JJJi Hyun Jeong
Ji Hyun Jeong
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ji Hyun Jeong has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Bo Na Kim
National Development Institute of Korean Medicine, Udae land gil 288, Jangheung-gun, Jeollanam-do 59338, Republic of Korea
1 shared publication - Guk Yeo Lee
National Development Institute of Korean Medicine, Udae land gil 288, Jangheung-gun, Jeollanam-do 59338, Republic of Korea
1 shared publication - Seon Yu Lee
Department of Korean Medicinal Resource, Development Korean Medicinal Herbs Standardization Team, National Development Institute of Korean Medicine, Anyang-myeon, Jangheung-gun, Jeollanam-do, Republic of Korea
1 shared publication - Seong Ho Ham
National Development Institute of Korean Medicine, Udae land gil 288, Jangheung-gun, Jeollanam-do 59338, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 2 May 2018
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2018, 1-10
Development of Simultaneous Analysis of Thirteen Bioactive Compounds in So-Cheong-Ryong-Tang Using UPLC-DAD
So-Cheong-Ryong-Tang, which is a standardized Korean medicine of the National Health Insurance, is a traditional prescription for the treatment of allergic rhinitis, bronchitis, and bronchial asthma. Simultaneous analysis and development of SCRT is essential for its stability, efficacy, and risk management. In this study, a simple, reliable, and accurate method using ultrahigh-performance liquid chromatography (UPLC) fingerprinting with a diode array detector (DAD) was developed for the simultaneous analysis. The chromatographic separation of the analytes was performed by an ACQUITY UPLC BEH C18 column (1.7 M, 2.1 × 100 mm, Waters) with a mobile phase of water containing 0.01% (v/v) phosphoric acid and acetonitrile containing 0.01% (v/v) phosphoric acid. The flow rate and detection wavelength were set at 0.4 mL/min and 215, 230, 254, and 280 nm. All calibration curves of the thirteen components showed good linearity (R2 > 0.999). The limit of detection and limit of quantification ranged 0.001–0.360 and 0.004–1.200 µg/mL, respectively. The relative standard deviation (RSD) of intra- and interday was less than 2.60%, and the recoveries were within the range 76.08–103.79% with an RSD value of 0.03–1.50%. The results showed that the developed method was simple, reliable, accurate, sensitive, and precise for the quantification of bioactive components of SCRT.- 2 May 2018
- Published by Wiley in Journal of Analytical Methods in Chemistry
- Vol. 2018, 1-10
Open AccessDevelopment of Simultaneous Analysis of Thirteen Bioactive Compounds in So-Cheong-Ryong-Tang Using UPLC-DAD
So-Cheong-Ryong-Tang, which is a standardized Korean medicine of the National Health Insurance, is a traditional prescription for the treatment of allergic rhinitis, bronchitis, and bronchial asthma. Simultaneous analysis and development of SCRT is essential for its stability, efficacy, and risk management. In this study, a simple, reliable, and accurate method using ultrahigh-performance liquid chromatography (UPLC) fingerprinting with a diode array detector (DAD) was developed for the simultaneous analysis. The chromatographic separation of the analytes was performed by an ACQUITY UPLC BEH C18 column (1.7 M, 2.1 × 100 mm, Waters) with a mobile phase of water containing 0.01% (v/v) phosphoric acid and acetonitrile containing 0.01% (v/v) phosphoric acid. The flow rate and detection wavelength were set at 0.4 mL/min and 215, 230, 254, and 280 nm. All calibration curves of the thirteen components showed good linearity (R2 > 0.999). The limit of detection and limit of quantification ranged 0.001–0.360 and 0.004–1.200 µg/mL, respectively. The relative standard deviation (RSD) of intra- and interday was less than 2.60%, and the recoveries were within the range 76.08–103.79% with an RSD value of 0.03–1.50%. The results showed that the developed method was simple, reliable, accurate, sensitive, and precise for the quantification of bioactive components of SCRT.