Michelle Armenta Salas
Research Subjects
Michelle Armenta Salas has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Soroush Niketeghad
Department of Neurosurgery, University of California Los Angeles, CA, Los Angeles
2 shared publications- Spencer Kellis
Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, USA
2 shared publications - Timothy D. Girard
Center for Research, Investigation, and Systems Modeling of Acute Illness (CRISMA) in the Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA
2 shared publications Annie Zhang
Ceribell, Inc. Sunnyvale, CA
1 shared publicationArup Roy
Second Sight Medical Products, Inc., Sylmar, CA, 91342, USA
1 shared publication- Avi Caspi
Jerusalem College of Technology, Jerusalem, Israel
1 shared publication
Latest Publications
- Open Access
Validation of an EEG-based Delirium Monitor in the ICU
Purpose: Delirium affects around 40% of intensive care unit (ICU) patients and adversely affects survival, length of stay, and cognitive recovery. Despite this, implementation of systematic clinical delirium assessments is variable. We sought to validate a point-of-care electroencephalography (EEG)-based system (Ceribell, Inc.) for the detection of delirium in the ICU. Methods: In this multicenter, prospective cohort study, we monitored adult ICU patients with the Ceribell EEG system for 6-8 hours for a minimum of three days. Up to three times per day, expert clinicians assessed participants for delirium and research coordinators completed Confusion Assessment Method for the ICU (CAM-ICU) assessments, which we used to calculate CAM-ICU-7 severity scores. We compared expert clinician diagnoses with Ceribell EEG algorithm output using data from 30-minute periods surrounding each clinician assessment. Results: Among 225 participants analyzed (median age: 64 years, 60% male, 21% mechanically ventilated), expert clinicians performed 857 assessments and found 24% of participants were delirious during at least one assessment. The Ceribell EEG system detected delirium with a sensitivity of 81% (95% CI: 76% to 87%) and specificity of 81% (95% CI: 78% to 84%). The continuous Ceribell EEG system score correlated with CAM-ICU-7 delirium severity scores (bootstrapped median rho 0.58, IQR: 0.54-0.62, p <0.001). Conclusion: In a mixed adult ICU population, the Ceribell EEG system identified delirium with good sensitivity and specificity. Its continuous output was associated with delirium severity, highlighting its potential ability to characterize underlying physiological patterns across the clinical delirium spectrum.
Open AccessValidation of an EEG-based Delirium Monitor in the ICU
Purpose: Delirium affects around 40% of intensive care unit (ICU) patients and adversely affects survival, length of stay, and cognitive recovery. Despite this, implementation of systematic clinical delirium assessments is variable. We sought to validate a point-of-care electroencephalography (EEG)-based system (Ceribell, Inc.) for the detection of delirium in the ICU. Methods: In this multicenter, prospective cohort study, we monitored adult ICU patients with the Ceribell EEG system for 6-8 hours for a minimum of three days. Up to three times per day, expert clinicians assessed participants for delirium and research coordinators completed Confusion Assessment Method for the ICU (CAM-ICU) assessments, which we used to calculate CAM-ICU-7 severity scores. We compared expert clinician diagnoses with Ceribell EEG algorithm output using data from 30-minute periods surrounding each clinician assessment. Results: Among 225 participants analyzed (median age: 64 years, 60% male, 21% mechanically ventilated), expert clinicians performed 857 assessments and found 24% of participants were delirious during at least one assessment. The Ceribell EEG system detected delirium with a sensitivity of 81% (95% CI: 76% to 87%) and specificity of 81% (95% CI: 78% to 84%). The continuous Ceribell EEG system score correlated with CAM-ICU-7 delirium severity scores (bootstrapped median rho 0.58, IQR: 0.54-0.62, p <0.001). Conclusion: In a mixed adult ICU population, the Ceribell EEG system identified delirium with good sensitivity and specificity. Its continuous output was associated with delirium severity, highlighting its potential ability to characterize underlying physiological patterns across the clinical delirium spectrum.
- Open Access
Current Gaps in Delirium Recognition and Management: A Cross-Sectional Survey of ICU Physician and Nurse Leaders
BACKGROUND: Delirium is common in critically ill adults but often goes unrecognized and undertreated. Little is known about the perceptions of ICU nurse and physician leaders regarding ICU delirium detection and management and the potential role of objective continuous delirium monitoring to facilitate ICU delirium care. RESEARCH QUESTION: What are the perceptions of ICU leaders regarding the current challenges associated with delirium recognition and management and the potential benefits of continuous delirium monitoring? STUDY DESIGN AND METHODS: We conducted a blinded, cross-sectional, electronic survey of ICU leaders across the U.S., including physician directors and nursing managers with ≥3 years of ICU leadership experience. We asked about perceptions of the effectiveness of current delirium clinical assessment tools, current delirium detection and management challenges, and how an objective, continuous delirium monitoring system might impact clinician practice and patient outcomes in their ICU. RESULTS: Among the 81 respondents (62 physicians, 19 nurses), most (76%) reported that recommended delirium assessment tools (CAM-ICU, ICDSC) are used in their ICUs, though there were mixed perceptions on how reliably they are conducted. A majority (63-90%) perceived that current bedside assessments delay and limit the recognition of ICU delirium. Nearly all (89%) agreed an objective delirium monitoring tool would be more clinically valuable than current delirium assessment tools and that it would support real-time, delirium management by clinicians. CONCLUSIONS: ICU leaders perceive that there are limitations to using clinical delirium assessment tools in ICU patients to effectively detect and manage ICU delirium. Most felt that an objective delirium monitor could facilitate delirium detection and potentially expedite appropriate delirium management in patients.
Open AccessCurrent Gaps in Delirium Recognition and Management: A Cross-Sectional Survey of ICU Physician and Nurse Leaders
BACKGROUND: Delirium is common in critically ill adults but often goes unrecognized and undertreated. Little is known about the perceptions of ICU nurse and physician leaders regarding ICU delirium detection and management and the potential role of objective continuous delirium monitoring to facilitate ICU delirium care. RESEARCH QUESTION: What are the perceptions of ICU leaders regarding the current challenges associated with delirium recognition and management and the potential benefits of continuous delirium monitoring? STUDY DESIGN AND METHODS: We conducted a blinded, cross-sectional, electronic survey of ICU leaders across the U.S., including physician directors and nursing managers with ≥3 years of ICU leadership experience. We asked about perceptions of the effectiveness of current delirium clinical assessment tools, current delirium detection and management challenges, and how an objective, continuous delirium monitoring system might impact clinician practice and patient outcomes in their ICU. RESULTS: Among the 81 respondents (62 physicians, 19 nurses), most (76%) reported that recommended delirium assessment tools (CAM-ICU, ICDSC) are used in their ICUs, though there were mixed perceptions on how reliably they are conducted. A majority (63-90%) perceived that current bedside assessments delay and limit the recognition of ICU delirium. Nearly all (89%) agreed an objective delirium monitoring tool would be more clinically valuable than current delirium assessment tools and that it would support real-time, delirium management by clinicians. CONCLUSIONS: ICU leaders perceive that there are limitations to using clinical delirium assessment tools in ICU patients to effectively detect and manage ICU delirium. Most felt that an objective delirium monitor could facilitate delirium detection and potentially expedite appropriate delirium management in patients.
- Open Access
- 2 September 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (5) , 1356-1372
Multi-electrode stimulation evokes consistent spatial patterns of phosphenes and improves phosphene mapping in blind subjects
- 2 September 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (5) , 1356-1372
Open AccessMulti-electrode stimulation evokes consistent spatial patterns of phosphenes and improves phosphene mapping in blind subjects
- Open Access
- 1 July 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (4) , 851-860
Eye movements and the perceived location of phosphenes generated by intracranial primary visual cortex stimulation in the blind
- 1 July 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (4) , 851-860
Open AccessEye movements and the perceived location of phosphenes generated by intracranial primary visual cortex stimulation in the blind
- Open Access
- 11 December 2020
- Published by Springer Nature in Communications Biology
- Vol. 3 (1) , 1-7
The human primary somatosensory cortex encodes imagined movement in the absence of sensory information
Classical systems neuroscience positions primary sensory areas as early feed-forward processing stations for refining incoming sensory information. This view may oversimplify their role given extensive bi-directional connectivity with multimodal cortical and subcortical regions. Here we show that single units in human primary somatosensory cortex encode imagined reaches in a cognitive motor task, but not other sensory–motor variables such as movement plans or imagined arm position. A population reference-frame analysis demonstrates coding relative to the cued starting hand location suggesting that imagined reaching movements are encoded relative to imagined limb position. These results imply a potential role for primary somatosensory cortex in cognitive imagery, engagement during motor production in the absence of sensation or expected sensation, and suggest that somatosensory cortex can provide control signals for future neural prosthetic systems.
- 11 December 2020
- Published by Springer Nature in Communications Biology
- Vol. 3 (1) , 1-7
Open AccessThe human primary somatosensory cortex encodes imagined movement in the absence of sensory information
Classical systems neuroscience positions primary sensory areas as early feed-forward processing stations for refining incoming sensory information. This view may oversimplify their role given extensive bi-directional connectivity with multimodal cortical and subcortical regions. Here we show that single units in human primary somatosensory cortex encode imagined reaches in a cognitive motor task, but not other sensory–motor variables such as movement plans or imagined arm position. A population reference-frame analysis demonstrates coding relative to the cued starting hand location suggesting that imagined reaching movements are encoded relative to imagined limb position. These results imply a potential role for primary somatosensory cortex in cognitive imagery, engagement during motor production in the absence of sensation or expected sensation, and suggest that somatosensory cortex can provide control signals for future neural prosthetic systems.
- Top Cited PapersOpen Access
- 10 April 2018
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 7
Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation
Pioneering work with nonhuman primates and recent human studies established intracortical microstimulation (ICMS) in primary somatosensory cortex (S1) as a method of inducing discriminable artificial sensation. However, these artificial sensations do not yet provide the breadth of cutaneous and proprioceptive percepts available through natural stimulation. In a tetraplegic human with two microelectrode arrays implanted in S1, we report replicable elicitations of sensations in both the cutaneous and proprioceptive modalities localized to the contralateral arm, dependent on both amplitude and frequency of stimulation. Furthermore, we found a subset of electrodes that exhibited multimodal properties, and that proprioceptive percepts on these electrodes were associated with higher amplitudes, irrespective of the frequency. These novel results demonstrate the ability to provide naturalistic percepts through ICMS that can more closely mimic the body’s natural physiological capabilities. Furthermore, delivering both cutaneous and proprioceptive sensations through artificial somatosensory feedback could improve performance and embodiment in brain-machine interfaces.
- 10 April 2018
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 7
Top Cited PapersOpen AccessProprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation
Pioneering work with nonhuman primates and recent human studies established intracortical microstimulation (ICMS) in primary somatosensory cortex (S1) as a method of inducing discriminable artificial sensation. However, these artificial sensations do not yet provide the breadth of cutaneous and proprioceptive percepts available through natural stimulation. In a tetraplegic human with two microelectrode arrays implanted in S1, we report replicable elicitations of sensations in both the cutaneous and proprioceptive modalities localized to the contralateral arm, dependent on both amplitude and frequency of stimulation. Furthermore, we found a subset of electrodes that exhibited multimodal properties, and that proprioceptive percepts on these electrodes were associated with higher amplitudes, irrespective of the frequency. These novel results demonstrate the ability to provide naturalistic percepts through ICMS that can more closely mimic the body’s natural physiological capabilities. Furthermore, delivering both cutaneous and proprioceptive sensations through artificial somatosensory feedback could improve performance and embodiment in brain-machine interfaces.