Shin Ae Park
Research Subjects
Research Interests
Shin Ae Park has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- András M. Komáromy
Department of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, MI 48824, USA
5 shared publications - Chi Hwan Lee
School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
2 shared publications Dodd Sledge
Veterinary Diagnostic Laboratory Michigan State University, College of Veterinary Medicine East Lansing Michigan USA
2 shared publications- Pete Kollbaum
School of Optometry Indiana University Bloomington Indiana USA
2 shared publications Seul Ah Lee
Weldon School of Biomedical Engineering Purdue University West Lafayette Indiana USA
2 shared publications- Sun Young Kim
Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, United States
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Frontiers Media SA in Frontiers in Ophthalmology
- Vol. 6, 2007280
Positional variance of intraocular pressure in conscious New Zealand white rabbits
Introduction: Glaucoma is one of the leading causes of irreversible vision loss. It is a complex optic neuropathy, with elevated intraocular pressure (IOP) as one of the major risk factors. Recent studies are exploring new devices and technologies for continuous IOP measurement to better monitor glaucoma progression. Rapid and reliable methods for inducing alterations in IOP in laboratory animals may facilitate the development of these technologies. The purpose of this study was to investigate changes in IOP in conscious rabbits placed in different body positions and to assess whether IOP changed with increased duration in each position. Methods: The IOP (mean ± SD mmHg) of twelve New Zealand White (NZW) rabbits, six males and six females, was measured at 1-minute intervals for 5 minutes in prone (19.8 ± 3.7), head-up (18.3 ± 2.7), head-down (22.5 ± 3.6), and supine (23.9 ± 3.8) positions. Results: IOP differed significantly among all positions (p < 0.001). When IOP measurements obtained from minutes 1 to 5 were compared, no significant differences were observed within any position (p > 0.38). Discussion: IOP in rabbits can be significantly altered by changing body position among prone, head-up, head-down, and supine positions. These findings should be considered in future ocular studies using NZW rabbits and may inform further investigations involving continuous IOP-monitoring devices.
- 11 November 2026
- Published by Frontiers Media SA in Frontiers in Ophthalmology
- Vol. 6, 2007280
Open AccessPositional variance of intraocular pressure in conscious New Zealand white rabbits
Introduction: Glaucoma is one of the leading causes of irreversible vision loss. It is a complex optic neuropathy, with elevated intraocular pressure (IOP) as one of the major risk factors. Recent studies are exploring new devices and technologies for continuous IOP measurement to better monitor glaucoma progression. Rapid and reliable methods for inducing alterations in IOP in laboratory animals may facilitate the development of these technologies. The purpose of this study was to investigate changes in IOP in conscious rabbits placed in different body positions and to assess whether IOP changed with increased duration in each position. Methods: The IOP (mean ± SD mmHg) of twelve New Zealand White (NZW) rabbits, six males and six females, was measured at 1-minute intervals for 5 minutes in prone (19.8 ± 3.7), head-up (18.3 ± 2.7), head-down (22.5 ± 3.6), and supine (23.9 ± 3.8) positions. Results: IOP differed significantly among all positions (p < 0.001). When IOP measurements obtained from minutes 1 to 5 were compared, no significant differences were observed within any position (p > 0.38). Discussion: IOP in rabbits can be significantly altered by changing body position among prone, head-up, head-down, and supine positions. These findings should be considered in future ocular studies using NZW rabbits and may inform further investigations involving continuous IOP-monitoring devices.
- Open Access
- 27 August 2026
- Published by Wiley in Advanced Science
- Vol. 13 (63)
Electronics‐Free Visual Monitoring of Dry Eye Disease‐Related Tear Biomarkers Using Smart Scleral Lenses
Dry eye disease (DED) is a prevalent ocular condition characterized by tear film instability, hyperosmolarity, inflammation, and neurosensory abnormalities. Its episodic and fluctuating nature complicates diagnosis and management, as conventional clinical assessments often fail to capture transient tear film changes. Although emerging tear‐sensing technologies show promise, many rely on trained personnel, only sporadic measurements, external readers, or integrated electronics, limiting their practicality for in‐eye applications. Here, we present an electronics‐free scleral lens platform for wearable monitoring of DED‐related tear biomarker changes using passive colorimetric sensors integrated within the lens tear reservoir. This configuration enables visual and smartphone‐assisted readout of chloride ions, pH, and ocular surface temperature within physiologically relevant ranges while avoiding direct contact with the corneal surface. The vaulted scleral lens geometry forms a stable, self‐replenishing tear reservoir that concentrates biomarkers while shielding sensors from corneal contact and eyelid pressure. Sensor color changes are directly observable and quantifiable via a smartphone without specialized readers or user‐specific calibration. Validated using artificial tear fluids, human tear samples, and in vivo models, this platform enables wearable monitoring of DED‐related biomarkers within physiologically relevant ranges, offering a simple and clinically viable approach for tracking ocular surface conditions and associated treatment efficacy.
- 27 August 2026
- Published by Wiley in Advanced Science
- Vol. 13 (63)
Open AccessElectronics‐Free Visual Monitoring of Dry Eye Disease‐Related Tear Biomarkers Using Smart Scleral Lenses
Dry eye disease (DED) is a prevalent ocular condition characterized by tear film instability, hyperosmolarity, inflammation, and neurosensory abnormalities. Its episodic and fluctuating nature complicates diagnosis and management, as conventional clinical assessments often fail to capture transient tear film changes. Although emerging tear‐sensing technologies show promise, many rely on trained personnel, only sporadic measurements, external readers, or integrated electronics, limiting their practicality for in‐eye applications. Here, we present an electronics‐free scleral lens platform for wearable monitoring of DED‐related tear biomarker changes using passive colorimetric sensors integrated within the lens tear reservoir. This configuration enables visual and smartphone‐assisted readout of chloride ions, pH, and ocular surface temperature within physiologically relevant ranges while avoiding direct contact with the corneal surface. The vaulted scleral lens geometry forms a stable, self‐replenishing tear reservoir that concentrates biomarkers while shielding sensors from corneal contact and eyelid pressure. Sensor color changes are directly observable and quantifiable via a smartphone without specialized readers or user‐specific calibration. Validated using artificial tear fluids, human tear samples, and in vivo models, this platform enables wearable monitoring of DED‐related biomarkers within physiologically relevant ranges, offering a simple and clinically viable approach for tracking ocular surface conditions and associated treatment efficacy.
- Open Access
- 22 July 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (5) , e70233
Limited Efficacy of Autologous Mesenchymal Stromal Cell Injections in Immunomodulatory‐Dependent Dogs With Aqueous Deficient Dry Eye Disease
Objective: Aqueous deficient dry eye disease (ADDE) results from a quantitative reduction in aqueous tears. We sought to determine the clinical effect of autologous mesenchymal stromal cell (MSC) injections into the region of the lacrimal gland and the gland of the third eyelid in immunomodulatory‐dependent ADDE‐affected dogs. Methods: Dogs ( n = 4) were enrolled that met the inclusion criteria for ADDE (consistent clinical signs combined with Schirmer tear test I [STT‐I] value < 15 mm/min, responsive to topical immunomodulatory therapy, and documented drop in STT‐I after cessation of therapy). By applying these stringent criteria, there was a high failure rate for inclusion. Autologous MSCs were harvested, expanded, and unilaterally injected after cessation of immunomodulatory therapy. Examinations, ophthalmic diagnostics, clinical scoring, and owner surveys were performed at regular intervals post‐injection. Results: No adverse ocular events were associated with the MSC injections. There were variable responses between dogs, with one dog exhibiting an immediate increase in STT‐I that remained elevated (5.5‐fold increase); two dogs had a smaller and temporary increase in STT‐I over baseline (0.6–0.7‐fold increases), and one dog had no increases detected over the initial 6 months. Repeated injections did not improve clinical or diagnostic values. Conclusions: Autologous MSC injections were well‐tolerated in dogs with ADDE. Results were variable in this small sample size. Despite initial improvement in 3 of 4 dogs, the positive response was variable in magnitude of response and duration of effect. Repeated injections did not sustain this response. Future studies using conditioned MSCs and/or exosomal therapy are warranted.
- 22 July 2026
- Published by Wiley in Veterinary Ophthalmology
- Vol. 29 (5) , e70233
Open AccessLimited Efficacy of Autologous Mesenchymal Stromal Cell Injections in Immunomodulatory‐Dependent Dogs With Aqueous Deficient Dry Eye Disease
Objective: Aqueous deficient dry eye disease (ADDE) results from a quantitative reduction in aqueous tears. We sought to determine the clinical effect of autologous mesenchymal stromal cell (MSC) injections into the region of the lacrimal gland and the gland of the third eyelid in immunomodulatory‐dependent ADDE‐affected dogs. Methods: Dogs ( n = 4) were enrolled that met the inclusion criteria for ADDE (consistent clinical signs combined with Schirmer tear test I [STT‐I] value < 15 mm/min, responsive to topical immunomodulatory therapy, and documented drop in STT‐I after cessation of therapy). By applying these stringent criteria, there was a high failure rate for inclusion. Autologous MSCs were harvested, expanded, and unilaterally injected after cessation of immunomodulatory therapy. Examinations, ophthalmic diagnostics, clinical scoring, and owner surveys were performed at regular intervals post‐injection. Results: No adverse ocular events were associated with the MSC injections. There were variable responses between dogs, with one dog exhibiting an immediate increase in STT‐I that remained elevated (5.5‐fold increase); two dogs had a smaller and temporary increase in STT‐I over baseline (0.6–0.7‐fold increases), and one dog had no increases detected over the initial 6 months. Repeated injections did not improve clinical or diagnostic values. Conclusions: Autologous MSC injections were well‐tolerated in dogs with ADDE. Results were variable in this small sample size. Despite initial improvement in 3 of 4 dogs, the positive response was variable in magnitude of response and duration of effect. Repeated injections did not sustain this response. Future studies using conditioned MSCs and/or exosomal therapy are warranted.
- Open Access
- 16 July 2024
- Published by Wiley in Veterinary Ophthalmology
- Vol. 28 (4) , 753-758
Microphthalmia with multiple ocular abnormalities in a foal
Objective: The aim of this report was to provide a clinical description and clinical, ultrasonographic, and histologic images of a foal with microphthalmia and multiple ocular abnormalities.Animals Studied: A 12‐h old Friesian‐American Paint Horse crossbred filly presented for blindness, microphthalmia and marked ventral strabismus in both eyes.Procedure: A complete ophthalmic examination was performed. Ultrasound biomicroscopy and B‐mode ultrasonography were performed. The globes were submitted for histopathology.Results: Ultrasound biomicroscopy demonstrated a hyperechoic cornea void of the typical epithelium, stroma, and Descemet's membrane layers. The anterior chamber was spanned by thick strands of hyperechoic tissue extending from the iris to the cornea. The lens was not visualized. B‐mode ultrasound showed aphakia and mild, mottled echogenicity within the vitreous with no evidence of retinal detachment. On histopathology, both globes were microphthalmic with poorly defined corneal tissue. The anterior chambers were poorly formed and contained lacrimal glandular tissue. Portions of iridal tissue were present, but no lenses were noted. The retinas were segmentally detached and markedly atrophied with areas of retina dysplasia noted.Conclusions: This report provides a clinical, ultrasonographic and histologic description of a rare, congenital condition in a foal characterized by microphthalmia, aphakia, poorly defined corneal tissue, choristomatous differentiation of the anterior segment and retinal dysplasia.
- 16 July 2024
- Published by Wiley in Veterinary Ophthalmology
- Vol. 28 (4) , 753-758
Open AccessMicrophthalmia with multiple ocular abnormalities in a foal
Objective: The aim of this report was to provide a clinical description and clinical, ultrasonographic, and histologic images of a foal with microphthalmia and multiple ocular abnormalities.Animals Studied: A 12‐h old Friesian‐American Paint Horse crossbred filly presented for blindness, microphthalmia and marked ventral strabismus in both eyes.Procedure: A complete ophthalmic examination was performed. Ultrasound biomicroscopy and B‐mode ultrasonography were performed. The globes were submitted for histopathology.Results: Ultrasound biomicroscopy demonstrated a hyperechoic cornea void of the typical epithelium, stroma, and Descemet's membrane layers. The anterior chamber was spanned by thick strands of hyperechoic tissue extending from the iris to the cornea. The lens was not visualized. B‐mode ultrasound showed aphakia and mild, mottled echogenicity within the vitreous with no evidence of retinal detachment. On histopathology, both globes were microphthalmic with poorly defined corneal tissue. The anterior chambers were poorly formed and contained lacrimal glandular tissue. Portions of iridal tissue were present, but no lenses were noted. The retinas were segmentally detached and markedly atrophied with areas of retina dysplasia noted.Conclusions: This report provides a clinical, ultrasonographic and histologic description of a rare, congenital condition in a foal characterized by microphthalmia, aphakia, poorly defined corneal tissue, choristomatous differentiation of the anterior segment and retinal dysplasia.
- Open Access
- 12 June 2024
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 11, 1372802
Case report: Unilateral papilledema in a dog with a large suprasellar mass and suspected intracranial hypertension: insights from funduscopy, optical coherence tomography, and magnetic resonance imaging
A spayed, 8-year-old female Poodle, weighing 5.7 kg, was presented with the chief complaint of vision impairment. Vision assessment, including pupillary light reflexes, menace response, dazzle reflex, and maze navigation in photopic and scotopic circumstances, revealed a negative response in both eyes except for positive direct pupillary light reflex in the right eye and positive consensual pupillary light reflex from the right eye to the left eye. Systemic evaluation, including neurologic status, blood profile, and thoracic radiographs, did not reveal any abnormalities. Complete ophthalmic examinations, ocular ultrasonography, and electroretinography did not identify a cause of blindness. Upon funduscopy, the left eye exhibited an increased optic disk diameter, blurred optic disk borders, and loss of the physiologic pit, as well as an increase in vascular tortuosity. In the right eye, there were multifocal depigmented areas in the non-tapetal fundus and several pigmented spots surrounded by a region of dull tapetal reflection in the tapetal fundus. The optical coherence tomography revealed severe anterior deformation of the optic nerve head and Bruch’s membrane in the peripapillary region of the left eye. Magnetic resonance imaging revealed an irregular, broad-based suprasellar mass, with features suggestive of intracranial hypertension, including dorsal displacement of third ventricles, a rightward shift of the falx cerebri, trans-tentorial herniation, perilesional edema, flattening/protrusion of the posterior sclera, and lager optic nerve sheath diameter in left side than right side. This is the first comprehensive report that describes unilateral papilledema in a dog with a brain tumor, using advanced ophthalmic and neuro-imaging modalities.
- 12 June 2024
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 11, 1372802
Open AccessCase report: Unilateral papilledema in a dog with a large suprasellar mass and suspected intracranial hypertension: insights from funduscopy, optical coherence tomography, and magnetic resonance imaging
A spayed, 8-year-old female Poodle, weighing 5.7 kg, was presented with the chief complaint of vision impairment. Vision assessment, including pupillary light reflexes, menace response, dazzle reflex, and maze navigation in photopic and scotopic circumstances, revealed a negative response in both eyes except for positive direct pupillary light reflex in the right eye and positive consensual pupillary light reflex from the right eye to the left eye. Systemic evaluation, including neurologic status, blood profile, and thoracic radiographs, did not reveal any abnormalities. Complete ophthalmic examinations, ocular ultrasonography, and electroretinography did not identify a cause of blindness. Upon funduscopy, the left eye exhibited an increased optic disk diameter, blurred optic disk borders, and loss of the physiologic pit, as well as an increase in vascular tortuosity. In the right eye, there were multifocal depigmented areas in the non-tapetal fundus and several pigmented spots surrounded by a region of dull tapetal reflection in the tapetal fundus. The optical coherence tomography revealed severe anterior deformation of the optic nerve head and Bruch’s membrane in the peripapillary region of the left eye. Magnetic resonance imaging revealed an irregular, broad-based suprasellar mass, with features suggestive of intracranial hypertension, including dorsal displacement of third ventricles, a rightward shift of the falx cerebri, trans-tentorial herniation, perilesional edema, flattening/protrusion of the posterior sclera, and lager optic nerve sheath diameter in left side than right side. This is the first comprehensive report that describes unilateral papilledema in a dog with a brain tumor, using advanced ophthalmic and neuro-imaging modalities.
- 24 September 2022
- Published by Wiley in Veterinary Ophthalmology
- Vol. 26 (2) , 176-179
Two is not necessarily better than one: A double lens in a pre‐metamorphic adult axolotl (Ambystoma mexicanum)
An 8-year-old female pre-metamorphic axolotl (Ambystoma mexicanum) was examined for a suspected anterior lens luxation. Slit-lamp biomicroscopy revealed two lens-like structures in the anterior chamber of the right eye (OD), each with cataractous change. Ultrasound biomicroscopy and optical coherence tomography (OCT) were performed without sedation, and revealed small lenticular structures each with distinct nuclei and cortices. Although a distinct connection of the two lenticular structures could not be definitively ruled out, the structures appeared separate. Each of the lenticular structures was closely associated with its respective iris leaflet. This report demonstrates application of advanced imaging for diagnostic use in axolotl ophthalmology, showing that imaging of the lens can be performed without sedation, topical anesthetic, nor contact gel with high diagnostic quality. Although two distinct lenses were diagnosed with no historical evidence of trauma, the small sizes of each lenticular structure, with no detectable connection between them, are suggestive of a possible regenerative abnormality. This report opens discussion for the regenerative capabilities of the pre-metamorphic adult axolotl and possible implementations of their use in regenerative medicine research for the development of future therapies.
- 24 September 2022
- Published by Wiley in Veterinary Ophthalmology
- Vol. 26 (2) , 176-179
Two is not necessarily better than one: A double lens in a pre‐metamorphic adult axolotl (Ambystoma mexicanum)
An 8-year-old female pre-metamorphic axolotl (Ambystoma mexicanum) was examined for a suspected anterior lens luxation. Slit-lamp biomicroscopy revealed two lens-like structures in the anterior chamber of the right eye (OD), each with cataractous change. Ultrasound biomicroscopy and optical coherence tomography (OCT) were performed without sedation, and revealed small lenticular structures each with distinct nuclei and cortices. Although a distinct connection of the two lenticular structures could not be definitively ruled out, the structures appeared separate. Each of the lenticular structures was closely associated with its respective iris leaflet. This report demonstrates application of advanced imaging for diagnostic use in axolotl ophthalmology, showing that imaging of the lens can be performed without sedation, topical anesthetic, nor contact gel with high diagnostic quality. Although two distinct lenses were diagnosed with no historical evidence of trauma, the small sizes of each lenticular structure, with no detectable connection between them, are suggestive of a possible regenerative abnormality. This report opens discussion for the regenerative capabilities of the pre-metamorphic adult axolotl and possible implementations of their use in regenerative medicine research for the development of future therapies.
- Top Cited PapersOpen Access
- 20 September 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-15
Smart soft contact lenses for continuous 24-hour monitoring of intraocular pressure in glaucoma care
Continuous monitoring of intraocular pressure, particularly during sleep, remains a grand challenge in glaucoma care. Here we introduce a class of smart soft contact lenses, enabling the continuous 24-hour monitoring of intraocular pressure, even during sleep. Uniquely, the smart soft contact lenses are built upon various commercial brands of soft contact lenses without altering their intrinsic properties such as lens power, biocompatibility, softness, transparency, wettability, oxygen transmissibility, and overnight wearability. We show that the smart soft contact lenses can seamlessly fit across different corneal curvatures and thicknesses in human eyes and therefore accurately measure absolute intraocular pressure under ambulatory conditions. We perform a comprehensive set of in vivo evaluations in rabbit, dog, and human eyes from normal to hypertension to confirm the superior measurement accuracy, within-subject repeatability, and user comfort of the smart soft contact lenses beyond current wearable ocular tonometers. We envision that the smart soft contact lenses will be effective in glaucoma care.
- 20 September 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-15
Top Cited PapersOpen AccessSmart soft contact lenses for continuous 24-hour monitoring of intraocular pressure in glaucoma care
Continuous monitoring of intraocular pressure, particularly during sleep, remains a grand challenge in glaucoma care. Here we introduce a class of smart soft contact lenses, enabling the continuous 24-hour monitoring of intraocular pressure, even during sleep. Uniquely, the smart soft contact lenses are built upon various commercial brands of soft contact lenses without altering their intrinsic properties such as lens power, biocompatibility, softness, transparency, wettability, oxygen transmissibility, and overnight wearability. We show that the smart soft contact lenses can seamlessly fit across different corneal curvatures and thicknesses in human eyes and therefore accurately measure absolute intraocular pressure under ambulatory conditions. We perform a comprehensive set of in vivo evaluations in rabbit, dog, and human eyes from normal to hypertension to confirm the superior measurement accuracy, within-subject repeatability, and user comfort of the smart soft contact lenses beyond current wearable ocular tonometers. We envision that the smart soft contact lenses will be effective in glaucoma care.
- 22 July 2022
- Published by Wiley in Veterinary Ophthalmology
- Vol. 26 (2) , 161-168
Stenting of a partially obstructed nasolacrimal duct using a steerable angle‐tipped hydrophilic guidewire in a cat
Objective: This case report describes the successful correction of partial obstruction of the NL duct in a cat by means of a modified retrograde NL duct cannulation using a steerable angle‐tipped hydrophilic guidewire (AH guidewire) following a paranasal incision.Animal Studied: A 2‐year‐old neutered male American domestic shorthair cat was referred to the Purdue University Veterinary Hospital (PUVH) for chronic epiphora suspected secondary to nasolacrimal (NL) system obstruction.Procedures: At the first visit, the cat had epiphora OD and facial dermatitis but no other abnormalities on physical and ophthalmic examinations. Computed tomography (CT)‐dacryocystorhinography revealed partial obstruction of the NL duct secondary to stenosis near the distal root of the right maxillary third premolar (107). A digital three‐dimensional (3D) model of the right maxilla and NL duct was created for inspection and virtual cannulation of the NL. The model was 3D printed and cannulation of the NL duct was rehearsed with various stent materials. Retrograde NL stenting with the guidance of a steerable angle‐tipped hydrophilic guidewire was conducted following a paranasal incision. A urethral catheter was cannulated over the guidewire and maintained for 44 days.Results: The epiphora resolved immediately after stenting. At 21 days post‐stenting, the cat developed acute bullous keratopathy secondary to self‐trauma which was treated with a third eyelid flap. On the final follow‐up communication with the owner at 210 days post‐stenting, no epiphora or any other concerns were reported.Conclusion: To the authors' knowledge, this is the first report of successful NL stenting and resolution of epiphora in a cat with a partial NL system obstruction.
- 22 July 2022
- Published by Wiley in Veterinary Ophthalmology
- Vol. 26 (2) , 161-168
Stenting of a partially obstructed nasolacrimal duct using a steerable angle‐tipped hydrophilic guidewire in a cat
Objective: This case report describes the successful correction of partial obstruction of the NL duct in a cat by means of a modified retrograde NL duct cannulation using a steerable angle‐tipped hydrophilic guidewire (AH guidewire) following a paranasal incision.Animal Studied: A 2‐year‐old neutered male American domestic shorthair cat was referred to the Purdue University Veterinary Hospital (PUVH) for chronic epiphora suspected secondary to nasolacrimal (NL) system obstruction.Procedures: At the first visit, the cat had epiphora OD and facial dermatitis but no other abnormalities on physical and ophthalmic examinations. Computed tomography (CT)‐dacryocystorhinography revealed partial obstruction of the NL duct secondary to stenosis near the distal root of the right maxillary third premolar (107). A digital three‐dimensional (3D) model of the right maxilla and NL duct was created for inspection and virtual cannulation of the NL. The model was 3D printed and cannulation of the NL duct was rehearsed with various stent materials. Retrograde NL stenting with the guidance of a steerable angle‐tipped hydrophilic guidewire was conducted following a paranasal incision. A urethral catheter was cannulated over the guidewire and maintained for 44 days.Results: The epiphora resolved immediately after stenting. At 21 days post‐stenting, the cat developed acute bullous keratopathy secondary to self‐trauma which was treated with a third eyelid flap. On the final follow‐up communication with the owner at 210 days post‐stenting, no epiphora or any other concerns were reported.Conclusion: To the authors' knowledge, this is the first report of successful NL stenting and resolution of epiphora in a cat with a partial NL system obstruction.
- Open Access
- 22 July 2022
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 9, 959782
Case report: Presumed contact lens-induced intracorneal hemorrhage in a diabetic dog
A 10-year-old castrated male miniature poodle dog with diabetes mellitus was presented for a week history of blepharospasm and epiphora in the right eye. The spontaneous chronic corneal epithelial defect (SCCED) was diagnosed, and a bandage contact lens was applied following corneal debridement with sterile cotton-tip applicators. In 1 week, SCCED was improving uneventfully, though an annular pattern of intracorneal hemorrhage was observed. The contact lens was removed and the intracorneal hemorrhage resorbed in 4 weeks. To the author's knowledge, this is the first report of presumed contact lens-induced intracorneal hemorrhage characterized by an annular pattern in a dog.
- 22 July 2022
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 9, 959782
Open AccessCase report: Presumed contact lens-induced intracorneal hemorrhage in a diabetic dog
A 10-year-old castrated male miniature poodle dog with diabetes mellitus was presented for a week history of blepharospasm and epiphora in the right eye. The spontaneous chronic corneal epithelial defect (SCCED) was diagnosed, and a bandage contact lens was applied following corneal debridement with sterile cotton-tip applicators. In 1 week, SCCED was improving uneventfully, though an annular pattern of intracorneal hemorrhage was observed. The contact lens was removed and the intracorneal hemorrhage resorbed in 4 weeks. To the author's knowledge, this is the first report of presumed contact lens-induced intracorneal hemorrhage characterized by an annular pattern in a dog.