillator in these systems. We achieve a short-term stability of 3.9 x 10-14 in 1 s, outperforming the best microwave clocks. I also discuss our development of integrated photonics and detectors for chip-based ion traps as a pathway towards miniaturizing the clock’s atomic reference through elimination of free-space optics for light delivery and collection.
- Open Access
- 19 January 2021
- Published by Springer Nature in Nature
- Vol. 590 (7844) , E19
Publisher Correction: Integrated multi-wavelength control of an ion qubit
- 19 January 2021
- Published by Springer Nature in Nature
- Vol. 590 (7844) , E19
Open AccessPublisher Correction: Integrated multi-wavelength control of an ion qubit
- 9 December 2020
- Published by Springer Nature in Nature
- Vol. 588 (7837) , 244-249
Operation of an optical atomic clock with a Brillouin laser subsystem
Microwave atomic clocks have traditionally served as the ‘gold standard’ for precision measurements of time and frequency. However, over the past decade, optical atomic clocks1,2,3,4,5,6 have surpassed the precision of their microwave counterparts by two orders of magnitude or more. Extant optical clocks occupy volumes of more than one cubic metre, and it is a substantial challenge to enable these clocks to operate in field environments, which requires the ruggedization and miniaturization of the atomic reference and clock laser along with their supporting lasers and electronics4,7,8,9. In terms of the clock laser, prior laboratory demonstrations of optical clocks have relied on the exceptional performance gained through stabilization using bulk cavities, which unfortunately necessitates the use of vacuum and also renders the laser susceptible to vibration-induced noise. Here, using a stimulated Brillouin scattering laser subsystem that has a reduced cavity volume and operates without vacuum, we demonstrate a promising component of a portable optical atomic clock architecture. We interrogate a 88Sr+ ion with our stimulated Brillouin scattering laser and achieve a clock exhibiting short-term stability of 3.9 × 10−14 over one second—an improvement of an order of magnitude over state-of-the-art microwave clocks. This performance increase within a potentially portable system presents a compelling avenue for substantially improving existing technology, such as the global positioning system, and also for enabling the exploration of topics such as geodetic measurements of the Earth, searches for dark matter and investigations into possible long-term variations of fundamental physics constants10,11,12.
- 9 December 2020
- Published by Springer Nature in Nature
- Vol. 588 (7837) , 244-249
Operation of an optical atomic clock with a Brillouin laser subsystem
Microwave atomic clocks have traditionally served as the ‘gold standard’ for precision measurements of time and frequency. However, over the past decade, optical atomic clocks1,2,3,4,5,6 have surpassed the precision of their microwave counterparts by two orders of magnitude or more. Extant optical clocks occupy volumes of more than one cubic metre, and it is a substantial challenge to enable these clocks to operate in field environments, which requires the ruggedization and miniaturization of the atomic reference and clock laser along with their supporting lasers and electronics4,7,8,9. In terms of the clock laser, prior laboratory demonstrations of optical clocks have relied on the exceptional performance gained through stabilization using bulk cavities, which unfortunately necessitates the use of vacuum and also renders the laser susceptible to vibration-induced noise. Here, using a stimulated Brillouin scattering laser subsystem that has a reduced cavity volume and operates without vacuum, we demonstrate a promising component of a portable optical atomic clock architecture. We interrogate a 88Sr+ ion with our stimulated Brillouin scattering laser and achieve a clock exhibiting short-term stability of 3.9 × 10−14 over one second—an improvement of an order of magnitude over state-of-the-art microwave clocks. This performance increase within a potentially portable system presents a compelling avenue for substantially improving existing technology, such as the global positioning system, and also for enabling the exploration of topics such as geodetic measurements of the Earth, searches for dark matter and investigations into possible long-term variations of fundamental physics constants10,11,12.