DCDing Chen

Ding Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ding Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Liuqing Yu

    A School of Optometry and Ophthalmology and Eye Hospital , Wenzhou Medical University , Wenzhou , Zhejiang , China

    2 shared publications
  • Songjia Liu

    A School of Optometry and Ophthalmology and Eye Hospital , Wenzhou Medical University , Wenzhou , Zhejiang , China

    2 shared publications
  • Yun-E Zhao

    Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China

    2 shared publications
  • Zhangliang Li

    A School of Optometry and Ophthalmology and Eye Hospital , Wenzhou Medical University , Wenzhou , Zhejiang , China

    2 shared publications
  • Dandan Wang

    A School of Optometry and Ophthalmology and Eye Hospital , Wenzhou Medical University , Wenzhou , Zhejiang , China

    1 shared publication
  • Jinhai Huang

    School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China

    1 shared publication

Latest Publications

  • Repeatability of Cornea and Sublayer Thickness Measurements Using Optical Coherence Tomography in Corneas of Anomalous Refractive Status

    by Nan-Ji Lu, Ding Chen, Le-Le Cui, Lin Wang, Shi-Hao Chen, Qin-Mei Wang

    PURPOSE: To assess the repeatability of epithelial, stromal, and total corneal thickness measurements with spectral-domain optical coherence tomography (SD-OCT; RTVue-XR; Optovue, Inc., Fremont, CA) in patients with myopia, keratoconus, and corneas after transepithelial photorefractive keratectomy (PRK), small incision lenticule extraction (SMILE), and femtosecond laser–assisted in situ keratomileusis (FS-LASIK). METHODS: A total of 352 eyes of 352 patients (75 myopic, 68 post-transepithelial PRK, 61 post-SMILE, 75 post-FS-LASIK, 20 mild keratoconus, and 53 advanced keratoconus eyes) were included. The epithelial, stromal, and total corneal thickness were recorded from the pachymetric map in the following four zones: (1) central 2-mm region, (2) eight paracentral regions within 2- to 5-mm diameter, (3) eight midperipheral regions within 5- to 7-mm diameter, and (4) eight peripheral regions within 7- to 9-mm diameter. Three successive scans were performed to evaluate the repeatability. RESULTS: For all zones up to 9-mm diameter, the coefficient of variation (CoV) for epithelial thickness measurements ranged from 1.7% to 3.5% for myopia, 2.6% to 6.2% for post-transepithelial PRK, 2.3% to 4.7% for post-SMILE, 4.0% to 6.3% for post-FS-LASIK, 2.5% to 6.2% for mild keratoconus, and 3.5% to 8.0% for advanced keratoconus. The CoV for stromal and total thickness measurements ranged from 0.2% to 2.0% for myopia, 0.7% to 4.2% for post-transepithelial PRK, 0.3% to 2.4% for post-SMILE, 0.3% to 1.9% for post-FS-LASIK, 0.6% to 3.0% for mild keratoconus, and 1.0% to 5.9% for advanced keratoconus. CONCLUSIONS: RTVue-XR SD-OCT showed excellent repeatability when generating the pachymetric map in myopic eyes. Measurements, especially for epithelial thickness, were relatively more variable for corneas with keratoconus and those having undergone keratorefractive surgery. [ J Refract Surg. 2019;35(9):600–605.]


  • Dysfunctional Lens Index Serves as a Novel Surgery Decision-Maker for Age-Related Nuclear Cataracts

    by Zhangliang Li, Liuqing Yu, Ding Chen, Pingjun Chang, Dandan Wang, Yinying Zhao, Songjia Liu, Yun-E Zhao

    Purpose: To study the correlations between subjective and objective cataract metrics with dysfunctional lens index. To investigate the potential of the DLI as a novel surgery decision-maker. Methods: In this prospective, cross-sectional study, we measured the dysfunctional lens index (DLI), Lens Opacities Classification System III nuclear opalescence (LOCS III NO) grading, preoperative corrected distance visual acuity (CDVA), objective scatter index (OSI) and Scheimpflug-based average lens density (ALD) in eyes with nuclear cataract. Eyes were classified as Surgical and Non-Surgical groups. Correlations among the DLI, OSI, ALD, LOCS III NO grading, and preoperative CDVA were analyzed. The receiver operating characteristic (ROC) curve analysis was performed for DLI, OSI, and CDVA to determine optimal cut-off values to separate between surgical and non-surgical cataracts. Results: The DLI showed the strongest correlation with the OSI (r= −0.712, P< .001), followed by LOCS III NO score (r= −0.661, P< .001), ALD (r= −0.596, P< .001) and preoperative CDVA (r= 0.563, P< .001). The area under ROC curves (AUCs) of the DLI, OSI and preoperative CDVA curve were 0.972, 0.912 and 0.844 (All P< .001), respectively. The DLI cut-off value of 5.7 implied higher levels of sensitivity (91.67%) and specificity (91.84%) than the OSI cut-off value of 2.9 and the CDVA cut-off value of 0.55 (sensitivity of 89.58% and 71.92%; specificity of 81.63% and 85.71%, respectively). Conclusion: The surgery criterion of DLI ≤ 5.7 behaved better than the surgery criterions of OSI ≥ 2.9 and preoperative CDVA ≤ 0.55 in discrimination between surgical and non-surgical nuclear cataracts.


  • Lens nuclear opacity quantitation with long-range swept-source optical coherence tomography: correlation to LOCS III and a Scheimpflug imaging-based grading system

    by Ding Chen, Zhangliang Li, Jinhai Huang, Liuqing Yu, Songjia Liu, Yun-E Zhao

    Purpose: To quantitate lens nuclear opacity using long-range swept-source optical coherence tomography (SS-OCT) images and to evaluate the correlation of this method to Lens Opacities Classification System III (LOCS III) and a Scheimpflug imaging-based grading system (Pentacam Nuclear Stage function; PNS).Methods: This study enrolled 120 participants (120 eyes) with age-related nuclear cataracts. The best-corrected visual acuity (BCVA), LOCS III nuclear opalescence (NO) and nuclear colour (NC) were obtained. The nuclear density measured using PNS function (NDPNS) was recorded. Three successive series of long-range SS-OCT images were captured, and the nuclear region was analysed using ImageJ (NIH, Bethesda, Maryland, USA) to generate SS-OCT image-based nuclear density (NDSS-OCT). The repeatability of NDSS-OCTmeasurement was evaluated using within-subject coefficient of variation (CVw) and intraclass correlation coefficient (ICC). Correlations of NDSS-OCTwith NO and NC, BCVA and NDPNSwere analysed. According to the integrity of nucleus imaged by Pentacam, patients were divided into two groups, and the parameters were compared between groups.Results: The CVwand ICC for NDSS-OCTmeasurement were 1.5 % and 0.994, respectively. The NDSS-OCTsignificantly correlated with NO (r=0.831), NC (r=0.873), BCVA (r=0.655) and NDPNS(r=0.891). The NDSS-OCT, NO and NC, and BCVA were significantly different between the two groups.Conclusion: Lens nuclear opacity quantitation using long-range SS-OCT images was repeatable and correlated well with LOCS III and PNS function. The Scheimpflug principle had a limitation in imaging dense nucleus. Long-range SS-OCT seems more promising for objectively and quantitatively assessing lens nuclear opacity.