CLChengmin Lin

Chengmin Lin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengmin Lin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Chengchao Wu

    School of Electronic Engineering, Xi’an University of Posts and Telecommunications, Xi’an, China

    1 shared publication
  • Chenxi Wang

    Department of Orthopaedics Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases Shanghai Institute of Traumatology and Orthopaedics Ruijin Hospital Shanghai Jiao Tong University School of Medicine Shanghai China

    1 shared publication
  • He Xie

    Hunan University

    1 shared publication
  • Jiewei Jiang

    School of Electronic Engineering, Xi’an University of Posts and Telecommunications, Xi’an 710121, China

    1 shared publication
  • Jinglu Ying

    Department of Ophthalmology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou 310016, China

    1 shared publication
  • Mingguang Shi

    Department of Ophthalmology, the Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325027, China

    1 shared publication

Latest Publications

  • Open Access

    Deep learning for detecting visually impaired cataracts using fundus images

    by He Xie, Zhongwen Li, Chengchao Wu, Yitian Zhao, Chengmin Lin, Zhouqian Wang, Chenxi Wang, Qinyi Gu, Minye Wang, Qinxiang Zheng, et al.

    Purpose: To develop a visual function-based deep learning system (DLS) using fundus images to screen for visually impaired cataracts.Materials and methods: A total of 8,395 fundus images (5,245 subjects) with corresponding visual function parameters collected from three clinical centers were used to develop and evaluate a DLS for classifying non-cataracts, mild cataracts, and visually impaired cataracts. Three deep learning algorithms (DenseNet121, Inception V3, and ResNet50) were leveraged to train models to obtain the best one for the system. The performance of the system was evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity.Results: The AUC of the best algorithm (DenseNet121) on the internal test dataset and the two external test datasets were 0.998 (95% CI, 0.996–0.999) to 0.999 (95% CI, 0.998–1.000),0.938 (95% CI, 0.924–0.951) to 0.966 (95% CI, 0.946–0.983) and 0.937 (95% CI, 0.918–0.953) to 0.977 (95% CI, 0.962–0.989), respectively. In the comparison between the system and cataract specialists, better performance was observed in the system for detecting visually impaired cataracts (p < 0.05).Conclusion: Our study shows the potential of a function-focused screening tool to identify visually impaired cataracts from fundus images, enabling timely patient referral to tertiary eye hospitals.


  • Open Access

    Group Analysis ofQValues Calculated with Tangential Radius of Curvature from Human Anterior Corneal Surface

    by Zheren Xia, Chengmin Lin, Xueping Huang, Jinglu Ying, Mingguang Shi, Suilian Zheng

    Objective. To calculate theQvalues from the human anterior corneal surface with the tangential radius of curvature and analyze its distribution characteristics in different age and refractive status groups.Methods. Tangential power maps of the anterior cornea from Orbscan II were acquired for 201 subjects’ right eyes. They were divided into groups of adults and children and then divided further into subgroups according to the refraction status. TheQvalues of each semimeridian were calculated by the tangential radius with a linear regression equation. TheQvalue distribution in both the nasal cornea and temporal cornea were analyzed.Results. The mean temporalQvalues of the emmetropia group of adults and all children’s groups were significantly different from the mean nasalQvalue. The mean nasal cornealQvalues were more negative in children. The adult group showed differences only in the low myopia group. The meanQvalue of the nasal cornea among different refractive groups of children was significantly different, and so was the temporal cornea between the adult myopia and emmetropia group.Conclusion. The method using the tangential radius of curvature combined with linear regression to obtain anterior surfaceQvalues for both adults and children was stable and reliable. When we analyzed the anterior cornealQvalue, area division was necessary.