Placido Francisco Lizancos Vidal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Placido Francisco Lizancos Vidal has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Joaquim de Moura
Department of Computer Science and Information Technologies, Universidade da Coruña, A Coruña, Spain
22 shared publications - Jorge Novo
Grupo VARPA INIBIC Instituto de Investigacion Biomédica de A Coruña Universidade da Coruña 15006 A Coruña Spain
22 shared publications - Marcos Ortega
Department of Computer Science and Information Technologies, Universidade da Coruña, A Coruña, Spain
22 shared publications - Manuel Gonzalez Penedo
Universidade da Coruña
6 shared publications - Lucía Ramos
Universidade da Coruña
5 shared publications - Eva Castro Lopez
Servicio de Radiodiagnóstico, Complexo Hospitalario Universitario de A Coruña (CHUAC), 15006 A Coruña, Spain
3 shared publications
Latest Publications
- Open Access
- 14 August 2023
- Published by Springer Nature in Applied Intelligence
- Vol. 53 (21) , 25897-25918
Comprehensive fully-automatic multi-depth grading of the clinical types of macular neovascularization in OCTA images
Optical Coherence Tomography Angiography or OCTA represents one of the main means of diagnosis of Age-related Macular Degeneration (AMD), the leading cause of blindness in developed countries. This eye disease is characterized by Macular Neovascularization (MNV), the formation of vessels that tear through the retinal tissues. Four types of MNV can be distinguished, each representing different levels of severity. Both the aggressiveness of the treatment and the recovery of the patient rely on an early detection and correct diagnosis of the stage of the disease. In this work, we propose the first fully-automatic grading methodology that considers all the four clinical types of MNV at the three most relevant OCTA scanning depths for the diagnosis of AMD. We perform both a comprehensive ablation study on the contribution of said depths and an analysis of the attention maps of the network in collaboration with experts of the domain. Our proposal aims to ease the diagnosis burden and decrease the influence of subjectivity on it, offering a explainable grading through the visualization of the attention of the expert models. Our grading proposal achieved satisfactory results with an AUC of 0.9224 ± 0.0381. Additionally, the qualitative analysis performed in collaboration with experts revealed the relevance of the avascular plexus in the grading of all three types of MNV (despite not being directly involved in some of them). Thus, our proposal is not only able to robustly detect MNV in complex scenarios, but also aided to discover previously unconsidered relationships between plexuses.
- 14 August 2023
- Published by Springer Nature in Applied Intelligence
- Vol. 53 (21) , 25897-25918
Open AccessComprehensive fully-automatic multi-depth grading of the clinical types of macular neovascularization in OCTA images
Optical Coherence Tomography Angiography or OCTA represents one of the main means of diagnosis of Age-related Macular Degeneration (AMD), the leading cause of blindness in developed countries. This eye disease is characterized by Macular Neovascularization (MNV), the formation of vessels that tear through the retinal tissues. Four types of MNV can be distinguished, each representing different levels of severity. Both the aggressiveness of the treatment and the recovery of the patient rely on an early detection and correct diagnosis of the stage of the disease. In this work, we propose the first fully-automatic grading methodology that considers all the four clinical types of MNV at the three most relevant OCTA scanning depths for the diagnosis of AMD. We perform both a comprehensive ablation study on the contribution of said depths and an analysis of the attention maps of the network in collaboration with experts of the domain. Our proposal aims to ease the diagnosis burden and decrease the influence of subjectivity on it, offering a explainable grading through the visualization of the attention of the expert models. Our grading proposal achieved satisfactory results with an AUC of 0.9224 ± 0.0381. Additionally, the qualitative analysis performed in collaboration with experts revealed the relevance of the avascular plexus in the grading of all three types of MNV (despite not being directly involved in some of them). Thus, our proposal is not only able to robustly detect MNV in complex scenarios, but also aided to discover previously unconsidered relationships between plexuses.
- Open Access
- 24 January 2023
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 61 (5) , 1209-1224
Multivendor fully automatic uncertainty management approaches for the intuitive representation of DME fluid accumulations in OCT images
Diabetes represents one of the main causes of blindness in developed countries, caused by fluid accumulations in the retinal layers. The clinical literature defines the different types of diabetic macular edema (DME) as cystoid macular edema (CME), diffuse retinal thickening (DRT), and serous retinal detachment (SRD), each with its own clinical relevance. These fluid accumulations do not present defined borders that facilitate segmentational approaches (specially the DRT type, usually not taken into account by the state of the art for this reason) so a diffuse paradigm is used for its detection and visualization. In this paper, we propose three novel approaches for the representation and characterization of these types of DME. A baseline proposal, using a convolutional neural network as backbone, another based on transfer learning from a general domain, and a third approach exploiting information of regions without a defined label. Overall, our baseline proposal obtained an AUC of 0.9583 ± 0.0093, the approach pretrained with a general-domain dataset an AUC of 0.9603 ± 0.0087, and the approach pretrained in the domain taking advantage of uncertainty, an AUC of 0.9619 ± 0.0073.
- 24 January 2023
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 61 (5) , 1209-1224
Open AccessMultivendor fully automatic uncertainty management approaches for the intuitive representation of DME fluid accumulations in OCT images
Diabetes represents one of the main causes of blindness in developed countries, caused by fluid accumulations in the retinal layers. The clinical literature defines the different types of diabetic macular edema (DME) as cystoid macular edema (CME), diffuse retinal thickening (DRT), and serous retinal detachment (SRD), each with its own clinical relevance. These fluid accumulations do not present defined borders that facilitate segmentational approaches (specially the DRT type, usually not taken into account by the state of the art for this reason) so a diffuse paradigm is used for its detection and visualization. In this paper, we propose three novel approaches for the representation and characterization of these types of DME. A baseline proposal, using a convolutional neural network as backbone, another based on transfer learning from a general domain, and a third approach exploiting information of regions without a defined label. Overall, our baseline proposal obtained an AUC of 0.9583 ± 0.0093, the approach pretrained with a general-domain dataset an AUC of 0.9603 ± 0.0087, and the approach pretrained in the domain taking advantage of uncertainty, an AUC of 0.9619 ± 0.0073.
- 15 May 2022
- Published by Springer Nature
- p. 65-76
Pulmonary-Restricted COVID-19 Informative Visual Screening Using Chest X-ray Images from Portable Devices
- 15 May 2022
- Published by Springer Nature
- p. 65-76
Pulmonary-Restricted COVID-19 Informative Visual Screening Using Chest X-ray Images from Portable Devices
- Open Access
- 5 May 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 35 (5) , 1271-1282
Fully-Automatic 3D Intuitive Visualization of Age-Related Macular Degeneration Fluid Accumulations in OCT Cubes
Age-related macular degeneration is the leading cause of vision loss in developed countries, and wet-type AMD requires urgent treatment and rapid diagnosis because it causes rapid irreversible vision loss. Currently, AMD diagnosis is mainly carried out using images obtained by optical coherence tomography. This diagnostic process is performed by human clinicians, so human error may occur in some cases. Therefore, fully automatic methodologies are highly desirable adding a layer of robustness to the diagnosis. In this work, a novel computer-aided diagnosis and visualization methodology is proposed for the rapid identification and visualization of wet AMD. We adapted a convolutional neural network for segmentation of a similar domain of medical images to the problem of wet AMD segmentation, taking advantage of transfer learning, which allows us to work with and exploit a reduced number of samples. We generate a 3D intuitive visualization where the existence, position and severity of the fluid were represented in a clear and intuitive way to facilitate the analysis of the clinicians. The 3D visualization is robust and accurate, obtaining satisfactory 0.949 and 0.960 Dice coefficients in the different evaluated OCT cube configurations, allowing to quickly assess the presence and extension of the fluid associated to wet AMD.
- 5 May 2022
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 35 (5) , 1271-1282
Open AccessFully-Automatic 3D Intuitive Visualization of Age-Related Macular Degeneration Fluid Accumulations in OCT Cubes
Age-related macular degeneration is the leading cause of vision loss in developed countries, and wet-type AMD requires urgent treatment and rapid diagnosis because it causes rapid irreversible vision loss. Currently, AMD diagnosis is mainly carried out using images obtained by optical coherence tomography. This diagnostic process is performed by human clinicians, so human error may occur in some cases. Therefore, fully automatic methodologies are highly desirable adding a layer of robustness to the diagnosis. In this work, a novel computer-aided diagnosis and visualization methodology is proposed for the rapid identification and visualization of wet AMD. We adapted a convolutional neural network for segmentation of a similar domain of medical images to the problem of wet AMD segmentation, taking advantage of transfer learning, which allows us to work with and exploit a reduced number of samples. We generate a 3D intuitive visualization where the existence, position and severity of the fluid were represented in a clear and intuitive way to facilitate the analysis of the clinicians. The 3D visualization is robust and accurate, obtaining satisfactory 0.949 and 0.960 Dice coefficients in the different evaluated OCT cube configurations, allowing to quickly assess the presence and extension of the fluid associated to wet AMD.
- Open Access
- 19 October 2021
- Published by Springer Nature in Pattern Analysis and Applications
- Vol. 25 (1) , 1-15
Feature definition and comprehensive analysis on the robust identification of intraretinal cystoid regions using optical coherence tomography images
Currently, optical coherence tomography is one of the most used medical imaging modalities, offering cross-sectional representations of the studied tissues. This image modality is specially relevant for the analysis of the retina, since it is the internal part of the human body that allows an almost direct examination without invasive techniques. One of the most representative cases of use of this medical imaging modality is for the identification and characterization of intraretinal fluid accumulations, critical for the diagnosis of one of the main causes of blindness in developed countries: the Diabetic Macular Edema. The study of these fluid accumulations is particularly interesting, both from the point of view of pattern recognition and from the different branches of health sciences. As these fluid accumulations are intermingled with retinal tissues, they present numerous variants according to their severity, and change their appearance depending on the configuration of the device; they are a perfect subject for an in-depth research, as they are considered to be a problem without a strict solution. In this work, we propose a comprehensive and detailed analysis of the patterns that characterize them. We employed a pool of 11 different texture and intensity feature families (giving a total of 510 markers) which we have analyzed using three different feature selection strategies and seven complementary classification algorithms. By doing so, we have been able to narrow down and explain the factors affecting this kind of accumulations and tissue lesions by means of machine learning techniques with a pipeline specially designed for this purpose.
- 19 October 2021
- Published by Springer Nature in Pattern Analysis and Applications
- Vol. 25 (1) , 1-15
Open AccessFeature definition and comprehensive analysis on the robust identification of intraretinal cystoid regions using optical coherence tomography images
Currently, optical coherence tomography is one of the most used medical imaging modalities, offering cross-sectional representations of the studied tissues. This image modality is specially relevant for the analysis of the retina, since it is the internal part of the human body that allows an almost direct examination without invasive techniques. One of the most representative cases of use of this medical imaging modality is for the identification and characterization of intraretinal fluid accumulations, critical for the diagnosis of one of the main causes of blindness in developed countries: the Diabetic Macular Edema. The study of these fluid accumulations is particularly interesting, both from the point of view of pattern recognition and from the different branches of health sciences. As these fluid accumulations are intermingled with retinal tissues, they present numerous variants according to their severity, and change their appearance depending on the configuration of the device; they are a perfect subject for an in-depth research, as they are considered to be a problem without a strict solution. In this work, we propose a comprehensive and detailed analysis of the patterns that characterize them. We employed a pool of 11 different texture and intensity feature families (giving a total of 510 markers) which we have analyzed using three different feature selection strategies and seven complementary classification algorithms. By doing so, we have been able to narrow down and explain the factors affecting this kind of accumulations and tissue lesions by means of machine learning techniques with a pipeline specially designed for this purpose.
- Open Access
- 29 September 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 7 (1) , 5
COVID-19 Lung Radiography Segmentation by Means of Multiphase Transfer Learning
COVID-19 is characterized by its impact on the respiratory system and, during the global outbreak of 2020, specific protocols had to be designed to contain its spread within hospitals. This required the use of portable X-ray devices that allow for a greater flexibility in terms of their arrangement in rooms not specifically designed for such purpose. However, their poor image quality, together with the subjectivity of the expert, can hinder the diagnosis process. Therefore, the use of automatic methodologies is advised. Even so, their development is challenging due to the scarcity of available samples. For this reason, we present a COVID-19-specific methodology able to segment these portable chest radiographs with a reduced number of samples via multiple transfer learning phases. This allows us to extract knowledge from two related fields and obtain a robust methodology with limited data from the target domain. Our proposal aims to help both experts and other computer-aided diagnosis systems to focus their attention on the region of interest, ignoring unrelated information.
- 29 September 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 7 (1) , 5
Open AccessCOVID-19 Lung Radiography Segmentation by Means of Multiphase Transfer Learning
COVID-19 is characterized by its impact on the respiratory system and, during the global outbreak of 2020, specific protocols had to be designed to contain its spread within hospitals. This required the use of portable X-ray devices that allow for a greater flexibility in terms of their arrangement in rooms not specifically designed for such purpose. However, their poor image quality, together with the subjectivity of the expert, can hinder the diagnosis process. Therefore, the use of automatic methodologies is advised. Even so, their development is challenging due to the scarcity of available samples. For this reason, we present a COVID-19-specific methodology able to segment these portable chest radiographs with a reduced number of samples via multiple transfer learning phases. This allows us to extract knowledge from two related fields and obtain a robust methodology with limited data from the target domain. Our proposal aims to help both experts and other computer-aided diagnosis systems to focus their attention on the region of interest, ignoring unrelated information.
- Open Access
- 28 September 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 7 (1) , 1
Computational Radiological Screening of Patients with COVID-19 Using Chest X-ray Images from Portable Devices
This work presents a fully automatic system for the screening of chest X-ray images from portable devices under the analysis of three different clinical categories: normal, pathological cases of pulmonary diseases with findings similar to those of COVID-19, and COVID-19 cases. Our methodology was validated using a dataset retrieved specifically for this study, which was provided by the Radiology Service of the Complexo Hospitalario Universitario A Coruña (CHUAC). Despite the poor quality conditions of chest X-ray images acquired by portable devices, satisfactory results were obtained, demonstrating the robustness and great potential of the proposed system to help front-line clinicians in the diagnosis and treatment of patients with COVID-19.
- 28 September 2021
- Published by MDPI AG in Engineering Proceedings
- Vol. 7 (1) , 1
Open AccessComputational Radiological Screening of Patients with COVID-19 Using Chest X-ray Images from Portable Devices
This work presents a fully automatic system for the screening of chest X-ray images from portable devices under the analysis of three different clinical categories: normal, pathological cases of pulmonary diseases with findings similar to those of COVID-19, and COVID-19 cases. Our methodology was validated using a dataset retrieved specifically for this study, which was provided by the Radiology Service of the Complexo Hospitalario Universitario A Coruña (CHUAC). Despite the poor quality conditions of chest X-ray images acquired by portable devices, satisfactory results were obtained, demonstrating the robustness and great potential of the proposed system to help front-line clinicians in the diagnosis and treatment of patients with COVID-19.
- Open Access
- 31 October 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (21) , 7718
Diabetic Macular Edema Characterization and Visualization Using Optical Coherence Tomography Images
Diabetic Retinopathy and Diabetic Macular Edema (DME) represent one of the main causes of blindness in developed countries. They are characterized by fluid deposits in the retinal layers, causing a progressive vision loss over the time. The clinical literature defines three DME types according to the texture and disposition of the fluid accumulations: Cystoid Macular Edema (CME), Diffuse Retinal Thickening (DRT) and Serous Retinal Detachment (SRD). Detecting each one is essential as, depending on their presence, the expert will decide on the adequate treatment of the pathology. In this work, we propose a robust detection and visualization methodology based on the analysis of independent image regions. We study a complete and heterogeneous library of 375 texture and intensity features in a dataset of 356 labeled images from two of the most used capture devices in the clinical domain: a CIRRUSTM HD-OCT 500 Carl Zeiss Meditec and 179 OCT images from a modular HRA + OCT SPECTRALIS® from Heidelberg Engineering, Inc. We extracted 33,810 samples for each type of DME for the feature analysis and incremental training of four different classifier paradigms. This way, we achieved an 84.04% average accuracy for CME, 78.44% average accuracy for DRT and 95.40% average accuracy for SRD. These models are used to generate an intuitive visualization of the fluid regions. We use an image sampling and voting strategy, resulting in a system capable of detecting and characterizing the three types of DME presenting them in an intuitive and repeatable way.
- 31 October 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (21) , 7718
Open AccessDiabetic Macular Edema Characterization and Visualization Using Optical Coherence Tomography Images
Diabetic Retinopathy and Diabetic Macular Edema (DME) represent one of the main causes of blindness in developed countries. They are characterized by fluid deposits in the retinal layers, causing a progressive vision loss over the time. The clinical literature defines three DME types according to the texture and disposition of the fluid accumulations: Cystoid Macular Edema (CME), Diffuse Retinal Thickening (DRT) and Serous Retinal Detachment (SRD). Detecting each one is essential as, depending on their presence, the expert will decide on the adequate treatment of the pathology. In this work, we propose a robust detection and visualization methodology based on the analysis of independent image regions. We study a complete and heterogeneous library of 375 texture and intensity features in a dataset of 356 labeled images from two of the most used capture devices in the clinical domain: a CIRRUSTM HD-OCT 500 Carl Zeiss Meditec and 179 OCT images from a modular HRA + OCT SPECTRALIS® from Heidelberg Engineering, Inc. We extracted 33,810 samples for each type of DME for the feature analysis and incremental training of four different classifier paradigms. This way, we achieved an 84.04% average accuracy for CME, 78.44% average accuracy for DRT and 95.40% average accuracy for SRD. These models are used to generate an intuitive visualization of the fluid regions. We use an image sampling and voting strategy, resulting in a system capable of detecting and characterizing the three types of DME presenting them in an intuitive and repeatable way.
- Open Access
- 26 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 195594-195607
Deep Convolutional Approaches for the Analysis of COVID-19 Using Chest X-Ray Images From Portable Devices
The recent human coronavirus disease (COVID-19) is a respiratory infection caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Given the effects of COVID-19 in pulmonary tissues, chest radiography imaging plays an important role in the screening, early detection, and monitoring of the suspected individuals. Hence, as the pandemic of COVID-19 progresses, there will be a greater reliance on the use of portable equipment for the acquisition of chest X-ray images due to its accessibility, widespread availability, and benefits regarding to infection control issues, minimizing the risk of cross-contamination. This work presents novel fully automatic approaches specifically tailored for the classification of chest X-ray images acquired by portable equipment into 3 different clinical categories: normal, pathological, and COVID-19. For this purpose, 3 complementary deep learning approaches based on a densely convolutional network architecture are herein presented. The joint response of all the approaches allows to enhance the differentiation between patients infected with COVID-19, patients with other diseases that manifest characteristics similar to COVID-19 and normal cases. The proposed approaches were validated over a dataset specifically retrieved for this research. Despite the poor quality of the chest X-ray images that is inherent to the nature of the portable equipment, the proposed approaches provided global accuracy values of 79.62%, 90.27% and 79.86%, respectively, allowing a reliable analysis of portable radiographs to facilitate the clinical decision-making process.
- 26 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 195594-195607
Open AccessDeep Convolutional Approaches for the Analysis of COVID-19 Using Chest X-Ray Images From Portable Devices
The recent human coronavirus disease (COVID-19) is a respiratory infection caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Given the effects of COVID-19 in pulmonary tissues, chest radiography imaging plays an important role in the screening, early detection, and monitoring of the suspected individuals. Hence, as the pandemic of COVID-19 progresses, there will be a greater reliance on the use of portable equipment for the acquisition of chest X-ray images due to its accessibility, widespread availability, and benefits regarding to infection control issues, minimizing the risk of cross-contamination. This work presents novel fully automatic approaches specifically tailored for the classification of chest X-ray images acquired by portable equipment into 3 different clinical categories: normal, pathological, and COVID-19. For this purpose, 3 complementary deep learning approaches based on a densely convolutional network architecture are herein presented. The joint response of all the approaches allows to enhance the differentiation between patients infected with COVID-19, patients with other diseases that manifest characteristics similar to COVID-19 and normal cases. The proposed approaches were validated over a dataset specifically retrieved for this research. Despite the poor quality of the chest X-ray images that is inherent to the nature of the portable equipment, the proposed approaches provided global accuracy values of 79.62%, 90.27% and 79.86%, respectively, allowing a reliable analysis of portable radiographs to facilitate the clinical decision-making process.