Ching-Wei Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ching-Wei Lee has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Shih-Hsien Sung
Cardiovascular Center, Taipei Veterans General Hospital, Taipei, Taiwan; Department of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
13 shared publications Chiao-Po Hsu
Cardiovascular Center, Taipei Veterans General Hospital, Taipei, Taiwan; Department of Surgery, National Yang Ming Chiao Tung University, Taipei, Taiwan
4 shared publications- Chun-Chin Chang
Cardiovascular Center, Taipei Veterans General Hospital Taipei Taiwan
4 shared publications Chiao‐Po Hsu
Cardiovascular Center, Taipei Veterans General Hospital Taipei Taiwan
3 shared publicationsChun-Chin Chang
3 shared publications- Kent Chak-Yu So
Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, Chinese University of Hong Kong, Hong Kong SAR, China
3 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (41) , 110354
Right-to-Left Interatrial Shunting After Mitral TEER
- 14 October 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (41) , 110354
Open AccessRight-to-Left Interatrial Shunting After Mitral TEER
- Open Access
- 6 October 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (19) , e050755
Mitral Valve Lithotripsy With SmartCrack Balloon for Severe Calcified Mitral Stenosis: First‐in‐Human Experience
Background: Mitral stenosis due to mitral annular calcification and calcific rheumatic heart disease (CRHD) remains challenging to treat. This first‐in‐human study evaluated the safety and feasibility of the dedicated SmartCrack lithotripsy balloon in patients with severe mitral stenosis secondary to mitral annular calcification or calcific rheumatic heart disease. Methods: High surgical risk patients underwent mitral lithotripsy with the SmartCrack system. Intraoperative measures included mitral valve area, transmitral pressure gradient, and mitral regurgitation severity, assessed pre‐ and post procedure. Follow‐up computed tomography evaluated calcification changes. The primary safety end point was adverse events within 7 days (death, stroke, or procedural complications). The primary efficacy end point was mitral valve area >1.5 cm 2 , ≥50% reduction in transmitral pressure gradient, or transmitral pressure gradient 2 ( P P <0.01). Follow‐up computed tomography revealed calcium cracks in 4 of 5 patients with mitral annular calcification, whereas no cracks were observed in patients with calcific rheumatic heart disease. At 30 days, most patients (n=8/10) reporting symptom improvement. Conclusions: This study demonstrates the procedural feasibility of the SmartCrack lithotripsy balloon when combined with balloon mitral valvuloplasty, potentially modifying valvular calcification and improving mitral valve area. Larger studies are needed to confirm its safety, effectiveness, long‐term durability, and clinical benefits.
- 6 October 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (19) , e050755
Open AccessMitral Valve Lithotripsy With SmartCrack Balloon for Severe Calcified Mitral Stenosis: First‐in‐Human Experience
Background: Mitral stenosis due to mitral annular calcification and calcific rheumatic heart disease (CRHD) remains challenging to treat. This first‐in‐human study evaluated the safety and feasibility of the dedicated SmartCrack lithotripsy balloon in patients with severe mitral stenosis secondary to mitral annular calcification or calcific rheumatic heart disease. Methods: High surgical risk patients underwent mitral lithotripsy with the SmartCrack system. Intraoperative measures included mitral valve area, transmitral pressure gradient, and mitral regurgitation severity, assessed pre‐ and post procedure. Follow‐up computed tomography evaluated calcification changes. The primary safety end point was adverse events within 7 days (death, stroke, or procedural complications). The primary efficacy end point was mitral valve area >1.5 cm 2 , ≥50% reduction in transmitral pressure gradient, or transmitral pressure gradient 2 ( P P <0.01). Follow‐up computed tomography revealed calcium cracks in 4 of 5 patients with mitral annular calcification, whereas no cracks were observed in patients with calcific rheumatic heart disease. At 30 days, most patients (n=8/10) reporting symptom improvement. Conclusions: This study demonstrates the procedural feasibility of the SmartCrack lithotripsy balloon when combined with balloon mitral valvuloplasty, potentially modifying valvular calcification and improving mitral valve area. Larger studies are needed to confirm its safety, effectiveness, long‐term durability, and clinical benefits.
- 17 September 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (6) , 2164-2172
Coronary Physiologic Burden Assessed by Mean Angiography‐Derived Fractional Flow Reserve Predicts Outcomes After Transcatheter Aortic Valve Implantation
Background: Coronary artery disease frequently coexists with severe aortic stenosis (AS) and contributes to adverse outcomes after transcatheter aortic valve implantation (TAVI). Conventional lesion‐based assessments may underestimate the cumulative impact of diffuse coronary physiologic impairment in this population. This study evaluated the prognostic significance of mean angiography‐derived fractional flow reserve (vFFR) as a patient‐level marker of coronary physiologic burden in patients undergoing TAVI. Methods: Between January 2017 and April 2022, 164 patients with severe AS who underwent coronary angiography prior to TAVI without significant epicardial stenosis (< 70%) were retrospectively analyzed. vFFR values were computed for all three major coronary arteries, and mean vFFR was calculated for each patient. The primary endpoint was a composite of all‐cause death or heart failure hospitalization (HFH). Mean vFFR was analyzed as a continuous variable. Results: Patients had an overall mean vFFR of 0.89 ± 0.07 and were stratified into high (> 0.85) or low (≤ 0.85) vFFR cohorts. During a mean follow‐up of 1241 ± 867 days, the primary endpoint occurred in 43 patients (26.2%). Lower mean vFFR, lower left ventricular ejection fraction, higher NT‐proBNP levels, lower estimated glomerular filtration rate, and higher STS score were associated with adverse outcomes. In contrast, the lowest single‐vessel vFFR was not associated with the primary endpoint. When analyzed as a continuous variable, each 0.1 decrease in mean vFFR was independently associated with a higher risk of the composite outcome (adjusted hazard ratio 1.62, 95% CI 1.03–2.55; p = 0.035). Restricted cubic spline analysis demonstrated a non‐linear inverse relationship between mean vFFR and clinical risk. Conclusions: Lower mean vFFR, reflecting greater coronary physiologic burden, was independently associated with adverse clinical outcomes after TAVI, even in the absence of angiographically significant stenosis. These findings suggest that patient‐level physiologic impairment may provide incremental prognostic information beyond lesion‐based assessment, supporting a more physiology‐informed approach to coronary evaluation in patients undergoing TAVI.
- 17 September 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (6) , 2164-2172
Coronary Physiologic Burden Assessed by Mean Angiography‐Derived Fractional Flow Reserve Predicts Outcomes After Transcatheter Aortic Valve Implantation
Background: Coronary artery disease frequently coexists with severe aortic stenosis (AS) and contributes to adverse outcomes after transcatheter aortic valve implantation (TAVI). Conventional lesion‐based assessments may underestimate the cumulative impact of diffuse coronary physiologic impairment in this population. This study evaluated the prognostic significance of mean angiography‐derived fractional flow reserve (vFFR) as a patient‐level marker of coronary physiologic burden in patients undergoing TAVI. Methods: Between January 2017 and April 2022, 164 patients with severe AS who underwent coronary angiography prior to TAVI without significant epicardial stenosis (< 70%) were retrospectively analyzed. vFFR values were computed for all three major coronary arteries, and mean vFFR was calculated for each patient. The primary endpoint was a composite of all‐cause death or heart failure hospitalization (HFH). Mean vFFR was analyzed as a continuous variable. Results: Patients had an overall mean vFFR of 0.89 ± 0.07 and were stratified into high (> 0.85) or low (≤ 0.85) vFFR cohorts. During a mean follow‐up of 1241 ± 867 days, the primary endpoint occurred in 43 patients (26.2%). Lower mean vFFR, lower left ventricular ejection fraction, higher NT‐proBNP levels, lower estimated glomerular filtration rate, and higher STS score were associated with adverse outcomes. In contrast, the lowest single‐vessel vFFR was not associated with the primary endpoint. When analyzed as a continuous variable, each 0.1 decrease in mean vFFR was independently associated with a higher risk of the composite outcome (adjusted hazard ratio 1.62, 95% CI 1.03–2.55; p = 0.035). Restricted cubic spline analysis demonstrated a non‐linear inverse relationship between mean vFFR and clinical risk. Conclusions: Lower mean vFFR, reflecting greater coronary physiologic burden, was independently associated with adverse clinical outcomes after TAVI, even in the absence of angiographically significant stenosis. These findings suggest that patient‐level physiologic impairment may provide incremental prognostic information beyond lesion‐based assessment, supporting a more physiology‐informed approach to coronary evaluation in patients undergoing TAVI.
- Open Access
- 1 September 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (9) , 2140-2143
Mitral Regurgitation Phenotype, Coronary Physiology, and Outcomes After Mitral Transcatheter Edge-to-Edge Repair
- 1 September 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (9) , 2140-2143
Open AccessMitral Regurgitation Phenotype, Coronary Physiology, and Outcomes After Mitral Transcatheter Edge-to-Edge Repair
- 23 August 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Remodel the Failed Trifecta or Not: That Is a Question
Using a high‐pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non‐fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR). However, the risks and benefits of this approach remain under debate. We present two cases of failed bioprosthetic aortic valves (Trifecta 19 mm and 21 mm, Abbott Vascular) receiving ViV‐TAVR using balloon‐expandable valves (Sapien 3 20‐mm, Edwards Lifesciences). In one patient, an ATLAS GOLD balloon catheter (20 mm, BD, Franklin Lakes, New Jersey, USA) was used to do BVR. In the other patient, a double‐tap technique with the same volume balloon post‐dilatation was performed without BVR. Both procedures were successful, with notable clinical improvement. The post‐TAVR computed tomography and transthoracic echocardiogram were performed 1 month after the procedure which demonstrated comparable hemodynamic results; however, the THV deformation was more pronounced in the patient who underwent BVR. Importantly, the THV‐to‐coronary ostium distance in this patient decreased unexpectedly from 5 mm to near 0 mm over right coronary artery. These cases illustrate that using a high‐pressure balloon to perform BVR in a non‐fracturable surgical valve had limited impact on THV expansion at the annular level. Conversely, unpredictable over‐expansion of the THV in the outflow portion may pose an increased risk to the coronaries, even when the valve‐to‐coronary distance is long prior to the valve‐in‐valve TAVR procedure.
- 23 August 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Remodel the Failed Trifecta or Not: That Is a Question
Using a high‐pressure balloon to do bioprosthetic valve remodeling (BVR) for a failed surgical non‐fracturable aortic valve is thought to improve the expansion of a transcatheter heart valve (THV) during valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR). However, the risks and benefits of this approach remain under debate. We present two cases of failed bioprosthetic aortic valves (Trifecta 19 mm and 21 mm, Abbott Vascular) receiving ViV‐TAVR using balloon‐expandable valves (Sapien 3 20‐mm, Edwards Lifesciences). In one patient, an ATLAS GOLD balloon catheter (20 mm, BD, Franklin Lakes, New Jersey, USA) was used to do BVR. In the other patient, a double‐tap technique with the same volume balloon post‐dilatation was performed without BVR. Both procedures were successful, with notable clinical improvement. The post‐TAVR computed tomography and transthoracic echocardiogram were performed 1 month after the procedure which demonstrated comparable hemodynamic results; however, the THV deformation was more pronounced in the patient who underwent BVR. Importantly, the THV‐to‐coronary ostium distance in this patient decreased unexpectedly from 5 mm to near 0 mm over right coronary artery. These cases illustrate that using a high‐pressure balloon to perform BVR in a non‐fracturable surgical valve had limited impact on THV expansion at the annular level. Conversely, unpredictable over‐expansion of the THV in the outflow portion may pose an increased risk to the coronaries, even when the valve‐to‐coronary distance is long prior to the valve‐in‐valve TAVR procedure.
- Open Access
- 15 July 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (28) , 109222
Beyond Device Sizing
- 15 July 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (28) , 109222
Open AccessBeyond Device Sizing
- 22 June 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (12) , 1687-1691
Why Did UNICORN Fail in Treating Degenerative Bioprosthetic Aortic Valve-in-Valve Procedure?
- 22 June 2026
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 19 (12) , 1687-1691
Why Did UNICORN Fail in Treating Degenerative Bioprosthetic Aortic Valve-in-Valve Procedure?
- Open Access
- 4 March 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (9) , 107168
The Right-Heart Paradox
- 4 March 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (9) , 107168
Open AccessThe Right-Heart Paradox
- Top Cited PapersOpen Access
- 6 January 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (1) , 1-15
Transcatheter Electrosurgery in the Asia-Pacific
- 6 January 2026
- Published by Elsevier in JACC: Asia
- Vol. 6 (1) , 1-15
Top Cited PapersOpen AccessTranscatheter Electrosurgery in the Asia-Pacific