FWFumihiko Watanabe

Fumihiko Watanabe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fumihiko Watanabe has a total of 42 co-authors. Here are the top co-authors by number of shared publications:

  • Yoshiaki Hata

    Department of Crown and Bridge Prosthodontics, The Nippon Dental University School of Life Dentistry at Niigata, Hamaura-chou 1-8, Chuuou-ku, Niigata, 951-8580, Japan

    3 shared publications
  • Kazuhiko Ueda

    Department of Crown and Bridge Prosthodontics, School of Life Dentistry at Niigata, The Nippon Dental University

    2 shared publications
  • Shigeki Komatsu

    Department of Crown and Bridge Prosthodontics, School of Life Dentistry at Niigata, The Nippon Dental University, Niigata, Japan

    2 shared publications
  • Yasuyuki Tawada

    Department of Crown and Bridge Prosthodontics, School of Life Dentistry at Niigata, The Nippon Dental University, Niigata, Japan

    2 shared publications
  • Yuji Sato

    Department of Geriatric Dentistry, School of Dentistry, Showa University, 2-1-1 Kitasenzoku, Ohta-ku, Tokyo 145-8515, Japan

    2 shared publications
  • Akio Isobe

    Department of Geriatric Dentistry, Showa University School of Dentistry, 2-1-1, Kitasenzoku, Ohta-ku, Tokyo, 145-8515, Japan

    1 shared publication

Latest Publications

  • Open Access

    Maintenance issues of elderly patients requiring nursing care with implant treatments in dental visiting: position paper

    by Chikahiro Ohkubo, Noriharu Ikumi, Yuji Sato, Mai Shirai, Kazuhiro Umehara, Isao Ohashi, Hirokazu Shibagaki, Yoshimine Niki, Chihiro Masaki, Itaru Mikami, et al.

    Japan, with an increasing number of elderly people needing long-term care in a super-aged society, urgent needs to develop the clinical guidelines on implant maintenance for elderly people with declining independence. The purpose is to categorize the troubles encountered in the care of patients with dental implants and to indicate actual practices and points of note. From the members of the Japanese Society of Oral Implantology, 12 expert panelists who were experienced with many problems of implant maintenance during dental visits and were familiar with their solutions were selected. Through repeated discussions in the many panel meetings, the problems of implant maintenance during dental visits were distilled. During a dental visit, the oral cavity, general conditions, and background of elderly patients who cannot orally care for themselves must be grasped, and medical staff, care managers, and patients should understand the changes in these factors as time goes by. The solutions and responses that can be made differ greatly depending on the medical care facilities, the environment, differences in the experience of medical staff, and the patient’s background. Thus, it is necessary to select safe treatments appropriate to each situation. This paper features many opinions based on clinical experiences. However, clinical guidelines on implant management during dental visits should be formulated in the future based on the accumulation of evidence through the implementation of clinical research.


  • Effect of impression holding time and tray removal speed on the dimensional accuracy of impressions for artificial abutment tooth inclined

    by Yoshiaki Hirota, Yasuyuki Tawada, Shigeki Komatsu, Fumihiko Watanabe

    Oral scanners allow dental impressions to be taken in a short time without the use of an impression material. However, it has been noted that high impression accuracy cannot be obtained in cases where the abutment is inclined or in cases where the span is long. Consequently, in daily clinical practice, impressions are often created using silicone impression material. When taking an impression using silicone impression material, the curing time or the removal time of the impression material are often based on the intuition of the dental staff. This study investigated the effects of impression holding time and impression tray removal speed on the dimensional accuracy of impressions. A specimen with an abutment inclined 30° to the removal direction of an impression was prepared. Four types of silicone rubber impression materials were used. Impressions were taken with two levels of holding time and two levels of removal speed using an autograph. The diameter of stone models was measured at 3, 6, and 9 mm from the baseline of each. The height of the inclined and opposite sides was also measured. Two-way analysis of variance was used to analyze data regarding the assessment of the effects of holding time and tray removal speed. The reproducibility of the impressions was affected by the volume of undercut caused by the inclined abutment. For a large undercut, longer holding times and faster tray removal speeds are recommended to reduce the deformation of silicone rubber impressions.


  • Fracture force for veneered materials on restorations measured by torsion testing

    by Fumihiko Watanabe, Munetsugu Seto, Kazuhiko Ueda, Makoto Ozawa

    The torsional fracture strength at the interface between a base plate and veneering material was evaluated for three kinds of veneered restoration: porcelain fused to zirconia (PFZ), porcelain fused to metal (PFM), and composite resin veneered metal (CRVM). The metal and zirconia base plate (30×4×0.4 mm) were prepared and these plates were veneered as test specimens using each material to a total thickness of 1.2 mm. Torsional force was applied to each specimen using a rotational speed of 1.0 deg/min until the veneering material underwent fracture or exfoliation. The torsional fracture values were measured and the data were statistically analyzed using one-way ANOVA. The torsional fracture strength for PFZ, PFM, and CRVM was 3.0, 3.1, and 11.1 N•cm, respectively.


  • Open Access

    A preliminary report on dental implant condition among dependent elderly based on the survey among Japanese dental practitioners

    by Yuji Sato, Shigeto Koyama, Chikahiro Ohkubo, Shin Ogura, Ryutaro Kamijo, Soh Sato, Jun Aida, Yuichi Izumi, Mihoko Atsumi, Akio Isobe, et al.

    The objective of this study was to ascertain the situation relevant to implants, the status of oral self-care, the status of aftercare provided by the dentist who placed the implant, and the usage status of the implant card, in homebound or institutionalized older adults who are receiving home-visit dental care due to the inability to visit a dental clinic on their own. A survey questionnaire was sent by post mail to 2339 people who are representative members or dental specialists belonging to any of the following three academic societies: Japanese Society of Oral Implantology, Japanese Society of Gerodontology, and Japan Prosthodontic Society. The survey questions asked were about provision/no provision of implant treatment, provision/no provision of home-visit dental care, the situation of patients after implant treatment, the situation of implants in the context of home-visit dental care, and the usage status and recognition of the implant card. No less than 30% of the dentists had patients who were admitted to the hospital or became homebound after receiving implant treatment at their clinic. Twenty-two percent of the dentists had been consulted about the implants. Dentists who continued to provide post-operative implant care through home-visit dental care accounted for approximately 80%. On the other hand, however, 40% of the dentists did not know the post-implantation status of their implant patients. Of the patients receiving home-visit dental care, approximately 3% had implants (identified mainly by visual inspection). It was found that more than 50% of the dentists offering implant treatment did not use the implant card, and even in cases where it was used, most of the cards were not in the standardized format. Within the limitation of low response rate to the questionnaire in this preliminary study, we concluded that many of practitioners including specialists indicated the need of universal record of implant for dependent elderly cares.


  • Open Access

    The fracture strength by a torsion test at the implant-abutment interface

    by Fumihiko Watanabe, Kazuhiko Hiroyasu, Kazuhiko Ueda

    Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey’s test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p < 0.01). Concerning mean torsional yield strength, significant differences were found between 3.3, 3.8, and 4.3 mm-diameter and 5.0 and 6.0 mm-diameter implants (p < 0.01). Observations under the SEM showed that all the projections of the abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.


  • Comparison of diameters at the cementoenamel junction between South Asians and Japanese

    by Hirohisa Nose, Yasuyuki Tawada, Fumihiko Watanabe, Ikuo Kageyama

    Previously, sex differences among the various tooth types in Japanese skulls were examined to facilitate choosing an implant diameter similar to the cervical diameter of each tooth, and it was found that mesiodistal diameters at the cementoenamel junction were narrower in women than in men. Also interesting and relevant to the selection of implant diameter is the possible existence of racial differences in diameters at the cementoenamel junction. The purpose of this research was to test the hypothesis that the diameter at the cementoenamel junction of the tooth differs in humans of different races. We compared 106 skulls of unknown sex collected from South Asia with the skulls of Japanese women. Our conclusions are as follows: (1) Except for the lower canine, no significant racial differences were found in the labiolingual diameter of any teeth. (2) Except for the upper canine, upper central incisor, lower second premolar, and lower first premolar, a significant racial difference was found in the mesiodistal diameter. In all teeth in which this value differed, the mesiodistal diameters of South Asians were narrower than those of Japanese women, except for the lower canine. (3) The labiolingual and mesiodistal diameters of the lower canine were significantly larger in South Asians than in Japanese women. (4) Among South Asians, no significant left/right differences were found in the diameter at the cementoenamel junction of any tooth.


  • Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution

    by Fumihiko Watanabe, Yoshiaki Hata, Shigeki Komatsu, Tristan C. Ramos, Hiroshi Fukuda

    The selection of the appropriate alignment of an implant and the position of implantation are vital for its longterm success. Excessive load is generated around inclined implants, causing microcracks in the bone, which result in implant loosening and eventual failure. This study was designed to analyze the stress distribution caused by varying the degree of inclination of an implant body and varying the loading position and direction, using the finite-element method of stress analysis. Buccal and lingual two-dimensional simulation models of a cylinder implant, embedded in the first molar edentulous cross-section of the mandible, were prepared, and the stress distribution and maximum principal stresses were recorded. Regardless of the point and direction of loading, compressive stresses were relatively greater when the implant was inclined. This tendency became more pronounced when a 45° loading direction and eccentric loading were tested. For the inclined model, with a 45° loading direction, the compressive stress was observed on the cortical bone adjacent to the direction of inclination, while tensile stress was observed on the opposite side.


  • Retrieval and replacement of a malpositioned dental implant: A clinical report

    by Fumihiko Watanabe, Yoshiaki Hata, Izumi Mataga, Sumio Yoshie