VGVadim Gliner

Vadim Gliner

*This is an algorithmically generated author record based on publicly available information.

Vadim Gliner has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessment of the impact of non-architectural changes in the predictive model on the quality of ECG classification

    by Vladislav Valerievich Ananev, Sergej Nikolaevich Skorik, Vsevolod Vladislavovich Shaklein, Aram Arutyunovich Avetisyan, Yurij Emilevich Teregulov, Denis Yuryevich Turdakov, Vadim Gliner, Assaf Schuster, Evgeny Andreevich Karpulevich

    Запись и расшифровка электрокардиограммы в 12 отведениях является наиболее распространенной процедурой для определения сердечных заболеваний. В последнее время предлагаются различные методы машинного обучения для автоматической постановки диагноза по электрокардиограмме. Их задача – предоставить второе мнение для врача и помочь обнаружить патологию на ранней стадии. В статье рассматриваются методы улучшения качества автоматического определения патологий по ЭКГ: добавление метаданных пациента, уменьшение шума электрокардиограммы и самоадаптивное обучение. Также представлены результаты экспериментального исследования влияние различных ЭКГ отведений, значимости длины электрокардиограммы и объема обучающей выборки на результаты работы алгоритмов. Проведенные эксперименты показывают релевантность описываемых подходов, а также предлагают оптимальную оценку параметров входных данных.


  • Open Access

    Novel Method to Efficiently Create an mHealth App: Implementation of a Real-Time Electrocardiogram R Peak Detector

    by Vadim Gliner, Joachim Behar, Yael Yaniv

    Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.


  • Open Access

    Novel Method to Efficiently Create an mHealth App: Implementation of a Real-Time Electrocardiogram R Peak Detector (Preprint)

    by Vadim Gliner, Joachim Behar, Yael Yaniv

    Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: In parallel to the introduction of mobile communication devices with high computational power and internet connectivity, high-quality and low-cost health sensors have also become available. However, although the technology does exist, no clinical mobile system has been developed to monitor the R peaks from electrocardiogram recordings in real time with low false positive and low false negative detection. Implementation of a robust electrocardiogram R peak detector for various arrhythmogenic events has been hampered by the lack of an efficient design that will conserve battery power without reducing algorithm complexity or ease of implementation. Objective: Our goals in this paper are (1) to evaluate the suitability of the MATLAB Mobile platform for mHealth apps and whether it can run on any phone system, and (2) to embed in the MATLAB Mobile platform a real-time electrocardiogram R peak detector with low false positive and low false negative detection in the presence of the most frequent arrhythmia, atrial fibrillation. Methods: We implemented an innovative R peak detection algorithm that deals with motion artifacts, electrical drift, breathing oscillations, electrical spikes, and environmental noise by low-pass filtering. It also fixes the signal polarity and deals with premature beats by heuristic filtering. The algorithm was trained on the annotated non–atrial fibrillation MIT-BIH Arrhythmia Database and tested on the atrial fibrillation MIT-BIH Arrhythmia Database. Finally, the algorithm was implemented on mobile phones connected to a mobile electrocardiogram device using the MATLAB Mobile platform. Results: Our algorithm precisely detected the R peaks with a sensitivity of 99.7% and positive prediction of 99.4%. These results are superior to some state-of-the-art algorithms. The algorithm performs similarly on atrial fibrillation and non–atrial fibrillation patient data. Using MATLAB Mobile, we ran our algorithm in less than an hour on both the iOS and Android system. Our app can accurately analyze 1 minute of real-time electrocardiogram signals in less than 1 second on a mobile phone. Conclusions: Accurate real-time identification of heart rate on a beat-to-beat basis in the presence of noise and atrial fibrillation events using a mobile phone is feasible.