Takanori Miura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takanori Miura has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Kijima
Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan
9 shared publications - Naohisa Miyakoshi
Department of Orthopaedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan
7 shared publications Naohisa Miyakoshi
Akita Hip Res Grp, Akita, Japan
6 shared publicationsYoichi Shimada
AORA (Akita Orthopedic Group on Rheumatoid Arthritis), Akita, Japan
6 shared publicationsHiroshi Tazawa
Akita Hip Res Grp, Akita, Japan
5 shared publications- Norio Yamamoto
Scientific Research Works Peer Support Group (SRWS-PSG), Osaka, Japan
5 shared publications
Latest Publications
- Open Access
- 11 February 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 7 (2) , 203-215
Acetabular component placement accuracy and short-term outcomes in total hip arthroplasty
Aims: Precise acetabular component positioning is critical to the success of total hip arthroplasty (THA). Mako uses CT-based robotic assistance, whereas AR-hip is an augmented reality-based portable navigation system operating without preoperative CT and at lower costs. Although both systems improve accuracy, direct comparative data are scarce. We compared cup placement accuracy and short-term outcomes between Mako robotic arm and AR navigation systems. Methods: This single-centre retrospective cohort study included 192 primary THAs (Mako, 147; AR navigation, 45). Cup placement accuracy was assessed three-dimensionally using postoperative CT, evaluating cup alignment (radiological inclination (RI) and anteversion (RA)) and position (centre of rotation (COR)). Short-term outcomes were evaluated using the Harris Hip Score (HHS), Japanese Orthopaedic Association hip score (JOA), Japanese Hip-disease Evaluation Questionnaire (JHEQ), Timed Up and Go (TUG), and 10 m walk test (10MWT). Baseline differences were adjusted using propensity score overlap weighting. Results: Mako demonstrated significantly superior accuracy than AR navigation, with smaller absolute errors in cup angles (RI 2.0° vs 3.0°, p = 0.045; RA 1.7° vs 2.4°, p = 0.005) and COR errors in the superior–inferior direction (1.5 mm vs 3.7 mm, p < 0.001). More cases were within 5° of planned angles with Mako (92.3% vs 77.7%, p = 0.030), while Lewinnek safe zone rates were high in both groups (99.5% vs 95.2%, p = 0.202). Short-term clinical scores and functional recovery at discharge were similar between groups. Operating time and blood loss were greater with Mako (122.6 vs 103.5 mins; 242.5 vs 171.5 ml; both p < 0.001). Subgroup analyses showed greater advantages of Mako in complex cases, such as obesity and developmental dysplasia of the hip, although interactions were insignificant. Conclusion: Mako demonstrated superior cup placement accuracy and COR reconstruction compared with AR navigation, with comparable short-term clinical outcomes, potentially offering advantages in complex cases. However, further research is warranted to clarify its long-term outcomes and cost-effectiveness. Cite this article: Bone Jt Open 2026;7(2):203–215.
- 11 February 2026
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 7 (2) , 203-215
Open AccessAcetabular component placement accuracy and short-term outcomes in total hip arthroplasty
Aims: Precise acetabular component positioning is critical to the success of total hip arthroplasty (THA). Mako uses CT-based robotic assistance, whereas AR-hip is an augmented reality-based portable navigation system operating without preoperative CT and at lower costs. Although both systems improve accuracy, direct comparative data are scarce. We compared cup placement accuracy and short-term outcomes between Mako robotic arm and AR navigation systems. Methods: This single-centre retrospective cohort study included 192 primary THAs (Mako, 147; AR navigation, 45). Cup placement accuracy was assessed three-dimensionally using postoperative CT, evaluating cup alignment (radiological inclination (RI) and anteversion (RA)) and position (centre of rotation (COR)). Short-term outcomes were evaluated using the Harris Hip Score (HHS), Japanese Orthopaedic Association hip score (JOA), Japanese Hip-disease Evaluation Questionnaire (JHEQ), Timed Up and Go (TUG), and 10 m walk test (10MWT). Baseline differences were adjusted using propensity score overlap weighting. Results: Mako demonstrated significantly superior accuracy than AR navigation, with smaller absolute errors in cup angles (RI 2.0° vs 3.0°, p = 0.045; RA 1.7° vs 2.4°, p = 0.005) and COR errors in the superior–inferior direction (1.5 mm vs 3.7 mm, p < 0.001). More cases were within 5° of planned angles with Mako (92.3% vs 77.7%, p = 0.030), while Lewinnek safe zone rates were high in both groups (99.5% vs 95.2%, p = 0.202). Short-term clinical scores and functional recovery at discharge were similar between groups. Operating time and blood loss were greater with Mako (122.6 vs 103.5 mins; 242.5 vs 171.5 ml; both p < 0.001). Subgroup analyses showed greater advantages of Mako in complex cases, such as obesity and developmental dysplasia of the hip, although interactions were insignificant. Conclusion: Mako demonstrated superior cup placement accuracy and COR reconstruction compared with AR navigation, with comparable short-term clinical outcomes, potentially offering advantages in complex cases. However, further research is warranted to clarify its long-term outcomes and cost-effectiveness. Cite this article: Bone Jt Open 2026;7(2):203–215.
- 1 November 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (11)
Comparison of Implant Placement Accuracy Between Manual, Robot-Assisted, Computer-Navigated, Augmented Reality Navigated, Patient-Specific Instrumentation, and Accelerometer Navigated Total Hip Arthroplasty
Background: Malpositioning of the acetabular cup during total hip arthroplasty (THA) can lead to complications. Robotic surgery and navigation techniques aim to address this issue, but there is limited evidence regarding which method can achieve better clinical outcomes. Therefore, this network meta-analysis (NMA) aimed to compare the efficacy of various navigation methods. Methods: This NMA of prospective randomized controlled trials compared robot-assisted systems (RAS), computer-assisted navigation systems (CAS), augmented reality-based portable navigation (AR), patient-specific instrumentation (PSI), portable accelerometer-based navigation (PN), and conventional methods (C) for THA procedures. We searched MEDLINE, EMBASE, Cochrane, Central Register of Controlled Trials, International Clinical Trials Platform Search Portal, and ClinicalTrials.gov. databases. The primary outcomes included revision surgery and postoperative clinical scores, and the secondary outcomes encompassed cup placement accuracy, acetabular cup placement outliers from the Lewinnek safe zone, surgical time, and complications. We used a Bayesian random-effects NMA, and confidence of evidence was assessed using confidence in NMA. Results: We identified 45 studies including 2,122 patients. We did not find large differences in revision surgery, clinical outcome scores, cup inclination, or anteversion angle accuracy among the modalities. AR, CAS, and PSI exhibited a lower risk of outliers from safe zones than C. In addition, RAS and CAS had a longer surgical time than C. Conclusions: Robotic and navigation tools did not reduce the revision risk or enhance clinical outcomes. AR, CAS, PSI, and PN may decrease the risk of cup placement outliers in safe zones. However, the cup placement accuracy was equivalent, and the surgical time may be longer in RAS and CAS than in C. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 1 November 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (11)
Comparison of Implant Placement Accuracy Between Manual, Robot-Assisted, Computer-Navigated, Augmented Reality Navigated, Patient-Specific Instrumentation, and Accelerometer Navigated Total Hip Arthroplasty
Background: Malpositioning of the acetabular cup during total hip arthroplasty (THA) can lead to complications. Robotic surgery and navigation techniques aim to address this issue, but there is limited evidence regarding which method can achieve better clinical outcomes. Therefore, this network meta-analysis (NMA) aimed to compare the efficacy of various navigation methods. Methods: This NMA of prospective randomized controlled trials compared robot-assisted systems (RAS), computer-assisted navigation systems (CAS), augmented reality-based portable navigation (AR), patient-specific instrumentation (PSI), portable accelerometer-based navigation (PN), and conventional methods (C) for THA procedures. We searched MEDLINE, EMBASE, Cochrane, Central Register of Controlled Trials, International Clinical Trials Platform Search Portal, and ClinicalTrials.gov. databases. The primary outcomes included revision surgery and postoperative clinical scores, and the secondary outcomes encompassed cup placement accuracy, acetabular cup placement outliers from the Lewinnek safe zone, surgical time, and complications. We used a Bayesian random-effects NMA, and confidence of evidence was assessed using confidence in NMA. Results: We identified 45 studies including 2,122 patients. We did not find large differences in revision surgery, clinical outcome scores, cup inclination, or anteversion angle accuracy among the modalities. AR, CAS, and PSI exhibited a lower risk of outliers from safe zones than C. In addition, RAS and CAS had a longer surgical time than C. Conclusions: Robotic and navigation tools did not reduce the revision risk or enhance clinical outcomes. AR, CAS, PSI, and PN may decrease the risk of cup placement outliers in safe zones. However, the cup placement accuracy was equivalent, and the surgical time may be longer in RAS and CAS than in C. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 10 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7031
Epidemiology and Reporting Characteristics of Systematic Reviews in Orthopedic Journals: A Meta-Epidemiological Study
Systematic reviews (SRs) with complete reporting or rigorous methods can lead to less biased recommendations and decisions. A comprehensive analysis of the epidemiological and reporting characteristics of SRs in orthopedics is lacking. We evaluated 360 SRs, including 165 and 195 published in orthopedic journals in 2012 and 2022. According to the established reporting guidelines, we examined these SRs for key epidemiological characteristics, including focus areas, type of meta-analysis (MA), and reporting characteristics. Most SRs (71%) were therapy-related, with a significant proportion originating from authors in the USA, UK, and China. Pairwise MA was performed on half of the SRs. The proportion of protocol registrations improved by 2022 but remained low (33%). Despite a formal declaration of adherence to the reporting guidelines (68%), they were often not used and reported enough. Only 10% of the studies used full search strategies, including trial registries. Publication bias assessments, subgroup analyses, and sensitivity analyses were not even planned. The risk of bias assessment improved in 2022; however, the certainty of the evidence remained largely unassessed (8%). The use and reporting of standard methods in orthopedic SRs have remained suboptimal. Thus, authors, peer reviewers, journal editors, and readers should criticize the results more.
- 10 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7031
Open AccessEpidemiology and Reporting Characteristics of Systematic Reviews in Orthopedic Journals: A Meta-Epidemiological Study
Systematic reviews (SRs) with complete reporting or rigorous methods can lead to less biased recommendations and decisions. A comprehensive analysis of the epidemiological and reporting characteristics of SRs in orthopedics is lacking. We evaluated 360 SRs, including 165 and 195 published in orthopedic journals in 2012 and 2022. According to the established reporting guidelines, we examined these SRs for key epidemiological characteristics, including focus areas, type of meta-analysis (MA), and reporting characteristics. Most SRs (71%) were therapy-related, with a significant proportion originating from authors in the USA, UK, and China. Pairwise MA was performed on half of the SRs. The proportion of protocol registrations improved by 2022 but remained low (33%). Despite a formal declaration of adherence to the reporting guidelines (68%), they were often not used and reported enough. Only 10% of the studies used full search strategies, including trial registries. Publication bias assessments, subgroup analyses, and sensitivity analyses were not even planned. The risk of bias assessment improved in 2022; however, the certainty of the evidence remained largely unassessed (8%). The use and reporting of standard methods in orthopedic SRs have remained suboptimal. Thus, authors, peer reviewers, journal editors, and readers should criticize the results more.
- Open Access
- 10 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7024
Characteristics and Treatment Strategies for Basicervical and Transcervical Shear Fractures of the Femoral Neck
This study aimed to define basicervical and transcervical shear fractures using area classification and to determine the optimal osteosynthesis implants for them. The clinical outcomes of 1042 proximal femur fractures were investigated. A model of the proximal femur of a healthy adult was created from computed tomography images, and basicervical and transcervical shear fractures were established in the model. Osteosynthesis models were created using a short femoral nail with a single lag screw or two lag screws and a long femoral nail with a single lag screw or two lag screws. The minimum principal strains of the fracture surfaces were compared when the maximum loads during walking were applied to these models using finite element analysis software. Basicervical fractures accounted for 0.96% of all proximal femur fractures, 67% of which were treated with osteosynthesis; the failure rate was 0%. Transcervical shear fractures accounted for 9.6% of all proximal femur fractures, 24% of which were treated with osteosynthesis; the failure rate was 13%. Finite element analysis showed that transcervical shear fracture has high instability. To perform osteosynthesis, multiple screw insertions into the femoral head and careful postoperative management are required; joint replacement should be considered to achieve early mobility.
- 10 November 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (22) , 7024
Open AccessCharacteristics and Treatment Strategies for Basicervical and Transcervical Shear Fractures of the Femoral Neck
This study aimed to define basicervical and transcervical shear fractures using area classification and to determine the optimal osteosynthesis implants for them. The clinical outcomes of 1042 proximal femur fractures were investigated. A model of the proximal femur of a healthy adult was created from computed tomography images, and basicervical and transcervical shear fractures were established in the model. Osteosynthesis models were created using a short femoral nail with a single lag screw or two lag screws and a long femoral nail with a single lag screw or two lag screws. The minimum principal strains of the fracture surfaces were compared when the maximum loads during walking were applied to these models using finite element analysis software. Basicervical fractures accounted for 0.96% of all proximal femur fractures, 67% of which were treated with osteosynthesis; the failure rate was 0%. Transcervical shear fractures accounted for 9.6% of all proximal femur fractures, 24% of which were treated with osteosynthesis; the failure rate was 13%. Finite element analysis showed that transcervical shear fracture has high instability. To perform osteosynthesis, multiple screw insertions into the femoral head and careful postoperative management are required; joint replacement should be considered to achieve early mobility.
- 6 October 2023
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 132 (5) , 1097-1111
Comparative efficacy of ultrasound guidance or conventional anatomical landmarks for neuraxial puncture in adult patients: a systematic review and network meta-analysis
- 6 October 2023
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 132 (5) , 1097-1111
Comparative efficacy of ultrasound guidance or conventional anatomical landmarks for neuraxial puncture in adult patients: a systematic review and network meta-analysis
- Open Access
- 13 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5268
Evaluation of Medial Meniscal Extrusion Using Radiography
Recently, there has been increasing interest in medial meniscal extrusion (MME), but few reports have evaluated MME via X-ray. In this study, the amount of MME and meniscal height at the medial border of the tibia were measured via X-ray with gradation processing. The extrusion length divided by the meniscal height yields the meniscal extrusion ratio, which was used as an index. In addition, the medial meniscal length of the part protruding from the medial border of the tibia on MRI was measured as an absolute value. Then, the correlation between the meniscal extrusion ratio and the amount of MME on MRI was examined, and there was a strong correlation between the meniscal extrusion ratio via X-ray and the amount of MME on MRI (correlation coefficient 0.860, p < 0.0001). The cut-off value of the meniscal extrusion ratio via X-ray for positive meniscal extrusion on MRI was 0.50, with an AUC of 0.9825, sensitivity of 0.9063, and specificity of 0.8663. From the present study, it was possible to measure the extrusion length and meniscal height via gradation processing, with X-ray and without MRI, and to calculate the meniscal extrusion ratio, which strongly correlates with the amount of MME on MRI.
- 13 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5268
Open AccessEvaluation of Medial Meniscal Extrusion Using Radiography
Recently, there has been increasing interest in medial meniscal extrusion (MME), but few reports have evaluated MME via X-ray. In this study, the amount of MME and meniscal height at the medial border of the tibia were measured via X-ray with gradation processing. The extrusion length divided by the meniscal height yields the meniscal extrusion ratio, which was used as an index. In addition, the medial meniscal length of the part protruding from the medial border of the tibia on MRI was measured as an absolute value. Then, the correlation between the meniscal extrusion ratio and the amount of MME on MRI was examined, and there was a strong correlation between the meniscal extrusion ratio via X-ray and the amount of MME on MRI (correlation coefficient 0.860, p < 0.0001). The cut-off value of the meniscal extrusion ratio via X-ray for positive meniscal extrusion on MRI was 0.50, with an AUC of 0.9825, sensitivity of 0.9063, and specificity of 0.8663. From the present study, it was possible to measure the extrusion length and meniscal height via gradation processing, with X-ray and without MRI, and to calculate the meniscal extrusion ratio, which strongly correlates with the amount of MME on MRI.
- 1 June 2023
- Vol. 77 (3) , 311-318
Current Femoral Stem Fixation Selection in Hip-Fracture Bipolar Hemiarthroplasties, and Factors Affecting Surgeons' Confidence in Their Ability to Teach about Cemented Stems: A Questionnaire in a Region of Japan with Super-Aged Patients
Japan's hip fracture management guidelines now recommend the use of cemented stems in cases of bone fragility. However, the current stem selection practices in bipolar hemiarthroplasty (BHA) in a super-aging area in Japan remain unclear. This study aimed to examine the stem selection policies, the surgeons' concerns about cemented stems, and factors affecting their confidence in their ability to coach others on cemented stem procedures. Ninety-four orthopedic surgeons (27 facilities) responded to our web-based questionnaire conducted in January/February 2022. Cementless stem was the first choice of 97.8% of the surgeons; < 15% of the respondents expected to increase their use of cemented stems in the future. The cement technique was the greatest concern; almost half of the surgeons described having insufficient experience with cemented stems. The factor that most affected the surgeons' expertise in using cemented stems is the number of surgeries they had conducted with a cemented stem (multivariable analysis odds ratio 8.42, p = 0.001). Greater experience was associated with increased expertise of the surgeons in using cemented stems, with a threshold of 11 cases showing sensitivity of 41.7% and specificity of 98.3% for their confidence to instruct cemented stems.
- 1 June 2023
- Vol. 77 (3) , 311-318
Current Femoral Stem Fixation Selection in Hip-Fracture Bipolar Hemiarthroplasties, and Factors Affecting Surgeons' Confidence in Their Ability to Teach about Cemented Stems: A Questionnaire in a Region of Japan with Super-Aged Patients
Japan's hip fracture management guidelines now recommend the use of cemented stems in cases of bone fragility. However, the current stem selection practices in bipolar hemiarthroplasty (BHA) in a super-aging area in Japan remain unclear. This study aimed to examine the stem selection policies, the surgeons' concerns about cemented stems, and factors affecting their confidence in their ability to coach others on cemented stem procedures. Ninety-four orthopedic surgeons (27 facilities) responded to our web-based questionnaire conducted in January/February 2022. Cementless stem was the first choice of 97.8% of the surgeons; < 15% of the respondents expected to increase their use of cemented stems in the future. The cement technique was the greatest concern; almost half of the surgeons described having insufficient experience with cemented stems. The factor that most affected the surgeons' expertise in using cemented stems is the number of surgeries they had conducted with a cemented stem (multivariable analysis odds ratio 8.42, p = 0.001). Greater experience was associated with increased expertise of the surgeons in using cemented stems, with a threshold of 11 cases showing sensitivity of 41.7% and specificity of 98.3% for their confidence to instruct cemented stems.
- Open Access
- 8 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16452
Relationship between Intervertebral Disc Compression Force and Sagittal Spinopelvic Lower Limb Alignment in Elderly Women in Standing Position with Patient-Specific Whole Body Musculoskeletal Model
The intervertebral disc loading based on compensated standing posture in patients with adult spinal deformity remains unclear. We analyzed the relationship between sagittal alignment and disc compression force (). In 14 elderly women, the alignment of the sagittal spinopelvic and lower extremities was measured. was calculated using the Anybody Modeling System. Patients were divided into low sagittal vertical axis (SVA) and high SVA groups. Comparisons between the two groups were performed and the relationship between the and each parameter was examined using Spearman’s correlation coefficient (r). The mean lumbar in the high SVA group was 67.6%; significantly higher than that in the low SVA group (p = 0.046). There was a negative correlation between cervical with T1 slope (r = −0.589, p = 0.034) and lumbar with lumbar lordosis (r = −0.566, p = 0.035). Lumbar was positively correlated with center of gravity-SVA (r = 0.615, p = 0.029), T1 slope (r = 0.613, p = 0.026), and SVA (r = 0.612, p = 0.020). The results suggested sagittal malalignment increased the load on the thoracolumbar and lower lumbar discs and was associated with cervical disc loading.- 8 December 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16452
Open AccessRelationship between Intervertebral Disc Compression Force and Sagittal Spinopelvic Lower Limb Alignment in Elderly Women in Standing Position with Patient-Specific Whole Body Musculoskeletal Model
The intervertebral disc loading based on compensated standing posture in patients with adult spinal deformity remains unclear. We analyzed the relationship between sagittal alignment and disc compression force (). In 14 elderly women, the alignment of the sagittal spinopelvic and lower extremities was measured. was calculated using the Anybody Modeling System. Patients were divided into low sagittal vertical axis (SVA) and high SVA groups. Comparisons between the two groups were performed and the relationship between the and each parameter was examined using Spearman’s correlation coefficient (r). The mean lumbar in the high SVA group was 67.6%; significantly higher than that in the low SVA group (p = 0.046). There was a negative correlation between cervical with T1 slope (r = −0.589, p = 0.034) and lumbar with lumbar lordosis (r = −0.566, p = 0.035). Lumbar was positively correlated with center of gravity-SVA (r = 0.615, p = 0.029), T1 slope (r = 0.613, p = 0.026), and SVA (r = 0.612, p = 0.020). The results suggested sagittal malalignment increased the load on the thoracolumbar and lower lumbar discs and was associated with cervical disc loading. - Open Access
- 24 August 2022
- Published by Springer Nature in Research Square
Current femoral stem fixation in hip arthroplasty for hip fractures after the revised national guidelines in Japan: a questionnaire survey in a super-aging prefectural area
BackgroundThe Japanese guidelines for the management of hip fractures were most recently revised in 2021 to recommend the use of cemented stems in cases of bone fragility. However, the selection of cementless or cemented stem fixations remains controversial. This study aimed to examine the current stem selection strategy in bipolar hemiarthroplasty, concerns about using cemented stems, and factors affecting the ability to instruct cemented stems.MethodsThis study included 94 orthopedic surgeons from 27 facilities who answered a web-based questionnaire survey of 15 questions in the super-aging prefectural area in Japan from January to February 2022. Multiple logistic regression analysis was used to identify the factors associated with the ability to instruct the cemented stem. The cutoff value for the number of cemented stem usage experiences that can be used to instruct cemented stems was determined using the receiver operating characteristic (ROC) curve.ResultsA total of 97.8% of doctors answered that the cementless stem was the current first choice, and 83.0% of doctors had only 0–10 cases of the cemented stem. Meanwhile, only 14.9% of doctors are expected to increase the use of cemented stems in the future. The cement technique was the greatest concern regarding the use of cement stems (60.6%). On multivariate analysis, the number of surgeries of the cemented stem was the factor most affecting the ability to instruct the cemented stem (odds ratio: 8.42, p=0.001). In the ROC curve analysis for the capability of instructing cemented stems and the number of surgeries using cemented stems, the best cutoff value was 1–10 cases (sensitivity, 94.4%; specificity, 58.6%), with an area under the curve of 0.8448 (95% confidence interval: 0.7754–0.9142). When the cut-off value was 11–50 cases, the specificity was higher (sensitivity, 41.7%; specificity, 98.3%).ConclusionsA few doctors still select cemented stems as the first choice. The number of surgeries on the cemented stem was the factor most affecting the ability to instruct the cemented stem, and more than 11 cases are desirable.
- 24 August 2022
- Published by Springer Nature in Research Square
Open AccessCurrent femoral stem fixation in hip arthroplasty for hip fractures after the revised national guidelines in Japan: a questionnaire survey in a super-aging prefectural area
BackgroundThe Japanese guidelines for the management of hip fractures were most recently revised in 2021 to recommend the use of cemented stems in cases of bone fragility. However, the selection of cementless or cemented stem fixations remains controversial. This study aimed to examine the current stem selection strategy in bipolar hemiarthroplasty, concerns about using cemented stems, and factors affecting the ability to instruct cemented stems.MethodsThis study included 94 orthopedic surgeons from 27 facilities who answered a web-based questionnaire survey of 15 questions in the super-aging prefectural area in Japan from January to February 2022. Multiple logistic regression analysis was used to identify the factors associated with the ability to instruct the cemented stem. The cutoff value for the number of cemented stem usage experiences that can be used to instruct cemented stems was determined using the receiver operating characteristic (ROC) curve.ResultsA total of 97.8% of doctors answered that the cementless stem was the current first choice, and 83.0% of doctors had only 0–10 cases of the cemented stem. Meanwhile, only 14.9% of doctors are expected to increase the use of cemented stems in the future. The cement technique was the greatest concern regarding the use of cement stems (60.6%). On multivariate analysis, the number of surgeries of the cemented stem was the factor most affecting the ability to instruct the cemented stem (odds ratio: 8.42, p=0.001). In the ROC curve analysis for the capability of instructing cemented stems and the number of surgeries using cemented stems, the best cutoff value was 1–10 cases (sensitivity, 94.4%; specificity, 58.6%), with an area under the curve of 0.8448 (95% confidence interval: 0.7754–0.9142). When the cut-off value was 11–50 cases, the specificity was higher (sensitivity, 41.7%; specificity, 98.3%).ConclusionsA few doctors still select cemented stems as the first choice. The number of surgeries on the cemented stem was the factor most affecting the ability to instruct the cemented stem, and more than 11 cases are desirable.