SAShyam S. Adhikari

Shyam S. Adhikari

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shyam S. Adhikari has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Inductively coupled magic angle spinning microresonators benchmarked for high-resolution single embryo metabolomic profiling

    by Shyam S. Adhikari, Li Zhao, Thomas Dickmeis, Jan G. Korvink, Vlad Badilita

    The magic angle coil spinning (MACS) technique has been introduced as a very promising extension for solid state NMR detection, demonstrating sensitivity enhancements by a factor of 14 from the very first time it has been reported. The main beneficiary of this technique is the scientific community dealing with mass- and volume-limited, rare, or expensive samples. However, more than a decade after the first report on MACS, there is a very limited number of groups who have continued to develop the technique, let alone it being widely adopted by practitioners. This might be due to several drawbacks associated with the MACS technology until now, including spectral linewidth, heating due to eddy currents, and imprecise manufacturing. Here, we report a device overcoming all these remaining issues, therefore achieving: (1) spectral resolution of approx 0.01 ppm and normalized limit of detection of approx. 13 nmol s0.5 calculated using the anomeric proton of sucrose at 3 kHz MAS frequency; (2) limited temperature increase inside the MACS insert of only 5 °C at 5 kHz MAS frequency in an 11.74 T magnetic field, rendering MACS suitable to study live biological samples. The wafer-scale fabrication process yields MACS inserts with reproducible properties, readily available to be used on a large scale in bio-chemistry labs. To illustrate the potential of these devices for metabolomic studies, we further report on: (3) ultra-fine 1H–1H and 13C–13C J-couplings resolved within 10 min for a 340 mM uniformly 13C-labeled glucose sample; and (4) single zebrafish embryo measurements through 1H–1H COSY within 4.5 h, opening the gate for the single embryo NMR studies.


  • Open Access

    A Non-Resonant Kinetic Energy Harvester for Bioimplantable Applications

    by Mustafa İ. Beyaz, Hacene C. Baelhadj, Sahar Habibiabad, Shyam S. Adhikari, Hossein Davoodi, Vlad Badilita

    A linear non-resonant kinetic energy harvester for implantable devices is presented. The design contains a metal platform with permanent magnets, two stators with three-dimensional helical coils for increased power generation, ball bearings, and a polydimethylsiloxane (PDMS) package for biocompatibility. Mechanical excitation of this device within the body due to daily activities leads to a relative motion between the platform and stators, resulting in electromagnetic induction. Initial prototypes without packaging have been fabricated and characterized on a linear shaker. Dynamic tests showed that the friction force acting on the platform is on the order of 0.6 mN. The resistance and the inductance of the coils were measured to be 2.2 Ω and 0.4 µH, respectively. A peak open circuit voltage of 1.05 mV was generated per stator at a platform speed of 5.8 cm/s. Further development of this device offers potential for recharging the batteries of implantable biomedical devices within the body.


  • Capacitor re‐design overcomes the rotation rate limit ofMACSresonators

    by Shyam S. Adhikari, Ulrike Wallrabe, Vlad Badilita, Jan G. Korvink

    The magic angle coil spinning (MACS) technique has provided a breakthrough in enhancing sensitivity in magic angle spinning (MAS)NMR. However, efforts in improving theMACSdetector for higher spinning speeds have been lacking. One publishedMACSconstruction technique is to solder a handwound solenoidal coil to a commercial non‐magnetic capacitor and subsequently centering the detector inside theMASrotor. An alternative method to realize these detectors is by usingMEMSfabrication at the wafer scale, potentially capable of achieving reproducibleMACSdetectors. However, it is also important that the performance of the sensors does not deteriorate as a result of microfabrication constraints. The footprint of the detectors is a limiting factor in achieving higher spinning speeds. One of the key elements of a micro‐resonator is its tuning capacitor, whose geometry has a significant influence on its electrical and mechanical performance. The quality factor of the capacitor, along with the induced eddy currents, are the key performance parameters considered. The article addresses these concerns by presenting a study of microfabricated on‐chip capacitors for magic angle coil spinning (MACS) detectors. The capacitors are juxtaposed with commercially available capacitors and the most suitable fit to be integrated with a micro‐coil is established.