Jeffrey M. Goshe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeffrey M. Goshe has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Justis P. Ehlers
The Tony and Leona Campane Center for Excellence in Image-Guided Surgery and Advanced Imaging Research, Cleveland Clinic, Cleveland, OH 44195, USA
2 shared publications Sunil K. Srivastava
Department of Ophthalmology, Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA; Tony and Leona Campane Center for Excellence in Image-Guided Surgery and Advanced Imaging Research, Cleveland Clinic, Cleveland, Ohio, USA
2 shared publicationsAndrew P. Schachat
Cleveland Clinic Cole Eye Institute, Cleveland, OH, USA
1 shared publicationAparna S. Patel
Department of Ophthalmology, Cleveland Clinic Cole Eye Institute, Cleveland, Ohio, USA
1 shared publication- Asmita Indurkar
The Tony and Leona Campane Center for Excellence in Image-Guided Surgery and Advanced Imaging Research, Cleveland Clinic, Cleveland, OH 44195, USA
1 shared publication Brandon J. Baartman
Cole Eye Institute, Cleveland Clinic Foundation, Cleveland, OH
1 shared publication
Latest Publications
- Open Access
- 30 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1394
The Feasibility and Clinical Evaluation of an Immersive Augmented Reality Surgical Headset Integrated with Swept-Source Intraoperative Optical Coherence Tomography for Ophthalmic Surgery in the DISCOVER Study
Objectives: to evaluate the feasibility and utility of intraoperative optical coherence tomography (iOCT) utilizing an immersive augmented reality surgical headset (Beyeonics iOCT, Beyeonics Vision Ltd., Haifa, Israel) digital visualization platform with swept-source integrated OCT in ophthalmic surgery. Methods: As part of the Institutional Review Board-approved prospective DISCOVER study, the Beyeonics iOCT was utilized in multiple ophthalmic surgical procedures to evaluate the feasibility and utility of iOCT with this platform. The Beyeonics iOCT is a three-dimensional surgical visualization system that utilizes a swept-source integrated OCT within the digital microscope system. Surgeon feedback on system performance and integration into the surgical workflow was gathered via a prespecified survey. Results: Thirteen eyes of thirteen patients were included in this study. The surgical procedures consisted of four cataract surgeries, two lamellar corneal transplants, one pterygium removal, and six vitreoretinal surgeries. Surgeons were able to successfully view and review the iOCT images within the surgical Head-Mounted Display, eliminating the need for an external display. Utility feedback from surgeons included iOCT assisting with confirming wound architecture, corneal graft orientation, and retinal structure. All surgeries were completed without reverting to a conventional microscope, and no intraoperative adverse events occurred. Conclusions: The new visualization platform with integrated swept-source iOCT demonstrated feasibility and potential utility in multiple ophthalmic surgical platforms. Additional research related to outcomes, ergonomics, and enhanced software analysis is needed in the future.
- 30 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1394
Open AccessThe Feasibility and Clinical Evaluation of an Immersive Augmented Reality Surgical Headset Integrated with Swept-Source Intraoperative Optical Coherence Tomography for Ophthalmic Surgery in the DISCOVER Study
Objectives: to evaluate the feasibility and utility of intraoperative optical coherence tomography (iOCT) utilizing an immersive augmented reality surgical headset (Beyeonics iOCT, Beyeonics Vision Ltd., Haifa, Israel) digital visualization platform with swept-source integrated OCT in ophthalmic surgery. Methods: As part of the Institutional Review Board-approved prospective DISCOVER study, the Beyeonics iOCT was utilized in multiple ophthalmic surgical procedures to evaluate the feasibility and utility of iOCT with this platform. The Beyeonics iOCT is a three-dimensional surgical visualization system that utilizes a swept-source integrated OCT within the digital microscope system. Surgeon feedback on system performance and integration into the surgical workflow was gathered via a prespecified survey. Results: Thirteen eyes of thirteen patients were included in this study. The surgical procedures consisted of four cataract surgeries, two lamellar corneal transplants, one pterygium removal, and six vitreoretinal surgeries. Surgeons were able to successfully view and review the iOCT images within the surgical Head-Mounted Display, eliminating the need for an external display. Utility feedback from surgeons included iOCT assisting with confirming wound architecture, corneal graft orientation, and retinal structure. All surgeries were completed without reverting to a conventional microscope, and no intraoperative adverse events occurred. Conclusions: The new visualization platform with integrated swept-source iOCT demonstrated feasibility and potential utility in multiple ophthalmic surgical platforms. Additional research related to outcomes, ergonomics, and enhanced software analysis is needed in the future.
- 13 December 2024
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (4) , e558-e565
Inpatient topical glaucoma medication-ordering discrepancies: a study of frequency and risk factors for inaccurate reconciliation
- 13 December 2024
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 60 (4) , e558-e565
Inpatient topical glaucoma medication-ordering discrepancies: a study of frequency and risk factors for inaccurate reconciliation
- Open Access
- 7 November 2024
- Published by Association of University Professors of Ophthalmology in Journal of Academic Ophthalmology
- Vol. 16 (1) , 9
There’s No Place Like Home: Evaluating Trends in the 2023 Ophthalmology Match
Objective: The aim of this study was to evaluate trends in home-institution match rates during the 2023 ophthalmology match cycle and identify factors contributing to the observed rise in home-institution matching. Design: We obtained match results from the 2023 SF match database and annotated each applicant with their home institution. Chi-squared tests were used to compare 2023 home institution match rates with match rates from preceding years. Additionally, we retrieved data on letter writers and their primary affiliations for 441 applicants from the 2023 Cole Eye match database. Spearman correlation analysis was performed to determine the relationship between letter writer affiliation and whether applicants matched at their home institution. Results: In 2023, the home institution match rate was significantly higher than rates in years preceding the COVID-19 pandemic (2017-2020). Furthermore, the number of home institution-affiliated letter writers positively correlated (r = .3, p < .0001) with and increased the likelihood of an applicant matching at their home institution (RR 4.5, CI: 2.2-9.4, p = 0.0001). Conclusions: Despite easing pandemic restriction on away rotations, home-institution match rates for ophthalmology applicants remained elevated in 2023. We also found that the primary affiliation of letter writers was an important factor influencing where an applicant matches.
- 7 November 2024
- Published by Association of University Professors of Ophthalmology in Journal of Academic Ophthalmology
- Vol. 16 (1) , 9
Open AccessThere’s No Place Like Home: Evaluating Trends in the 2023 Ophthalmology Match
Objective: The aim of this study was to evaluate trends in home-institution match rates during the 2023 ophthalmology match cycle and identify factors contributing to the observed rise in home-institution matching. Design: We obtained match results from the 2023 SF match database and annotated each applicant with their home institution. Chi-squared tests were used to compare 2023 home institution match rates with match rates from preceding years. Additionally, we retrieved data on letter writers and their primary affiliations for 441 applicants from the 2023 Cole Eye match database. Spearman correlation analysis was performed to determine the relationship between letter writer affiliation and whether applicants matched at their home institution. Results: In 2023, the home institution match rate was significantly higher than rates in years preceding the COVID-19 pandemic (2017-2020). Furthermore, the number of home institution-affiliated letter writers positively correlated (r = .3, p < .0001) with and increased the likelihood of an applicant matching at their home institution (RR 4.5, CI: 2.2-9.4, p = 0.0001). Conclusions: Despite easing pandemic restriction on away rotations, home-institution match rates for ophthalmology applicants remained elevated in 2023. We also found that the primary affiliation of letter writers was an important factor influencing where an applicant matches.
- 1 February 2020
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 210, 167-173
Intraoperative Optical Coherence Tomography–Assisted Descemet Membrane Endothelial Keratoplasty in the DISCOVER Study: First 100 Cases
- 1 February 2020
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 210, 167-173
Intraoperative Optical Coherence Tomography–Assisted Descemet Membrane Endothelial Keratoplasty in the DISCOVER Study: First 100 Cases
- Open Access
- 1 June 2018
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 10, 159-162
Spontaneous regression of epithelial downgrowth from clear corneal phacoemulsification wound
- 1 June 2018
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 10, 159-162
Open AccessSpontaneous regression of epithelial downgrowth from clear corneal phacoemulsification wound
- 1 April 2018
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 53 (2) , 131-134
Prednisolone versus dexamethasone for prevention of pseudophakic cystoid macular edema
- 1 April 2018
- Published by Elsevier in Canadian Journal of Ophthalmology
- Vol. 53 (2) , 131-134
Prednisolone versus dexamethasone for prevention of pseudophakic cystoid macular edema
- 1 September 2014
- Published by Wolters Kluwer Health in Cornea
- Vol. 33 (9) , 887-892
Association Between Transient Interface Fluid on Intraoperative OCT and Textural Interface Opacity After DSAEK Surgery in the PIONEER Study
Purpose: The aim of this study was to examine the association between transient interface fluid (TIF) and textural interface opacity (TIO) after Descemet stripping automated endothelial keratoplasty (DSAEK) surgery using intraoperative optical coherence tomography (iOCT) in the PIONEER (Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy) study. Methods: All consecutive eyes that underwent DSAEK between October 2011 and September 2013 from the PIONEER intraoperative and perioperative OCT study were included. iOCT images were captured after lenticule apposition with complete air fill and after air-fluid exchange. Postoperative day 1 OCT images were obtained. Outcome variables included the presence of TIO at the graft–host junction and the presence of intraoperative and postoperative interface fluid on OCT. Results: Seventy-six eyes from 69 patients who underwent DSAEK with iOCT were included. The mean age of the patients was 71 years (range 31–90). The 2 most common indications for surgery were Fuchs dystrophy (63%) and pseudophakic bullous keratopathy (24%). In 18 of 76 (23.7%) eyes, TIF was visible on iOCT post air-fluid exchange. Of these eyes, 14 developed TIO. TIO was observed in 18 of 76 (23.7%) eyes. TIF on iOCT was associated with a significantly higher rate of postoperative TIO (odds ratio = 47.25; P < 0.0001). Sixteen of the 18 eyes that had TIF on iOCT had had resolution on the postoperative day 1 OCT. There was no significant difference in the mean graft thickness between eyes with TIF on iOCT and those without (P = 0.58). Conclusions: Eyes with TIF on iOCT are more likely to develop TIO in the postoperative period. It is believed that the process of gap closure results in TIO, possibly secondary to precipitated solutes, retained viscoelastic, or lamellar irregularities caused by delayed adhesion or uneven matching of lamellar fibrils.
- 1 September 2014
- Published by Wolters Kluwer Health in Cornea
- Vol. 33 (9) , 887-892
Association Between Transient Interface Fluid on Intraoperative OCT and Textural Interface Opacity After DSAEK Surgery in the PIONEER Study
Purpose: The aim of this study was to examine the association between transient interface fluid (TIF) and textural interface opacity (TIO) after Descemet stripping automated endothelial keratoplasty (DSAEK) surgery using intraoperative optical coherence tomography (iOCT) in the PIONEER (Prospective Intraoperative and Perioperative Ophthalmic ImagiNg with Optical CoherEncE TomogRaphy) study. Methods: All consecutive eyes that underwent DSAEK between October 2011 and September 2013 from the PIONEER intraoperative and perioperative OCT study were included. iOCT images were captured after lenticule apposition with complete air fill and after air-fluid exchange. Postoperative day 1 OCT images were obtained. Outcome variables included the presence of TIO at the graft–host junction and the presence of intraoperative and postoperative interface fluid on OCT. Results: Seventy-six eyes from 69 patients who underwent DSAEK with iOCT were included. The mean age of the patients was 71 years (range 31–90). The 2 most common indications for surgery were Fuchs dystrophy (63%) and pseudophakic bullous keratopathy (24%). In 18 of 76 (23.7%) eyes, TIF was visible on iOCT post air-fluid exchange. Of these eyes, 14 developed TIO. TIO was observed in 18 of 76 (23.7%) eyes. TIF on iOCT was associated with a significantly higher rate of postoperative TIO (odds ratio = 47.25; P < 0.0001). Sixteen of the 18 eyes that had TIF on iOCT had had resolution on the postoperative day 1 OCT. There was no significant difference in the mean graft thickness between eyes with TIF on iOCT and those without (P = 0.58). Conclusions: Eyes with TIF on iOCT are more likely to develop TIO in the postoperative period. It is believed that the process of gap closure results in TIO, possibly secondary to precipitated solutes, retained viscoelastic, or lamellar irregularities caused by delayed adhesion or uneven matching of lamellar fibrils.