TBThomas Büttner

Thomas Büttner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Thomas Büttner has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Pilot Study of AI-Assisted ANA Immunofluorescence Reading—Comparison with Classical Visual Interpretation

    by Sarah Mayr, Margit Dollinger, Boris Ehrenstein, Florian Günther, Olga Krammer, Antonia Schuster, Thomas Büttner, Rico Hiemann, Peter Schierack, Dirk Roggenbuck, et al.

    Background: Antinuclear antibodies (ANAs) play a crucial role in diagnosing systemic autoimmune rheumatic diseases, particularly systemic lupus erythematosus. The recommended standard for ANA detection is indirect immunofluorescence testing (IIFT) using human epithelial (HEp-2) cells. Since visual interpretation (VI) of IIFT images is time-consuming and labor-intensive, research is focusing on automated interpretation systems that use artificial intelligence (AI). Methods: Consecutive serum samples (number of sera = 143) from routine clinical care were collected from patients visiting our tertiary rheumatology center. ANA were detected by IIFT with visual interpretation and compared with IIFT using the AI-based interpretation system akiron® NEO (Medipan, 15827 Blankenfelde-Mahlow, Germany). ANA titer levels and patterns were analyzed according to the Competent Level of the International Consensus on ANA Pattern classification. Results: Agreement of positive/negative ANA discrimination between AI-aided and VI-IIFT at the recommended cut-off of 80 was good (Cohen’s kappa [κ] 0.69) but significantly different (McNemar test, p < 0.0001). At a cut-off of ≥1/80, the agreement was improved (κ 0.76) and the difference between both methods was non-significant (p = 1.0000). The ANA pattern recognition agreement between both approaches was moderate (κ = 0.54). The direct comparison using only the akiron® NEO HEp-2 cell ANA assay revealed a good agreement (0.67), which improved to very good (κ = 0.80) when differences between ANA patterns anti-cell (AC)4/5 and AC2 were neglected. Notably, titer levels in the automated evaluations were frequently assessed at higher values than in the gold standard interpretation. Conclusions: Our study demonstrates a good agreement for positive/negative ANA discrimination. ANA pattern recognition by AI-aided interpretation showed moderate to very good agreement with VI. Further research and algorithm refinement (e.g., improved pattern recognition and titer calibration) are necessary to support its future implementation as a reliable screening method.


  • Open Access

    Anti-phospholipid IgG antibodies detected by line immunoassay differentiate patients with anti-phospholipid syndrome and other autoimmune diseases

    by Cecilia Nalli, Valentina Somma, Laura Andreoli, Thomas Büttner, Peter Schierack, Michael Mahler, Dirk Roggenbuck, Angela Tincani

    Anti-phospholipid antibodies (aPL) analyzed by line immunoassay (LIA) can recognize beta2-glycoprotein I (β2GPI) domain 1 (D1) epitopes depending on β2GPI binding to distinct phospholipids. The aPL LIA was compared with consensus ELISA to investigate whether both techniques can discriminate anti-phospholipid syndrome (APS) patients from aPL-positive, systemic autoimmune rheumatic diseases (SARD) patients without clinical symptoms of APS and controls. Thirty-four APS patients (14 arterial/venous thrombosis, 16 pregnancy morbidity, and 4 both), 41 patients with SARD lacking clinical APS criteria but demonstrating positivity for anti-β2GPI (aβ2GPI) IgG, and 20 healthy subjects (HS) were tested for aPL to cardiolipin (aCL), phosphatidic acid, phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol (aPG), phosphatidylinositol, phosphatidylserine, β2GPI, prothrombin, and annexin V by LIA. Samples were also tested for aCL, aβ2GPI, aβ2GPI-domain 1 (aD1), and aβ2GPI-domains 4–5 (aD4–5) by ELISA and for lupus anti-coagulant. Comparison of LIA with ELISA revealed a good agreement for the consensus criteria aPL aβ2GPI and aCL IgG (kappa = 0.69, 0.68, respectively) and a moderate agreement for IgM (kappa = 0.52, 0.49, respectively). Regarding ELISA, aD1/aD4–5 demonstrated the best performance of differentiating APS from asymptomatic SARD [area under the curve (AUC): 0.76]. aPG IgG had the best performance by LIA (AUC: 0.72) not significantly different from aD1/aD4–5. There was a good agreement for aPG IgG with aD1/aD4–5 (kappa = 0.71). aD1/aD4–5 (ELISA) and aPG IgG (LIA) differentiate APS from SARD patients. PG appears to interact with β2GPI of APS patients and exposes D1 thereof for disease-specific aPL binding in LIA.


  • Open Access

    Automated interpretation of ANCA patterns - a new approach in the serology of ANCA-associated vasculitis

    by Ilka Knütter, Rico Hiemann, Therese Brumma, Thomas Büttner, Kai Großmann, Marco Cusini, Francesca Pregnolato, Maria Orietta Borghi, Ursula Anderer, Karsten Conrad, et al.

    Introduction: Indirect immunofluorescence (IIF) employing ethanol-fixed neutrophils (ethN) is still the method of choice for assessing antineutrophil cytoplasmic antibodies (ANCA) in ANCA-associated vasculitides (AAV). However, conventional fluorescence microscopy is subjective and prone to high variability. The objective of this study was to evaluate novel pattern recognition algorithms for the standardized automated interpretation of ANCA patterns. Methods: Seventy ANCA-positive samples (20 antimyeloperoxidase ANCA, 50 antiproteinase3 ANCA) and 100 controls from healthy individuals analyzed on ethN and formalin-fixed neutrophils (formN) by IIF were used as a 'training set' for the development of pattern recognition algorithms. Sera from 342 patients ('test set') with AAV and other systemic rheumatic and infectious diseases were tested for ANCA patterns using the novel pattern recognition algorithms and conventional fluorescence microscopy. Results: Interpretation software employing pattern recognition algorithms was developed enabling positive/negative discrimination and classification of cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA). Comparison of visual reading of the 'test set' samples with automated interpretation revealed Cohen's kappa (κ) values of 0.955 on ethN and 0.929 on formN for positive/negative discrimination. Analysis of the 'test set' with regard to the discrimination between C-ANCA and P-ANCA patterns showed a high agreement for ethN (κ = 0.746) and formN (κ = 0.847). There was no significant difference between visual and automated interpretation regarding positive/negative discrimination on ethN and formN, as well as ANCA pattern recognition (P > 0.05, respectively). Conclusions: Pattern recognition algorithms can assist in the automated interpretation of ANCA IIF. Automated reading of ethN and formN IIF patterns demonstrated high consistency with visual ANCA assessment.


  • Open Access

    Single-step autoantibody profiling in antiphospholipid syndrome using a multi-line dot assay

    by Karl Egerer, Dirk Roggenbuck, Thomas Büttner, Barbara Lehmann, Annushka Kohn, Philipp von Landenberg, Rico Hiemann, Eugen Feist, Gerd-Rüdiger Burmester, Thomas Dörner

    Introduction: Diagnosis of antiphospholipid syndrome (APS) still remains a laboratory challenge due to the great diversity of antiphospholipid antibodies (aPL) and their significance regarding APS-diagnostic criteria. Methods: A multi-line dot assay (MLDA) employing phosphatidylserine (PS), phosphatidylinositol (PI), cardiolipin (CL), and beta2-glycoprotein I (β2 GPI) was used to detect aPL, immunoglobulin G (IgG) and immunoglobulin M (IgM) in 85 APS patients, 65 disease controls, and 79 blood donors. For comparison, anti-CL and anti-β2 GPI IgG and IgM were detected by enzyme-linked immunosorbent assay (ELISA). Results: The level of agreement of both methods was good for anti-CL IgG, moderate for anti-CL IgM, very good for anti-β2 GPI IgG, and moderate for anti-β2 GPI IgM (kappa = 0.641, 0.507, 0.803 and 0.506, respectively). The frequency of observed discrepancies for anti-CL IgG (1.75%), anti-CL IgM (3.93%), anti-β2 GPI IgG (1.75%), and anti-β2 GPI IgM (0.87%) was low (McNemar test, P < 0.05, not-significant, respectively). Sensitivity, specificity, positive (+LR) and negative (-LR) likelihood ratios for at least one positive aPL antibody assessed by ELISA were 58.8%, 95.8%, 14.1, and 0.4, respectively, and for at least three positive aPl IgM and/or one positive aPL IgG by MLDA were 67.1%, 96.5%, 19.3, and 0.3, respectively. The frequency of IgM to PI, PS and CL, and combination of three or more aPL IgM detected by MLDA was significantly higher in APS patients with cerebral transient ischemia (P < 0.05, respectively). Conclusions: The novel MLDA is a readily available, single-step, sensitive diagnostic tool for the multiplex detection of aPL antibodies in APS and a potential alternative for single aPL antibody testing by ELISA.


  • Open Access

    Automated evaluation of autoantibodies on human epithelial-2 cells as an approach to standardize cell-based immunofluorescence tests

    by Karl Egerer, Dirk Roggenbuck, Rico Hiemann, Max-Georg Weyer, Thomas Büttner, Boris Radau, Rosemarie Krause, Barbara Lehmann, Eugen Feist, Gerd-Rüdiger Burmester

    Introduction: Analysis of autoantibodies (AAB) by indirect immunofluorescence (IIF) is a basic tool for the serological diagnosis of systemic rheumatic disorders. Automation of autoantibody IIF reading including pattern recognition may improve intra- and inter-laboratory variability and meet the demand for cost-effective assessment of large numbers of samples. Comparing automated and visual interpretation, the usefulness for routine laboratory diagnostics was investigated. Methods: Autoantibody detection by IIF on human epithelial-2 (HEp-2) cells was conducted in a total of 1222 consecutive sera of patients with suspected systemic rheumatic diseases from a university routine laboratory (n = 924) and a private referral laboratory (n = 298). IIF results from routine diagnostics were compared with a novel automated interpretation system. Results: Both diagnostic procedures showed a very good agreement in detecting AAB (kappa = 0.828) and differentiating respective immunofluorescence patterns. Only 98 (8.0%) of 1222 sera demonstrated discrepant results in the differentiation of positive from negative samples. The contingency coefficients of chi-square statistics were 0.646 for the university laboratory cohort with an agreement of 93.0% and 0.695 for the private laboratory cohort with an agreement of 90.6%, P < 0.0001, respectively. Comparing immunofluorescence patterns, 111 (15.3%) sera yielded differing results. Conclusions: Automated assessment of AAB by IIF on HEp-2 cells using an automated interpretation system is a reliable and robust method for positive/negative differentiation. Employing novel mathematical algorithms, automated interpretation provides reproducible detection of specific immunofluorescence patterns on HEp-2 cells. Automated interpretation can reduce drawbacks of IIF for AAB detection in routine diagnostics providing more reliable data for clinicians.