Enbo Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Enbo Yang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Shu Xiao
Old Dominion University
3 shared publications - Wei Du
University of Arkansas
3 shared publications Joe Margetis
Applied Materials, Arizona Research Center, Tempe, Arizona 85284, United States of America
2 shared publicationsShui-Qing Yu
University of Arkansas
2 shared publications- Shui-Qing Yu
Department of Electrical Engineering and Computer Science, University of Arkansas 2 , Fayetteville, Arkansas 72701
2 shared publications - Xuehuan Ma
University of Arkansas
2 shared publications
Latest Publications
- Open Access
- 4 November 2026
- Published by IOP Publishing in Nanotechnology
- Vol. 37 (44) , 445201
Quantitative determination of external and spontaneous quantum efficiencies in SiGeSn/GeSn quantum wells using Lambertian-referenced photoluminescence
GeSn quantum wells (QWs) are promising active regions for monolithically integrated group-IV mid-infrared light emitters, yet their radiative efficiency has not been quantitatively established because of the lack of a reproducible, system-independent measurement methodology. Here, we systematically determine the external quantum efficiency (EQE) and spontaneous emission quantum efficiency (SQE) of SiGeSn/GeSn single- and double-QW (SQW and DQW) structures using a Lambertian-referenced photoluminescence (PL) technique. By combining calibrated EQE measurements with a photon extraction and recycling model, the intrinsic SQE is quantitatively extracted, enabling direct comparison across different material systems and experimental platforms. Temperature- and excitation-dependent measurements (10–300 K, 5–200 mW) reveal peak EQE/SQE values of 14.7%/85.9% for the SQW and 19.8%/89.7% for the DQW at 10 K, representing a substantial improvement over a previously reported GeSn QW reference sample measured under identical calibration conditions. The consistently high efficiencies obtained from independently fabricated SQW and DQW structures confirm the reproducibility of the optimized epitaxial growth process and indicate significantly improved material quality.
- 4 November 2026
- Published by IOP Publishing in Nanotechnology
- Vol. 37 (44) , 445201
Open AccessQuantitative determination of external and spontaneous quantum efficiencies in SiGeSn/GeSn quantum wells using Lambertian-referenced photoluminescence
GeSn quantum wells (QWs) are promising active regions for monolithically integrated group-IV mid-infrared light emitters, yet their radiative efficiency has not been quantitatively established because of the lack of a reproducible, system-independent measurement methodology. Here, we systematically determine the external quantum efficiency (EQE) and spontaneous emission quantum efficiency (SQE) of SiGeSn/GeSn single- and double-QW (SQW and DQW) structures using a Lambertian-referenced photoluminescence (PL) technique. By combining calibrated EQE measurements with a photon extraction and recycling model, the intrinsic SQE is quantitatively extracted, enabling direct comparison across different material systems and experimental platforms. Temperature- and excitation-dependent measurements (10–300 K, 5–200 mW) reveal peak EQE/SQE values of 14.7%/85.9% for the SQW and 19.8%/89.7% for the DQW at 10 K, representing a substantial improvement over a previously reported GeSn QW reference sample measured under identical calibration conditions. The consistently high efficiencies obtained from independently fabricated SQW and DQW structures confirm the reproducibility of the optimized epitaxial growth process and indicate significantly improved material quality.
- 10 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (6)
Dual-barrier GeSn quantum-well lasers with operation up to 150 K
GeSn/SiGeSn quantum wells (QWs) have been investigated for the development of GeSn-based lasers. Barrier/well configurations including GeSn/GeSn and SiGeSn/GeSn were grown and characterized to evaluate carrier confinement and collection efficiency. In our previous work, a dual-barrier design (SiGeSn barrier/GeSn barrier/GeSn well) exhibited improved carrier collection efficiency for a GeSn single QW structure compared with a single-barrier configuration; however, no lasing had been reported from dual QW devices to date. Here, we report lasing from a GeSn dual-barrier single QW structure up to 140 K, with a threshold of 67 kW/cm2 at 77 K, representing a substantial threshold reduction. In addition, a 4-QW laser employing the same dual-barrier design demonstrates a clearly reduced threshold of 50 kW/cm2 at 77 K and a slightly increased maximum operating temperature of 150 K. The lower lasing threshold is attributed to decreased average carrier concentration in each well that improves the differential gain and the reduced Auger recombination rate.
- 10 August 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (6)
Dual-barrier GeSn quantum-well lasers with operation up to 150 K
GeSn/SiGeSn quantum wells (QWs) have been investigated for the development of GeSn-based lasers. Barrier/well configurations including GeSn/GeSn and SiGeSn/GeSn were grown and characterized to evaluate carrier confinement and collection efficiency. In our previous work, a dual-barrier design (SiGeSn barrier/GeSn barrier/GeSn well) exhibited improved carrier collection efficiency for a GeSn single QW structure compared with a single-barrier configuration; however, no lasing had been reported from dual QW devices to date. Here, we report lasing from a GeSn dual-barrier single QW structure up to 140 K, with a threshold of 67 kW/cm2 at 77 K, representing a substantial threshold reduction. In addition, a 4-QW laser employing the same dual-barrier design demonstrates a clearly reduced threshold of 50 kW/cm2 at 77 K and a slightly increased maximum operating temperature of 150 K. The lower lasing threshold is attributed to decreased average carrier concentration in each well that improves the differential gain and the reduced Auger recombination rate.
- 1 April 2025
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 14 (4) , 043010
Gas Phase Reactions Determined by In Situ Mass Spectrometric Investigation for GeSn Chemical Vapor Deposition Processes
GeSn alloy has gained significant attention for its compatibility with Si photonics platforms and its engineerable bandgap covering mid-infrared (MIR) wavelengths. Chemical vapor deposition (CVD) is widely used to synthesize GeSn materials. However, a fundamental understanding of the growth mechanism must still be developed. This research used mass spectrometry to investigate CVD gas phase reactions at various temperatures of 25 °C, 100 °C, 150 °C, and 200 °C for a gas mixture of GeH 4 and SnCl 4 with various gas partial pressure ratios (p SnCl4 /p GeH4) of 0.002, 0.005, 0.01 and 0.042. The analysis of the experimental results indicates two types of gas phase reactions occurred in all scenarios examined. The reactions involve direct interactions between SnCl 4 and GeH 4, as well as the decomposition of GeH 4. The hybrid radicals of Sn, H 3 SnCl/SnCl, the Germanium hybrid fragments of H 3 GeCl/GeCl, H 2 GeCl 2 /GeCl 2, and GeH x and hydrogens (H, H 2, and H 3 +) are the primary products of the first and second types of reactions, respectively. These reactions exhibit increased reactivity at higher temperatures, and the resulting intermediates are essential for the GeSn CVD process. Density functional theory-based thermochemical calculations agree with the experimental results and indicate that the proposed chemical reactions are either exothermic or minimally endothermic.
- 1 April 2025
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 14 (4) , 043010
Gas Phase Reactions Determined by In Situ Mass Spectrometric Investigation for GeSn Chemical Vapor Deposition Processes
GeSn alloy has gained significant attention for its compatibility with Si photonics platforms and its engineerable bandgap covering mid-infrared (MIR) wavelengths. Chemical vapor deposition (CVD) is widely used to synthesize GeSn materials. However, a fundamental understanding of the growth mechanism must still be developed. This research used mass spectrometry to investigate CVD gas phase reactions at various temperatures of 25 °C, 100 °C, 150 °C, and 200 °C for a gas mixture of GeH 4 and SnCl 4 with various gas partial pressure ratios (p SnCl4 /p GeH4) of 0.002, 0.005, 0.01 and 0.042. The analysis of the experimental results indicates two types of gas phase reactions occurred in all scenarios examined. The reactions involve direct interactions between SnCl 4 and GeH 4, as well as the decomposition of GeH 4. The hybrid radicals of Sn, H 3 SnCl/SnCl, the Germanium hybrid fragments of H 3 GeCl/GeCl, H 2 GeCl 2 /GeCl 2, and GeH x and hydrogens (H, H 2, and H 3 +) are the primary products of the first and second types of reactions, respectively. These reactions exhibit increased reactivity at higher temperatures, and the resulting intermediates are essential for the GeSn CVD process. Density functional theory-based thermochemical calculations agree with the experimental results and indicate that the proposed chemical reactions are either exothermic or minimally endothermic.
- 26 June 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (4)
In situ mass spectrometric investigation to probe GeSn growth dynamics and mechanisms in the chemical vapor deposition processes
GeSn has attracted increasing attention due to its tunable bandgap from indirect to direct resulting in unique electronic and optoelectronic capabilities. Chemical vapor deposition (CVD) is well acknowledged as an advanced growth method for GeSn, demonstrating its capability with grown materials for infrared lasers and detector development. As an in situ diagnostics of the CVD process, a residual gas analyzer (RGA) could enable the detection of all gaseous species during growth, thus probing the growth dynamics and mechanism. Therefore, it is highly desirable but is lacking in the (Si)GeSn research community. This work utilized an RGA equipped with a specialized differential vacuum pumping system to analyze the mass spectra of the GeSn CVD precursors of SnCl4, GeH4, and their combination. The spectra of SnCl4 collected from gas samples at a standard base pressure of 0.3 Torr display consistent fragments with central mass-to-charge ratios (m/z) of 78, 120, 155, 225, and 260, corresponding to Sn+, SnCl2+, SnCl+, SnCl2+, SnCl3+, and SnCl4+, respectively. These profiles closely resemble those observed in the National Institute of Standards and Technology and Wiley and Matsumoto et al. The simultaneous introduction of SnCl4 and GeH4 at a combined pressure of several tens of Torr yields spectra, indicating a chemical reaction that produces GeCl4 at room temperature in the vacuum chamber and tubing. Utilizing Gaussian16 and ORCA codes, the ab initio and density functional thermochemistry computations were employed to predict potential essential reactions and validate the experimental findings.
- 26 June 2024
- Published by American Vacuum Society in Journal of Vacuum Science & Technology B
- Vol. 42 (4)
In situ mass spectrometric investigation to probe GeSn growth dynamics and mechanisms in the chemical vapor deposition processes
GeSn has attracted increasing attention due to its tunable bandgap from indirect to direct resulting in unique electronic and optoelectronic capabilities. Chemical vapor deposition (CVD) is well acknowledged as an advanced growth method for GeSn, demonstrating its capability with grown materials for infrared lasers and detector development. As an in situ diagnostics of the CVD process, a residual gas analyzer (RGA) could enable the detection of all gaseous species during growth, thus probing the growth dynamics and mechanism. Therefore, it is highly desirable but is lacking in the (Si)GeSn research community. This work utilized an RGA equipped with a specialized differential vacuum pumping system to analyze the mass spectra of the GeSn CVD precursors of SnCl4, GeH4, and their combination. The spectra of SnCl4 collected from gas samples at a standard base pressure of 0.3 Torr display consistent fragments with central mass-to-charge ratios (m/z) of 78, 120, 155, 225, and 260, corresponding to Sn+, SnCl2+, SnCl+, SnCl2+, SnCl3+, and SnCl4+, respectively. These profiles closely resemble those observed in the National Institute of Standards and Technology and Wiley and Matsumoto et al. The simultaneous introduction of SnCl4 and GeH4 at a combined pressure of several tens of Torr yields spectra, indicating a chemical reaction that produces GeCl4 at room temperature in the vacuum chamber and tubing. Utilizing Gaussian16 and ORCA codes, the ab initio and density functional thermochemistry computations were employed to predict potential essential reactions and validate the experimental findings.
- 1 October 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 123, 77-87
Nanosecond bipolar pulse generators for bioelectrics
- 1 October 2018
- Published by Elsevier in Bioelectrochemistry
- Vol. 123, 77-87
Nanosecond bipolar pulse generators for bioelectrics
- Open Access
- 18 March 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-10
Cell Fragmentation and Permeabilization by a 1 ns Pulse Driven Triple-Point Electrode
Ultrashort electric pulses (ns-ps) are useful in gaining understanding as to how pulsed electric fields act upon biological cells, but the electric field intensity to induce biological responses is typically higher than longer pulses and therefore a high voltage ultrashort pulse generator is required. To deliver 1 ns pulses with sufficient electric field but at a relatively low voltage, we used a glass-encapsulated tungsten wire triple-point electrode (TPE) at the interface among glass, tungsten wire, and water when it is immersed in water. A high electric field (2 MV/cm) can be created when pulses are applied. However, such a high electric field was found to cause bubble emission and temperature rise in the water near the electrode. They can be attributed to Joule heating near the electrode. Adherent cells on a cover slip treated by the combination of these stimuli showed two major effects: (1) cells in a crater (μm from electrode) were fragmented and the debris was blown away. The principal mechanism for the damage is presumed to be shear forces due to bubble collapse; and (2) cells in the periphery of the crater were permeabilized, which was due to the combination of bubble movement and microstreaming as well as pulsed electric fields. These results show that ultrashort electric fields assisted by microbubbles can cause significant cell response and therefore a triple-point electrode is a useful ablation tool for applications that require submillimeter precision.
- 18 March 2018
- Published by Wiley in BioMed Research International
- Vol. 2018, 1-10
Open AccessCell Fragmentation and Permeabilization by a 1 ns Pulse Driven Triple-Point Electrode
Ultrashort electric pulses (ns-ps) are useful in gaining understanding as to how pulsed electric fields act upon biological cells, but the electric field intensity to induce biological responses is typically higher than longer pulses and therefore a high voltage ultrashort pulse generator is required. To deliver 1 ns pulses with sufficient electric field but at a relatively low voltage, we used a glass-encapsulated tungsten wire triple-point electrode (TPE) at the interface among glass, tungsten wire, and water when it is immersed in water. A high electric field (2 MV/cm) can be created when pulses are applied. However, such a high electric field was found to cause bubble emission and temperature rise in the water near the electrode. They can be attributed to Joule heating near the electrode. Adherent cells on a cover slip treated by the combination of these stimuli showed two major effects: (1) cells in a crater (μm from electrode) were fragmented and the debris was blown away. The principal mechanism for the damage is presumed to be shear forces due to bubble collapse; and (2) cells in the periphery of the crater were permeabilized, which was due to the combination of bubble movement and microstreaming as well as pulsed electric fields. These results show that ultrashort electric fields assisted by microbubbles can cause significant cell response and therefore a triple-point electrode is a useful ablation tool for applications that require submillimeter precision.
- 16 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (2) , 338-350
High-Voltage, Multiphasic, Nanosecond Pulses to Modulate Cellular Responses
Nanosecond electric pulses are an effective power source in plasma medicine and biological stimulation, in which biophysical responses are governed by peak power and not energy. While uniphasic nanosecond pulse generators are widely available, the recent discovery that biological effects can be uniquely modulated by reversing the polarity of nanosecond duration pulses calls for the development of a multimodal pulse generator. This paper describes a method to generate nanosecond multiphasic pulses for biomedical use, and specifically demonstrates its ability to cancel or enhance cell swelling and blebbing. The generator consists of a series of the fundamental module, which includes a capacitor and a MOSFET switch. A positive or a negative phase pulse module can be produced based on how the switch is connected. Stacking the modules in series can increase the voltage up to 5 kV. Multiple stacks in parallel can create multiphase outputs. As each stack is independently controlled and charged, multiphasic pulses can be created to produce flexible and versatile pulse waveforms. The circuit topology can be used for high-frequency uniphasic or biphasic nanosecond burst pulse production, creating numerous opportunities for the generator in electroporation applications, tissue ablation, wound healing, and nonthermal plasma generation.
- 16 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (2) , 338-350
High-Voltage, Multiphasic, Nanosecond Pulses to Modulate Cellular Responses
Nanosecond electric pulses are an effective power source in plasma medicine and biological stimulation, in which biophysical responses are governed by peak power and not energy. While uniphasic nanosecond pulse generators are widely available, the recent discovery that biological effects can be uniquely modulated by reversing the polarity of nanosecond duration pulses calls for the development of a multimodal pulse generator. This paper describes a method to generate nanosecond multiphasic pulses for biomedical use, and specifically demonstrates its ability to cancel or enhance cell swelling and blebbing. The generator consists of a series of the fundamental module, which includes a capacitor and a MOSFET switch. A positive or a negative phase pulse module can be produced based on how the switch is connected. Stacking the modules in series can increase the voltage up to 5 kV. Multiple stacks in parallel can create multiphase outputs. As each stack is independently controlled and charged, multiphasic pulses can be created to produce flexible and versatile pulse waveforms. The circuit topology can be used for high-frequency uniphasic or biphasic nanosecond burst pulse production, creating numerous opportunities for the generator in electroporation applications, tissue ablation, wound healing, and nonthermal plasma generation.