JDJohn Charles Clifford Day

John Charles Clifford Day

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John Charles Clifford Day has a total of 102 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-Range Imaging of Alpha Emitters Using Radioluminescence in Open Environments: Daytime and Night-Time Applications

    by Lingteng Kong, Thomas Bligh Scott, John Charles Clifford Day, David Andrew Megson-Smith

    Alpha emitters like plutonium pose severe health risks when ingested, damaging DNA and potentially causing cancer. Traditional detection methods require proximity within millimeters of the contamination source, presenting safety risks and operational inefficiencies. Long-range detection through alpha radioluminescence (RL) offers a promising alternative. However, most of the previous experiments have been carried out under controlled conditions that preclude the overwhelming effect of ambient light. This study demonstrates the successful detection of a 3 MBq alpha emitter in an open environment using a compact alpha camera. This camera incorporates a deep-cooled CCD and a low f-number lens system designed to minimize the blue shift effects of filters. Night-time imaging was achieved with a dual-filter system using a sandwich filter assembly centered at 337 nm and 343 nm for capturing alpha RL and subtracting background light, respectively. At night, the alpha source was detected from 1 m away within one minute, and the lowest detection limit can be calculated as 75 kBq. The system was also evaluated under simulated urban lighting conditions. For daytime imaging, a stack of tilted 276 nm short pass filters minimized sunlight interference, enabling the detection of the alpha source at 70 cm within 10 min under indirect sunlight. This research highlights the viability of long-range optical detection of alpha emitters for environmental monitoring in real-world settings.


  • Open Access

    Long-Range Imaging of Alpha Emitters Using Radioluminescence in Open Environments: Daytime and Nighttime Applications

    by Lingteng Kong, Thomas Bligh Scott, John Charles Clifford Day, David Andrew Megson-Smith

    Alpha emitters like plutonium pose severe health risks when ingested, damaging DNA and potentially causing cancer. Traditional detection methods require proximity within millimeters of the contamination source, presenting safety risks and operational inefficiencies. Long-range detection through alpha radioluminescence (RL) offers a promising alternative. However, most of the previous experiments have been carried out under controlled conditions that preclude the overwhelming effect of ambient light. This study demonstrates successful detection of a 3 MBq alpha emitter in an open environment using a newly developed, lightweight compact alpha camera. This camera incorporates a deep-cooled CCD and a specially designed lens system with a low f-number to maximum the signal intensity. The lens was also designed to minimize blue shift effects of filters. Nighttime imaging was achieved with a dual-filter system using a sandwich filters assembly centered at 337 nm and 343 nm for capturing alpha RL and subtracting background light, respectively. At night, the alpha source was detected from 1 meter away within one minute. The system was also evaluated under simulated urban lighting conditions. For daytime imaging, a stack of tilted 276 nm short pass filters minimized sunlight interference, enabling clear detection of the alpha source at 70 cm within 10 minutes under indirect sunlight. This research not only underscores the viability of long-range optical detection of alpha emitters for environmental monitoring and scientific research but also highlights its ability to enhance nuclear safety and public health in real-world settings.

  • Open Access

    Advancements in Remote Alpha Radiation Detection: Alpha-Induced Radio-Luminescence Imaging with Enhanced Ambient Light Suppression

    by Lingteng Kong, Thomas Bligh Scott, John Charles Clifford Day, David Andrew Megson-Smith

    Heavy nuclides like uranium and their decay products are commonly found in nuclear industries and can pose a significant health risk to humans due to their alpha-emitting properties. Traditional alpha detectors require close contact with the contaminated surface, which can be time-consuming, labour-intensive, and put personnel at risk. Remote detection is urgently needed but very challenging. To this end, a candidate detection mechanism is alpha-induced radio-luminescence. This approach uses the emission of photons from radio-ionised excited nitrogen molecules to imply the presence of alpha emitters from a distance. Herein, the use of this phenomenon to remotely image various alpha emitters with unparalleled levels of sensitivity and spatial accuracy is demonstrated. Notably, the system detected a 29 kBq Am-241 source at a distance of 3 m within 10 min. Furthermore, it demonstrated the capability to discern a 29 kBq source positioned 7 cm away from a 3 MBq source at a 2 m distance. Additionally, a ‘sandwich’ filter structure is described that incorporates an absorptive filter between two interference filters to enhance the ambient light rejection. The testing of the system is described in different lighting environments, including room light and inside a glovebox. This method promises safer and more efficient alpha monitoring, with applications in nuclear forensics, waste management and decommissioning.


  • Open Access

    Combining electromyography and Raman spectroscopy: optical EMG

    by James J. P. Alix, Maria Plesia, Pamela J. Shaw, Richard J. Mead, John C. C. Day

    Introduction/Aims: Electromyography (EMG) remains a key component of the diagnostic work‐up for suspected neuromuscular disease, but it does not provide insight into the molecular composition of muscle which can provide diagnostic information. Raman spectroscopy is an emerging neuromuscular biomarker capable of generating highly specific, molecular fingerprints of tissue. Here, we present “optical EMG,” a combination of EMG and Raman spectroscopy, achieved using a single needle.Methods: An optical EMG needle was created to collect electrophysiological and Raman spectroscopic data during a single insertion. We tested functionality with in vivo recordings in the SOD1G93A mouse model of amyotrophic lateral sclerosis (ALS), using both transgenic (n = 10) and non‐transgenic (NTg, n = 7) mice. Under anesthesia, compound muscle action potentials (CMAPs), spontaneous EMG activity and Raman spectra were recorded from both gastrocnemius muscles with the optical EMG needle. Standard concentric EMG needle recordings were also undertaken. Electrophysiological data were analyzed with standard univariate statistics, Raman data with both univariate and multivariate analyses.Results: A significant difference in CMAP amplitude was observed between SOD1G93A and NTg mice with optical EMG and standard concentric needles (p = .015 and p = .011, respectively). Spontaneous EMG activity (positive sharp waves) was detected in transgenic SOD1G93A mice only. Raman spectra demonstrated peaks associated with key muscle components. Significant differences in molecular composition between SOD1G93A and NTg muscle were identified through the Raman spectra.Discussion: Optical EMG can provide standard electrophysiological data and molecular Raman data during a single needle insertion and represents a potential biomarker for neuromuscular disease.


  • Open Access

    Non‐negative matrix factorisation of Raman spectra finds common patterns relating to neuromuscular disease across differing equipment configurations, preclinical models and human tissue

    by James J. P. Alix, Maria Plesia, Chlöe N. Schooling, Alexander P. Dudgeon, Catherine A. Kendall, Visakan Kadirkamanathan, Christopher J. McDermott, Gráinne S. Gorman, Robert W. Taylor, Richard J. Mead, et al.

    Raman spectroscopy shows promise as a biomarker for complex nerve and muscle (neuromuscular) diseases. To maximise its potential, several challenges remain. These include the sensitivity to different instrument configurations, translation across preclinical/human tissues and the development of multivariate analytics that can derive interpretable spectral outputs for disease identification. Nonnegative matrix factorisation (NMF) can extract features from high-dimensional data sets and the nonnegative constraint results in physically realistic outputs. In this study, we have undertaken NMF on Raman spectra of muscle obtained from different clinical and preclinical settings. First, we obtained and combined Raman spectra from human patients with mitochondrial disease and healthy volunteers, using both a commercial microscope and in-house fibre optic probe. NMF was applied across all data, and spectral patterns common to both equipment configurations were identified. Linear discriminant models utilising these patterns were able to accurately classify disease states (accuracy 70.2-84.5%). Next, we applied NMF to spectra obtained from the mdx mouse model of a Duchenne muscular dystrophy and patients with dystrophic muscle conditions. Spectral fingerprints common to mouse/human were obtained and able to accurately identify disease (accuracy 79.5-98.8%). We conclude that NMF can be used to analyse Raman data across different equipment configurations and the preclinical/clinical divide. Thus, the application of NMF decomposition methods could enhance the potential of Raman spectroscopy for the study of fatal neuromuscular diseases.


  • Open Access

    Rapid identification of human muscle disease with fibre optic Raman spectroscopy

    by James J. P. Alix, Maria Plesia, Gavin R. Lloyd, Alexander P. Dudgeon, Catherine A. Kendall, Channa Hewamadduma, Marios Hadjivassiliou, Christopher J. McDermott, Gráinne S. Gorman, Robert W. Taylor, et al.

    The diagnosis of muscle disorders (“myopathies”) can be challenging and new biomarkers of disease are required to enhance clinical practice and research. Despite advances in areas such as imaging and genomic medicine, muscle biopsy remains an important but time-consuming investigation. Raman spectroscopy is a vibrational spectroscopy application that could provide a rapid analysis of muscle tissue, as it requires no sample preparation and is simple to perform. Here, we investigated the feasibility of using a miniaturised, portable fibre optic Raman system for the rapid identification of muscle disease. Samples were assessed from 27 patients with a final clinico-pathological diagnosis of a myopathy and 17 patients in whom investigations and clinical follow-up excluded myopathy. Multivariate classification techniques achieved accuracies ranging between 71–77%. To explore the potential of Raman spectroscopy to identify different myopathies, patients were subdivided into mitochondrial and non-mitochondrial myopathy groups. Classification accuracies were between 74–89%. Observed spectral changes were related to changes in protein structure. These data indicate fibre optic Raman spectroscopy is a promising technique for the rapid identification of muscle disease that could provide real time diagnostic information. The application of fibre optic Raman technology raises the prospect of in vivo bedside testing for muscle diseases which would significantly streamline the diagnostic pathway of these disorders.


  • The application of Raman spectroscopy to the diagnosis of mitochondrial muscle disease: A preliminary comparison between fibre optic probe and microscope formats

    by James J. P. Alix, Maria Plesia, Gavin R. Lloyd, Alexander P. Dudgeon, Catherine A. Kendall, Christopher J. McDermott, Gráinne S. Gorman, Robert W. Taylor, Pamela J. Shaw, John C. Day


  • Open Access

    Hyperspectral imaging as a tool for assessing coral health utilising natural fluorescence

    by Jonathan Teague, Jack Willans, Michael J. Allen, Thomas B. Scott, John C.C. Day

    Fluorescent proteins are a crucial visualisation tool in a myriad of research fields including cell biology, microbiology and medicine. Fluorescence is a result of the absorption of electromagnetic radiation at one wavelength and its reemission at a longer wavelength. Coral communities exhibit a natural fluorescence which can be used to distinguish between diseased and healthy specimens, however, current methods, such as the underwater visual census, are expensive and time-consuming constituting many manned dive hours. We propose the use of a remotely operated vehicle mounted with a novel hyperspectral fluorescence imaging (HyFI) “payload” for more rapid surveying and data collection. We have tested our system in a laboratory environment on common coral species including Seriatopora spp., Montipora verrucosa, Montipora spp., Montipora capricornis, Echinopora lamellose, Euphyllia ancora, Pocillopora damicornis and Montipora confusa. With the aid of hyperspectral imaging, the coral specimens’ emission wavelengths can be accurately assessed by capturing the emission spectra of the corals when excited with light emitting diodes (395–405 and 440 nm). Fluorescence can also provide an indicator of coral bleaching as shown in our bleaching experiment where we observe fluorescence reduction alongside coral bleaching.


  • Open Access

    ‘Hi-Fi AFM’: high-speed contact mode atomic force microscopy with optical pickups

    by Freddie S Russell-Pavier, Loren Picco, John C C Day, Namid Ram Shatil, Andrew Yacoot, Oliver David Payton

    High-speed atomic force microscopy (HS-AFM) is a powerful emerging technique used to gain insight into real-time nanoscale dynamics and phenomena across the sciences. By performing measurements of material properties, abundancy counting and dimensional analysis, it enables a new generation of discoveries at the atomic scale. Here, we demonstrate the use of an optical pickup unit (OPU) typically found in PCs, hi-fis and games consoles worldwide, as a vertical detection system within in a HS-AFM operated in contact mode. The OPU displacement performance is compared to that of a commercially available laser Doppler vibrometer with ±15 pm resolution. Sub-nanometre sensitivity is achieved with an OPU, presented via the identification of two resonant modes of a cantilever stimulated by ambient thermal excitation. To demonstrate the large dynamic range of the sensor at fast scan-speeds, surface profiles with step heights in excess of 100 nm and surface textures less than 10 nm were collected using a custom OPU-based HS-AFM. The high-fidelity measurements are extended to visible length scales in short timescales by imaging areas of up to 200 µ m 2 area at a pixel rate of 2 megapixels s −1 , tip velocity of 10 mm s −1 and area rate of 25 µ m 2 s −1 .


  • Open Access

    Miniature standoff Raman probe for neurosurgical applications

    by Oliver A. C. Stevens, Joanne Hutchings, William Gray, Rosa Louise Vincent, John C. Day

    Removal of intrinsic brain tumors is a delicate process, where a high degree of specificity is required to remove all of the tumor tissue without damaging healthy brain. The accuracy of this process can be greatly enhanced by intraoperative guidance. Optical biopsies using Raman spectroscopy are a minimally invasive and lower-cost alternative to current guidance methods. A miniature Raman probe for performing optical biopsies of human brain tissue is presented. The probe allows sampling inside a conventional stereotactic brain biopsy system: a needle of length 200 mm and inner diameter of 1.8 mm. By employing a miniature stand-off Raman design, the probe removes the need for any additional components to be inserted into the brain. Additionally, the probe achieves a very low internal silica background while maintaining good collection of Raman signal. To illustrate this, the probe is compared with a Raman probe that uses a pair of optical fibers for collection. The miniature stand-off Raman probe is shown to collect a comparable number of Raman scattered photons, but the Raman signal to background ratio is improved by a factor of five at Raman shifts below ∼500  cm−1. The probe’s suitability for use on tissue is demonstrated by discriminating between different types of healthy porcine brain tissue.