Cátia Tavares
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cátia Tavares has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Antunes
Institute for Nanostructures, Nanomodelling & Nanofabrication (i3N) and Physics Department, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
11 shared publications - Maria Fatima Domingues
Department of Bioengineering and Instituto de Telecomunicações‐Instituto Superior Técnico University of Lisbon Lisbon Portugal
9 shared publications - Nélia Alberto
Instituto de Telecomunicações, University of Aveiro, Campus Universitário de Santiago, 3810-193 Aveiro, Portugal
9 shared publications - Ayman Radwan
Department of Electrical and Computer Engineering (DEEC) and Instituto de Telecomunicaes, Instituto Superior Tcnico, University of Lisbon, Lisbon, Portugal
4 shared publications - Cátia Leitão
Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N—Aveiro), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal
4 shared publications - Hugo Plácido da Silva
Instituto de Telecomunicações, Instituto Superior Técnico, 1049-001 Lisbon, Portugal
4 shared publications
Latest Publications
- Open Access
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 50497-50509
Smart Office Chair for Working Conditions Optimization
There is a growing tendency for people to spend more and more hours of their day sitting. This position leads to an increase in the postural problems in the population. For workers who have to spend long hours at work, in a seated position, investment should be directed towards the development of equipment that improves their working conditions, such as smart instrumented chairs with warnings of changes in position. With this work we propose a standard office chair instrumentation approach, designed to allow monitoring physiological parameters such as: posture of the seated person (user); body temperature; and respiratory frequency. The system also allows monitoring environmental parameters such as: temperature; relative humidity; atmospheric concentration of carbon dioxide (CO 2 ); noise; and light levels. The chair enables the interaction with control equipment to adjust the comfort level, advising the need for rest time, repositioning notifications, and the real time visualization of data, using applications for Windows and Android. The system was tested by six users and evaluated in the detection of six different postures for each user, while sitting on the chair, presenting an 100% accuracy on the posture detection and a maximum of 18% error on the physiological parameters sensing. Experimental results show the adequate functionality of the instrumented chair, which could contribute to the prevention of pathologies associated with improper posture and the improvement of work productivity.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 50497-50509
Open AccessSmart Office Chair for Working Conditions Optimization
There is a growing tendency for people to spend more and more hours of their day sitting. This position leads to an increase in the postural problems in the population. For workers who have to spend long hours at work, in a seated position, investment should be directed towards the development of equipment that improves their working conditions, such as smart instrumented chairs with warnings of changes in position. With this work we propose a standard office chair instrumentation approach, designed to allow monitoring physiological parameters such as: posture of the seated person (user); body temperature; and respiratory frequency. The system also allows monitoring environmental parameters such as: temperature; relative humidity; atmospheric concentration of carbon dioxide (CO 2 ); noise; and light levels. The chair enables the interaction with control equipment to adjust the comfort level, advising the need for rest time, repositioning notifications, and the real time visualization of data, using applications for Windows and Android. The system was tested by six users and evaluated in the detection of six different postures for each user, while sitting on the chair, presenting an 100% accuracy on the posture detection and a maximum of 18% error on the physiological parameters sensing. Experimental results show the adequate functionality of the instrumented chair, which could contribute to the prevention of pathologies associated with improper posture and the improvement of work productivity.
- Open Access
- 13 October 2022
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 266, 04002
3D printed FBG based sensor for vital signal monitoring – Influence of the infill printing parameters
The fused deposition modelling technique has been used in the production of strain sensors in which fibre Bragg gratings (FBGs) are encapsulated during the 3D printing process. This paper reports the study of the influence of the FBG position and the material filling, in this case a flexible polymer material, on the sensors’ sensitivity and overall performance. In addition, this study preliminarily evaluated the ability of the strain sensor to monitor (heart rate) HR and (respiratory rate) RR as a wearable on the wrist and as a non-intrusive solution on the back of an office chair.
- 13 October 2022
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 266, 04002
Open Access3D printed FBG based sensor for vital signal monitoring – Influence of the infill printing parameters
The fused deposition modelling technique has been used in the production of strain sensors in which fibre Bragg gratings (FBGs) are encapsulated during the 3D printing process. This paper reports the study of the influence of the FBG position and the material filling, in this case a flexible polymer material, on the sensors’ sensitivity and overall performance. In addition, this study preliminarily evaluated the ability of the strain sensor to monitor (heart rate) HR and (respiratory rate) RR as a wearable on the wrist and as a non-intrusive solution on the back of an office chair.
- Open Access
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (20) , 19357-19365
The Effect of Infill Pattern and Density on the Response of 3-D-Printed Sensors Based on FBG Technology
Fiber Bragg gratings (FBGs) are known for their uses in applications ranging from civil engineering to medicine. A bare FBG is small and light, hence can be easily embedded into hosting materials. However, conventional fabrication methods are generally time-consuming with reproducibility issues. A more recent strategy has been proposed to develop novel FBG-based systems by encapsulating the grating within 3-dimensional (3D) printed structures. This process, known as 3D printing, is characterized by several advantages like rapid prototyping, printing precision, and high customization. The possibility of quickly personalizing the 3D printed sensors by customizing the infill settings makes this technique very appealing for medical purposes, especially for developing smart systems. However, the influence of printing settings on the sensor response has not been yet systematically addressed. This work aimed at combining FBG with the most popular 3D printing technique (the fused deposition modeling - FDM) to develop four 3D-printed sensors with different printing profiles. We chose two patterns (triangle and gyroid) and two infill densities (30% and 60%) to investigate their influence on the sensors response to strain, temperature, relative humidity, and on the hysteresis behavior. Then, we preliminary assess the sensor performance in a potential application scenario for FBG-based 3D printing technology: the cardiorespiratory monitoring. The promising results confirm that our analysis can be considered the first effort to improve the knowledge about the influence of printing profiles on sensor performance and, consequently, pave the way to develop highly performant 3D-printed sensors customized for specific applications.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (20) , 19357-19365
Open AccessThe Effect of Infill Pattern and Density on the Response of 3-D-Printed Sensors Based on FBG Technology
Fiber Bragg gratings (FBGs) are known for their uses in applications ranging from civil engineering to medicine. A bare FBG is small and light, hence can be easily embedded into hosting materials. However, conventional fabrication methods are generally time-consuming with reproducibility issues. A more recent strategy has been proposed to develop novel FBG-based systems by encapsulating the grating within 3-dimensional (3D) printed structures. This process, known as 3D printing, is characterized by several advantages like rapid prototyping, printing precision, and high customization. The possibility of quickly personalizing the 3D printed sensors by customizing the infill settings makes this technique very appealing for medical purposes, especially for developing smart systems. However, the influence of printing settings on the sensor response has not been yet systematically addressed. This work aimed at combining FBG with the most popular 3D printing technique (the fused deposition modeling - FDM) to develop four 3D-printed sensors with different printing profiles. We chose two patterns (triangle and gyroid) and two infill densities (30% and 60%) to investigate their influence on the sensors response to strain, temperature, relative humidity, and on the hysteresis behavior. Then, we preliminary assess the sensor performance in a potential application scenario for FBG-based 3D printing technology: the cardiorespiratory monitoring. The promising results confirm that our analysis can be considered the first effort to improve the knowledge about the influence of printing profiles on sensor performance and, consequently, pave the way to develop highly performant 3D-printed sensors customized for specific applications.
- Open Access
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 69063-69071
Instrumented Office Chair With Low-Cost Plastic Optical Fiber Sensors for Posture Control and Work Conditions Optimization
People spend more and more time sitting and this habit has been shown to cause spine pathologies. Thus, the scientific community and the industry have become interested in instrumented chairs development to detect incorrect user postures. In this work we present the development and implementation of invisibles and non-intrusive plastic optical fiber sensor cells to monitor the posture and evaluate the ergonomic behavior of a seated person. The low-cost plastic optical fiber (POF) based sensing devices developed in this work, were implemented in an office chair, to evaluate the workers posture throughout their work day. In addition to the sensors, Android and PC software applications were developed, to provide real time feedback and alerts to the user whenever an inadequate posture is detected, or the seating position is the same for a long time. The proposed approach was evaluated in a study involving six users, and results show that it can detect the user’s position with 96.6% accuracy.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 69063-69071
Open AccessInstrumented Office Chair With Low-Cost Plastic Optical Fiber Sensors for Posture Control and Work Conditions Optimization
People spend more and more time sitting and this habit has been shown to cause spine pathologies. Thus, the scientific community and the industry have become interested in instrumented chairs development to detect incorrect user postures. In this work we present the development and implementation of invisibles and non-intrusive plastic optical fiber sensor cells to monitor the posture and evaluate the ergonomic behavior of a seated person. The low-cost plastic optical fiber (POF) based sensing devices developed in this work, were implemented in an office chair, to evaluate the workers posture throughout their work day. In addition to the sensors, Android and PC software applications were developed, to provide real time feedback and alerts to the user whenever an inadequate posture is detected, or the seating position is the same for a long time. The proposed approach was evaluated in a study involving six users, and results show that it can detect the user’s position with 96.6% accuracy.
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (13) , 12886-12893
FBGs Based System for Muscle Effort Monitoring in Wheelchair Users
Numerous studies have been carried out aiming to improve wheelchair users’ quality of life. Based on the muscle effort evaluation during their daily activities, wheelchair users can adopt different postures to reduce their effort. However, most of the current solutions for muscle effort assessment are affected by uncontrolled factors. Here, a solution immune to these factors is proposed. The system, based on six fiber Bragg gratings embedded in epoxy resin, was distributed on both arms of six wheelchair users’ volunteers. The arms’ muscle effort was estimated through the fiber Bragg grating’s wavelength shift, which was related with the epoxy resin deformation during some of the wheelchair users’ daily movements, such as horizontal plane locomotion (using different wheelchair hand movement patterns), ramp up and down, and dips. The slightest hand clearance, in relation to the rim (pattern A), implies smaller sensor deformations and, therefore, a lower effort. Comparing to pattern A, volunteer 5 increased 17% its effort in pattern B and 27% in pattern D, in the left bicep sensor. Also, ramp displacements require higher muscle effort, in relation to the horizontal plane. Of all the exercises performed, dips involve the most intense arms’ muscle effort (volunteer 5 had an 82% deformation increase, comparing to pattern A, in the left bicep sensor). The developed system revealed promising results, providing deeper knowledge about the muscle effort during daily movements. Based on this information they can adopt different postures, resulting in minor muscle fatigue, and consequently an improvement of their quality of life.
- 1 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (13) , 12886-12893
FBGs Based System for Muscle Effort Monitoring in Wheelchair Users
Numerous studies have been carried out aiming to improve wheelchair users’ quality of life. Based on the muscle effort evaluation during their daily activities, wheelchair users can adopt different postures to reduce their effort. However, most of the current solutions for muscle effort assessment are affected by uncontrolled factors. Here, a solution immune to these factors is proposed. The system, based on six fiber Bragg gratings embedded in epoxy resin, was distributed on both arms of six wheelchair users’ volunteers. The arms’ muscle effort was estimated through the fiber Bragg grating’s wavelength shift, which was related with the epoxy resin deformation during some of the wheelchair users’ daily movements, such as horizontal plane locomotion (using different wheelchair hand movement patterns), ramp up and down, and dips. The slightest hand clearance, in relation to the rim (pattern A), implies smaller sensor deformations and, therefore, a lower effort. Comparing to pattern A, volunteer 5 increased 17% its effort in pattern B and 27% in pattern D, in the left bicep sensor. Also, ramp displacements require higher muscle effort, in relation to the horizontal plane. Of all the exercises performed, dips involve the most intense arms’ muscle effort (volunteer 5 had an 82% deformation increase, comparing to pattern A, in the left bicep sensor). The developed system revealed promising results, providing deeper knowledge about the muscle effort during daily movements. Based on this information they can adopt different postures, resulting in minor muscle fatigue, and consequently an improvement of their quality of life.
- 21 March 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (4) , 2299-2311
Respiratory and heart rate monitoring using an FBG 3D-printed wearable system
This work proposes a 3D-printed sensor based on fiber Bragg grating (FBG) technology for respiratory rate (RR) and heart rate (HR) monitoring. Each sensor is composed of a single FBG fully encapsulated into a 3D-printable Flexible, during the printing process. Sensors with different material thicknesses and infill densities were tested. The sensor with the best metrological properties was selected and preliminary assessed in terms of capability of monitoring RR and HR on three users. Preliminary results proved that the developed sensor can be a valuable easy-to-fabricate solution, with high reproducibility and high strain sensitivity to chest wall deformations due to breathing and heart beating.
- 21 March 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (4) , 2299-2311
Respiratory and heart rate monitoring using an FBG 3D-printed wearable system
This work proposes a 3D-printed sensor based on fiber Bragg grating (FBG) technology for respiratory rate (RR) and heart rate (HR) monitoring. Each sensor is composed of a single FBG fully encapsulated into a 3D-printable Flexible, during the printing process. Sensors with different material thicknesses and infill densities were tested. The sensor with the best metrological properties was selected and preliminary assessed in terms of capability of monitoring RR and HR on three users. Preliminary results proved that the developed sensor can be a valuable easy-to-fabricate solution, with high reproducibility and high strain sensitivity to chest wall deformations due to breathing and heart beating.
- Open Access
- 15 February 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (4) , 2195
Sensor Cell Network for Pressure, Temperature and Position Detection on Wheelchair Users
This work proposes an optical sensing network to monitor pressure and temperature in specific areas of a wheelchair to prevent pressure ulcers and to monitor the position of the wheelchair user by analyzing its pressure distribution. The sensing network is composed of six optical fiber Bragg grating (FBG)-based sensor cells. Each sensor cell is built from a polylactic acid (PLA) base and has two FBGs, one embedded in epoxy resin to monitor pressure variations (FBGP) and another without resin to monitor temperature (FBGT). Once produced, all sensor cells were experimentally characterized for pressure and temperature variations, resulting in an average pressure sensitivity of 81 ± 5 pm/kPa (FBGP) and −5.0 ± 0.4 pm/kPa (FBGT), and an average temperature sensitivity of 25 ± 1 pm/°C (FBGP) and 47.7 ± 0.7 pm/°C (FBGT). The sensor cells were then placed in six specific areas of a wheelchair (four in the seat area and two in the shoulder blade area) to carry out experimental tests, wherein the response of the sensors to a specific sequence of relief positions was tested. During the execution of the test, the optical signal of all sensors was monitored, in real time, with the pressure and temperature values detected in each zone of the wheelchair. In addition, random position changes were performed in order to evaluate the precision of the proposed sensing network in the identification of such positions.
- 15 February 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (4) , 2195
Open AccessSensor Cell Network for Pressure, Temperature and Position Detection on Wheelchair Users
This work proposes an optical sensing network to monitor pressure and temperature in specific areas of a wheelchair to prevent pressure ulcers and to monitor the position of the wheelchair user by analyzing its pressure distribution. The sensing network is composed of six optical fiber Bragg grating (FBG)-based sensor cells. Each sensor cell is built from a polylactic acid (PLA) base and has two FBGs, one embedded in epoxy resin to monitor pressure variations (FBGP) and another without resin to monitor temperature (FBGT). Once produced, all sensor cells were experimentally characterized for pressure and temperature variations, resulting in an average pressure sensitivity of 81 ± 5 pm/kPa (FBGP) and −5.0 ± 0.4 pm/kPa (FBGT), and an average temperature sensitivity of 25 ± 1 pm/°C (FBGP) and 47.7 ± 0.7 pm/°C (FBGT). The sensor cells were then placed in six specific areas of a wheelchair (four in the seat area and two in the shoulder blade area) to carry out experimental tests, wherein the response of the sensors to a specific sequence of relief positions was tested. During the execution of the test, the optical signal of all sensors was monitored, in real time, with the pressure and temperature values detected in each zone of the wheelchair. In addition, random position changes were performed in order to evaluate the precision of the proposed sensing network in the identification of such positions.
- Open Access
- 23 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 132480-132490
Optically Instrumented Insole for Gait Plantar and Shear Force Monitoring
In this work, a fiber Bragg gratings (FBGs) based sensing insole, capable of simultaneously measure plantar force (PF) and shear force (SF) is proposed. The insole has four measuring points, strategically located for a full gait analysis. Each sensing point contains a sensor-cell which consists in a polylactic acid (PLA) structure, covered by an epoxy resin layer, and crossed by one optical fiber with two FBGs, FBG1 and FBG2, respectively. Due to the specific design of the system, the FBG1 is sensitive to both forces (with higher sensitivity to the PF), while the FBG2 is designed to detect only the SF. The instrumented insole was tested during static and gait exercises, and the results, obtained for the PF and SF monitoring, were according with those theoretically expected.
- 23 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 132480-132490
Open AccessOptically Instrumented Insole for Gait Plantar and Shear Force Monitoring
In this work, a fiber Bragg gratings (FBGs) based sensing insole, capable of simultaneously measure plantar force (PF) and shear force (SF) is proposed. The insole has four measuring points, strategically located for a full gait analysis. Each sensing point contains a sensor-cell which consists in a polylactic acid (PLA) structure, covered by an epoxy resin layer, and crossed by one optical fiber with two FBGs, FBG1 and FBG2, respectively. Due to the specific design of the system, the FBG1 is sensitive to both forces (with higher sensitivity to the PF), while the FBG2 is designed to detect only the SF. The instrumented insole was tested during static and gait exercises, and the results, obtained for the PF and SF monitoring, were according with those theoretically expected.
- Open Access
Wheelchair Pressure Ulcer Prevention Using FBG Based Sensing Devices
In this work, a fiber Bragg grating (FBG) based sensing system for wheelchair pressure ulcer prevention was developed. Six FBGs were strategically positioned in a wheelchair to monitor the more prominent bone areas, namely scapulas (right (SR) and left (SL)), ischiatic zone (right (IR) and left (IL)), and heels (right (HR) and left (HL)). The sensing architecture was tested by a female user during pressure relief exercises, to verify its effectiveness on pressure monitoring. The proposed system proves to be a compact and reliable solution for wheelchair pressure ulcer prevention, making it a suitable alternative to existing conventional electronic sensors, with the advantage of being immune to electromagnetic interferences and usable in humid environments. In addition to the pressure, the breathing rate was also monitored. By combining the proposed sensing architecture with a wheelchair user detection software, it is possible to create alerts for the user to know when a new position should be adopted, in order to relieve the pressure in a specific area, thus avoiding one of the biggest problems for such patients, pressure ulcers.
Open AccessWheelchair Pressure Ulcer Prevention Using FBG Based Sensing Devices
In this work, a fiber Bragg grating (FBG) based sensing system for wheelchair pressure ulcer prevention was developed. Six FBGs were strategically positioned in a wheelchair to monitor the more prominent bone areas, namely scapulas (right (SR) and left (SL)), ischiatic zone (right (IR) and left (IL)), and heels (right (HR) and left (HL)). The sensing architecture was tested by a female user during pressure relief exercises, to verify its effectiveness on pressure monitoring. The proposed system proves to be a compact and reliable solution for wheelchair pressure ulcer prevention, making it a suitable alternative to existing conventional electronic sensors, with the advantage of being immune to electromagnetic interferences and usable in humid environments. In addition to the pressure, the breathing rate was also monitored. By combining the proposed sensing architecture with a wheelchair user detection software, it is possible to create alerts for the user to know when a new position should be adopted, in order to relieve the pressure in a specific area, thus avoiding one of the biggest problems for such patients, pressure ulcers.
- Open Access
High Rate Dynamic Monitoring with Fabry–Perot Interferometric Sensors: An Alternative Interrogation Technique Targeting Biomedical Applications
Fabry–Perot interferometric (FPI) sensors are an accurate and well-established sensing technology that are used to monitor a wide range of parameters such as strain, temperature, and refractive index, among many others. Nevertheless, due to the limited number and high cost of existing interrogation techniques for FPIs, its use is often restricted to discrete measurements, not being so explored for dynamic applications. The development of an alternative interrogation technique for a high rate of acquisition may propel this type of sensor into less explored fields such as dynamic biomedical applications. In this work, we present the theoretical and experimental analyses of an FPI sensing architecture by using an alternative high rate dynamic acquisition methodology, based on frequency to amplitude conversion, where the FPI spectral shift is detuned by the convolution of the optical light source with the FPI interference pattern. The good agreement between the theoretical and experimental results verified the reliability of the proposed methodology. Moreover, preliminary results show that the developed sensing architecture can be a suitable solution to monitor biomedical parameters such as the carotid pulse wave.
Open AccessHigh Rate Dynamic Monitoring with Fabry–Perot Interferometric Sensors: An Alternative Interrogation Technique Targeting Biomedical Applications
Fabry–Perot interferometric (FPI) sensors are an accurate and well-established sensing technology that are used to monitor a wide range of parameters such as strain, temperature, and refractive index, among many others. Nevertheless, due to the limited number and high cost of existing interrogation techniques for FPIs, its use is often restricted to discrete measurements, not being so explored for dynamic applications. The development of an alternative interrogation technique for a high rate of acquisition may propel this type of sensor into less explored fields such as dynamic biomedical applications. In this work, we present the theoretical and experimental analyses of an FPI sensing architecture by using an alternative high rate dynamic acquisition methodology, based on frequency to amplitude conversion, where the FPI spectral shift is detuned by the convolution of the optical light source with the FPI interference pattern. The good agreement between the theoretical and experimental results verified the reliability of the proposed methodology. Moreover, preliminary results show that the developed sensing architecture can be a suitable solution to monitor biomedical parameters such as the carotid pulse wave.