Satoshi Kasai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Satoshi Kasai has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Hiroki Iwase
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), Tokai, Ibaraki 319-1106, Japan
3 shared publications - Hiroshi Kira
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), 162-1 Shirakata, Ibaraki 319-1106, Japan
3 shared publications - Kazuhiro Akutsu-Suyama
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), Tokai, Naka 319-1106, Ibaraki, Japan
3 shared publications - Keiichi Ohuchi
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society, 162-1 Shirakata, Tokai, Ibaraki 319-1106, Japan
3 shared publications - Takayasu Hanashima
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), 162-1 Shirakata, Ibaraki 319-1106, Japan
3 shared publications - Toshiaki Morikawa
Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society (CROSS), Tokai, Ibaraki 319-1106, Japan
3 shared publications
Latest Publications
- Open Access
- 3 December 2025
- Published by MDPI AG in Quantum Beam Science
- Vol. 9 (4) , 35
Implementation and Applications of a Precision Weak-Field Sample Environment for Polarized Neutron Reflectometry at J-PARC
Polarized neutron reflectometry (PNR) analyzes surface and interfacial structures of materials. For the SHARAKU reflectometer at the Materials and Life Science Experimental Facility in the Japan Proton Accelerator Research Complex, precise measurements under weak magnetic fields, which are critical for modern spintronics, have long been challenging. To address this issue, we developed a precise weak-field sample environment equipped with a newly designed coil system. The magnetic field at the sample position can be applied within the surface/interface plane, either in the scattering plane (horizontal configuration) or perpendicular to it (vertical configuration). The horizontal configuration achieved high polarization efficiency across a stable field range, whereas the vertical configuration enabled the experiments to cross zero into negative fields. We demonstrated the instrument’s capability by resolving the remanent magnetic structure of an Fe film. Its applicability to soft matter was proven through analysis of a cellulose thin film with roughness using magnetic contrast variation PNR. In this case, precise weak-field control is essential to tune the magnetic contrast from the reference layer beneath the soft film. These results establish the system as a versatile platform for future PNR and polarized off-specular scattering experiments across a wide range of materials.
- 3 December 2025
- Published by MDPI AG in Quantum Beam Science
- Vol. 9 (4) , 35
Open AccessImplementation and Applications of a Precision Weak-Field Sample Environment for Polarized Neutron Reflectometry at J-PARC
Polarized neutron reflectometry (PNR) analyzes surface and interfacial structures of materials. For the SHARAKU reflectometer at the Materials and Life Science Experimental Facility in the Japan Proton Accelerator Research Complex, precise measurements under weak magnetic fields, which are critical for modern spintronics, have long been challenging. To address this issue, we developed a precise weak-field sample environment equipped with a newly designed coil system. The magnetic field at the sample position can be applied within the surface/interface plane, either in the scattering plane (horizontal configuration) or perpendicular to it (vertical configuration). The horizontal configuration achieved high polarization efficiency across a stable field range, whereas the vertical configuration enabled the experiments to cross zero into negative fields. We demonstrated the instrument’s capability by resolving the remanent magnetic structure of an Fe film. Its applicability to soft matter was proven through analysis of a cellulose thin film with roughness using magnetic contrast variation PNR. In this case, precise weak-field control is essential to tune the magnetic contrast from the reference layer beneath the soft film. These results establish the system as a versatile platform for future PNR and polarized off-specular scattering experiments across a wide range of materials.
- Open Access
- 28 October 2025
- Published by MDPI AG in Preprints.org
Implementation and Applications of a Precision Weak‑Field Sample Environment for Polarized Neutron Reflectometry at J‑PARC
Polarized neutron reflectometry (PNR) analyzes surface and interfacial structures of materials. For the SHARAKU reflectometer at the Materials and Life Science Experimental Facility in the Japan Proton Accelerator Research Complex, precise measurements under weak magnetic fields, which are critical for modern spintronics, have long been challenging. To address this issue, we developed a precise weak-field sample environment equipped with a newly designed coil system. The magnetic field at the sample position can be applied within the surface/interface plane, either in the scattering plane (horizontal configuration) or perpendicular to it (vertical configuration). The horizontal configuration achieved high polarization efficiency across a stable field range, whereas the vertical configuration enabled the experiments to cross zero into negative fields. We demonstrated the instrument’s capability by resolving the remanent magnetic structure of a Fe film. Its applicability to soft-matter was proven through analysis of a cellulose thin film with roughness using magnetic contrast variation PNR. In this case, precise weak-field control is essential to tune the magnetic contrast from the reference layer beneath the soft film. These results establish the system as a versatile platform for future PNR and polarized off-specular scattering experiments across a wide range of materials.
- 28 October 2025
- Published by MDPI AG in Preprints.org
Open AccessImplementation and Applications of a Precision Weak‑Field Sample Environment for Polarized Neutron Reflectometry at J‑PARC
Polarized neutron reflectometry (PNR) analyzes surface and interfacial structures of materials. For the SHARAKU reflectometer at the Materials and Life Science Experimental Facility in the Japan Proton Accelerator Research Complex, precise measurements under weak magnetic fields, which are critical for modern spintronics, have long been challenging. To address this issue, we developed a precise weak-field sample environment equipped with a newly designed coil system. The magnetic field at the sample position can be applied within the surface/interface plane, either in the scattering plane (horizontal configuration) or perpendicular to it (vertical configuration). The horizontal configuration achieved high polarization efficiency across a stable field range, whereas the vertical configuration enabled the experiments to cross zero into negative fields. We demonstrated the instrument’s capability by resolving the remanent magnetic structure of a Fe film. Its applicability to soft-matter was proven through analysis of a cellulose thin film with roughness using magnetic contrast variation PNR. In this case, precise weak-field control is essential to tune the magnetic contrast from the reference layer beneath the soft film. These results establish the system as a versatile platform for future PNR and polarized off-specular scattering experiments across a wide range of materials.
- 23 February 2024
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 57 (2) , 306-313
A high-temperature high-pressure small-angle neutron scattering cell for studying hydrothermal reactions in supercritical water
A high-temperature high-pressure cell equipped with a metallic window was developed for small-angle neutron scattering (SANS). The feasibility of a Ti alloy (Ti–6Al–4V) as a candidate window material was assessed, considering its mechanical strength and neutron characteristics. SANS experiments should be conducted using safe and reliable materials without risk of window damage or leakage of the activated samples due to window breakage. SANS profiles measured for supercritical heavy water showed maximum scattering intensity at temperatures and pressures near the critical density. Additionally, the utility of the cell for observations of the decomposition of plastic in supercritical water is presented. The cell facilitates analysis of reaction mechanisms under sub- and supercritical conditions, which could provide detailed information to aid efficient decomposition and recycling, contributing to a sustainable society.
- 23 February 2024
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 57 (2) , 306-313
A high-temperature high-pressure small-angle neutron scattering cell for studying hydrothermal reactions in supercritical water
A high-temperature high-pressure cell equipped with a metallic window was developed for small-angle neutron scattering (SANS). The feasibility of a Ti alloy (Ti–6Al–4V) as a candidate window material was assessed, considering its mechanical strength and neutron characteristics. SANS experiments should be conducted using safe and reliable materials without risk of window damage or leakage of the activated samples due to window breakage. SANS profiles measured for supercritical heavy water showed maximum scattering intensity at temperatures and pressures near the critical density. Additionally, the utility of the cell for observations of the decomposition of plastic in supercritical water is presented. The cell facilitates analysis of reaction mechanisms under sub- and supercritical conditions, which could provide detailed information to aid efficient decomposition and recycling, contributing to a sustainable society.
- 29 November 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (6) , 1802-1812
Development of a D2O/H2O vapor generator for contrast-variation neutron scattering
The contrast-variation technique in neutron scattering experiments plays a pivotal role in distinguishing partial structures within multi-component complexes, facilitating the elucidation of distinct sample constituents. This differentiation is achieved using different isotopes, namely hydrogen and deuterium, which possess varying neutron scattering characteristics. This study presents a novel vapor generator designed for neutron scattering experiments, enabling continuous control of the D2O/H2O ratio of the vapor. This feature is especially useful for contrast-variation studies. The generator features two saturators and four mass flow controllers, allowing for the rapid and independent generation of D2O/H2O vapors. Additionally, the incorporation of the two-temperature method ensures accurate dew point control within a margin of ±0.2°Cdp. This setup proves useful for conducting time-resolved experiments and can accelerate research on functional polymers, such as polymer electrolyte membranes for fuel cells, where water potential assumes critical importance.
- 29 November 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (6) , 1802-1812
Development of a D2O/H2O vapor generator for contrast-variation neutron scattering
The contrast-variation technique in neutron scattering experiments plays a pivotal role in distinguishing partial structures within multi-component complexes, facilitating the elucidation of distinct sample constituents. This differentiation is achieved using different isotopes, namely hydrogen and deuterium, which possess varying neutron scattering characteristics. This study presents a novel vapor generator designed for neutron scattering experiments, enabling continuous control of the D2O/H2O ratio of the vapor. This feature is especially useful for contrast-variation studies. The generator features two saturators and four mass flow controllers, allowing for the rapid and independent generation of D2O/H2O vapors. Additionally, the incorporation of the two-temperature method ensures accurate dew point control within a margin of ±0.2°Cdp. This setup proves useful for conducting time-resolved experiments and can accelerate research on functional polymers, such as polymer electrolyte membranes for fuel cells, where water potential assumes critical importance.
- 1 February 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (1) , 110-115
New measurement system based on small-angle neutron scattering for structural analysis of light-responsive materials
With the increasing importance of light-responsive materials, it is vital to analyze the relationship between function and structural changes induced by light irradiation. Small-angle scattering (SAS) is effective for such structural analysis. However, quantitatively capturing local molecular structure formation and molecular reactions at a scale of less than 1 nm via SAS is difficult. In this study, to analyze the structure of non-equilibrium phenomena in light-responsive materials, a new sample environment has been developed for a time-of-flight small- and wide-angle neutron scattering instrument (TAIKAN), comprising a UV–Vis irradiation system, UV–Vis absorption measurement equipment and photodetector. Simultaneous measurement of small-angle neutron scattering and UV–Vis absorption was achieved. This system was used to demonstrate the in situ observation of UV–Vis irradiation-induced structural change of micelles formed by 4-butylazobenzene-4′-(oxyethyl)trimethylammonium bromide, which is a light-responsive surfactant, in an aqueous solution. The results showed that the present measuring system provides direct information on the interplay between changes in micelle structure and changes in molecular configuration.
- 1 February 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (1) , 110-115
New measurement system based on small-angle neutron scattering for structural analysis of light-responsive materials
With the increasing importance of light-responsive materials, it is vital to analyze the relationship between function and structural changes induced by light irradiation. Small-angle scattering (SAS) is effective for such structural analysis. However, quantitatively capturing local molecular structure formation and molecular reactions at a scale of less than 1 nm via SAS is difficult. In this study, to analyze the structure of non-equilibrium phenomena in light-responsive materials, a new sample environment has been developed for a time-of-flight small- and wide-angle neutron scattering instrument (TAIKAN), comprising a UV–Vis irradiation system, UV–Vis absorption measurement equipment and photodetector. Simultaneous measurement of small-angle neutron scattering and UV–Vis absorption was achieved. This system was used to demonstrate the in situ observation of UV–Vis irradiation-induced structural change of micelles formed by 4-butylazobenzene-4′-(oxyethyl)trimethylammonium bromide, which is a light-responsive surfactant, in an aqueous solution. The results showed that the present measuring system provides direct information on the interplay between changes in micelle structure and changes in molecular configuration.
- Open Access
Fine-Structure Analysis of Perhydropolysilazane-Derived Nano Layers in Deep-Buried Condition Using Polarized Neutron Reflectometry
A large background scattering originating from the sample matrix is a major obstacle for fine-structure analysis of a nanometric layer buried in a bulk material. As polarization analysis can decrease undesired scattering in a neutron reflectivity (NR) profile, we performed NR experiments with polarization analysis on a polypropylene (PP)/perhydropolysilazane-derived SiO2 (PDS)/Si substrate sample, having a deep-buried layer of SiO2 to elucidate the fine structure of the nano-PDS layer. This method offers unique possibilities for increasing the amplitude of the Kiessig fringes in the higher scattering vector (Qz) region of the NR profiles in the sample by decreasing the undesired background scattering. Fitting and Fourier transform analysis results of the NR data indicated that the synthesized PDS layer remained between the PP plate and Si substrate with a thickness of approximately 109 Å. Furthermore, the scattering length density of the PDS layer, obtained from the background subtracted data appeared to be more accurate than that obtained from the raw data. Although the density of the PDS layer was lower than that of natural SiO2, the PDS thin layer had adequate mechanical strength to maintain a uniform PDS layer in the depth-direction under the deep-buried condition.
Open AccessFine-Structure Analysis of Perhydropolysilazane-Derived Nano Layers in Deep-Buried Condition Using Polarized Neutron Reflectometry
A large background scattering originating from the sample matrix is a major obstacle for fine-structure analysis of a nanometric layer buried in a bulk material. As polarization analysis can decrease undesired scattering in a neutron reflectivity (NR) profile, we performed NR experiments with polarization analysis on a polypropylene (PP)/perhydropolysilazane-derived SiO2 (PDS)/Si substrate sample, having a deep-buried layer of SiO2 to elucidate the fine structure of the nano-PDS layer. This method offers unique possibilities for increasing the amplitude of the Kiessig fringes in the higher scattering vector (Qz) region of the NR profiles in the sample by decreasing the undesired background scattering. Fitting and Fourier transform analysis results of the NR data indicated that the synthesized PDS layer remained between the PP plate and Si substrate with a thickness of approximately 109 Å. Furthermore, the scattering length density of the PDS layer, obtained from the background subtracted data appeared to be more accurate than that obtained from the raw data. Although the density of the PDS layer was lower than that of natural SiO2, the PDS thin layer had adequate mechanical strength to maintain a uniform PDS layer in the depth-direction under the deep-buried condition.
- 22 May 2019
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 21 (1-2) , 23-28
Sample environment equipment for light irradiation experiments at J-PARC
During the past seven years, we have been preparing the sample environment equipment and related devices for light irradiation experiments at the Materials and Life Science Experimental Facility (MLF) in Japan Proton Accelerator Research Complex (J-P
- 22 May 2019
- Published by SAGE Publications in Journal of Neutron Research
- Vol. 21 (1-2) , 23-28
Sample environment equipment for light irradiation experiments at J-PARC
During the past seven years, we have been preparing the sample environment equipment and related devices for light irradiation experiments at the Materials and Life Science Experimental Facility (MLF) in Japan Proton Accelerator Research Complex (J-P