Hubert Latappy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hubert Latappy has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Allan Lopes
Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France
1 shared publication - Essyllt Louarn
Universite Claude Bernard Lyon 1, CNRS, IRCELYON, UMR 5256
1 shared publication - Hélène Mestdagh
Laboratoire de Chimie Physique, UMR 8000, CNRS et Université Paris Sud, 91405 Orsay, France
1 shared publication - Joël Lemaire
Centre National de la Recherche Scientifique
1 shared publication - Julien Leprovost
AlyXan, Centre Hoche, 3 Avenue Condorcet, 91260 Juvisy-sur-Orge, France
1 shared publication - Michel Heninger
Laboratoire de Chimie Physique, CNRS, Univ. Paris Sud, Université Paris Saclay, 91405 Orsay, France
1 shared publication
Latest Publications
- Open Access
Compact FTICR Mass Spectrometry for Real Time Monitoring of Volatile Organic Compounds
In this paper, we present a compact Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) designed for real time analysis of volatile organic compounds (VOCs) in air or in water. The spectrometer is based on a structured permanent magnet made with NdFeB segments. Chemical ionization is implemented inside the ICR cell. The most widely used reaction is the proton transfer reaction using H3O+ precursor ions, but other ionic precursors can be used to extend the range of species that can be detected. Complex mixtures are studied by switching automatically from one precursor to another. The accuracy obtained on the mass to charge ratio (Δm/z 5 × 10−3), allows a precise identification of the VOCs present and the limit of detection is 200 ppb without accumulation. The time resolution is a few seconds, mainly limited by the time necessary to come back to background pressure after the gas pulses. The real time measurement will be illustrated by the monitoring of VOCs produced during the thermal degradation of a polymer and by an example where three different precursor ions are used alternatively to monitor a gas sample.
Open AccessCompact FTICR Mass Spectrometry for Real Time Monitoring of Volatile Organic Compounds
In this paper, we present a compact Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) designed for real time analysis of volatile organic compounds (VOCs) in air or in water. The spectrometer is based on a structured permanent magnet made with NdFeB segments. Chemical ionization is implemented inside the ICR cell. The most widely used reaction is the proton transfer reaction using H3O+ precursor ions, but other ionic precursors can be used to extend the range of species that can be detected. Complex mixtures are studied by switching automatically from one precursor to another. The accuracy obtained on the mass to charge ratio (Δm/z 5 × 10−3), allows a precise identification of the VOCs present and the limit of detection is 200 ppb without accumulation. The time resolution is a few seconds, mainly limited by the time necessary to come back to background pressure after the gas pulses. The real time measurement will be illustrated by the monitoring of VOCs produced during the thermal degradation of a polymer and by an example where three different precursor ions are used alternatively to monitor a gas sample.