Byongjo Yun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Byongjo Yun has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jae Jun Jeong
Pusan National University
7 shared publications Jae Jun Jeong
School of Mechanical Engineering, Pusan National University, Busan 46241, Republic of Korea
5 shared publications- Jinyeong Bak
Pusan Natl Univ, Sch Mech Engn, 63 beon Gil 2,Busandaehak Ro, Pusan 46241, South Korea
4 shared publications Taehwan Ahn
Swiss Fed Inst Technol, Dept Mech & Proc Engn, Sonneggstr 3, CH-8092 Zurich, Switzerland
3 shared publicationsYoungchang Ko
Pusan Natl Univ, Sch Mech Engn, 63 beon Gil 2,Busandaehak Ro, Pusan 46241, South Korea
3 shared publicationsByeonggeon Bae
Pusan Natl Univ, Dept Mech Engn, 2 Busandaehak Ro,63 Beon Gil, Busan 46241, South Korea
2 shared publications
Latest Publications
- 29 November 2024
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 160
Mechanistic model of wall heat transfer for vertical subcooled boiling flow
- 29 November 2024
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 160
Mechanistic model of wall heat transfer for vertical subcooled boiling flow
- Open Access
- 12 November 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 64
Local two-group bubble size model for adiabatic air–water flow in a large diameter pipe using CFD code
- 12 November 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 64
Open AccessLocal two-group bubble size model for adiabatic air–water flow in a large diameter pipe using CFD code
- Open Access
- 16 March 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (8) , 3139-3143
An explicit approximation of the central angle for the curved interface in double-circle model for horizontal two-phase stratified flow
- 16 March 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 56 (8) , 3139-3143
Open AccessAn explicit approximation of the central angle for the curved interface in double-circle model for horizontal two-phase stratified flow
- 10 April 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 192, 122889
Experimental investigation of droplet parameters in a 2×2 rod bundle under air-water annular-mist flow
- 10 April 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 192, 122889
Experimental investigation of droplet parameters in a 2×2 rod bundle under air-water annular-mist flow
- Open Access
- 6 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (16) , 5443
Development of Bubble Size Correlation for Adiabatic Forced Convective Bubbly Flow in Low Pressure Condition Using CFD Code
In a multidimensional two-phase flow analysis, bubble size significantly affects interfacial transfer terms such as mass, momentum, and energy. With regard to bubbly flow, the application of a simple correlation-type bubble size model presents certain advantages, including short calculation times and ease of usage. In this study, we propose a semi-theoretical correlation developed from a steady state bubble number density transport equation for predicting the distribution of local bubble size using a computational fluid dynamics (CFD) code. The coefficients of the new correlation were determined using the local bubble parameters obtained on the basis of three existing vertical air-water experiments. Finally, these were implemented in commercial CFD code and evaluated against experimental data, which showed that the proposed correlation exhibits good prediction capability for forced convective air-water bubbly flows under low pressure conditions.
- 6 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (16) , 5443
Open AccessDevelopment of Bubble Size Correlation for Adiabatic Forced Convective Bubbly Flow in Low Pressure Condition Using CFD Code
In a multidimensional two-phase flow analysis, bubble size significantly affects interfacial transfer terms such as mass, momentum, and energy. With regard to bubbly flow, the application of a simple correlation-type bubble size model presents certain advantages, including short calculation times and ease of usage. In this study, we propose a semi-theoretical correlation developed from a steady state bubble number density transport equation for predicting the distribution of local bubble size using a computational fluid dynamics (CFD) code. The coefficients of the new correlation were determined using the local bubble parameters obtained on the basis of three existing vertical air-water experiments. Finally, these were implemented in commercial CFD code and evaluated against experimental data, which showed that the proposed correlation exhibits good prediction capability for forced convective air-water bubbly flows under low pressure conditions.
- Open Access
- 30 June 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (13) , 4559
CFD Analysis of Subcooled Flow Boiling in 4 × 4 Rod Bundle
Rod bundle flow is an important research field related to reactor cooling in nuclear power plants. Owing to the rapid development of computerized performance assessments, interest in coolant flow analysis using computational fluid dynamics has garnered research interest. Rod bundle flow research data compared with experimental results under various conditions are thus needed. To address this, a boiling model verification study was conducted with reference to experiments. This study adopts the Reynolds-averaged Navier–Stokes equation, a practical analysis method compared to direct numerical simulation and large eddy simulation, including turbulence modeling, to predict the flow of coolant inside a rod bundle. This study also investigates void behavior in low-pressure subcooled flow boiling using a Eulerian approach (two-fluid model). The rod bundle has a length of 0.59 m and a hydraulic diameter of approximately 14.01 mm. At the cross-section at a height of 0.58 m, near the exit, numerical results were compared with the experimental values of the volume fraction of vapor and interfacial area concentration. The simulation results showed good agreement with the experimental data for six different initial conditions with constant density.
- 30 June 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (13) , 4559
Open AccessCFD Analysis of Subcooled Flow Boiling in 4 × 4 Rod Bundle
Rod bundle flow is an important research field related to reactor cooling in nuclear power plants. Owing to the rapid development of computerized performance assessments, interest in coolant flow analysis using computational fluid dynamics has garnered research interest. Rod bundle flow research data compared with experimental results under various conditions are thus needed. To address this, a boiling model verification study was conducted with reference to experiments. This study adopts the Reynolds-averaged Navier–Stokes equation, a practical analysis method compared to direct numerical simulation and large eddy simulation, including turbulence modeling, to predict the flow of coolant inside a rod bundle. This study also investigates void behavior in low-pressure subcooled flow boiling using a Eulerian approach (two-fluid model). The rod bundle has a length of 0.59 m and a hydraulic diameter of approximately 14.01 mm. At the cross-section at a height of 0.58 m, near the exit, numerical results were compared with the experimental values of the volume fraction of vapor and interfacial area concentration. The simulation results showed good agreement with the experimental data for six different initial conditions with constant density.
- 1 October 2019
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 141, 71-87
Steam condensation in horizontal and inclined tubes under stratified flow conditions
- 1 October 2019
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 141, 71-87
Steam condensation in horizontal and inclined tubes under stratified flow conditions
- 25 April 2019
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 141 (4)
Numerical Analysis of Subcooled Water Flashing Flow From a Pressurized Water Reactor Steam Generator Through an Abruptly Broken Main Feed Water Pipe
A computational fluid dynamics (CFD) analysis was performed to investigate the hydraulic response of the flow field inside the pressurized water reactor (PWR) steam generator (SG) secondary side and the connected part of main feed water pipe to an abrupt main feed water line break (FWLB) accident. To realistically analyze the transient flow field situation, the flow field was assumed to be occupied initially by highly compressed subcooled water except that the upper part of the SG secondary side where steam occupied as in the practical case and the break was assumed to occur at the circumferential weld line between the feed water nozzle and the main feed water pipe. This would result in a subcooled water flashing flow from the SG through the short-broken pipe end to the surrounding atmosphere, which was numerically simulated in this study. Typical results of the prediction in terms of the fluid transient velocity and pressure were illustrated and discussed. To examine the physical validity of the present numerical simulation of the subcooled water flashing flow, the transient mass flow rates predicted in this study were compared with the other previous numerical predictions based on the subcooled water nonflashing (no phase change) flow or saturated water flashing flow assumptions and the prediction by a simple analysis method.
- 25 April 2019
- Published by ASME International in Journal of Pressure Vessel Technology
- Vol. 141 (4)
Numerical Analysis of Subcooled Water Flashing Flow From a Pressurized Water Reactor Steam Generator Through an Abruptly Broken Main Feed Water Pipe
A computational fluid dynamics (CFD) analysis was performed to investigate the hydraulic response of the flow field inside the pressurized water reactor (PWR) steam generator (SG) secondary side and the connected part of main feed water pipe to an abrupt main feed water line break (FWLB) accident. To realistically analyze the transient flow field situation, the flow field was assumed to be occupied initially by highly compressed subcooled water except that the upper part of the SG secondary side where steam occupied as in the practical case and the break was assumed to occur at the circumferential weld line between the feed water nozzle and the main feed water pipe. This would result in a subcooled water flashing flow from the SG through the short-broken pipe end to the surrounding atmosphere, which was numerically simulated in this study. Typical results of the prediction in terms of the fluid transient velocity and pressure were illustrated and discussed. To examine the physical validity of the present numerical simulation of the subcooled water flashing flow, the transient mass flow rates predicted in this study were compared with the other previous numerical predictions based on the subcooled water nonflashing (no phase change) flow or saturated water flashing flow assumptions and the prediction by a simple analysis method.
- 4 March 2019
- Published by Wiley in AIChE Journal
- Vol. 65 (6)
Measuring local droplet parameters using single optical fiber probe
This article proposes a new single optical fiber probe (OFP) sensor method for measuring local droplet parameters such as droplet fraction, droplet velocity, and droplet diameter. To this end, we developed a stretched conical optical fiber probe (SC‐OFP) sensor that minimizes the wetting of the sensing tip at a high droplet velocity, a discrimination algorithm based on the first and second derivatives of the output of the raw signal of the OFP sensor, and a method that uses neural network training to determine local droplet velocity independently of droplet size. In the experiments conducted, the developed SC‐OFP sensor measured local droplet velocity with a mean absolute percentage error (MAPE) smaller than 4.1% for velocities ranging from 2 to 32 m/s, and droplet diameter with a MAPE smaller than 4.9% for diameters ranging from 0.29 to 1.78 mm.
- 4 March 2019
- Published by Wiley in AIChE Journal
- Vol. 65 (6)
Measuring local droplet parameters using single optical fiber probe
This article proposes a new single optical fiber probe (OFP) sensor method for measuring local droplet parameters such as droplet fraction, droplet velocity, and droplet diameter. To this end, we developed a stretched conical optical fiber probe (SC‐OFP) sensor that minimizes the wetting of the sensing tip at a high droplet velocity, a discrimination algorithm based on the first and second derivatives of the output of the raw signal of the OFP sensor, and a method that uses neural network training to determine local droplet velocity independently of droplet size. In the experiments conducted, the developed SC‐OFP sensor measured local droplet velocity with a mean absolute percentage error (MAPE) smaller than 4.1% for velocities ranging from 2 to 32 m/s, and droplet diameter with a MAPE smaller than 4.9% for diameters ranging from 0.29 to 1.78 mm.