Michio Nagashima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michio Nagashima has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jun Hirokami
Department of Cardiology Kokura Memorial Hospital Kitakyushu Japan
1 shared publication - Junji Morita
Department of Cardiology Sapporo Cardiovascular Clinic Sapporo Hokkaido Japan
1 shared publication - Kengo Korai
Department of Cardiology, Kokura Memorial Hospital , 1-2-3 Asano, North of Kokura, Kitakyushu, Fukuoka 802-8555
1 shared publication Kenichi Hiroshima
Department of Cardiology, Kokura Memorial Hospital , 1-2-3 Asano, North of Kokura, Kitakyushu, Fukuoka 802-8555
1 shared publicationKenji Ando
Department of Cardiology, Kokura Memorial Hospital , 1-2-3 Asano, North of Kokura, Kitakyushu, Fukuoka 802-8555
1 shared publication- Kenji Ando
Kokura Memorial Hospital
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (10)
Unintended right atrial lesions after monopolar biphasic lattice-tip pulsed-field ablation: a case series
Background: Monopolar biphasic pulsed-field ablation (PFA) delivered by a lattice-tip catheter may create deeper lesions than conventional bipolar systems. The impact on adjacent right atrial structures remains poorly characterized. Case summary: We report four patients undergoing pulmonary vein isolation using a lattice-tip PFA catheter. Post-procedural electroanatomic mapping revealed unintended right atrial lesions involving the posterior right atrium, interatrial septum, or superior vena cava. In patients with short anatomical distances between right pulmonary veins and adjacent right atrial structures, lesions developed despite apparently successful pulmonary vein isolation. Catheter instability related to coughing under deep sedation appeared to contribute to broader lesion formation in two cases. Discussion: These cases suggest that monopolar biphasic lattice-tip PFA may create unintended lesions in adjacent right atrial tissue when anatomical proximity is short or catheter stability is compromised. Awareness of these mechanisms may help optimize procedural safety and lesion delivery.
- 30 September 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (10)
Open AccessUnintended right atrial lesions after monopolar biphasic lattice-tip pulsed-field ablation: a case series
Background: Monopolar biphasic pulsed-field ablation (PFA) delivered by a lattice-tip catheter may create deeper lesions than conventional bipolar systems. The impact on adjacent right atrial structures remains poorly characterized. Case summary: We report four patients undergoing pulmonary vein isolation using a lattice-tip PFA catheter. Post-procedural electroanatomic mapping revealed unintended right atrial lesions involving the posterior right atrium, interatrial septum, or superior vena cava. In patients with short anatomical distances between right pulmonary veins and adjacent right atrial structures, lesions developed despite apparently successful pulmonary vein isolation. Catheter instability related to coughing under deep sedation appeared to contribute to broader lesion formation in two cases. Discussion: These cases suggest that monopolar biphasic lattice-tip PFA may create unintended lesions in adjacent right atrial tissue when anatomical proximity is short or catheter stability is compromised. Awareness of these mechanisms may help optimize procedural safety and lesion delivery.
- Open Access
- 1 January 2018
- Published by XMLink in Korean Circulation Journal
- Vol. 48 (6) , 534-535
Leadless Pacemaker Implantation Following Transcatheter Aortic Valve Implantation Using SAPIEN 3
Shikama T, et al. Korean Circ J. 2016 Sep;48:e54. https://doi.org/10.4070/kcj.2018.0024
- 1 January 2018
- Published by XMLink in Korean Circulation Journal
- Vol. 48 (6) , 534-535
Open AccessLeadless Pacemaker Implantation Following Transcatheter Aortic Valve Implantation Using SAPIEN 3
Shikama T, et al. Korean Circ J. 2016 Sep;48:e54. https://doi.org/10.4070/kcj.2018.0024