JLJong Hoon Lee

Jong Hoon Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jong Hoon Lee has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Trueness and the amount of clinical adjustment for zirconia crowns fabricated by digital light processing at different build angles: a within-patient clinical study

    by Gyeong-Min Kim, KeunBaDa Son, Yoon-Jeong Shin, So-Yeun Kim, Gyu Ri Kim, Kyoung-Jun Jang, Jun Ho Hwang, Jong Hoon Lee, Hyun Deok Kim, Kyu-Bok Lee

    This clinical study evaluated the effect of build angle (0°, 45°, and 90°) in digital light processing (DLP) printing on the trueness and chairside adjustment of zirconia crowns and compared these outcomes with conventionally milled crowns. Ten patients each received one milled zirconia crown and three DLP-printed zirconia crowns fabricated at 0°, 45°, and 90° build angles (40 crowns total; four crowns per patient). Trueness was calculated as the root mean square (RMS) surface deviation between intraoral scans of the crowns and the CAD design. Occlusal and intaglio adjustments were quantified as the RMS deviation between pre- and post-adjustment scans. Data were analyzed using linear mixed-effects models with manufacturing method as a fixed effect and patient as a random intercept to account for within-patient clustering. Post hoc comparisons were performed using Tukey-adjusted pairwise contrasts of estimated marginal means (α = .05). Manufacturing method significantly influenced trueness in the primary linear mixed-effects model (χ2 = 20.689, P = .001). Tukey-adjusted contrasts showed lower RMS for the 0° group (49.0 µm) than for the 45° group (63.3 µm; P = .033), 90° group (70.5 µm; P = .003), and milled group (66.2 µm; P = .012). Manufacturing method also affected occlusal adjustment (χ2 = 13.904, P = .003) and intaglio adjustment (χ2 = 28.624, P < .001). The milled group required more occlusal adjustment than the 0° group (P = .011), and greater intaglio adjustment than all DLP-printed groups (all P ≤ .004). Compared with milling, DLP-printed zirconia crowns demonstrated greater trueness (lower RMS) and required less chairside adjustment. Under the tested conditions, a 0° build angle was associated with the lowest trueness RMS and the least adjustment requirements.

  • Statins enhance efficacy of venetoclax in blood cancers

    by J. Scott Lee, Andrew Roberts, Dennis Juarez, Thanh-Trang T. Vo, Shruti Bhatt, Lee-Or Herzog, Sharmila Mallya, Richard J. Bellin, Suresh K. Agarwal, Ahmed Hamed Salem, et al.

    Statins cooperate with proapoptotic drugs to enhance tumor killing in blood cancers.