Erik W. Lentz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Erik W. Lentz has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- David J. E. Marsh
King’s College London
4 shared publications Leslie J Rosenberg
Department of Physics, University of Washington, Seattle, WA 98195-1560, USA
4 shared publications- Xiaolong Du
Carnegie Observatories
4 shared publications A. Sonnenschein
Fermi National Accelerator Laboratory, Batavia, Illinois 60510, USA
3 shared publications- Jiajun Chen
Southwest University
3 shared publications N. Woollett
Lawrence Livermore National Laboratory, Livermore, California 94550, USA
3 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Quantum Computing
- Vol. 7 (2) , 1-34
STQS: A Unified System Architecture for Spatial Temporal Quantum Sensing
We present STQS, a unified system architecture for spatiotemporal quantum sensing that interlaces four key quantum components: sensing , memory , communication , and computation . By employing a comprehensive gate-based framework, we systemically explore the design space of quantum sensing schemes and probe the influence of noise at each state in a sensing workflow through simulation. We introduce a novel distance-based metric that compares reference states to sensing states and assigns a confidence level. We anticipate that the distance measure will serve as an intermediate step toward more advanced quantum signal processing techniques like quantum machine learning. To our knowledge, STQS is the first system-level framework to integrate quantum sensing within a coherent, unified architectural paradigm. STQS provides seamless avenues for unique state preparation, multi-user sensing requests, and addressing practical implementations. We demonstrate the versatility of STQS through evaluations of quantum radar and qubit-based dark matter detection. To highlight the near-term feasibility of our approach, we present results obtained from IBM’s Marrakesh and IonQ’s Forte devices, validating key STQS components on present day quantum hardware. We have made the simulation code and experimental data used in this work publicly available.
- 20 April 2026
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Quantum Computing
- Vol. 7 (2) , 1-34
Open AccessSTQS: A Unified System Architecture for Spatial Temporal Quantum Sensing
We present STQS, a unified system architecture for spatiotemporal quantum sensing that interlaces four key quantum components: sensing , memory , communication , and computation . By employing a comprehensive gate-based framework, we systemically explore the design space of quantum sensing schemes and probe the influence of noise at each state in a sensing workflow through simulation. We introduce a novel distance-based metric that compares reference states to sensing states and assigns a confidence level. We anticipate that the distance measure will serve as an intermediate step toward more advanced quantum signal processing techniques like quantum machine learning. To our knowledge, STQS is the first system-level framework to integrate quantum sensing within a coherent, unified architectural paradigm. STQS provides seamless avenues for unique state preparation, multi-user sensing requests, and addressing practical implementations. We demonstrate the versatility of STQS through evaluations of quantum radar and qubit-based dark matter detection. To highlight the near-term feasibility of our approach, we present results obtained from IBM’s Marrakesh and IonQ’s Forte devices, validating key STQS components on present day quantum hardware. We have made the simulation code and experimental data used in this work publicly available.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04020
Developing centimeter-scale-cavity arrays for axion dark matter detection in the 100 micro-electron-volt range
The cavity haloscope technique has been the most successful approach to date in searching for axion dark matter, owing to a confluence of factors at the GHz scale including the macroscopic size of the axion-to-photon converting cavity volume, the sophistication of present radio-frequency/microwave technologies including quantum amplifiers, and the location of the quantum limit temperature. These factors scale in a disadvantageous way overall as searches move up the axion mass/frequency scale, with the quantum limit noise temperature scaling linearly with frequency T SQL ∼ f , the effective single cavity volume scaling as the inverse frequency cubed CV ∼ -3 , and the axion-coupled cavity mode quality factor shrinking as Q ∼ f -2/3 for copper cavities, necessitating the search for remedies. One approach is to make up the loss in volume using an array of efficiently packed matched cavities coordinated in space and time to act as a single axion-to-photon converting array. This paper presents PNNL's progress in developing technologies for cavity array axion haloscopes in the m a ∼ 100 μeVc 2 mass range including the design of moderate-scale cm-diameter cavities and their fabrication process using electric discharge machining, the development of mode tuning mechanisms towards a re-entrant style combination tuning rod and coupler, mode matching, and RF readout. The result is the first demonstration of a tunable array of matched cavities with axion-coupling modes in the f 0 ∈ [22.88,22.93] GHz (94.62-94.83 μeVc 2 ) range. Prospects for future larger arrays leading to viable axion DM searches of this type in this mass range are discussed.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04020
Open AccessDeveloping centimeter-scale-cavity arrays for axion dark matter detection in the 100 micro-electron-volt range
The cavity haloscope technique has been the most successful approach to date in searching for axion dark matter, owing to a confluence of factors at the GHz scale including the macroscopic size of the axion-to-photon converting cavity volume, the sophistication of present radio-frequency/microwave technologies including quantum amplifiers, and the location of the quantum limit temperature. These factors scale in a disadvantageous way overall as searches move up the axion mass/frequency scale, with the quantum limit noise temperature scaling linearly with frequency T SQL ∼ f , the effective single cavity volume scaling as the inverse frequency cubed CV ∼ -3 , and the axion-coupled cavity mode quality factor shrinking as Q ∼ f -2/3 for copper cavities, necessitating the search for remedies. One approach is to make up the loss in volume using an array of efficiently packed matched cavities coordinated in space and time to act as a single axion-to-photon converting array. This paper presents PNNL's progress in developing technologies for cavity array axion haloscopes in the m a ∼ 100 μeVc 2 mass range including the design of moderate-scale cm-diameter cavities and their fabrication process using electric discharge machining, the development of mode tuning mechanisms towards a re-entrant style combination tuning rod and coupler, mode matching, and RF readout. The result is the first demonstration of a tunable array of matched cavities with axion-coupling modes in the f 0 ∈ [22.88,22.93] GHz (94.62-94.83 μeVc 2 ) range. Prospects for future larger arrays leading to viable axion DM searches of this type in this mass range are discussed.
- Open Access
Developing Centimeter-scale-cavity Arrays for Axion Dark Matter Detection in the 100 Micro-electron-volt Range
The cavity haloscope technique has been the most successful approach to date in searching for axion dark matter, owing to a confluence of factors at the GHz scale including the macroscopic size of the axion-to-photon converting cavity volume, the sophistication of present radio-frequency/microwave technologies including quantum amplifiers, and the location of the quantum limit temperature. These factors scale in a disadvantageous way overall as searches move up the axion mass/frequency scale, with the quantum limit noise temperature scaling linearly with frequency $T_{\text{SQL}} \sim f$, the effective single cavity volume scaling as the inverse frequency cubed $C V \sim f^{-3}$, and the axion-coupled cavity mode quality factor shrinking as $Q \sim f^{-2/3}$ for copper cavities, necessitating the search for remedies. One approach is to make up the loss in volume using an array of efficiently packed matched cavities coordinated in space and time to act as a single axion-to-photon converting array. This paper presents PNNL's progress in developing technologies for cavity array axion haloscope in the $m_a \sim 100$ micro-eV mass range including the design of moderate scale cm-diameter cavities and their fabrication process using electric discharge machining, the development of mode tuning mechanisms towards a re-entrant style combination tuning rod and coupler, mode matching, and RF readout. The result is the first demonstration of a tunable array of matched cavities with axion-coupling modes in the $f_0 \in [22.88,22.93]$ GHz ($94.62-94.83$ micro-eV) range. Prospects for future larger arrays leading to viable axion DM searches of this type in this mass range are discussed.Open AccessDeveloping Centimeter-scale-cavity Arrays for Axion Dark Matter Detection in the 100 Micro-electron-volt Range
The cavity haloscope technique has been the most successful approach to date in searching for axion dark matter, owing to a confluence of factors at the GHz scale including the macroscopic size of the axion-to-photon converting cavity volume, the sophistication of present radio-frequency/microwave technologies including quantum amplifiers, and the location of the quantum limit temperature. These factors scale in a disadvantageous way overall as searches move up the axion mass/frequency scale, with the quantum limit noise temperature scaling linearly with frequency $T_{\text{SQL}} \sim f$, the effective single cavity volume scaling as the inverse frequency cubed $C V \sim f^{-3}$, and the axion-coupled cavity mode quality factor shrinking as $Q \sim f^{-2/3}$ for copper cavities, necessitating the search for remedies. One approach is to make up the loss in volume using an array of efficiently packed matched cavities coordinated in space and time to act as a single axion-to-photon converting array. This paper presents PNNL's progress in developing technologies for cavity array axion haloscope in the $m_a \sim 100$ micro-eV mass range including the design of moderate scale cm-diameter cavities and their fabrication process using electric discharge machining, the development of mode tuning mechanisms towards a re-entrant style combination tuning rod and coupler, mode matching, and RF readout. The result is the first demonstration of a tunable array of matched cavities with axion-coupling modes in the $f_0 \in [22.88,22.93]$ GHz ($94.62-94.83$ micro-eV) range. Prospects for future larger arrays leading to viable axion DM searches of this type in this mass range are discussed. - Open Access
Signatures from Non-classical Features of Axion Dark Matter in Cavity Haloscopes
I present in this article how non-classical features in the local axion dark matter state may imprint on cavity haloscopes. Example signatures from squeezed and pair-entangled DM states are presented and their potential for sensitivity enhancements of experimental searches attuned to these signatures compared to traditional classical field signatures are discussed.
Open AccessSignatures from Non-classical Features of Axion Dark Matter in Cavity Haloscopes
I present in this article how non-classical features in the local axion dark matter state may imprint on cavity haloscopes. Example signatures from squeezed and pair-entangled DM states are presented and their potential for sensitivity enhancements of experimental searches attuned to these signatures compared to traditional classical field signatures are discussed.
- Open Access
- 26 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (1) , 012009
Axion Dark Matter eXperiment: Run 1A analysis details
The ADMX Collaboration gathered data for its Run 1A axion dark matter search from January 2017 to June 2017, scanning with an axion haloscope over the frequency range 645–680 MHz ( in axion mass) at Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) sensitivity. The resulting axion search found no axionlike signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.- 26 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (1) , 012009
Open AccessAxion Dark Matter eXperiment: Run 1A analysis details
The ADMX Collaboration gathered data for its Run 1A axion dark matter search from January 2017 to June 2017, scanning with an axion haloscope over the frequency range 645–680 MHz ( in axion mass) at Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) sensitivity. The resulting axion search found no axionlike signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits. - Open Access
Axion Dark Matter eXperiment: Run 1A Analysis Details
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
Open AccessAxion Dark Matter eXperiment: Run 1A Analysis Details
The ADMX collaboration gathered data for its Run 1A axion dark matter search from January to June 2017, scanning with an axion haloscope over the frequency range 645-680 MHz (2.66-2.81 ueV in axion mass) at DFSZ sensitivity. The resulting axion search found no axion-like signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits.
- Top Cited PapersOpen Access
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Dark matter axion search using a Josephson Traveling wave parametric amplifier
We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10−13 Ge V−1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
- 1 April 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (4)
Top Cited PapersOpen AccessDark matter axion search using a Josephson Traveling wave parametric amplifier
We describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10−13 Ge V−1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.
- 11 July 2022
- Published by American Physical Society (APS) in Physical Review D
- Vol. 106 (2) , 023009
Relaxation times for Bose-Einstein condensation by self-interaction and gravity
In this paper, we study the Bose-Einstein condensation of a scalar field with an attractive self-interaction, with or without gravitational interactions. We confirm through full dynamical simulation that the condensation timescale due to self-interaction is inversely proportional to the square of the number density and the self-coupling constant . We also investigate the condensation timescale when self-interaction and gravity are both important by solving the Gross-Pitaevskii-Poisson equations, and find that the condensation time scales according to an additive model for the cross section. We discuss the relevance of our results to theoretical models of boson star formation by condensation.- 11 July 2022
- Published by American Physical Society (APS) in Physical Review D
- Vol. 106 (2) , 023009
Relaxation times for Bose-Einstein condensation by self-interaction and gravity
In this paper, we study the Bose-Einstein condensation of a scalar field with an attractive self-interaction, with or without gravitational interactions. We confirm through full dynamical simulation that the condensation timescale due to self-interaction is inversely proportional to the square of the number density and the self-coupling constant . We also investigate the condensation timescale when self-interaction and gravity are both important by solving the Gross-Pitaevskii-Poisson equations, and find that the condensation time scales according to an additive model for the cross section. We discuss the relevance of our results to theoretical models of boson star formation by condensation.- Open Access
Relaxation times for Bose-Einstein condensation by self-interaction and gravity
In this paper, we study the Bose-Einstein condensation of a scalar field with an attractive self-interaction, with or without gravitational interactions. We confirm through full dynamical simulation that the condensation timescale due to self-interaction is inversely proportional to the square of the number density $n$ and the self-coupling constant $g$ : $\tau \propto n^{-2} g^{-2}$. We also investigate the condensation timescale when self-interaction and gravity are both important by solving the Gross-Pitaevskii-Poisson equations, and find that the condensation time scales according to an additive model for the cross section. We discuss the relevance of our results to theoretical models of boson star formation by condensation.Open AccessRelaxation times for Bose-Einstein condensation by self-interaction and gravity
In this paper, we study the Bose-Einstein condensation of a scalar field with an attractive self-interaction, with or without gravitational interactions. We confirm through full dynamical simulation that the condensation timescale due to self-interaction is inversely proportional to the square of the number density $n$ and the self-coupling constant $g$ : $\tau \propto n^{-2} g^{-2}$. We also investigate the condensation timescale when self-interaction and gravity are both important by solving the Gross-Pitaevskii-Poisson equations, and find that the condensation time scales according to an additive model for the cross section. We discuss the relevance of our results to theoretical models of boson star formation by condensation. - Open Access
Hyper-Fast Positive Energy Warp Drives
Solitons in space-time capable of transporting time-like observers at superluminal speeds have long been tied to violations of the weak, strong, and dominant energy conditions of general relativity. This trend was recently broken by a new approach that identified soliton solutions capable of superluminal travel while being sourced by purely positive energy densities. This is the first example of hyper-fast solitons satisfying the weak energy condition, reopening the discussion of superluminal mechanisms rooted in conventional physics. This article summarizes the recent finding and its context in the literature. Remaining challenges to autonomous superluminal travel, such as the dominant energy condition, horizons, and the identification of a creation mechanism are also discussed.
Open AccessHyper-Fast Positive Energy Warp Drives
Solitons in space-time capable of transporting time-like observers at superluminal speeds have long been tied to violations of the weak, strong, and dominant energy conditions of general relativity. This trend was recently broken by a new approach that identified soliton solutions capable of superluminal travel while being sourced by purely positive energy densities. This is the first example of hyper-fast solitons satisfying the weak energy condition, reopening the discussion of superluminal mechanisms rooted in conventional physics. This article summarizes the recent finding and its context in the literature. Remaining challenges to autonomous superluminal travel, such as the dominant energy condition, horizons, and the identification of a creation mechanism are also discussed.