CLChing-Wei Lee

Ching-Wei Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ching-Wei Lee has a total of 85 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Right-to-Left Interatrial Shunting After Mitral TEER

    by Su-Chan Chen, Ching-Wei Lee, Chiao-Po Hsu, Shih-Hsien Sung

  • Open Access

    Mitral Valve Lithotripsy With SmartCrack Balloon for Severe Calcified Mitral Stenosis: First‐in‐Human Experience

    by Kent Chak‐Yu So, Kevin Ka‐Ho Kam, Ling Na Geri Wong, Wang Hei Anselm Hui, Ching‐Wei Lee, Tawai Ngernsritrakul, Leo Kar Lok Lai, Simon Chow, Shing Fung Chui, Michael Lee, et al.

    Background: Mitral stenosis due to mitral annular calcification and calcific rheumatic heart disease (CRHD) remains challenging to treat. This first‐in‐human study evaluated the safety and feasibility of the dedicated SmartCrack lithotripsy balloon in patients with severe mitral stenosis secondary to mitral annular calcification or calcific rheumatic heart disease. Methods: High surgical risk patients underwent mitral lithotripsy with the SmartCrack system. Intraoperative measures included mitral valve area, transmitral pressure gradient, and mitral regurgitation severity, assessed pre‐ and post procedure. Follow‐up computed tomography evaluated calcification changes. The primary safety end point was adverse events within 7 days (death, stroke, or procedural complications). The primary efficacy end point was mitral valve area >1.5 cm 2 , ≥50% reduction in transmitral pressure gradient, or transmitral pressure gradient 2 ( P P <0.01). Follow‐up computed tomography revealed calcium cracks in 4 of 5 patients with mitral annular calcification, whereas no cracks were observed in patients with calcific rheumatic heart disease. At 30 days, most patients (n=8/10) reporting symptom improvement. Conclusions: This study demonstrates the procedural feasibility of the SmartCrack lithotripsy balloon when combined with balloon mitral valvuloplasty, potentially modifying valvular calcification and improving mitral valve area. Larger studies are needed to confirm its safety, effectiveness, long‐term durability, and clinical benefits.

  • Coronary Physiologic Burden Assessed by Mean Angiography‐Derived Fractional Flow Reserve Predicts Outcomes After Transcatheter Aortic Valve Implantation

    by Enrico Paolo Legaspi, Patrick W. Serruys, Tsung‐Ying Tsai, Yi‐Lin Tsai, Su‐Chan Chen, Ching‐Wei Lee, Pruthvi C. Revaiah, Tai‐Wei Chen, Chiao‐Po Hsu, Chun‐Chin Chang, et al.

    Background: Coronary artery disease frequently coexists with severe aortic stenosis (AS) and contributes to adverse outcomes after transcatheter aortic valve implantation (TAVI). Conventional lesion‐based assessments may underestimate the cumulative impact of diffuse coronary physiologic impairment in this population. This study evaluated the prognostic significance of mean angiography‐derived fractional flow reserve (vFFR) as a patient‐level marker of coronary physiologic burden in patients undergoing TAVI. Methods: Between January 2017 and April 2022, 164 patients with severe AS who underwent coronary angiography prior to TAVI without significant epicardial stenosis (< 70%) were retrospectively analyzed. vFFR values were computed for all three major coronary arteries, and mean vFFR was calculated for each patient. The primary endpoint was a composite of all‐cause death or heart failure hospitalization (HFH). Mean vFFR was analyzed as a continuous variable. Results: Patients had an overall mean vFFR of 0.89 ± 0.07 and were stratified into high (> 0.85) or low (≤ 0.85) vFFR cohorts. During a mean follow‐up of 1241 ± 867 days, the primary endpoint occurred in 43 patients (26.2%). Lower mean vFFR, lower left ventricular ejection fraction, higher NT‐proBNP levels, lower estimated glomerular filtration rate, and higher STS score were associated with adverse outcomes. In contrast, the lowest single‐vessel vFFR was not associated with the primary endpoint. When analyzed as a continuous variable, each 0.1 decrease in mean vFFR was independently associated with a higher risk of the composite outcome (adjusted hazard ratio 1.62, 95% CI 1.03–2.55; p = 0.035). Restricted cubic spline analysis demonstrated a non‐linear inverse relationship between mean vFFR and clinical risk. Conclusions: Lower mean vFFR, reflecting greater coronary physiologic burden, was independently associated with adverse clinical outcomes after TAVI, even in the absence of angiographically significant stenosis. These findings suggest that patient‐level physiologic impairment may provide incremental prognostic information beyond lesion‐based assessment, supporting a more physiology‐informed approach to coronary evaluation in patients undergoing TAVI.

  • Open Access

    Mitral Regurgitation Phenotype, Coronary Physiology, and Outcomes After Mitral Transcatheter Edge-to-Edge Repair

    by Julian Alexander A. Huibonhoa, Haw-Ruey Hsieh, Ching-Wei Lee, Yi-Lin Tsai, Su-Chan Chen, Tai-Wei Chen, Chun-Chin Chang, Chiao-Po Hsu, Shih-Hsien Sung

  • Remodel the Failed Trifecta or Not: That Is a Question

    by Yi‐Lin Tsai, Ching‐Wei Lee, Su‐Chan Chen, Chun‐Chin Chang, Tai‐Wei Chen, Chiao‐Po Hsu, Shih‐Hsien Sung

    Using a high‐pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non‐fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR). However, the risks and benefits of this approach remain under debate. We present two cases of failed bioprosthetic aortic valves (Trifecta 19 mm and 21 mm, Abbott Vascular) receiving ViV‐TAVR using balloon‐expandable valves (Sapien 3 20‐mm, Edwards Lifesciences). In one patient, an ATLAS GOLD balloon catheter (20 mm, BD, Franklin Lakes, New Jersey, USA) was used to do BVR. In the other patient, a double‐tap technique with the same volume balloon post‐dilatation was performed without BVR. Both procedures were successful, with notable clinical improvement. The post‐TAVR computed tomography and transthoracic echocardiogram were performed 1 month after the procedure which demonstrated comparable hemodynamic results; however, the THV deformation was more pronounced in the patient who underwent BVR. Importantly, the THV‐to‐coronary ostium distance in this patient decreased unexpectedly from 5 mm to near 0 mm over right coronary artery. These cases illustrate that using a high‐pressure balloon to perform BVR in a non‐fracturable surgical valve had limited impact on THV expansion at the annular level. Conversely, unpredictable over‐expansion of the THV in the outflow portion may pose an increased risk to the coronaries, even when the valve‐to‐coronary distance is long prior to the valve‐in‐valve TAVR procedure.

  • Open Access

    Beyond Device Sizing

    by Wei-Ting Sung, Ching-Wei Lee, Shih-Hsien Sung

  • Open Access

    More to Come

    by Ching-Wei Lee, Chun-Chin Chang, Shih-Hsien Sung

  • Why Did UNICORN Fail in Treating Degenerative Bioprosthetic Aortic Valve-in-Valve Procedure?

    by Su-Chan Chen, Yi-Lin Tsai, Chun-Chin Chang, Tai-Wei Chen, Chiao-Po Hsu, Shih-Hsien Sung, Ching-Wei Lee

  • Open Access

    The Right-Heart Paradox

    by Chun-Chin Chang, Ching-Wei Lee, Chiao-Po Hsu, Shih-Hsien Sung

  • Top Cited Papers
    Open Access

    Transcatheter Electrosurgery in the Asia-Pacific

    by Chun-Ka Wong, Karl Poon, Kent Chak-Yu So, Wei-Hsian Yin, Yung-Tsai Lee, Mann Chandavimol, Kwong-Yue Eric Chan, Daniel Tai-Leung Chan, Leo Kar Lok Lai, Kentaro Hayashida, et al.