Shijun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shijun Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Feng Hua Li
Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Jing Du
Department of Ultrasound, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication - Ruhui Tian
Department of Andrology, Centre for Men’s Health, Department of ART, Urologic Medical Centre, Key Laboratory of Reproductive Medicine, Institute of Urology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
1 shared publication - Shaowei Xie
Department of Ultrasound, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200127, China
1 shared publication - Zheng Li
Department of Andrology, Center for Men's Health, Urologic Medical Center, Shanghai General Hospital, Shanghai Jiao Tong University, Shanghai 200080, China
1 shared publication
Latest Publications
- Open Access
- 23 May 2018
- Published by Springer Nature in BMC Urology
- Vol. 18 (1) , 48
Assessment of the use of contrast enhanced ultrasound in guiding microdissection testicular sperm extraction in nonobstructive azoospermia
The aim of this study is to assess the value of contrast-enhanced ultrasound (CEUS) as a new non-invasive approach to locate the testicular area in which spermatogenesis is most likely to be found in non-obstructive azoospermic testes and to evaluate the accuracy of CEUS as a predictor of successful sperm retrieval. CEUS was performed in 120 nonobstructive azoospermia (NOA) patients. Microdissection testicular sperm extraction (M-TESE) was performed on the best and poorest perfusion areas selected by CEUS and on conventional areas. In the 187 testicles that underwent M-TESE, the sperm retrieval rates (SRRs) in the best perfusion area and poorest perfusion area over the maximal longitudinal section and conventional area were 63.1, 34.7 and 47.1%. According to receiver operating characteristic (ROC) analysis, the arrival times (AT) ≤27 s, time-to-peak intensity (TTP) ≤45 s, and peak intensity (PI) ≥11 dB were the best predictors of positive sperm retrieval. The location of the best perfusion area was able to guide M-TESE to improve the success rates. Testicle CEUS is suggested to be performed in all patients with NOA. If AT≤27 s, TTP ≤ 45 s or PI≥11 dB are found in the best perfusion area, M-TESE is strongly recommended.
- 23 May 2018
- Published by Springer Nature in BMC Urology
- Vol. 18 (1) , 48
Open AccessAssessment of the use of contrast enhanced ultrasound in guiding microdissection testicular sperm extraction in nonobstructive azoospermia
The aim of this study is to assess the value of contrast-enhanced ultrasound (CEUS) as a new non-invasive approach to locate the testicular area in which spermatogenesis is most likely to be found in non-obstructive azoospermic testes and to evaluate the accuracy of CEUS as a predictor of successful sperm retrieval. CEUS was performed in 120 nonobstructive azoospermia (NOA) patients. Microdissection testicular sperm extraction (M-TESE) was performed on the best and poorest perfusion areas selected by CEUS and on conventional areas. In the 187 testicles that underwent M-TESE, the sperm retrieval rates (SRRs) in the best perfusion area and poorest perfusion area over the maximal longitudinal section and conventional area were 63.1, 34.7 and 47.1%. According to receiver operating characteristic (ROC) analysis, the arrival times (AT) ≤27 s, time-to-peak intensity (TTP) ≤45 s, and peak intensity (PI) ≥11 dB were the best predictors of positive sperm retrieval. The location of the best perfusion area was able to guide M-TESE to improve the success rates. Testicle CEUS is suggested to be performed in all patients with NOA. If AT≤27 s, TTP ≤ 45 s or PI≥11 dB are found in the best perfusion area, M-TESE is strongly recommended.