Carmen Adduci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Carmen Adduci has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Pietro Francia
Division of Cardiology, Department of Clinical and Molecular Medicine, St. Andrea Hospital, Sapienza University , Rome
8 shared publications Francesca Palano
Division of Cardiology, Department of Clinical and Molecular Medicine, St. Andrea Hospital, Sapienza University of Rome, Via di Grottarossa, 1035, 00189, Rome, Italy
4 shared publications- Antonio Rapacciuolo
Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy
3 shared publications - Mauro Biffi
Institute of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna , Bologna, Italy
3 shared publications - Paolo De Filippo
ASST Papa Giovanni XXIII, Bergamo, Italy
3 shared publications - Stefano Viani
Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa , Pisa
3 shared publications
Latest Publications
- 1 March 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (3) , e013365
Subcutaneous Implantable Defibrillators in Young Patients: Arrhythmias, Complications, and Physical Activity
BACKGROUND: The safety of subcutaneous implantable cardioverter defibrillator (S-ICD) recipients who lead active lifestyles and engage in recreational sports is unknown. We aimed to evaluate the association between lifestyle and recreational sports and the occurrence of arrhythmia- and device-related complications, appropriate and inappropriate shocks in S-ICD recipients. METHODS: We assessed a cohort of young-adult (15–65 years) S-ICD patients, evaluated their physical activity with IPAQ (International Physical Activity Questionnaire), and assessed the association between lifestyle and recreational sports on S-ICD safety and shocks. RESULTS: We enrolled 602 S-ICD recipients (77% men; age, 46±14 years). According to the IPAQ, patients were categorized as inactive subjects (26.4%), moderately active subjects (45.2%), or highly active subjects (28.4%). Among moderately/highly active subjects, 163 (27.1%) were recreational athletes. During follow-up (47.3 [interquartile range, 27.0–67.6] months), 23 patients (3.8%) reached the safety end point of arrhythmia- or device-related complications, with moderately and highly active subjects showing in multivariate analysis similar incidence compared with inactive subjects ( P =0.59 and P =0.83, respectively). Forty-four patients had 87 appropriate shocks. In multivariate analysis, moderately and highly active subjects showed a nonsignificantly lower incidence of appropriate shocks compared with inactive subjects ( P =0.12 and P =0.11, respectively). Consistently, there was a nonsignificant lower incidence of appropriate shocks in athletes versus nonathletes ( P =0.06). Thirty-nine patients had 46 inappropriate shocks. Moderately and highly active subjects had similar incidence of inappropriate shocks compared with inactive subjects ( P =0.92 and P =0.88, respectively). CONCLUSIONS: Young S-ICD patients often lead active lifestyles and participate in sports. Higher activity levels were not associated with increased implantable cardioverter defibrillator–related complications or increased risk of implantable cardioverter defibrillator shocks.
- 1 March 2025
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 18 (3) , e013365
Subcutaneous Implantable Defibrillators in Young Patients: Arrhythmias, Complications, and Physical Activity
BACKGROUND: The safety of subcutaneous implantable cardioverter defibrillator (S-ICD) recipients who lead active lifestyles and engage in recreational sports is unknown. We aimed to evaluate the association between lifestyle and recreational sports and the occurrence of arrhythmia- and device-related complications, appropriate and inappropriate shocks in S-ICD recipients. METHODS: We assessed a cohort of young-adult (15–65 years) S-ICD patients, evaluated their physical activity with IPAQ (International Physical Activity Questionnaire), and assessed the association between lifestyle and recreational sports on S-ICD safety and shocks. RESULTS: We enrolled 602 S-ICD recipients (77% men; age, 46±14 years). According to the IPAQ, patients were categorized as inactive subjects (26.4%), moderately active subjects (45.2%), or highly active subjects (28.4%). Among moderately/highly active subjects, 163 (27.1%) were recreational athletes. During follow-up (47.3 [interquartile range, 27.0–67.6] months), 23 patients (3.8%) reached the safety end point of arrhythmia- or device-related complications, with moderately and highly active subjects showing in multivariate analysis similar incidence compared with inactive subjects ( P =0.59 and P =0.83, respectively). Forty-four patients had 87 appropriate shocks. In multivariate analysis, moderately and highly active subjects showed a nonsignificantly lower incidence of appropriate shocks compared with inactive subjects ( P =0.12 and P =0.11, respectively). Consistently, there was a nonsignificant lower incidence of appropriate shocks in athletes versus nonathletes ( P =0.06). Thirty-nine patients had 46 inappropriate shocks. Moderately and highly active subjects had similar incidence of inappropriate shocks compared with inactive subjects ( P =0.92 and P =0.88, respectively). CONCLUSIONS: Young S-ICD patients often lead active lifestyles and participate in sports. Higher activity levels were not associated with increased implantable cardioverter defibrillator–related complications or increased risk of implantable cardioverter defibrillator shocks.
- Open Access
- 2 August 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator
The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan–Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15–0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20–0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038–0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27–1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29–1.87; P = 0.521). Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
- 2 August 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (9)
Open AccessClinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator
The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan–Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15–0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20–0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038–0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27–1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29–1.87; P = 0.521). Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
- Open Access
- 27 April 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (6) , 995-1003
Home delivery of the communicator for remote monitoring of cardiac implantable devices: A multicenter experience during the covid‐19 lockdown
Background: During the COVID‐19 pandemic in‐person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home‐delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers.Methods: According to individual patient preference or the organizational decision of the center, patients were assigned to the home‐delivery group or the standard in‐clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months.Results: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th‐75th percentile: 10–20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID‐19 pandemic and possibly beyond.Conclusions: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high‐quality care.
- 27 April 2021
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 44 (6) , 995-1003
Open AccessHome delivery of the communicator for remote monitoring of cardiac implantable devices: A multicenter experience during the covid‐19 lockdown
Background: During the COVID‐19 pandemic in‐person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home‐delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers.Methods: According to individual patient preference or the organizational decision of the center, patients were assigned to the home‐delivery group or the standard in‐clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months.Results: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th‐75th percentile: 10–20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID‐19 pandemic and possibly beyond.Conclusions: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high‐quality care.
- 9 June 2020
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 27 (4) , 291-297
Prevention of Sudden Cardiac Death: Focus on the Subcutaneous Implantable Cardioverter-Defibrillator
The implantable cardioverter-defibrillator (ICD) is the most effective therapy to prevent sudden cardiac death (SCD) in high-risk patients. To overcome infections and failure of transvenous leads, the most frightening complications of conventional ICDs, a completely subcutaneous ICD (S-ICD) has been developed and is currently adopted in routine clinical practice. In view of their long life-expectancy, low competitive risk of dying from non-arrhythmic causes, and high lifetime risk of lead-related complications requiring surgical revisions, young patients with cardiomyopathies and inherited arrhythmia syndromes have traditionally been considered ideal candidates for the S-ICD. However, as growing evidence supported S-ICD safety and efficacy, initial niche implant indications were abandoned in favor of a widespread use of this technology, that is currently adopted in common ICD candidates with severe left ventricular dysfunction. Indeed, guidelines recommend S-ICD implantation as an alternative to TV-ICDs in all ICD candidates, unless pacing is required. This review focuses on the contemporary experience with the S-ICD and explores future scenarios in which device-to-device communication will enable to combine leadless therapies.
- 9 June 2020
- Published by Springer Nature in High Blood Pressure & Cardiovascular Prevention
- Vol. 27 (4) , 291-297
Prevention of Sudden Cardiac Death: Focus on the Subcutaneous Implantable Cardioverter-Defibrillator
The implantable cardioverter-defibrillator (ICD) is the most effective therapy to prevent sudden cardiac death (SCD) in high-risk patients. To overcome infections and failure of transvenous leads, the most frightening complications of conventional ICDs, a completely subcutaneous ICD (S-ICD) has been developed and is currently adopted in routine clinical practice. In view of their long life-expectancy, low competitive risk of dying from non-arrhythmic causes, and high lifetime risk of lead-related complications requiring surgical revisions, young patients with cardiomyopathies and inherited arrhythmia syndromes have traditionally been considered ideal candidates for the S-ICD. However, as growing evidence supported S-ICD safety and efficacy, initial niche implant indications were abandoned in favor of a widespread use of this technology, that is currently adopted in common ICD candidates with severe left ventricular dysfunction. Indeed, guidelines recommend S-ICD implantation as an alternative to TV-ICDs in all ICD candidates, unless pacing is required. This review focuses on the contemporary experience with the S-ICD and explores future scenarios in which device-to-device communication will enable to combine leadless therapies.
- 21 May 2020
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (8) , 2093-2098
Prognostic implications of nonsustained ventricular tachycardia morphology in high‐risk patients with hypertrophic cardiomyopathy
Introduction: The prognostic impact of nonsustained ventricular tachycardia (NSVT) morphology has never been explored in hypertrophic cardiomyopathy (HCM). In a single‐center cohort of consecutive HCM patients implanted with an implanted cardioverter‐defibrillator (ICD), we assessed NSVT morphology patterns and their prognostic implications.Methods: A cohort of consecutive HCM patients implanted with an ICD was followed from ICD implantation to last follow‐up visit. Patients were assessed for NSVT as stored events in ICD memory. Ventricular tachycardias (VTs) were classified as monomorphic (MM) or polymorphic according to intracardiac electrogram morphology.Results: One hundred nine consecutive HCM patients (68 males; mean age: 45 ± 17 years) composed the study population. During follow‐up (71 ± 48 months), 7 polymorphic NSVT in 4 patients and 370 MM NSVT in 42 patients were retrieved from ICD memory. Among patients with only MM NSVT, 19 (45%) had one morphology, 17 (41%) had two morphologies, 3 (7%) had three morphologies, and 3 (7%) had four morphologies. Patients with polymorphic NSVT had the highest risk of ICD interventions (HR, 5.04; 95% CI, 1.26‐20.19; P = .02). A stepwise increase of the risk of ICD interventions in patients with two, three, and four NSVT morphologies was observed. Out of 16 patients with both NSVT and ICD‐treated VTs, 13 (81%) had at least one ICD‐treated VT with the same morphology of a previous long‐lasting NSVT.Conclusions: In high‐risk HCM patients, the occurrence of polymorphic NSVT and of NSVT with multiple morphologies carries a high risk for ICD interventions. Sustained VTs tend to recur with the same morphology of previous long‐lasting NSVTs.
- 21 May 2020
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 31 (8) , 2093-2098
Prognostic implications of nonsustained ventricular tachycardia morphology in high‐risk patients with hypertrophic cardiomyopathy
Introduction: The prognostic impact of nonsustained ventricular tachycardia (NSVT) morphology has never been explored in hypertrophic cardiomyopathy (HCM). In a single‐center cohort of consecutive HCM patients implanted with an implanted cardioverter‐defibrillator (ICD), we assessed NSVT morphology patterns and their prognostic implications.Methods: A cohort of consecutive HCM patients implanted with an ICD was followed from ICD implantation to last follow‐up visit. Patients were assessed for NSVT as stored events in ICD memory. Ventricular tachycardias (VTs) were classified as monomorphic (MM) or polymorphic according to intracardiac electrogram morphology.Results: One hundred nine consecutive HCM patients (68 males; mean age: 45 ± 17 years) composed the study population. During follow‐up (71 ± 48 months), 7 polymorphic NSVT in 4 patients and 370 MM NSVT in 42 patients were retrieved from ICD memory. Among patients with only MM NSVT, 19 (45%) had one morphology, 17 (41%) had two morphologies, 3 (7%) had three morphologies, and 3 (7%) had four morphologies. Patients with polymorphic NSVT had the highest risk of ICD interventions (HR, 5.04; 95% CI, 1.26‐20.19; P = .02). A stepwise increase of the risk of ICD interventions in patients with two, three, and four NSVT morphologies was observed. Out of 16 patients with both NSVT and ICD‐treated VTs, 13 (81%) had at least one ICD‐treated VT with the same morphology of a previous long‐lasting NSVT.Conclusions: In high‐risk HCM patients, the occurrence of polymorphic NSVT and of NSVT with multiple morphologies carries a high risk for ICD interventions. Sustained VTs tend to recur with the same morphology of previous long‐lasting NSVTs.
- 4 June 2019
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 30 (8) , 1373-1374
Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator
- 4 June 2019
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 30 (8) , 1373-1374
Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator
- Open Access
- 11 March 2018
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 7 (3) , 53
Safety, Efficacy and Evidence Base for Use of the Subcutaneous Implantable Cardioverter Defibrillator
The trans-venous implantable cardioverter defibrillator (TV-ICD) is effective in treating life-threatening ventricular arrhythmia and reduces mortality in high-risk patients. However, there are significant short- and long-term complications that are associated with intravascular leads. These shortcomings are mostly relevant in young patients with long life expectancy and low risk of death from non-arrhythmic causes. Drawbacks of trans-venous leads recently led to the development of the entirely subcutaneous implantable cardioverter defibrillator (S-ICD). The S-ICD does not require vascular access or permanent intravascular defibrillation leads. Therefore, it is expected to overcome many complications associated with conventional ICDs. This review highlights data on safety and efficacy of the S-ICD and is envisioned to help in identifying the role of this device in clinical practice.
- 11 March 2018
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 7 (3) , 53
Open AccessSafety, Efficacy and Evidence Base for Use of the Subcutaneous Implantable Cardioverter Defibrillator
The trans-venous implantable cardioverter defibrillator (TV-ICD) is effective in treating life-threatening ventricular arrhythmia and reduces mortality in high-risk patients. However, there are significant short- and long-term complications that are associated with intravascular leads. These shortcomings are mostly relevant in young patients with long life expectancy and low risk of death from non-arrhythmic causes. Drawbacks of trans-venous leads recently led to the development of the entirely subcutaneous implantable cardioverter defibrillator (S-ICD). The S-ICD does not require vascular access or permanent intravascular defibrillation leads. Therefore, it is expected to overcome many complications associated with conventional ICDs. This review highlights data on safety and efficacy of the S-ICD and is envisioned to help in identifying the role of this device in clinical practice.
- Open Access
- 1 August 2017
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 38 (suppl_1)
P6389S-ICD eligibility according to a novel automated screening tool and agreement with the standard manual ECG morphology tool: a preliminary multicenter experience
Background/Introduction: The subcutaneous implantable cardioverter defibrillator (S-ICD) is an effective alternative to the transvenous ICD for the treatment of life-threatening ventricular arrhythmias. Since S-ICD introduction, the pre-implant screening based on a dedicated manual ECG morphology tool (MST) was required to assure adequate sensing by the S-ICD. A novel automated screening tool (AST) has been recently developed.
- 1 August 2017
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 38 (suppl_1)
Open AccessP6389S-ICD eligibility according to a novel automated screening tool and agreement with the standard manual ECG morphology tool: a preliminary multicenter experience
Background/Introduction: The subcutaneous implantable cardioverter defibrillator (S-ICD) is an effective alternative to the transvenous ICD for the treatment of life-threatening ventricular arrhythmias. Since S-ICD introduction, the pre-implant screening based on a dedicated manual ECG morphology tool (MST) was required to assure adequate sensing by the S-ICD. A novel automated screening tool (AST) has been recently developed.