NANuri Arslan

Nuri Arslan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nuri Arslan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Synthesis and Ready to Use Kit Formulation of EDTMP for the Preparation of 177Lu-EDTMP as a Bone Palliation Radiopharmaceutical

    by Guldem Mercanoglu, Kani Zilbeyaz, Nuri Arslan

    Introduction: With its suitable nuclear decay characteristics and large-scale production feasibility with adequate specific activity, 177Lu is regarded as an excellent radionuclide for developing bone pain palliation agent. Ethylenediamine-tetramethylenephosphonic acid (EDTMP) is a preferred carrier molecule for radiolanthanides such as 177Lu. The present paper describes the synthesis of EDTMP and the development of a ready-to-use kit for the preparation of 177Lu-EDTMP and its quality control in accordance with the quality and safety criteria required for medicinal use. Material and Methods: EDTMP was synthesized by a modified Mannich-type reaction and the structure was characterized using NMR and IR spectroscopy. Optimization of radiolabeling conditions were carried out with two different salt forms of EDTMP. The labeling yield was checked by paper chromatography with radiation detection. Kit was developed as a lyophilized mixture of EDTMP and sodium bicarbonate in a maximum volume of 5 mL. Labeling efficiency, radionuclidic purity, radiochemical purity, sterility, and pyrogenity analysis were performed as the quality control of the labeled kit. Results: The analytical data for the structure determination and purity of the synthesized ligand were in agreement with commercial authentic samples used in radiopharmacy.177Lu-EDTMP complex was prepared using synthesized EDTMP ligand under optimized labeling conditions with high labelling yield (>99%). The radiolabeling yields of the EDTMP kit at room temperature after 30 min and 48 hours were 99.46% and 99.00%. Conclusion: The developed EDTMP kit enables an instant one-step preparation of the radiopharmaceutical of high radiochemical purity (>99%) and has a sufficiently long shelf life. This enables the routine production of the 177Lu-EDTMP in nuclear medicine clinics without requiring experienced staff.


  • Open Access

    Correlation of Morphological and Functional Cardiac Images: Fusion of Myocardial Perfusion SPECT and CT Angiography

    by Hüseyin Şan, Alper Özgür Karaçalıoğlu, Uğur Bozlar, Semra İnce, Engin Alagöz, Mustafa Özdeş Emer, Mustafa Taşar, Nuri Arslan

    Objectives: The current study evaluates the value of cardiac hybrid imaging (CHI), performed by the fusion of functional and anatomic cardiac images, in the detection of hemodynamically significant coronary stenosis in cases with multiple coronary stenosis. Methods: A total of 36 patients (10 female, 26 male) in whom ischemia or infarction was detected on gated myocardial perfusion single photon emission computed tomography (gMPS) and multiple coronary stenosis were concomitantly detected on coronary computed tomography angiography (CCTA) and undergone invasive coronary angiography (ICA) was included in this study. Statistical analyses were performed using SPSS 22 Windows software. McNemar test was applied to show concordance between coronary CT angiography, ICA and CHI in the detection of anatomically or hemodynamically significant stenosis in three major coronary arteries. Comparison results of coronary arteries responsible for perfusion defects on CHI and gMPS are presented as percentages (%). Results: There was total accordance between coronary arteries leading to perfusion defects detected by gMPS and CHI in 50% of patients. It was observed a partial accordance in 36.1% of the patients. Additionally, it was also detected perfusion defects originated from side branches in 25% of the patients. Between results of CCTA and ICA, no statistically significant difference was noted in the detection of anatomically significant stenoses in the left main coronary artery, left anterior descending artery (LAD), left circumflex artery (LCx) and right coronary artery (RCA) (p=1.000, 0.070, 0.549, and 1.000, respectively). In addition, no statistically significant difference was found in the detection of anatomically and hemodynamically significant stenoses in LAD, LCx and RCA by CCTA and CHI (p=0.344, 0.629, and 0.219, respectively). No statistically significant difference was observed in the detection of anatomically and hemodynamically significant stenoses in LAD, LCx and RCA by ICA and CHI (p=0.804, 1.000, and 0.344, respectively). Conclusion: It is possible to detect hemodynamically significant coronary stenosis directly by CHI modality in patients with multiple coronary stenosis, wide perfusion defects.

  • Open Access

    Utility of FDG PET/CT in the Management of Primary Testicular Lymphoma

    by Kürşat Okuyucu, Semra İnce, Engin Alagöz, Erman Ataş, Nuri Arslan

    Objective: Primary testicular lymphoma (PTL) is a form of extra-nodal lymphoma originating from the testicles. Currently, positron emission tomography (PET) with glucose analogue 18F-fluorodeoxyglucose (18F-FDG) is the most popular and widely used modality for evaluating tumor metabolism, and PTL usually displays increased 18F-FDG uptake. Despite the rapid increase in clinical applications of FDG PET/computed tomography (CT), its role in PTL has neither been clearly defined nor reviewed systematically. This study reviews the usefulness and limitation of FDG PET/CT in the diagnosis and treatment of PTL. Methods: This study included 12 patients with PTL between 2004 and 2015. We retrospectively examined PET/CT results along with patient outcome. The maximum standardized uptake value (SUVmax) was calculated. Results: The mean overall survival (OS) and disease-free survival (DFS) was 44.5 months and 35.5 months, respectively. The mean SUVmax was identified as 18.5 in recurrent/metastatic group. The 1-year and 3-year OS was 94% and 69%, while the 1-year and 2-year DFS was 93.5% and 56%, respectively. Conclusion: FDG PET/CT is very helpful in both staging and evaluating treatment response. Although it is not a perfect tool in the initial diagnosis, it might aid in the differential diagnosis of challenging testicular tumors. Pre-treatment and post-treatment FDG uptake values may also have a prognostic value in patients with PTL.


  • Unusual patterns of I-131 contamination

    by Mehmet Ozguven, Seyfettin Ilgan, Nuri Arslan, A. Ozgur Karacalioglu, Dogangun Yuksel, Sabri Dundar

    Whole body imaging with radioiodine can detect functioning metastases, which can often be effectively treated with appropriate amounts of radioiodine. Non-physiologic I-131 uptake detected on images is usually interpreted as suggesting functioning thyroid metastases. However, extra-thyroidal I-131 accumulation does not always imply thyroid cancer metastases and has been reported on many occasions, including various non-thyroidal neoplasms, and contamination by body secretions. In order to avoid unnecessary therapeutic interventions it is extremely important to properly distinguish false-positive sites of I-131 localization. Three patients with unusual radioiodine contamination patterns, either presented for the first time or rarely presented in the existing literature, were reported. Reported cases consist of contamination in hair (due to styling hair with sputum), contamination in neck (due to drooling during sleep) and, contaminated chewing gum. False positive contamination sources were clarified by careful examination of patients and further images when necessary.