Young Ju Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Young Ju Lee has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Gi-Ja Lee
Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, Republic of Korea
5 shared publications - Jae Hyung Kim
Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, Korea
2 shared publications - Yong-Jin Ahn
Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, Korea
2 shared publications - Young-Gyu Eun
Department of Biomedical Science and Technology, Graduate School, Kyung Hee University, Seoul, Republic of Korea
2 shared publications - Byung-Ki Ahn
Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, Korea
1 shared publication - Doyeon Lee
Department of Medical Engineering, Graduate School, Kyung Hee University, Seoul 130-701, Korea
1 shared publication
Latest Publications
- Open Access
Simple and Sensitive Detection of Bacterial Hydrogen Sulfide Production Using a Paper-Based Colorimetric Assay
Hydrogen sulfide (H2S) is known to participate in bacteria-induced inflammatory response in periodontal diseases. Therefore, it is necessary to quantify H2S produced by oral bacteria for diagnosis and treatment of oral diseases including halitosis and periodontal disease. In this study, we introduce a paper-based colorimetric assay for detecting bacterial H2S utilizing silver/Nafion/polyvinylpyrrolidone membrane and a 96-well microplate. This H2S-sensing paper showed a good sensitivity (8.27 blue channel intensity/μM H2S, R2 = 0.9996), which was higher than that of lead acetate paper (6.05 blue channel intensity/μM H2S, R2 = 0.9959). We analyzed the difference in H2S concentration released from four kinds of oral bacteria (Eikenella corrodens, Streptococcus sobrinus, Streptococcus mutans, and Lactobacillus casei). Finally, the H2S level in Eikenella corrodens while varying the concentration of cysteine and treatment time was quantified. This paper-based colorimetric assay can be utilized as a simple and effective tool for in vitro screening of H2S-producing ability of many bacteria as well as salivary H2S analysis.
Open AccessSimple and Sensitive Detection of Bacterial Hydrogen Sulfide Production Using a Paper-Based Colorimetric Assay
Hydrogen sulfide (H2S) is known to participate in bacteria-induced inflammatory response in periodontal diseases. Therefore, it is necessary to quantify H2S produced by oral bacteria for diagnosis and treatment of oral diseases including halitosis and periodontal disease. In this study, we introduce a paper-based colorimetric assay for detecting bacterial H2S utilizing silver/Nafion/polyvinylpyrrolidone membrane and a 96-well microplate. This H2S-sensing paper showed a good sensitivity (8.27 blue channel intensity/μM H2S, R2 = 0.9996), which was higher than that of lead acetate paper (6.05 blue channel intensity/μM H2S, R2 = 0.9959). We analyzed the difference in H2S concentration released from four kinds of oral bacteria (Eikenella corrodens, Streptococcus sobrinus, Streptococcus mutans, and Lactobacillus casei). Finally, the H2S level in Eikenella corrodens while varying the concentration of cysteine and treatment time was quantified. This paper-based colorimetric assay can be utilized as a simple and effective tool for in vitro screening of H2S-producing ability of many bacteria as well as salivary H2S analysis.
- Open Access
- 10 January 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (1) , 27
In Situ Detection of Hydrogen Sulfide in 3D-Cultured, Live Prostate Cancer Cells Using a Paper-Integrated Analytical Device
In this study, a paper-integrated analytical device that combined a paper-based colorimetric assay with a paper-based cell culture platform was developed for the in situ detection of hydrogen sulfide (H2S) in three-dimensional (3D)-cultured, live prostate cancer cells. Two kinds of paper substrates were fabricated using a simple wax-printing methodology to form the cell culture and detection zones, respectively. LNCaP cells were seeded directly on the paper substrate and grown in the paper-integrated analytical device. The cell viability and H2S production of LNCaP cells were assessed using a simple water-soluble tetrazolium salt colorimetric assay and H2S-sensing paper, respectively. The H2S-sensing paper showed good sensitivity (sensitivity: 6.12 blue channel intensity/μM H2S, R2 = 0.994) and a limit of quantification of 1.08 μM. As a result, we successfully measured changes in endogenous H2S production in 3D-cultured, live LNCaP cells within the paper-integrated analytical device while varying the duration of incubation and substrate concentration (L-cysteine). This paper-integrated analytical device can provide a simple and effective method to investigate H2S signaling pathways and drug screening in a 3D culture model.
- 10 January 2022
- Published by MDPI AG in Chemosensors
- Vol. 10 (1) , 27
Open AccessIn Situ Detection of Hydrogen Sulfide in 3D-Cultured, Live Prostate Cancer Cells Using a Paper-Integrated Analytical Device
In this study, a paper-integrated analytical device that combined a paper-based colorimetric assay with a paper-based cell culture platform was developed for the in situ detection of hydrogen sulfide (H2S) in three-dimensional (3D)-cultured, live prostate cancer cells. Two kinds of paper substrates were fabricated using a simple wax-printing methodology to form the cell culture and detection zones, respectively. LNCaP cells were seeded directly on the paper substrate and grown in the paper-integrated analytical device. The cell viability and H2S production of LNCaP cells were assessed using a simple water-soluble tetrazolium salt colorimetric assay and H2S-sensing paper, respectively. The H2S-sensing paper showed good sensitivity (sensitivity: 6.12 blue channel intensity/μM H2S, R2 = 0.994) and a limit of quantification of 1.08 μM. As a result, we successfully measured changes in endogenous H2S production in 3D-cultured, live LNCaP cells within the paper-integrated analytical device while varying the duration of incubation and substrate concentration (L-cysteine). This paper-integrated analytical device can provide a simple and effective method to investigate H2S signaling pathways and drug screening in a 3D culture model.
- Open Access
- 4 August 2020
- Published by MDPI AG in Chemosensors
- Vol. 8 (3) , 63
Electrochemical Detection of H2O2 Released from Prostate Cancer Cells Using Pt Nanoparticle-Decorated rGO–CNT Nanocomposite-Modified Screen-Printed Carbon Electrodes
In this study, we fabricated platinum nanoparticles (PtNP)-decorated, porous reduced graphene oxide (rGO)–carbon nanotube (CNT) nanocomposites on a PtNP-deposited screen-printed carbon electrode (PtNP/rGO–CNT/PtNP/SPCE) for detection of hydrogen peroxide (H2O2), which is released from prostate cancer cells LNCaP. The PtNP/rGO–CNT/PtNP/SPCE was fabricated by a simple electrochemical deposition and co-reduction method. In addition, the amperometric response of the PtNP/rGO–CNT/PtNP/SPCE electrode was evaluated through consecutive additions of H2O2 at an applied potential of 0.2 V (vs. Ag pseudo-reference electrode). As a result, the prepared PtNP/rGO–CNT/PtNP/SPCE showed good electrocatalytic activity toward H2O2 compared to bare SPCE, rGO–CNT/SPCE, PtNP/SPCE, and rGO–CNT/PtNP/SPCE. In addition, the PtNP/rGO–CNT/PtNP/SPCE electrode exhibited a sensitivity of 206 μA mM−1·cm−2 to H2O2 in a linear range of 25 to 1000 μM (R2 = 0.99). Moreover, the PtNP/rGO–CNT/PtNP/SPCE electrode was less sensitive to common interfering substances, such as ascorbic acid, uric acid, and glucose than H2O2. Finally, real-time monitoring of H2O2 released from LNCaP cells was successfully performed by this electrode. Therefore, we expect that the PtNP/rGO–CNT/PtNP/SPCE can be utilized as a promising electrochemical sensor for practical nonenzymatic detection of H2O2 in live cells or clinical analysis.
- 4 August 2020
- Published by MDPI AG in Chemosensors
- Vol. 8 (3) , 63
Open AccessElectrochemical Detection of H2O2 Released from Prostate Cancer Cells Using Pt Nanoparticle-Decorated rGO–CNT Nanocomposite-Modified Screen-Printed Carbon Electrodes
In this study, we fabricated platinum nanoparticles (PtNP)-decorated, porous reduced graphene oxide (rGO)–carbon nanotube (CNT) nanocomposites on a PtNP-deposited screen-printed carbon electrode (PtNP/rGO–CNT/PtNP/SPCE) for detection of hydrogen peroxide (H2O2), which is released from prostate cancer cells LNCaP. The PtNP/rGO–CNT/PtNP/SPCE was fabricated by a simple electrochemical deposition and co-reduction method. In addition, the amperometric response of the PtNP/rGO–CNT/PtNP/SPCE electrode was evaluated through consecutive additions of H2O2 at an applied potential of 0.2 V (vs. Ag pseudo-reference electrode). As a result, the prepared PtNP/rGO–CNT/PtNP/SPCE showed good electrocatalytic activity toward H2O2 compared to bare SPCE, rGO–CNT/SPCE, PtNP/SPCE, and rGO–CNT/PtNP/SPCE. In addition, the PtNP/rGO–CNT/PtNP/SPCE electrode exhibited a sensitivity of 206 μA mM−1·cm−2 to H2O2 in a linear range of 25 to 1000 μM (R2 = 0.99). Moreover, the PtNP/rGO–CNT/PtNP/SPCE electrode was less sensitive to common interfering substances, such as ascorbic acid, uric acid, and glucose than H2O2. Finally, real-time monitoring of H2O2 released from LNCaP cells was successfully performed by this electrode. Therefore, we expect that the PtNP/rGO–CNT/PtNP/SPCE can be utilized as a promising electrochemical sensor for practical nonenzymatic detection of H2O2 in live cells or clinical analysis.
- Open Access
Optimization of Saliva Collection and Immunochromatographic Detection of Salivary Pepsin for Point-of-Care Testing of Laryngopharyngeal Reflux
Salivary pepsin is a promising marker for the non-invasive diagnosis of laryngopharyngeal reflux (LPR). For reliable results regarding pepsin in saliva, it is critical to standardize the collection, storage, and pre-processing methods. In this study, we optimized the saliva collection protocols, including storage conditions, i.e., solution, temperature, and time, and the pre-processing filter for pepsin. Moreover, we prepared a simple immunochromatographic strip for the rapid detection of pepsin and evaluated its sensing performance. As a result, we selected a polypropylene (PP) filter as the pre-processing filter for salivary pepsin in low resource settings, such as those where point of care testing (POCT) is conducted. This filter showed a similar efficiency to the centrifuge (standard method). Finally, we detected the pepsin using gold nanoparticles conjugated with monoclonal pepsin antibody. Under optimized conditions, the lower limit of detection for pepsin test strips was determined as 0.01 μg/mL. Furthermore, we successfully detected the salivary pepsin in real saliva samples of LPR patients, which were pre-processed by the PP filter. Therefore, we expect that our saliva collection protocol and pepsin immunochromatographic strip can be utilized as useful tools for a non-invasive diagnosis/screening of LPR in POCT.
Open AccessOptimization of Saliva Collection and Immunochromatographic Detection of Salivary Pepsin for Point-of-Care Testing of Laryngopharyngeal Reflux
Salivary pepsin is a promising marker for the non-invasive diagnosis of laryngopharyngeal reflux (LPR). For reliable results regarding pepsin in saliva, it is critical to standardize the collection, storage, and pre-processing methods. In this study, we optimized the saliva collection protocols, including storage conditions, i.e., solution, temperature, and time, and the pre-processing filter for pepsin. Moreover, we prepared a simple immunochromatographic strip for the rapid detection of pepsin and evaluated its sensing performance. As a result, we selected a polypropylene (PP) filter as the pre-processing filter for salivary pepsin in low resource settings, such as those where point of care testing (POCT) is conducted. This filter showed a similar efficiency to the centrifuge (standard method). Finally, we detected the pepsin using gold nanoparticles conjugated with monoclonal pepsin antibody. Under optimized conditions, the lower limit of detection for pepsin test strips was determined as 0.01 μg/mL. Furthermore, we successfully detected the salivary pepsin in real saliva samples of LPR patients, which were pre-processed by the PP filter. Therefore, we expect that our saliva collection protocol and pepsin immunochromatographic strip can be utilized as useful tools for a non-invasive diagnosis/screening of LPR in POCT.
- Open Access
Label-Free Detection of Salivary Pepsin Using Gold Nanoparticle/Polypyrrole Nanocoral Modified Screen-Printed Electrode
Detection of salivary pepsin has been given attention as a new diagnostic tool for laryngopharyngeal reflux (LPR) disease, because saliva collection is non-invasive and relatively comfortable. In this study, we prepared polypyrrole nanocorals (PPNCs) on a screen-printed carbon electrode (SPCE) by a soft template synthesis method, using β-naphthalenesulfonic acid (NSA) (for short, PPNCs/SPCE). Gold nanoparticles (GNPs) were then decorated on PPNCs/SPCE by electrodeposition (for short, GNP/PPNCs/SPCE). To construct the immunosensor, pepsin antibody was immobilized on GNP/PPNCs/SPCE. Next, citric acid was applied to prevent non-specific binding and change the electrode surface charge before pepsin incubation. Electrochemical stepwise characterization was performed using cyclic voltammetry, and immunosensor response toward different pepsin concentrations was measured by differential pulsed voltammetry. As a result, our electrochemical immunosensor showed a sensitive detection performance toward pepsin with a linear range from 6.25 to 100 ng/mL and high specificity toward pepsin, as well as a low limit of detection of 2.2 ng/mL. Finally, we quantified the pepsin levels in saliva samples of LPR patients (n = 2), showing that the results were concordant with those of a conventional ELISA method. Therefore, we expect that this electrochemical immunosensor could be helpful for preliminarily diagnosing LPR through the detection of pepsin in saliva.
Open AccessLabel-Free Detection of Salivary Pepsin Using Gold Nanoparticle/Polypyrrole Nanocoral Modified Screen-Printed Electrode
Detection of salivary pepsin has been given attention as a new diagnostic tool for laryngopharyngeal reflux (LPR) disease, because saliva collection is non-invasive and relatively comfortable. In this study, we prepared polypyrrole nanocorals (PPNCs) on a screen-printed carbon electrode (SPCE) by a soft template synthesis method, using β-naphthalenesulfonic acid (NSA) (for short, PPNCs/SPCE). Gold nanoparticles (GNPs) were then decorated on PPNCs/SPCE by electrodeposition (for short, GNP/PPNCs/SPCE). To construct the immunosensor, pepsin antibody was immobilized on GNP/PPNCs/SPCE. Next, citric acid was applied to prevent non-specific binding and change the electrode surface charge before pepsin incubation. Electrochemical stepwise characterization was performed using cyclic voltammetry, and immunosensor response toward different pepsin concentrations was measured by differential pulsed voltammetry. As a result, our electrochemical immunosensor showed a sensitive detection performance toward pepsin with a linear range from 6.25 to 100 ng/mL and high specificity toward pepsin, as well as a low limit of detection of 2.2 ng/mL. Finally, we quantified the pepsin levels in saliva samples of LPR patients (n = 2), showing that the results were concordant with those of a conventional ELISA method. Therefore, we expect that this electrochemical immunosensor could be helpful for preliminarily diagnosing LPR through the detection of pepsin in saliva.