ZZZhiwei Zhang

Zhiwei Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhiwei Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Xiao Li

    Department of Radiology, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China

    2 shared publications
  • Fajin Lv

    Department of Radiology The First Affiliated Hospital of Chongqing Medical University Chongqing China

    1 shared publication
  • Fajin Lv

    Department of Radiology, The First Affiliated Hospital of Chongqing Medical University

    1 shared publication
  • Ge Zhang

    Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China

    1 shared publication
  • Haitang Qiu

    Department of Psychiatry, the First Affiliated Hospital of Chongqing Medical University, Chongqing, China

    1 shared publication
  • Huan Tan

    Department of Radiology, The First Affiliated Hospital of Chongqing Medical University

    1 shared publication

Latest Publications

  • Open Access

    Radiation and Contrast Medium Dosage Optimization of Coronary CT Angiography While Combining Personalized Patient Protocol Technology and Automated Tube Voltage Selection Technology

    by Jingkun Sun, Yang Zhou, Ge Zhang, Lijun Zhang, Xinnan Shen, Zhiwei Zhang

    Objective: This study aims to investigate whether combining automated tube voltage selection (ATVS) with P3T for contrast injection in coronary computed tomography angiography (CCTA) allows for patient-tailored scanning protocols. Specifically, we assessed whether this combination maintains equivalent image quality and adequate diagnostic image quality. Methods: This retrospective study included 378 patients who underwent CCTA using ATVS and P3T technologies. We divided the patients into three groups based on the scanning tube voltage: 70-, 80-, and 90-kV groups. Furthermore, each group was divided into sequence and spiral scanning subgroups based on the acquisition method. The CM injection volume and rate, volume CT dose index (CTDIvol), and dose–length product (DLP) were recorded. The CT value of the enhanced coronary artery, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated by artery segment. Image quality was evaluated using a four-point grading scale in a double-blind manner. Results: The SNR did not differ among the groups in any segments (p > 0.05). And the subjective image quality showed only minor differences among the groups. The body weight, which determines ATVS and P3T protocol algorithm, is positively correlated with the automatic tube voltage, CM injection volume, and effective radiation dose. Furthermore, when using the same tube voltage under the combined ATVS and P3T protocols, sequence scanning yielded a lower radiation dose than spiral scanning (p < 0.05). Conclusions: CCTA combining ATVS and P3T technology enables individualized scanning protocols while maintaining adequate diagnostic image quality.

  • Open Access

    Resting-state functional magnetic resonance imaging-based identification of altered brain the fractional amplitude of low frequency fluctuation in adolescent major depressive disorder patients undergoing electroconvulsive therapy

    by Xing-Yu Wang, Huan Tan, Xiao Li, Lin-Qi Dai, Zhi-Wei Zhang, Fa-Jin Lv, Ren-Qiang Yu

    Purpose: While electroconvulsive therapy (ECT) has been repeatedly been shown to effectively and efficiently treat the major depressive disorder (MDD), the mechanistic basis for such therapeutic efficacy remains to be firmly established. As such, further research exploring the ECT-based treatment of MDD in an adolescent population is warranted.Methods: This study included 30 treatment-naïve first-episode MDD patients and 30 healthy control (HC) individuals (aged 12–17 years). All participants were scanned using rs-fMRI, and the 30 MDD patients were scanned again after 2 weeks of the ECT treatment period. Intrinsic local activity in each voxel was assessed based on the fractional amplitude of low frequency fluctuation (fALFF) parameter, with all fALFF analyses being completed using the REST application. Correlations between ECT-related changes in fALFF and clinical parameters were additionally examined.Results: Relative to HCs, MDD patients exhibited increased fALFF values in the right inferior frontal gyrus (ORBinf), inferior occipital gyrus (IOG), and the left middle frontal gyrus (MFG) at baseline. Following ECT, these patients exhibited significant increases in fALFF values in the right medial superior frontal gyrus (SFGmed), dorsolateral superior frontal gyrus (SFGdor), anterior cingulate, and paracingulate gyrus (ACG), median cingulate and paracingulate gyrus (DCG), and left MFG. MDD patient HAMD scores were negatively correlated with fALFF values when analyzing pre-ECT vs. post-HCT ΔHAMD and fALFF values in the right SFGmed, SFGdor, and the left MFG.Conclusion: These data suggest that ECT induced altered fALFF in some regions of the brain, suggesting that these alterations may serve as a neurobiological indicator of ECT effectiveness in MDD adolescents.


  • Open Access

    The ultrafast, high‐pitch turbo FLASH mode of third‐generation dual‐source CT: Effect of different pitch and corresponding SFOV on image quality in a phantom study

    by Yang Zhou, Lei Hu, Silin Du, Rui Jin, Wangjia Li, Fajin Lv, Zhiwei Zhang

    Purpose: To investigate the effect of different pitches and corresponding scan fields of view (SFOVs) on the image quality in the ultrafast, high‐pitch turbo FLASH mode of the third‐generation dual‐source CT using an anthropomorphic phantom.Methods: The phantom was scanned using the ultrafast, high‐pitch turbo FLASH protocols of the third‐generation dual‐source CT with the different pitches and corresponding SFOVs (pitches: 1.55 to 3.2 with increments of 0.1, SFOVs: 50 cm to 35.4 cm). The objective parameters such as the CT number, image noises, signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and artifacts index (AI), and image features from the head, chest, and abdomen were compared between the CT images with a pitch of 1.55 and SFOV of Ø 50 cm and a pitch of 3.2 and SFOV of Ø 35.4 cm. Then, the 18 series of CT images of the head, chest, and abdomen were evaluated by three radiologists independently.Results: The differences in the CT numbers were not statically significant between the CT images with a pitch of 1.55 and SFOV of Ø 50 cm and a pitch of 3.2 and SFOV of Ø 35.4 cm from most body parts and potential combinations (p > 0.05), Most of the image noises and the AI from the images with the pitch of 1.55 were significantly lower than those with the pitch of 3.2 (p < 0.05), and the SNR and CNR from the images with the pitch of 1.55 were higher than those with the pitch of 3.2. There were significant differences in the first‐order features and texture features of the head (59.3%, 28.3%), chest (66%, 35.7%), and abdomen (71.6%, 64.7%) (p < 0.05). The subjective image quality was excellent when the pitch was less than 2.0 and gradually decreased with the increasing pitch. In addition, the image quality decreased significantly when the pitch was higher than 3.0 (all k≥0.69), especially in the head and chest.Conclusions: In the ultrafast, high‐pitch turbo FLASH mode of the third‐generation DSCT, increasing the pitch and lowering the corresponding SFOV will change the image features and cause more artifacts degrading the image quality. Specific to the clinical needs, decreasing the pitch not only can expand the SFOV but also can improve the image quality.


  • Open Access

    The Impact of Whole Brain Global Functional Connectivity Density Following MECT in Major Depression: A Follow-Up Study

    by Xiao Li, Huaqing Meng, Yixiao Fu, Lian Du, Haitang Qiu, Tian Qiu, Qibin Chen, Zhiwei Zhang, Qinghua Luo

    To explore the alteration of global functional connectivity density (gFCD) in depressive patients after modified electroconvulsive therapy (MECT) and analyze the relationship between gFCD and clinical outcome. Thirty-seven subjects were evaluated based on the diagnostic criteria of the International Classification of Diseases-10 (ICD-10), consisting of a depressive group (24 patients after follow-ups) and a healthy control group with 13 normal individuals. All participants received Hamilton Depression Scale (HAMD) scores and resting-state functional magnetic resonance imaging scans. The gFCD significantly increased in the posterior-middle insula, the supra-marginal gyrus and the dorsal medial prefrontal cortex (dmPFC) before MECT treatment compared to healthy controlled patients. The gFCD statistically expanded in the perigenual anterior cingulate cortex (pgACC), the orbitofrontal cortex bilaterally and the left-supra-marginal gyrus after MECT, and it decreased notably in the posterior insula. The gFCD in the pgACC and the right orbital frontal cortex of depressive group before MECT showed a positive correlation with HAMD scores with treatment. Conforming to the impact of gFCD in depressive patients after MECT, the aforementioned brain region may become an indicator of MECT effect.