AWAlexander Wong

Alexander Wong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander Wong has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MPCaD: a multi-scale radiomics-driven framework for automated prostate cancer localization and detection

    by Farzad Khalvati, Junjie Zhang, Audrey G. Chung, Mohammad Javad Shafiee, Alexander Wong, Masoom A. Haider

    Quantitative radiomic features provide a plethora of minable data extracted from multi-parametric magnetic resonance imaging (MP-MRI) which can be used for accurate detection and localization of prostate cancer. While most cancer detection algorithms utilize either voxel-based or region-based feature models, the complexity of prostate tumour phenotype in MP-MRI requires a more sophisticated framework to better leverage available data and exploit a priori knowledge in the field. In this paper, we present MPCaD, a novel Multi-scale radiomics-driven framework for Prostate Cancer Detection and localization which leverages radiomic feature models at different scales as well as incorporates a priori knowledge of the field. Tumour candidate localization is first performed using a statistical texture distinctiveness strategy that leverages a voxel-resolution feature model to localize tumour candidate regions. Tumour region classification via a region-resolution feature model is then performed to identify tumour regions. Both voxel-resolution and region-resolution feature models are built upon and extracted from six different MP-MRI modalities. Finally, a conditional random field framework that is driven by voxel-resolution relative ADC features is used to further refine the localization of the tumour regions in the peripheral zone to improve the accuracy of the results. The proposed framework is evaluated using clinical prostate MP-MRI data from 30 patients, and results demonstrate that the proposed framework exhibits enhanced separability of cancerous and healthy tissue, as well as outperforms individual quantitative radiomics models for prostate cancer detection. Quantitative radiomic features extracted from MP-MRI of prostate can be utilized to detect and localize prostate cancer.


  • Open Access

    Monte Carlo-based noise compensation in coil intensity corrected endorectal MRI

    by Dorothy Lui, Amen Modhafar, Masoom A. Haider, Alexander Wong

    Prostate cancer is one of the most common forms of cancer found in males making early diagnosis important. Magnetic resonance imaging (MRI) has been useful in visualizing and localizing tumor candidates and with the use of endorectal coils (ERC), the signal-to-noise ratio (SNR) can be improved. The coils introduce intensity inhomogeneities and the surface coil intensity correction built into MRI scanners is used to reduce these inhomogeneities. However, the correction typically performed at the MRI scanner level leads to noise amplification and noise level variations. In this study, we introduce a new Monte Carlo-based noise compensation approach for coil intensity corrected endorectal MRI which allows for effective noise compensation and preservation of details within the prostate. The approach accounts for the ERC SNR profile via a spatially-adaptive noise model for correcting non-stationary noise variations. Such a method is useful particularly for improving the image quality of coil intensity corrected endorectal MRI data performed at the MRI scanner level and when the original raw data is not available. SNR and contrast-to-noise ratio (CNR) analysis in patient experiments demonstrate an average improvement of 11.7 and 11.2 dB respectively over uncorrected endorectal MRI, and provides strong performance when compared to existing approaches. Experimental results using both phantom and patient data showed that ACER provided strong performance in terms of SNR, CNR, edge preservation, subjective scoring when compared to a number of existing approaches. A new noise compensation method was developed for the purpose of improving the quality of coil intensity corrected endorectal MRI data performed at the MRI scanner level. We illustrate that promising noise compensation performance can be achieved for the proposed approach, which is particularly important for processing coil intensity corrected endorectal MRI data performed at the MRI scanner level and when the original raw data is not available.


  • Open Access

    A Deep-Structured Fully Connected Random Field Model for Structured Inference

    by Alexander Wong, Mohammad Javad Shafiee, Parthipan Siva, Xiao Yu Wang

    There has been significant interest in the use of fully connected graphical models and deep-structured graphical models for the purpose of structured inference. However, fully connected and deep-structured graphical models have been largely explored independently, leaving the unification of these two concepts ripe for exploration. A fundamental challenge with unifying these two types of models is in dealing with computational complexity. In this paper, we investigate the feasibility of unifying fully connected and deep-structured models in a computationally tractable manner for the purpose of structured inference. To accomplish this, we introduce a deep-structured fully connected random field (DFRF) model that integrates a series of intermediate sparse autoencoding layers placed between state layers to significantly reduce the computational complexity. The problem of image segmentation was used to illustrate the feasibility of using the DFRF for structured inference in a computationally tractable manner. Results in this paper show that it is feasible to unify fully connected and deep-structured models in a computationally tractable manner for solving structured inference problems such as image segmentation.


  • Open Access

    Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements

    by Alexander Wong, Chenyi Liu, Xiao Yu Wang, Paul Fieguth, Hongxia Bie

    Positron emission tomography scanners collect measurements of a patient’s in vivo radiotracer distribution. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule, and the tomograms must be reconstructed from projections. The reconstruction of tomograms from the acquired PET data is an inverse problem that requires regularization. The use of tightly packed discrete detector rings, although improves signal-to-noise ratio, are often associated with high costs of positron emission tomography systems. Thus a sparse reconstruction, which would be capable of overcoming the noise effect while allowing for a reduced number of detectors, would have a great deal to offer. In this study, we introduce and investigate the potential of a homotopic non-local regularization reconstruction framework for effectively reconstructing positron emission tomograms from such sparse measurements. Results obtained using the proposed approach are compared with traditional filtered back-projection as well as expectation maximization reconstruction with total variation regularization. A new reconstruction method was developed for the purpose of improving the quality of positron emission tomography reconstruction from sparse measurements. We illustrate that promising reconstruction performance can be achieved for the proposed approach even at low sampling fractions, which allows for the use of significantly fewer detectors and have the potential to reduce scanner costs.


  • Computerised system for measurement of muscle thickness based on ultrasonography

    by Alexander Wong, Kaitlin M. Gallagher, Jack P. Callaghan

    In this paper, a computerised system for measuring muscle thicknesses of the transverse abdominus (TrA), internal oblique and external oblique muscles based on ultrasonography is presented. The system is designed to allow for quantitative analysis of changes in muscle recruitment and activity, which facilitates the study of such changes and its relationship with low back pain. The abdominal muscle area was localised and imaged under different standing conditions using B-mode ultrasonography. To account for issues such as misalignments due to probe and subject motion as well as speckle noise inherent to ultrasonography, automatic ensemble registration is performed on the acquired images using a sequential quadratic programming approach based on a novel log-Rayleigh likelihood function. Regions of interest are then automatically identified based on the medial border of the TrA for the purpose of quantitative muscle thickness measurements. Experimental results show that the proposed system achieves registration errors of under 0.4 mm when compared with ground-truth measurements, as well as allow for the measurement of muscle thickness changes in the millimetre range. The proposed system is currently in operational use as an analysis tool for studying the relationship between abdominal muscle thickness changes and postural changes.