THTingbo Hou

Tingbo Hou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tingbo Hou has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pressure Drop and Heat Transfer Performance of Microchannel Heat Exchanger With Circular Reentrant Cavities and Ribs

    by Tingbo Hou, Yuanlong Chen

    The rib arrangement has an important influence on the pressure drop and heat transfer performance of a microchannel heat exchanger (MHE) with circular reentrant cavities and ribs. In this study, four kinds of MHEs with circular reentrant cavity and ribs were designed, namely, circular reentrant cavities (circular), circular reentrant cavities and single-sided ribs (circular—single), circular reentrant cavities and odd-symmetric ribs (circular—odd), and circular reentrant cavities and double symmetric ribs (circular—double). The effect of the rib arrangement on the pressure drop and heat transfer performance of MHEs was numerically investigated by ansysfluent 15.0. The experimental platform was then designed and built for the subsequent experimental verification. The results showed that the pressure drop between the inlet and outlet of the MHE with circular reentrant cavities and ribs increased as the inlet flow increased. At the same inlet flowrate, the pressure drop between the inlet and outlet of the MHEs was largest for the circular reentrant cavities and double symmetric ribs, followed by the circular reentrant cavities and odd-symmetric ribs, circular reentrant cavities and single-sided ribs, and the circular reentrant cavities. The presence of the rib structure increased the inlet and outlet pressure drop of the MHE. The MHE with circular reentrant cavities and double symmetric ribs had the largest inlet and outlet pressure drop, followed by that with circular reentrant cavities and odd-symmetric ribs, that with circular reentrant cavities and single-sided ribs, and that with circular reentrant cavities, indicating that the latter exhibited the best pressure drop performance. At the same inlet flowrate, the MHE with circular reentrant cavities had the highest hot water outlet temperature and the MHE with circular reentrant cavities and double symmetric ribs had the lowest temperature, whereas the results were the opposite for the cold-water outlet temperature. This indicates that the heat transfer performance was best for the MHE with circular reentrant cavities and double symmetric ribs, followed by that with circular reentrant cavities and odd-symmetric ribs and that with circular reentrant cavities and single-sided ribs.


  • Qualitative analysis of coupling effect of fluid velocity distribution in microchannels on the performance of the LED water cooling system

    by Yuanlong Chen, Tingbo Hou, Xiaochao Zhou

    Purpose: The purpose of this paper is to ensure adequate thermal management to remove and dissipate the heat produced by a light-emitting diode (LED) and to guarantee reliable and safe operation. Design/methodology/approach: A three-dimensional (3-D) computational fluid dynamics (CFD) model was used to analyze the distribution of fluid velocities among microchannels at four different aspect ratios. Findings: The results showed that at the same inlet flow rate, the larger the aspect ratio of the microchannels, the better the uniformity of the internal fluid velocity and thus better the heat dissipation performance on the surface of the high-power LED chip. In addition, the thermal performance of a high-power LED water cooling system with four different aspect ratios’ microchannel structures is further studied experimentally. Specifically, the coupling effect between the fluid velocity distribution in the microchannels and the heat dissipation performance of a high-power LED water cooling system is qualitatively analyzed and compared with the simulation results of the fluid velocity distribution. The results fully demonstrated that a larger aspect ratio of the microchannels results in better heat dissipation performance on the surface of the high-power LED chip. Originality/value: Optimizing the structural parameters to facilitate a relatively uniform velocity distribution to improve the water cooling system performance may be a key factor to be considered.


  • Comparative Analysis Between Water-Cooled and Air-Cooled Heat Dissipation in a High-Power Light-Emitting Diode Chipset

    by Yuanlong Chen, Tingbo Hou, Minqiang Pan

    With a substantial increase in thermal power density, the operating temperature of high-power light-emitting diodes (LEDs) rises rapidly, exerting a notable effect on chipsets’ performance. A water-cooled microchannel radiator and an air-cooled radiator are proposed to solve this problem. The effects of key factors of both radiators on heat dissipation in a high-power LED chipsets, and general comparisons between each method, are analyzed via Fluent. The simulation results indicate that heat dissipation from the water-cooled microchannel radiator is readily affected by the microchannel’s flow rate and aspect ratio. A larger flow rate and larger aspect ratio favor improved heat dissipation in the water-cooled microchannel radiator. Heat dissipation in the air-cooled radiator is related to volumetric flow rate, rib number, rib height, rib thickness, and substrate thickness. A larger volumetric flow rate, rib number, and rib height favor heat dissipation in the air-cooled radiator. However, there is a critical thickness value: if the thickness is less than the critical value, heat dissipation is greatly affected by rib thickness and substrate thickness, if the thickness is larger than the critical value, the influence is insignificant. The high-power LED chipsets’ temperature is also related to the insulating substrate’ input power and thermal conductivity. A large input power leads to a substantial increase in temperature, and larger thermal conductivity of the insulating substrate minimizes temperature increase in the high-power LED chipsets. When comparing the two radiators, results show an air-cooled radiator should be used in low-power LED chipsets. When an air-cooled radiator cannot satisfy the chipset’s needs, a water-cooled microchannel radiator should be utilized.