AFAndrea Ferrero

Andrea Ferrero

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrea Ferrero has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photon counting detector CTA for prostate arterial evaluation during the workup for prostate artery embolization

    by Forrest Linch, Prabhakar Rajiah, Michael Jundt, Alison Bashier, Kevin Wymer, Meghan Cooper, Derek Lomas, Andrea Ferrero, Christopher Favazza, Thomas Foley, et al.

    Purpose To evaluate small field of view (FOV) ultra-high spatial resolution pelvic photon-counting detector prostate CT angiograms (UHR PCD CTA) for identifying prostate arterial anatomy and extraprostatic anastomoses in patients undergoing workup for prostate artery embolization (PAE). Methods IRB-approved retrospective imaging and electronic medical record review of men who consecutively underwent UHR PCD CTA for PAE workup at our institution from 8/1/2022 to 12/1/2024. UHR PCD CTAs were evaluated by two vascular and interventional radiologists for main and accessory candidate prostatic arteries (PA/s) and anastomoses to penile, bladder, or rectal arteries. A main PA was defined as supplying the central gland and an accessory PA was defined as supplying the peripheral zone. PAs were categorized using the Carnevale classification. In patients who proceeded to PAE, digital subtraction angiograms (DSA) were retrospectively compared with UHR PCD CTA findings. Results UHR PCD CTA was obtained prior to PAE consultation for 50 men. We evaluated 100 pelvic sides, identifying 180 candidate PAs with a median of 3 candidate PAs per patient (mean, 3.6; range, 2–7). Overall, 56% (101/180) of candidate PAs were main and 44% (79/180) were accessory. Abridged Carnevale classifications: Type 5–21% (38/180). Eight accessory candidate PAs arose from the superior rectal artery. At least one candidate anastomosis arose from 40% (72/180) of candidate PAs. Of 95 total candidate anastomoses, 69 were extraprostatic (30 rectal, 20 bladder, 19 penile) and 26 were intraprostatic collaterals; 56% (53/95) arose from accessory and 44% (42/95) from main candidate PAs. Twenty-eight of 50 (56%) men underwent PAE, during which 72% (74/103) of available candidate PAs were selected, and prostatic supply was confirmed by DSA in 100% (74/74) of selected vessels. Conclusion Small FOV UHR PCD CTA is useful in identifying candidate PA supply, as well as potential extraprostatic anastomoses, providing an arterial roadmap for PAE planning. Candidate PA supply was confirmed by DSA in all selected vessels among patients who proceeded to PAE.

  • Improved display and detection of small renal stones using photon-counting detector CT compared to conventional energy-integrating detector CT

    by Andrea Esquivel, Theodora Potretzke, Andrea Ferrero, Akitoshi Inoue, Safa Hoodeshenans, Achille Mileto, Timothy Winfree, Mariana Yalon, Ashish Khandelwal, Kishore Rajendran, et al.

    Purpose To compare same-day photon-counting detector CT (PCD-CT) to conventional energy-integrating detector CT (EID-CT) for detection of small renal stones (≤ 3 mm). Methods Patients undergoing clinical dual-energy EID-CT for known or suspected stone disease underwent same-day research PCD-CT. Patients with greater than 10 stones and no visible stones under 3 mm were excluded. Three radiologists selected the optimal reconstruction configuration for each CT modality and created the reference standard for renal stone presence. Two other radiologists, blinded to imaging modality, independently reviewed anonymized images to detect renal stones, rating confidence in potential stones using a Likert scale (1 = Definitely present, 2 = Probably present, 3 = Questionably present, 4 = Not seen). Sensitivity and false positive detections for PCD and EID-CT were calculated. Results Twenty-one patients underwent clinical EID-CT followed by same-day PCD-CT, with the reference standard identifying 121 renal stones (mean size 2.8 ± 2.6 mm). 0.4-mm PCD-CT images were more likely to display a stone as definitely present compared to 1- or 2-mm EID-CT images (p < 0.0001). Overall sensitivity for detection of all stones was greater at PCD-CT (0.75 vs. 0.55, p < 0.05). Pooled sensitivity of stones \(\le\) 3 mm was also significantly higher at PCD-CT (0.67 vs. 0.41, p < 0.05), with false positive detections differing between readers and modalities (PCD-CT vs. EID-CT: R1—7 v. 5; R2 – 7 v. 1). Conclusion Sensitivity for renal stones was significantly higher using high spatial resolution PCD-CT vs. EID-CT, especially for stones 3 mm or less in size, which may be important for at-risk patient populations. Prospective evaluation in larger patient populations that will benefit from detection of small stones is warranted. Graphical abstract


  • A Generalizable Framework for Kidney Stone Composition Characterization Using Dual-Energy CT

    by Picha Shunhavanich, Andrea Ferrero, Cynthia H. McCollough, Scott S. Hsieh


  • In Vivo Prediction of Kidney Stone Fragility Using Radiomics-Based Regression Models

    by Parvathy Sudhir Pillai, Scott S. Hsieh, Andrew J. Vercnocke, Aaron M. Potretzke, Kevin Koo, Cynthia H. McCollough, Andrea Ferrero

    Introduction: The surgical technique for urinary stone removal is partly influenced by its fragility, as prognosticated by the clinician. This feasibility study aims to develop a linear regression model from CT-based radiomic markers to predict kidney stone comminution time in vivo with two ultrasonic lithotrites. Materials and Methods: Patients identified by urologists at our institution as eligible candidates for percutaneous nephrolithotomy were prospectively enrolled. The active engagement time of the lithotrite in breaking the stone during surgery denoted the comminution time of each stone. The comminution rate was computed as the stone volume disintegrated per minute. Stones were grouped into three fragility classes (fragile, moderate, hard), based on inverse of the comminution rates with respect to the mean. Multivariable linear regression models were trained with radiomic features extracted from clinical CT images to predict comminution times in vivo . The model with the least root mean squared error (RMSE) on comminution times and the fewest misclassification of fragility was finally selected. Results: Twenty-eight patients with 31 stones in total were included in this study. Stones in the cohort averaged 1557 (±2472) mm 3 in volume and 5.3 (±7.4) minutes in comminution time. Ten stones had nonmoderate fragility. Linear regression of stone volume alone predicted comminution time with an RMSE of 6.8 minutes and missed all 10 stones with nonmoderate fragility. A fragility model that included stone volume, internal morphology, shape-based radiomics, and device type improved RMSE to below 3.3 minutes and correctly classified 20/21 moderate and 6/10 nonmoderate stones. Conclusions: CT metrics-based fragility models may provide information to surgeons regarding kidney stone fragility and facilitate the selection of stone removal procedures.


  • Top Cited Papers
    Open Access

    Photon-Counting Detector CT: Key Points Radiologists Should Know

    by Andrea Esquivel, Andrea Ferrero, Achille Mileto, Francis Baffour, Kelly Horst, Prabhakar Shantha Rajiah, Akitoshi Inoue, Shuai Leng, Cynthia McCollough, Joel G. Fletcher

    Esquivel A, et al. Korean J Radiol. 2022 Aug;23:e57. https://doi.org/10.3348/kjr.2022.0377


  • Open Access

    Framework of metal insertion in the projection domain for image quality optimization in interventional computed tomography

    by Liqiang Ren, Andrea Ferrero, Christopher P. Favazza

    Percutaneous ablation has achieved broad clinical applications in locally treating metastatic lesions over the past decade.1 In part due to wide availability and excellent ability to delineate tumors from surrounding materials, computed tomography (CT) image guidance is routinely relied upon for treatment planning, intraprocedural guidance and monitoring, and post-treatment assessment of interventional oncology (IO) procedures.2,3 One drawback of CT imaging during these ablation procedures, however, is the potentially severe artifacts introduced by the metallic probes and devices used for treatment. These metal artifacts degrade the image quality in the anatomical region of interest (ROI). As a result, the interventional radiologist’s confidence in placement accuracy of the probe(s) relative to the tumor and sensitive tissues may be substantially reduced.4,5 Additionally, probe-induced artifacts may limit treatment zone evaluation during treatment monitoring. The artifacts generated by these probes vary greatly with their type, number, and relative orientation. As a result, CT protocol optimization for interventional procedures has been shown to be challenging and complex.5


  • Automated radiomic analysis of CT images to predict likelihood of spontaneous passage of symptomatic renal stones

    by Payam Mohammadinejad, Andrea Ferrero, David J. Bartlett, Ashish Khandelwal, Roy Marcus, John C. Lieske, Taylor R. Moen, Kristin C. Mara, Felicity T. Enders, Cynthia H. McCollough, et al.

    Purpose To evaluate the ability of a semi-automated radiomic analysis software in predicting the likelihood of spontaneous passage of urinary stones compared with manual measurements. Methods Symptomatic patients visiting the emergency department with suspected stones in either kidney or ureters who underwent a CT scan were included. Patients were followed for up to 6 months for the outcome of a trial of passage. Maximum stone diameters in axial and coronal images were measured manually. Stone length, width, height, max diameter, volume, the mean and standard deviation of the Hounsfield units, and morphologic features were also measured using automated radiomic analysis software. Multivariate models were developed using these data to predict subsequent spontaneous stone passage, with results expressed as the area under a receiver operating curve (AUC). Results One hundred eighty-four patients (69 females) with a median age of 56 years were included. Spontaneous stone passage occurred in 114 patients (62%). Univariate analysis demonstrated an AUC of 0.83 and 0.82 for the maximum stone diameter determined manually in the axial and coronal planes, respectively. Multivariate models demonstrated an AUC of 0.82 for a model including manual measurement of maximum stone diameter in axial and coronal planes. The same AUC was found for a model including automatic measurement of maximum height and diameter of the stone. Further addition of morphological parameters measured automatically did not increase AUC beyond 0.83. Conclusion The semi-automated radiomic analysis of urinary stones shows similar accuracy compared with manual measurements for predicting urinary stone passage. Further studies are needed to predict clinical impacts of reporting the likelihood of urinary stone passage and improving inter-observer variation using automatic radiomic analysis software.


  • Concern about a recently published paper in the European Journal of Radiology

    by Cynthia H. McCollough, Shuai Leng, Lifeng Yu, Andrea Ferrero

  • Characterization of Urinary Stone Composition by Use of Whole-body, Photon-counting Detector CT

    by Andrea Ferrero, Ralf Gutjahr, Ahmed F. Halaweish, Shuai Leng, Cynthia H. McCollough


  • Quantitative Prediction of Stone Fragility From Routine Dual Energy CT

    by Andrea Ferrero, Juan C. Montoya, Lisa E. Vaughan, Alice E. Huang, Ian O. McKeag, Felicity T. Enders, James C. Williams, Cynthia H. McCollough