DSDavid Sretavan

David Sretavan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Sretavan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Hyuck Choo

    Metaphotonics TU, Samsung Advanced Institute of Technology, Suwon, Republic of Korea

    3 shared publications
  • Jeong Oen Lee

    Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA

    2 shared publications
  • Juan Du

    Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, USA

    2 shared publications
  • Ashwin Balakrishna

    Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91106, USA

    1 shared publication
  • Blaise Ndjamen

    Department of Medical Engineering, California Institute of Technology, Pasadena, CA, USA

    1 shared publication
  • Haeri Park

    Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91106, USA

    1 shared publication

Latest Publications

  • Open Access

    Multifunctional biophotonic nanostructures inspired by the longtail glasswing butterfly for medical devices

    by Vinayak Narasimhan, Radwanul Hasan Siddique, Jeong Oen Lee, Shailabh Kumar, Blaise Ndjamen, Juan Du, Natalie Hong, David Sretavan, Hyuck Choo

    Numerous living organisms possess biophotonic nanostructures that provide colouration and other diverse functions for survival. While such structures have been actively studied and replicated in the laboratory, it remains unclear whether they can be used for biomedical applications. Here, we show a transparent photonic nanostructure inspired by the longtail glasswing butterfly (Chorinea faunus) and demonstrate its use in intraocular pressure (IOP) sensors in vivo. We exploit the phase separation between two immiscible polymers (poly(methyl methacrylate) and polystyrene) to form nanostructured features on top of a Si3N4 substrate. The membrane thus formed shows good angle-independent white-light transmission, strong hydrophilicity and anti-biofouling properties, which prevent adhesion of proteins, bacteria and eukaryotic cells. We then developed a microscale implantable IOP sensor using our photonic membrane as an optomechanical sensing element. Finally, we performed in vivo testing on New Zealand white rabbits, which showed that our device reduces the mean IOP measurement variation compared with conventional rebound tonometry without signs of inflammation.


  • Open Access

    A microscale optical implant for continuous in vivo monitoring of intraocular pressure

    by Jeong Oen Lee, Haeri Park, Juan Du, Ashwin Balakrishna, Oliver Chen, David Sretavan, Hyuck Choo

    Intraocular pressure (IOP) is a key clinical parameter in glaucoma management. However, despite the potential utility of daily measurements of IOP in the context of disease management, the necessary tools are currently lacking, and IOP is typically measured only a few times a year. Here we report on a microscale implantable sensor that could provide convenient, accurate, on-demand IOP monitoring in the home environment. When excited by broadband near-infrared (NIR) light from a tungsten bulb, the sensor’s optical cavity reflects a pressure-dependent resonance signature that can be converted to IOP. NIR light is minimally absorbed by tissue and is not perceived visually. The sensor’s nanodot-enhanced cavity allows for a 3–5 cm readout distance with an average accuracy of 0.29 mm Hg over the range of 0–40 mm Hg. Sensors were mounted onto intraocular lenses or silicone haptics and secured inside the anterior chamber in New Zealand white rabbits. Implanted sensors provided continuousin vivotracking of short-term transient IOP elevations and provided continuous measurements of IOP for up to 4.5 months.


  • Real-Time In Vivo Intraocular Pressure Monitoring Using an Optomechanical Implant and an Artificial Neural Network

    by Kun Ho Kim, Jeong Oen Lee, Juan Du, David Sretavan, Hyuck Choo

    Optimized glaucoma therapy requires frequent monitoring and timely lowering of elevated intraocular pressure (IOP). A recently developed microscale IOP-monitoring implant, when illuminated with broadband light, reflects a pressure-dependent optical spectrum that is captured and converted to measure IOP. However, its accuracy is limited by background noise and the difficulty of modeling non-linear shifts of the spectra with respect to pressure changes. Using an end-to-end calibration system to train an artificial neural network (ANN) for signal demodulation we improved the speed and accuracy of pressure measurements obtained with an optically probed IOP-monitoring implant and make it suitable for real-time in vivo IOP monitoring. The ANN converts captured optical spectra into corresponding IOP levels. We achieved an IOP-measurement accuracy of ±0.1 mmHg at a measurement rate of 100 Hz, which represents a ten-fold improvement from previously reported values. This technique allowed real-time tracking of artificially induced sub-1 s transient IOP elevations and minor fluctuations induced by the respiratory motion of the rabbits during in vivo monitoring. All in vivo sensor readings paralleled those obtained concurrently using a commercial tonometer and showed consistency within ±2 mmHg. Real-time processing is highly useful for IOP monitoring in clinical settings and home environments, and improves the overall practicality of the optical IOP-monitoring approach.