Xudong Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xudong Guo has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
Haipo Cui
Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai, Peoples R China
4 shared publications- Haipo Cui
Shanghai Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, Shanghai 200093, China
4 shared publications Qinfen Jiang
Department of Information Management, Shanghai East Hospital, Tongji University School of Medicine, Shanghai 200120, China
4 shared publications- Yiqi Du
Department of Gastroenterology Changhai Hospital, Naval Medical University Shanghai China
4 shared publications Guojie Zhang
3 shared publicationsHaonan Geng
3 shared publications
Latest Publications
- 18 September 2026
- Published by Zentime Publishing Corporation Limited in Progress in Medical Devices
- Vol. 4 (3) , 216-229
Transformer-based methods for remote photoplethysmography in non-contact physiological measurement: A review
Traditional contact-based physiological monitoring techniques are limited by their comfort and convenience, making them unsuitable for continuous and unobtrusive monitoring in medical environments and daily healthcare applications. Remote photoplethysmography (rPPG) is a non-contact physiological sensing technique that estimates vital physiological signals, such as heart rate and respiration rate, from subtle skin color variations captured in facial videos. However, the practical application of rPPG remains challenging because the physiological signals extracted from facial regions of interest are weak and can be easily overwhelmed by non-stationary noise, such as changes in ambient illumination and subject head motion, resulting in a low signal-to-noise ratio. Recently, Transformer architectures have demonstrated strong capabilities in global dependency modeling through self-attention mechanism, enabling effective extraction of long-range temporal physiological features while suppressing global interference. These advantages provide a new paradigm to overcome the performance bottlenecks of conventional rPPG methods. This review provides a comprehensive overview of recent progress on Transformer-based rPPG research. Specifically, it covers multiple research directions, including pure Transformer end-to-end model, CNN-Transformer hybrid model, multi-stream information fusion frameworks, lightweight models for edge deployment, self-supervised learning frameworks, and extended applications in physiological monitoring. Additionally, this review discusses current limitations and challenges of Transformer-based rPPG systems and highlights future research opportunities for developing new non-contact physiological monitoring technologies.
- 18 September 2026
- Published by Zentime Publishing Corporation Limited in Progress in Medical Devices
- Vol. 4 (3) , 216-229
Transformer-based methods for remote photoplethysmography in non-contact physiological measurement: A review
Traditional contact-based physiological monitoring techniques are limited by their comfort and convenience, making them unsuitable for continuous and unobtrusive monitoring in medical environments and daily healthcare applications. Remote photoplethysmography (rPPG) is a non-contact physiological sensing technique that estimates vital physiological signals, such as heart rate and respiration rate, from subtle skin color variations captured in facial videos. However, the practical application of rPPG remains challenging because the physiological signals extracted from facial regions of interest are weak and can be easily overwhelmed by non-stationary noise, such as changes in ambient illumination and subject head motion, resulting in a low signal-to-noise ratio. Recently, Transformer architectures have demonstrated strong capabilities in global dependency modeling through self-attention mechanism, enabling effective extraction of long-range temporal physiological features while suppressing global interference. These advantages provide a new paradigm to overcome the performance bottlenecks of conventional rPPG methods. This review provides a comprehensive overview of recent progress on Transformer-based rPPG research. Specifically, it covers multiple research directions, including pure Transformer end-to-end model, CNN-Transformer hybrid model, multi-stream information fusion frameworks, lightweight models for edge deployment, self-supervised learning frameworks, and extended applications in physiological monitoring. Additionally, this review discusses current limitations and challenges of Transformer-based rPPG systems and highlights future research opportunities for developing new non-contact physiological monitoring technologies.
- 20 July 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 127
MT-STANet: a multi-task non-contact physiological monitoring from remote PPG
- 20 July 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 127
MT-STANet: a multi-task non-contact physiological monitoring from remote PPG
- 1 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035080
A novel deep learning network for small bowel ulcerative lesion detection and differential diagnosis on double-balloon endoscopy images
Background And Aims. Differentiating small bowel ulcerative diseases (SBUDs) on double-balloon enteroscopy(DBE) is challenging. We aimed to develop an artificial intelligence model using DBE images for accurate SBUD identification and classification. Methods. We retrospectively analyzed 1791 double-balloon endoscopy (DBE) images from 283 patients diagnosed with five types of SBUDs at a single center from August 2020 to May 2023. The cohort included Crohn’s disease ( n = 187), cryptogenic multifocal ulcerous stenosing enteritis (CMUSE) ( n = 37), intestinal tuberculosis ( n = 15), non-specific ulcer ( n = 31), and primary small intestinal lymphoma ( n = 13). Ulcerative lesions were delineated by three endoscopists and finalized by consensus from at least two experts. A novel cascade network, Cascade-E-Yolov7 (EfficientNet-B1 and ESFC-Yolov7), was developed for the classification and precise localization of these lesions. Results. For classification, the model achieved an overall accuracy of 82.35%. The area under the curve was 0.90 for CD, 0.96 for CMUSE, 0.83 for ITB, 0.91 for non-specific ulcers, and 0.95 for PSIL. For lesion detection, the model yielded a mean average precision (mAP@0.5) of 81.35%, a precision of 82.15%, and a recall of 72.67%. Conclusions. The Cascade-E-Yolov7 model accurately detected and classified SBUDs, showing potential as a clinical tool to facilitate diagnosis and reduce experience-dependent variability.
- 1 June 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (3) , 035080
A novel deep learning network for small bowel ulcerative lesion detection and differential diagnosis on double-balloon endoscopy images
Background And Aims. Differentiating small bowel ulcerative diseases (SBUDs) on double-balloon enteroscopy(DBE) is challenging. We aimed to develop an artificial intelligence model using DBE images for accurate SBUD identification and classification. Methods. We retrospectively analyzed 1791 double-balloon endoscopy (DBE) images from 283 patients diagnosed with five types of SBUDs at a single center from August 2020 to May 2023. The cohort included Crohn’s disease ( n = 187), cryptogenic multifocal ulcerous stenosing enteritis (CMUSE) ( n = 37), intestinal tuberculosis ( n = 15), non-specific ulcer ( n = 31), and primary small intestinal lymphoma ( n = 13). Ulcerative lesions were delineated by three endoscopists and finalized by consensus from at least two experts. A novel cascade network, Cascade-E-Yolov7 (EfficientNet-B1 and ESFC-Yolov7), was developed for the classification and precise localization of these lesions. Results. For classification, the model achieved an overall accuracy of 82.35%. The area under the curve was 0.90 for CD, 0.96 for CMUSE, 0.83 for ITB, 0.91 for non-specific ulcers, and 0.95 for PSIL. For lesion detection, the model yielded a mean average precision (mAP@0.5) of 81.35%, a precision of 82.15%, and a recall of 72.67%. Conclusions. The Cascade-E-Yolov7 model accurately detected and classified SBUDs, showing potential as a clinical tool to facilitate diagnosis and reduce experience-dependent variability.
- 10 January 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 109, 103938
UTMorph: A hybrid CNN-transformer network for weakly-supervised multimodal image registration in biopsy puncture
- 10 January 2026
- Published by Elsevier in Medical Image Analysis
- Vol. 109, 103938
UTMorph: A hybrid CNN-transformer network for weakly-supervised multimodal image registration in biopsy puncture
- 2 January 2026
- Published by Springer Nature
- p. 384-391
BiResUNet: A Robust Multi-supervised Segmentation Framework for Prostate Ultrasound and MRI in Robot-Assisted Diagnosis and Treatment
- 2 January 2026
- Published by Springer Nature
- p. 384-391
BiResUNet: A Robust Multi-supervised Segmentation Framework for Prostate Ultrasound and MRI in Robot-Assisted Diagnosis and Treatment
- 28 November 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (5)
Innovative ESCS Bridging System: Enhancing Motor Task‐Specific Activation in Spinal Cord Injury
Epidural spinal cord electrical stimulation (ESCS) offers a promising therapy for restoring lower limb motor function after spinal cord injury. To enhance its efficacy for walking tasks, an advanced ESCS bridging system is developed, integrating a multi‐channel constant current stimulator, touch‐based human‐machine interface, wireless charging module, and implantable flexible multi‐electrode array. A spatiotemporal map of motor neuron activity in rat hindlimb muscles is generated to capture locomotor activation dynamics. This mapping guided the design of a biomimetic multi‐target control algorithm that modulates four stimulation channels in a coordinated temporal sequence. The micro‐electrode array ensures accurate signal transmission and addresses the challenge of electrode misplacement, improving motor output. The system utilizes intermittent burst and “peak‐shaped” modulation waveforms to mimic natural motor patterns. A 3‐month rat study confirmed that the stimulation paradigm effectively induced coordinated, locomotor‐like lower limb muscle activation, improving coordination and motor function. This ESCS system demonstrates strong potential for restoring lower limb mobility through precisely timed and localized spinal cord stimulation.
- 28 November 2025
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (5)
Innovative ESCS Bridging System: Enhancing Motor Task‐Specific Activation in Spinal Cord Injury
Epidural spinal cord electrical stimulation (ESCS) offers a promising therapy for restoring lower limb motor function after spinal cord injury. To enhance its efficacy for walking tasks, an advanced ESCS bridging system is developed, integrating a multi‐channel constant current stimulator, touch‐based human‐machine interface, wireless charging module, and implantable flexible multi‐electrode array. A spatiotemporal map of motor neuron activity in rat hindlimb muscles is generated to capture locomotor activation dynamics. This mapping guided the design of a biomimetic multi‐target control algorithm that modulates four stimulation channels in a coordinated temporal sequence. The micro‐electrode array ensures accurate signal transmission and addresses the challenge of electrode misplacement, improving motor output. The system utilizes intermittent burst and “peak‐shaped” modulation waveforms to mimic natural motor patterns. A 3‐month rat study confirmed that the stimulation paradigm effectively induced coordinated, locomotor‐like lower limb muscle activation, improving coordination and motor function. This ESCS system demonstrates strong potential for restoring lower limb mobility through precisely timed and localized spinal cord stimulation.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Revolutionizing brain–computer interfaces: Compact and high-speed wireless neural signal acquisition
A brain–computer interface (BCI) facilitates the connection between the human brain and external devices by decoding neurophysiological signals, thereby enabling seamless interaction between humans and machines. However, existing neural signal acquisition systems often suffer from limited channel counts, low sampling rates, and challenges in miniaturization and wireless bandwidth, which restrict their ability to support large-scale and real-time neural recordings. Given the rapid advancements in BCI technologies and the increasing demand for high-resolution neural data, there is an imperative need for BCI systems that are high-throughput, high-speed, and miniaturized. This paper presents a wireless neural signal acquisition system based on FPGA technology, supporting 1024 channels at 32 kSPS and employing a stacked architecture for compact, low-power wireless transmission. Following the creation of the functional prototype, laboratory electrical performance tests were conducted. The system exhibited a noise voltage of 8.56 μVrms, which is in close proximity to the 6 μVrms specified by the chip. In addition, the system accurately captured weak sine wave inputs in both time and frequency domains, confirming its ability to record weak bioelectrical signals. Subsequent animal experiments involving mice implanted with EEG electrodes demonstrated that the system could reliably acquire brain neural signals in real time. The maximum and minimum values of signal-to-noise ratios among the channels were measured at 28.66 and 30.56 dB, thereby providing additional validation for the system's signal quality and consistency.
- 1 October 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (10)
Revolutionizing brain–computer interfaces: Compact and high-speed wireless neural signal acquisition
A brain–computer interface (BCI) facilitates the connection between the human brain and external devices by decoding neurophysiological signals, thereby enabling seamless interaction between humans and machines. However, existing neural signal acquisition systems often suffer from limited channel counts, low sampling rates, and challenges in miniaturization and wireless bandwidth, which restrict their ability to support large-scale and real-time neural recordings. Given the rapid advancements in BCI technologies and the increasing demand for high-resolution neural data, there is an imperative need for BCI systems that are high-throughput, high-speed, and miniaturized. This paper presents a wireless neural signal acquisition system based on FPGA technology, supporting 1024 channels at 32 kSPS and employing a stacked architecture for compact, low-power wireless transmission. Following the creation of the functional prototype, laboratory electrical performance tests were conducted. The system exhibited a noise voltage of 8.56 μVrms, which is in close proximity to the 6 μVrms specified by the chip. In addition, the system accurately captured weak sine wave inputs in both time and frequency domains, confirming its ability to record weak bioelectrical signals. Subsequent animal experiments involving mice implanted with EEG electrodes demonstrated that the system could reliably acquire brain neural signals in real time. The maximum and minimum values of signal-to-noise ratios among the channels were measured at 28.66 and 30.56 dB, thereby providing additional validation for the system's signal quality and consistency.
- 30 June 2025
- Published by Zentime Publishing Corporation Limited in Progress in Medical Devices
- p. 85-95
Application of deep learning in the diagnosis of gastrointestinal diseases
With the rapid development of artificial intelligence, deep learning technology has been widely applied across various fields. In the medical field, deep learning models, by analyzing medical images and clinical data, can automatically detect features of different types of lesions, such as polyps, ulcers, and cancers, thereby assisting physicians in early diagnosis of disease. This review provides an overview of recent progress in applying deep learning for disease diagnosis in various parts of the gastrointestinal tract, including the esophagus, stomach, small intestine, and colon. It also discusses the challenges and potential future directions for deep learning in this field.
- 30 June 2025
- Published by Zentime Publishing Corporation Limited in Progress in Medical Devices
- p. 85-95
Application of deep learning in the diagnosis of gastrointestinal diseases
With the rapid development of artificial intelligence, deep learning technology has been widely applied across various fields. In the medical field, deep learning models, by analyzing medical images and clinical data, can automatically detect features of different types of lesions, such as polyps, ulcers, and cancers, thereby assisting physicians in early diagnosis of disease. This review provides an overview of recent progress in applying deep learning for disease diagnosis in various parts of the gastrointestinal tract, including the esophagus, stomach, small intestine, and colon. It also discusses the challenges and potential future directions for deep learning in this field.
- 24 May 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- p. 1-16
Deep ensemble framework with Bayesian optimization for multi-lesion recognition in capsule endoscopy images
In order to address the challenges posed by the large number of images acquired during wireless capsule endoscopy examinations and fatigue-induced leakage and misdiagnosis, a deep ensemble framework is proposed, which consists of CA-EfficientNet-B0, ECA-RegNetY, and Swin transformer as base learners. The ensemble model aims to automatically recognize four lesions in capsule endoscopy images, including angioectasia, bleeding, erosions, and polyps. All the three base learners employed transfer learning, with the inclusion of attention modules in EfficientNet-B0 and RegNetY for optimization. The recognition outcomes from the three base learners were subsequently combined and weighted to facilitate automatic recognition of multi-lesion images and normal images of the gastrointestinal (GI) tract. The weights were determined through the Bayesian optimization. The experiment collected a total of 8358 images of 281 cases at Shanghai East Hospital from 2017 to 2021. These images were organized and labeled by clinicians to verify the performance of the algorithm. The experimental results showed that the model achieved an accuracy of 84.31%, m-Precision of 88.60%, m-Recall of 79.36%, and m-F1-score of 81.08%. Compared to mainstream deep learning models, the ensemble model effectively improves the classification performance of GI diseases and can assist clinicians in making initial diagnoses of GI diseases. Graphical Abstract
- 24 May 2025
- Published by Springer Nature in Medical & Biological Engineering & Computing
- p. 1-16
Deep ensemble framework with Bayesian optimization for multi-lesion recognition in capsule endoscopy images
In order to address the challenges posed by the large number of images acquired during wireless capsule endoscopy examinations and fatigue-induced leakage and misdiagnosis, a deep ensemble framework is proposed, which consists of CA-EfficientNet-B0, ECA-RegNetY, and Swin transformer as base learners. The ensemble model aims to automatically recognize four lesions in capsule endoscopy images, including angioectasia, bleeding, erosions, and polyps. All the three base learners employed transfer learning, with the inclusion of attention modules in EfficientNet-B0 and RegNetY for optimization. The recognition outcomes from the three base learners were subsequently combined and weighted to facilitate automatic recognition of multi-lesion images and normal images of the gastrointestinal (GI) tract. The weights were determined through the Bayesian optimization. The experiment collected a total of 8358 images of 281 cases at Shanghai East Hospital from 2017 to 2021. These images were organized and labeled by clinicians to verify the performance of the algorithm. The experimental results showed that the model achieved an accuracy of 84.31%, m-Precision of 88.60%, m-Recall of 79.36%, and m-F1-score of 81.08%. Compared to mainstream deep learning models, the ensemble model effectively improves the classification performance of GI diseases and can assist clinicians in making initial diagnoses of GI diseases. Graphical Abstract
- 31 March 2025
- Published by Zentime Publishing Corporation Limited in Progress in Medical Devices
- p. 57-65
Gait prediction for lower limb exoskeleton robots based on real-time adaptive Kalman filtering
This paper presents a gait prediction method for lower limb exoskeleton robots using a real-time adaptive Kalman filtering algorithm. The exoskeleton robot targets two user groups: individuals with impaired lower limb motor function requiring rehabilitation training, where the device aids in muscle exercise during walking to facilitate recovery, and healthy individuals using it as a wearable assistive device. To enhance movement intention prediction and improve human-machine coordination, this study focuses on the gait prediction algorithm for walking assistance in healthy users and proposes a gait prediction control strategy based on normal gait orientation. The control system utilizes a microcontroller and Raspberry Pi as its core, enabling functional mode selection through multi-sensor data fusion and effective control of the robot via Bluetooth communication. By comparing the original model algorithm with the proposed real-time updating Kalman filter algorithm, the latter demonstrates feasibility, achieving a prediction error within 1°. This validates the model’s effectiveness in real-time gait prediction.
- 31 March 2025
- Published by Zentime Publishing Corporation Limited in Progress in Medical Devices
- p. 57-65
Gait prediction for lower limb exoskeleton robots based on real-time adaptive Kalman filtering
This paper presents a gait prediction method for lower limb exoskeleton robots using a real-time adaptive Kalman filtering algorithm. The exoskeleton robot targets two user groups: individuals with impaired lower limb motor function requiring rehabilitation training, where the device aids in muscle exercise during walking to facilitate recovery, and healthy individuals using it as a wearable assistive device. To enhance movement intention prediction and improve human-machine coordination, this study focuses on the gait prediction algorithm for walking assistance in healthy users and proposes a gait prediction control strategy based on normal gait orientation. The control system utilizes a microcontroller and Raspberry Pi as its core, enabling functional mode selection through multi-sensor data fusion and effective control of the robot via Bluetooth communication. By comparing the original model algorithm with the proposed real-time updating Kalman filter algorithm, the latter demonstrates feasibility, achieving a prediction error within 1°. This validates the model’s effectiveness in real-time gait prediction.