Yu Inaba
Yu Inaba has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Hideyuki Shimizu
Department of Cardiovascular Surgery, Keio University, Tokyo, Japan
19 shared publicationsTsutomu Ito
Department of Cardiovascular Surgery, Keio University, Shinjuku, Tokyo, Japan
10 shared publicationsKanako Hayashi
Department of Cardiovascular Surgery, Keio University, Shinjuku, Tokyo, Japan
7 shared publicationsTatsuo Takahashi
Department of Cardiovascular Surgery, Keio University, Shinjuku, Tokyo, Japan
6 shared publicationsAkihiro Yoshitake
Department of Cardiovascular surgery, Keio University School of Medicine, Tokyo, Japan
5 shared publicationsSachiko Hayashi
Department of Cardiovascular Surgery, Saiseikai Yokohamashi Tobu Hospital, Kanagawa, Japan
5 shared publications
Latest Publications
- Open Access
- 17 October 2022
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery Cases
- Vol. 1 (1) , 1-4
Blunt traumatic aortic injury to the brachiocephalic and left carotid arteries
Background: Blunt traumatic aortic injury (BTAI) is a life-threatening pathology that most commonly occurs after traffic accidents or a fall from a considerable height. We report a rare case of traumatic double transection which included the brachiocephalic artery (BCA) and left carotid artery (LCA) following a motorcycle accident.Case presentation: A 52-year-old man was brought to our emergency room for blunt trauma. Urgent computed tomography (CT) indicated BCA and LCA transection. Two weeks after the BTAI, CT indicated an increase in the size of the BCA pseudoaneurysm, a newly developed LCA pseudoaneurysm, and a spread of hematoma. An emergency partial aortic arch replacement including BCA and LCA reconstruction was performed 17 days after the BTAI. The postoperative course was good, and he was discharged 12 days later.Conclusions: An open aortic repair appeared to be more suited in the present case because the aortic injury occurred in a branched lesion of the aortic arch. It was thought that complete stent graft coverage of the transection lesion would be difficult. Although coexisting multiple system injuries complicate aortic repair, there was a rapid enlargement of the BCA and LCA pseudoaneurysms. Therefore, strict management is needed even in the case of cervical artery injury.
- 17 October 2022
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery Cases
- Vol. 1 (1) , 1-4
Open AccessBlunt traumatic aortic injury to the brachiocephalic and left carotid arteries
Background: Blunt traumatic aortic injury (BTAI) is a life-threatening pathology that most commonly occurs after traffic accidents or a fall from a considerable height. We report a rare case of traumatic double transection which included the brachiocephalic artery (BCA) and left carotid artery (LCA) following a motorcycle accident.Case presentation: A 52-year-old man was brought to our emergency room for blunt trauma. Urgent computed tomography (CT) indicated BCA and LCA transection. Two weeks after the BTAI, CT indicated an increase in the size of the BCA pseudoaneurysm, a newly developed LCA pseudoaneurysm, and a spread of hematoma. An emergency partial aortic arch replacement including BCA and LCA reconstruction was performed 17 days after the BTAI. The postoperative course was good, and he was discharged 12 days later.Conclusions: An open aortic repair appeared to be more suited in the present case because the aortic injury occurred in a branched lesion of the aortic arch. It was thought that complete stent graft coverage of the transection lesion would be difficult. Although coexisting multiple system injuries complicate aortic repair, there was a rapid enlargement of the BCA and LCA pseudoaneurysms. Therefore, strict management is needed even in the case of cervical artery injury.
- Open Access
- 10 August 2022
- Published by Japan College of Angiology in The Journal of Japanese College of Angiology
- Vol. 62 (8) , 67-71
Percutaneous Thoracic Endovascular Aortic Repair
Thoracic endovascular aortic repair(TEVAR)はシースサイズが大きいことからカットダウン法による外科的アプローチが多く行われている。しかしデバイスのlow profile化により,Preclosure ProGlideを用いたPercutaneous TEVAR(P-TEVAR)も行われるようになってきた。P-TEVARのメリットはカットダウン法による創部感染やリンパ漏,総大腿動脈(CFA: common femoral artery)縫合部狭窄が生じないことである。現在はCFAまでの距離,シースサイズを考慮して症例を限定しているが,将来的にP-TEVARを標準化するためにも更なる症例の蓄積が必要である。
- 10 August 2022
- Published by Japan College of Angiology in The Journal of Japanese College of Angiology
- Vol. 62 (8) , 67-71
Open AccessPercutaneous Thoracic Endovascular Aortic Repair
Thoracic endovascular aortic repair(TEVAR)はシースサイズが大きいことからカットダウン法による外科的アプローチが多く行われている。しかしデバイスのlow profile化により,Preclosure ProGlideを用いたPercutaneous TEVAR(P-TEVAR)も行われるようになってきた。P-TEVARのメリットはカットダウン法による創部感染やリンパ漏,総大腿動脈(CFA: common femoral artery)縫合部狭窄が生じないことである。現在はCFAまでの距離,シースサイズを考慮して症例を限定しているが,将来的にP-TEVARを標準化するためにも更なる症例の蓄積が必要である。
- 26 November 2021
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 70 (2) , 201-203
Native aortic valve thrombosis due to heparin-induced thrombocytopenia
A 65-year-old man with unstable angina was transferred to our department for coronary artery bypass grafting (CABG). Preoperative computed tomography indicated a large thrombosis in the left coronary cusp (LCC). CABG concomitant thrombectomy was performed under cardiopulmonary bypass using unfractionated heparin. Although the LCC was filled with a large thrombus, the left coronary artery ostium was not obstructed. The platelet count decreased by 68%, 12 days after starting heparin in the previous hospital. There is a high probability that this patient had HIT which was not recognized before surgery.
- 26 November 2021
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 70 (2) , 201-203
Native aortic valve thrombosis due to heparin-induced thrombocytopenia
A 65-year-old man with unstable angina was transferred to our department for coronary artery bypass grafting (CABG). Preoperative computed tomography indicated a large thrombosis in the left coronary cusp (LCC). CABG concomitant thrombectomy was performed under cardiopulmonary bypass using unfractionated heparin. Although the LCC was filled with a large thrombus, the left coronary artery ostium was not obstructed. The platelet count decreased by 68%, 12 days after starting heparin in the previous hospital. There is a high probability that this patient had HIT which was not recognized before surgery.
- 30 May 2021
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 25 (2) , 174-177
Surgical revision of failed MitraClip procedure for atrial functional mitral regurgitation
The MitraClip system is used for patients with severe mitral regurgitation (MR) who are at high risk for open surgery. However, some patients need surgical revision for various complications. The acute outcome of MitraClip treatment for atrial functional MR (aFMR) is scarcely reported. Herein, we describe a rare case of an 80-year-old woman treated with a MitraClip for aFMR with mitral annular dilatation and failed leaflet adaptation. The patient suffered from single leaflet device attachment (SLDA) and posterior leaflet injury 3 days posttreatment. The patient successfully underwent mitral valve replacement. The postoperative pulmonary hypertension was markedly improved and the left atrial volume was reduced. A MitraClip should be carefully used for aFMR with mitral annular dilatation and failed leaflet adaptation as it may cause SLDA.
- 30 May 2021
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 25 (2) , 174-177
Surgical revision of failed MitraClip procedure for atrial functional mitral regurgitation
The MitraClip system is used for patients with severe mitral regurgitation (MR) who are at high risk for open surgery. However, some patients need surgical revision for various complications. The acute outcome of MitraClip treatment for atrial functional MR (aFMR) is scarcely reported. Herein, we describe a rare case of an 80-year-old woman treated with a MitraClip for aFMR with mitral annular dilatation and failed leaflet adaptation. The patient suffered from single leaflet device attachment (SLDA) and posterior leaflet injury 3 days posttreatment. The patient successfully underwent mitral valve replacement. The postoperative pulmonary hypertension was markedly improved and the left atrial volume was reduced. A MitraClip should be carefully used for aFMR with mitral annular dilatation and failed leaflet adaptation as it may cause SLDA.
- 1 February 2021
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 71, 535.e7-535.e10
Dysphagia Aortica Caused by Congenitally Angulated Descending Aorta
- 1 February 2021
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 71, 535.e7-535.e10
Dysphagia Aortica Caused by Congenitally Angulated Descending Aorta
- 5 January 2021
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 69 (5) , 882-884
Aortic valve injury and complete atrioventricular block related to Impella device
The Impella device can effectively unload the left ventricle in patients undergoing high-risk percutaneous coronary intervention (PCI) and in cases of cardiogenic shock. Herein, we report a rare case of a 59-year-old man who was treated using PCI and the Impella CP for acute coronary syndrome. The patient suffered from severe acute aortic regurgitation and complete atrioventricular block (CAVB) with hemodynamic instability soon after the Impella removal. The non-coronary cusp (NCC) tear occurred from the NCC and right coronary cusp commissure to the middle of the NCC. The patient successfully underwent aortic valve replacement with no CAVB postoperatively.
- 5 January 2021
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 69 (5) , 882-884
Aortic valve injury and complete atrioventricular block related to Impella device
The Impella device can effectively unload the left ventricle in patients undergoing high-risk percutaneous coronary intervention (PCI) and in cases of cardiogenic shock. Herein, we report a rare case of a 59-year-old man who was treated using PCI and the Impella CP for acute coronary syndrome. The patient suffered from severe acute aortic regurgitation and complete atrioventricular block (CAVB) with hemodynamic instability soon after the Impella removal. The non-coronary cusp (NCC) tear occurred from the NCC and right coronary cusp commissure to the middle of the NCC. The patient successfully underwent aortic valve replacement with no CAVB postoperatively.
- Open Access
- 1 January 2021
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 14 (1) , 68-70
Aortic Dissection in Familial Patients with Autosomal Dominant Polycystic Kidney Disease
Autosomal dominant polycystic kidney disease (ADPKD) is the most common congenital kidney disease. However, reports on occasional cases of aortic dissection in PKD familial patients remain scarce. Herein, we describe rare aortic dissection cases in PKD familial patients (i.e., mother and daughter) and our successful treatment experience. The mother (84 years old) and daughter (53 years old) had a referral to us to treat type A acute aortic dissection. We performed emergency surgery and successfully treated the patients with an artificial graft. For comprehensive evaluation and treatment, ADPKD patients and their families should be screened for aortic diseases.
- 1 January 2021
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 14 (1) , 68-70
Open AccessAortic Dissection in Familial Patients with Autosomal Dominant Polycystic Kidney Disease
Autosomal dominant polycystic kidney disease (ADPKD) is the most common congenital kidney disease. However, reports on occasional cases of aortic dissection in PKD familial patients remain scarce. Herein, we describe rare aortic dissection cases in PKD familial patients (i.e., mother and daughter) and our successful treatment experience. The mother (84 years old) and daughter (53 years old) had a referral to us to treat type A acute aortic dissection. We performed emergency surgery and successfully treated the patients with an artificial graft. For comprehensive evaluation and treatment, ADPKD patients and their families should be screened for aortic diseases.
- 23 April 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 69 (1) , 91-93
Successful endovascular treatment of an ascending aortic pseudoaneurysm using an Amplatzer Vascular Plug II
Pseudoaneurysms are a rare complication of cardiovascular surgery, caused by disruption of the aortic structure (adventitia, media, and intima). Some reports have observed an extremely high mortality rate associated with the open surgical repair of pseudoaneurysms. In elderly or highly frail patients, the use of less invasive procedures is preferable. In this article, we report a case of an octogenarian who had a symptomatic ascending aortic pseudoaneurysm and a history of two sternotomies and present the successful treatment strategy. We treated the patient via an endovascular procedure using an Amplatzer Vascular Plug II (AVP II). After the intervention, the symptoms of the patient resolved. A computed tomography scan performed 1 year after the procedure confirmed the exclusion of the pseudoaneurysm.
- 23 April 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 69 (1) , 91-93
Successful endovascular treatment of an ascending aortic pseudoaneurysm using an Amplatzer Vascular Plug II
Pseudoaneurysms are a rare complication of cardiovascular surgery, caused by disruption of the aortic structure (adventitia, media, and intima). Some reports have observed an extremely high mortality rate associated with the open surgical repair of pseudoaneurysms. In elderly or highly frail patients, the use of less invasive procedures is preferable. In this article, we report a case of an octogenarian who had a symptomatic ascending aortic pseudoaneurysm and a history of two sternotomies and present the successful treatment strategy. We treated the patient via an endovascular procedure using an Amplatzer Vascular Plug II (AVP II). After the intervention, the symptoms of the patient resolved. A computed tomography scan performed 1 year after the procedure confirmed the exclusion of the pseudoaneurysm.
- 1 March 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 68 (3) , 248-253
No-touch saphenous vein graft harvesting technique for coronary artery bypass grafting
Objectives Although the patency of internal artery grafts in coronary artery bypass grafting (CABG) is superior to that of saphenous vein grafts (SVGs), good long-term patency rates have been reported with SVGs harvested using the no-touch technique. Here, we report the early results of CABG with no-touch SVGs (NT-SVGs) along with the precautions required while handling these grafts. Methods This retrospective study included 41 patients who underwent CABG with NT-SVGs between May 2016 and March 2018. NT-SVGs were harvested with minimal electric scalpel use, and post-harvesting vascular overdilation with a syringe was not performed. Blood with heparinized saline was used to prevent vascular endothelial damage. A drain was inserted into the SVG harvest site, which was closed with a single interrupted suture, and elasticated bandage and compression stockings were used to prevent fluid retention and avoid delayed wound healing. Results There was no case of postoperative thoracotomy due to bleeding or myocardial infarction, and postoperative graft assessment confirmed graft patency in all patients, with a little mismatch between the diameters of SVG and the anastomotic vessel. Delayed wound healing at the graft harvest site seemed to improve after introducing the above procedures. Conclusions Early results of CABG with NT-SVGs were good. Some precautions must be taken during harvesting and anastomosis. Taking precautions described in this study may help reduce the risk of perioperative complications and make the no-touch technique the standard procedure for harvesting SVGs for CABG.
- 1 March 2020
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- Vol. 68 (3) , 248-253
No-touch saphenous vein graft harvesting technique for coronary artery bypass grafting
Objectives Although the patency of internal artery grafts in coronary artery bypass grafting (CABG) is superior to that of saphenous vein grafts (SVGs), good long-term patency rates have been reported with SVGs harvested using the no-touch technique. Here, we report the early results of CABG with no-touch SVGs (NT-SVGs) along with the precautions required while handling these grafts. Methods This retrospective study included 41 patients who underwent CABG with NT-SVGs between May 2016 and March 2018. NT-SVGs were harvested with minimal electric scalpel use, and post-harvesting vascular overdilation with a syringe was not performed. Blood with heparinized saline was used to prevent vascular endothelial damage. A drain was inserted into the SVG harvest site, which was closed with a single interrupted suture, and elasticated bandage and compression stockings were used to prevent fluid retention and avoid delayed wound healing. Results There was no case of postoperative thoracotomy due to bleeding or myocardial infarction, and postoperative graft assessment confirmed graft patency in all patients, with a little mismatch between the diameters of SVG and the anastomotic vessel. Delayed wound healing at the graft harvest site seemed to improve after introducing the above procedures. Conclusions Early results of CABG with NT-SVGs were good. Some precautions must be taken during harvesting and anastomosis. Taking precautions described in this study may help reduce the risk of perioperative complications and make the no-touch technique the standard procedure for harvesting SVGs for CABG.
- Open Access
- 25 December 2019
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 12 (4) , 519-523
Effect of the Terminal Aortic Diameter on the Patency Rate of Iliac Limbs after Endovascular Aortic Repair
Objective: Endograft limb occlusion (ELO) is a complication of endovascular aneurysm repair (EVAR). In this study, we investigated the mechanism and anatomical features of ELO.Materials and Methods: We retrospectively reviewed 227 consecutive patients with abdominal aortic aneurysm who underwent EVAR between 2007 and 2017. We then analyzed the preoperative risk factors and anatomical features of patients with ELO.Results: A total of nine patients had ELO (4.0%). The diameter of the terminal aorta was significantly smaller in patients with ELO than in patients without ELO (18.0 mm vs. 22.3 mm, p=0.039). We measured the diameter of each limb near the terminal aorta. The smaller limb (SL) was occluded in all patients with occlusion. The difference between the larger limb (LL) and the SL (LL-SL) was significantly larger in patients with ELO than in patients without ELO (4.0 mm vs. 1.7 mm, p<0.001). The following were considered risk factors for ELO: younger age, narrow terminal aorta, severe calcification at the terminal aorta, and use of an Endurant device.Conclusion: ELO occurs when the diameter of one side of the stent graft limb is small compared with the diameter of the other side owing to the narrow terminal aorta and calcification.
- 25 December 2019
- Published by The Editorial Committee of Annals of Vascular Diseases in Annals of Vascular Diseases
- Vol. 12 (4) , 519-523
Open AccessEffect of the Terminal Aortic Diameter on the Patency Rate of Iliac Limbs after Endovascular Aortic Repair
Objective: Endograft limb occlusion (ELO) is a complication of endovascular aneurysm repair (EVAR). In this study, we investigated the mechanism and anatomical features of ELO.Materials and Methods: We retrospectively reviewed 227 consecutive patients with abdominal aortic aneurysm who underwent EVAR between 2007 and 2017. We then analyzed the preoperative risk factors and anatomical features of patients with ELO.Results: A total of nine patients had ELO (4.0%). The diameter of the terminal aorta was significantly smaller in patients with ELO than in patients without ELO (18.0 mm vs. 22.3 mm, p=0.039). We measured the diameter of each limb near the terminal aorta. The smaller limb (SL) was occluded in all patients with occlusion. The difference between the larger limb (LL) and the SL (LL-SL) was significantly larger in patients with ELO than in patients without ELO (4.0 mm vs. 1.7 mm, p<0.001). The following were considered risk factors for ELO: younger age, narrow terminal aorta, severe calcification at the terminal aorta, and use of an Endurant device.Conclusion: ELO occurs when the diameter of one side of the stent graft limb is small compared with the diameter of the other side owing to the narrow terminal aorta and calcification.