Yi-Sheng Chan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi-Sheng Chan has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alvin Chao-Yu Chen
Bone and Joint Research Center, Department of Orthopedic Surgery, Chang Gung Memorial Hospital-Linkou & University College of Medicine, Taoyuan City, Taiwan
6 shared publications - Chih-Hao Chiu
Department of Orthopedic Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan
5 shared publications - Chun-Ying Cheng
Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Chang Gung University, Taoyuan, Taiwan
3 shared publications - Kuo-Yao Hsu
Department of Orthopaedic Surgery, Chang Gung Memorial Hospital Linkou Branch, Taoyuan, Taiwan (ROC); Bone and Joint Research Center, Chang Gung Memorial Hospital Linkou Branch, Taoyuan, Taiwan (ROC)
2 shared publications - Cheng-Pang Yang
Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou and University College of Medicine, 5th, Fu-Shin Street, Kweishan Dist, Taoyuan, 333, Taiwan, Republic of China
1 shared publication - Chun-Jui Weng
Bone and Joint Research Center, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital–Linkou and Chang Gung University College of Medicine, 5th, Fu-Shin Street, Kweishan District, Taoyuan, 333, Taiwan, ROC
1 shared publication
Latest Publications
- Open Access
- 7 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3488
Long-Term Outcomes of Radial Head Arthroplasty in Complex Elbow Fracture Dislocation
The purpose of the current study was to investigate the long-term outcomes of radial head arthroplasty in complex elbow injuries through radiographic analysis and functional correlation. We evaluated 24 radial head arthroplasties in 24 consecutive patients with complex elbow fracture dislocation. All patients were treated with a single type of modular monopolar prosthesis containing smooth stem in press-fit implantation. Clinical survey using the Mayo Elbow Performance Score (MEPS), self-reported scales of shortened Disabilities of the Arm, Shoulder, and Hand (QuickDASH) and the visual analog scale (VAS) at more than 10-year follow-up were reported and compared to 2-year outcomes. Periprosthetic osteolysis was measured in the 10 zones of prosthesis-cortical interface with a modified radiolucency score, which was calibrated by each prosthesis size. Pearson correlation analysis was performed to detect the association between periprosthetic radiolucency and clinical assessment. At the final follow-up, MEPS, QuickDASH score and VAS score averaged 82.5 ± 15, 14.1 ± 14.3 and 1.6 ± 1.2 respectively. A decline in functional status was noted, with decreased mean MEPS and increased mean QuickDASH and VAS scores as compared to the 2-year results while the difference was insignificant. Periprosthetic osteolysis was more prevalent around stem tip of zone 3 and zone 8. The final and 2-year radiolucency scores averaged 7.4 ± 4.2 and 2.6 ± 2.3 respectively with significant difference. Pearson correlation analysis indicated that the difference between radiolucency scores and clinical outcomes in MEPS/QuickDASH/VAS was −0.836, 0.517 and 0.464. Progression of periprosthetic osteolysis after postoperative 10 years is more prevalent around the stem tip with moderate to high correlation to clinical outcomes. Sustained follow-up is warranted to justify subsequent surgery for revision or implant removal.
- 7 August 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (16) , 3488
Open AccessLong-Term Outcomes of Radial Head Arthroplasty in Complex Elbow Fracture Dislocation
The purpose of the current study was to investigate the long-term outcomes of radial head arthroplasty in complex elbow injuries through radiographic analysis and functional correlation. We evaluated 24 radial head arthroplasties in 24 consecutive patients with complex elbow fracture dislocation. All patients were treated with a single type of modular monopolar prosthesis containing smooth stem in press-fit implantation. Clinical survey using the Mayo Elbow Performance Score (MEPS), self-reported scales of shortened Disabilities of the Arm, Shoulder, and Hand (QuickDASH) and the visual analog scale (VAS) at more than 10-year follow-up were reported and compared to 2-year outcomes. Periprosthetic osteolysis was measured in the 10 zones of prosthesis-cortical interface with a modified radiolucency score, which was calibrated by each prosthesis size. Pearson correlation analysis was performed to detect the association between periprosthetic radiolucency and clinical assessment. At the final follow-up, MEPS, QuickDASH score and VAS score averaged 82.5 ± 15, 14.1 ± 14.3 and 1.6 ± 1.2 respectively. A decline in functional status was noted, with decreased mean MEPS and increased mean QuickDASH and VAS scores as compared to the 2-year results while the difference was insignificant. Periprosthetic osteolysis was more prevalent around stem tip of zone 3 and zone 8. The final and 2-year radiolucency scores averaged 7.4 ± 4.2 and 2.6 ± 2.3 respectively with significant difference. Pearson correlation analysis indicated that the difference between radiolucency scores and clinical outcomes in MEPS/QuickDASH/VAS was −0.836, 0.517 and 0.464. Progression of periprosthetic osteolysis after postoperative 10 years is more prevalent around the stem tip with moderate to high correlation to clinical outcomes. Sustained follow-up is warranted to justify subsequent surgery for revision or implant removal.
- Open Access
- 24 March 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1) , 1-7
All-arthroscopic repair of Atzei class II and III triangular fibrocartilage complex tears using the FasT-Fix suture device
Background: The study is aimed to propose an arthroscopic repair technique using a pre-tied suture device for peripheral TFCC (triangular fibrocartilage complex) tear with proximal component involvement. Methods: Through a retrospective review in the medical records of patients who underwent unilateral arthroscopic repair for TFCC Palmer IB lesion between 2017 and 2019, 12 patients were arthroscopically diagnosed as proximal component tear and received more than 1 year follow-up postoperatively. The arthroscope was introduced from 6R portal to discriminate Atzei class II from III lesions by a “visualization test” and to supervise the repair procedure using pre-tied FasT-Fix suture device from 3-4 portal. Two poly-ether-ether-ketone (PEEK) blocks were further advanced along the device needle to finally seat outside the ulnar joint capsule, followed by gradually tightening the pre-tied suture loop until the TFCC periphery was securely repositioned and held stably. Results: Operation time averaged 87 min. Hook test and DRUJ arthroscopy confirmed proximal component tear in all 12 wrists. Four patients were diagnosed to be Atzei class II lesion as full thickness tear of distal component was arthroscopically identified from 6R portal while the other 8 exhibited partial thickness tear and were categorized as class III lesion. Follow-up averaged 15 months with a range of 12 to 24 months. Mayo modified wrist score improved from an average of 61.3 preoperatively to 90.4 at the latest visit. Conclusions: A modified technique for diagnosis and all-arthroscopic repair in TFCC Atzei class II and III lesions using a pre-tied suture device is a feasible and safe option with promising results.
- 24 March 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1) , 1-7
Open AccessAll-arthroscopic repair of Atzei class II and III triangular fibrocartilage complex tears using the FasT-Fix suture device
Background: The study is aimed to propose an arthroscopic repair technique using a pre-tied suture device for peripheral TFCC (triangular fibrocartilage complex) tear with proximal component involvement. Methods: Through a retrospective review in the medical records of patients who underwent unilateral arthroscopic repair for TFCC Palmer IB lesion between 2017 and 2019, 12 patients were arthroscopically diagnosed as proximal component tear and received more than 1 year follow-up postoperatively. The arthroscope was introduced from 6R portal to discriminate Atzei class II from III lesions by a “visualization test” and to supervise the repair procedure using pre-tied FasT-Fix suture device from 3-4 portal. Two poly-ether-ether-ketone (PEEK) blocks were further advanced along the device needle to finally seat outside the ulnar joint capsule, followed by gradually tightening the pre-tied suture loop until the TFCC periphery was securely repositioned and held stably. Results: Operation time averaged 87 min. Hook test and DRUJ arthroscopy confirmed proximal component tear in all 12 wrists. Four patients were diagnosed to be Atzei class II lesion as full thickness tear of distal component was arthroscopically identified from 6R portal while the other 8 exhibited partial thickness tear and were categorized as class III lesion. Follow-up averaged 15 months with a range of 12 to 24 months. Mayo modified wrist score improved from an average of 61.3 preoperatively to 90.4 at the latest visit. Conclusions: A modified technique for diagnosis and all-arthroscopic repair in TFCC Atzei class II and III lesions using a pre-tied suture device is a feasible and safe option with promising results.
- Open Access
- 20 November 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-7
Retrospective cohort study on radial head arthroplasty comparing long-term outcomes between valgus type injury and fracture dislocation
Background: Radial head arthroplasty (RHA) has been commonly adopted for irreparable radial head fractures while little information is addressed on valgus type injury. The purpose of this study is to report long-term outcomes and radiographic analysis in RHA for valgus type injury with comparison to fracture dislocation injury. Methods: A retrospective cohort study was conducted in patients receiving unilateral RHA with loose-fit, modular metal prosthesis for irreparable radial head fractures between 2004 and 2012. Totally, 33 patients with a mean follow up of 9 years (range, 7 to 15 years) were enrolled and divided into two groups including 14 valgus injuries and 19 fracture-dislocations. Demographics of the patients, injury details, clinical and radiographic outcomes, and correlation analysis were investigated and compared between two groups. Results: In patient demographics, significant difference was noted in sex distribution (p = 0.001), lateral collateral ligament involvement (p = 0.000) and time from injury to RHA (p = 0.031) between two groups. No patient underwent subsequent removal or revision of prosthesis. Good to excellent results according to Mayo Elbow Performance Score (MEPS) was achieved in 13 and 14 patients in group A and B respectively. Final motion range and Disabilities of the Arm, Shoulder, and Hand score was significantly better in valgus injury group. Radiographic analysis demonstrated fewer patients in valgus injury group presented periprosthetic osteolysis with weak to moderate negative correlation between radiolucency score and MEPS. Conclusions: With an average of 9 years follow-up, RHA using loose-fit, modular metal prosthesis achieves encouraging outcomes for both valgus injury and fracture dislocation. In valgus type injury, better motion range, lower disability score and lower incidence of periprosthetic osteolysis is noted while correlation analysis of radiolucency score suggests extended, long-term investigation.
- 20 November 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-7
Open AccessRetrospective cohort study on radial head arthroplasty comparing long-term outcomes between valgus type injury and fracture dislocation
Background: Radial head arthroplasty (RHA) has been commonly adopted for irreparable radial head fractures while little information is addressed on valgus type injury. The purpose of this study is to report long-term outcomes and radiographic analysis in RHA for valgus type injury with comparison to fracture dislocation injury. Methods: A retrospective cohort study was conducted in patients receiving unilateral RHA with loose-fit, modular metal prosthesis for irreparable radial head fractures between 2004 and 2012. Totally, 33 patients with a mean follow up of 9 years (range, 7 to 15 years) were enrolled and divided into two groups including 14 valgus injuries and 19 fracture-dislocations. Demographics of the patients, injury details, clinical and radiographic outcomes, and correlation analysis were investigated and compared between two groups. Results: In patient demographics, significant difference was noted in sex distribution (p = 0.001), lateral collateral ligament involvement (p = 0.000) and time from injury to RHA (p = 0.031) between two groups. No patient underwent subsequent removal or revision of prosthesis. Good to excellent results according to Mayo Elbow Performance Score (MEPS) was achieved in 13 and 14 patients in group A and B respectively. Final motion range and Disabilities of the Arm, Shoulder, and Hand score was significantly better in valgus injury group. Radiographic analysis demonstrated fewer patients in valgus injury group presented periprosthetic osteolysis with weak to moderate negative correlation between radiolucency score and MEPS. Conclusions: With an average of 9 years follow-up, RHA using loose-fit, modular metal prosthesis achieves encouraging outcomes for both valgus injury and fracture dislocation. In valgus type injury, better motion range, lower disability score and lower incidence of periprosthetic osteolysis is noted while correlation analysis of radiolucency score suggests extended, long-term investigation.
- Open Access
- 26 July 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 1-10
Real-time detection of antibiotics cytotoxicity in rabbit periosteal cells using microfluidic devices with comparison to conventional culture assays
Local antibiotic application has been widely used in orthopedic surgery. The dose-related toxicity of antibiotics towards periosteal tissues and resulting effects on osteogenic expression are yet to be studied. Periosteal cells harvested from the medial tibia of New Zealand White rabbits were used. A seeding density of 5 × 103 cells/cm2 was determined to be optimal for testing in the pilot study; the cells were cultured in xCELLigence 96-well plates. Microfluidic impedance analyzers were used to monitor cellular proliferation in microfluidic culture systems with exposure to three different concentrations (10 μg/mL, 100 μg/mL, and 1000 μg/mL) of cefazolin, ciprofloxacin, and vancomycin, respectively. The correlation of cell index at day 7 with optical density values from WST-1 assays using conventional cultures was evaluated by calculating the Pearson’s coefficient. RNA analysis was performed to investigate the expression of osteogenic markers in the cultured cells, including core-binding factor alpha 1 (Cbfa1), osteopontin (OPN), and osteopontin promoter (OPNp), relative to glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as the endogenous control. A significant dose-related inhibition of cell index was found for all the 3 antibiotics, whereas the WST-1 assays showed a significant dose-related inhibition of cellular proliferation only at a high dose of cefazolin (1000 μg/mL) and medium-to-high dose of ciprofloxacin (100 μg/mL and 1000 μg/mL). Pearson’s coefficient analysis indicated a high correlation between the cell index and optical density values of WST-1 assays only for medium and high doses of ciprofloxacin (100 μg/mL and 1000 μg/mL); a moderate correlation was seen for cefazolin, and a low dose of ciprofloxacin (10 μg/mL). RNA analysis confirmed significant dose-related inhibition of cfba1, OPN, and OPNp expression by all three antibiotics. With optimal seeding amounts, rabbit periosteal cells can be dynamically monitored in the xCELLigence microfluidic system. Dose-related inhibition of cellular proliferation and osteogenic expression was found after exposure to cefazolin and ciprofloxacin. By providing real-time detection and exhibiting comparable correlation, microfluidic impedance-based analyzer is a feasible alternative to the conventional WST-1 assays.
- 26 July 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 1-10
Open AccessReal-time detection of antibiotics cytotoxicity in rabbit periosteal cells using microfluidic devices with comparison to conventional culture assays
Local antibiotic application has been widely used in orthopedic surgery. The dose-related toxicity of antibiotics towards periosteal tissues and resulting effects on osteogenic expression are yet to be studied. Periosteal cells harvested from the medial tibia of New Zealand White rabbits were used. A seeding density of 5 × 103 cells/cm2 was determined to be optimal for testing in the pilot study; the cells were cultured in xCELLigence 96-well plates. Microfluidic impedance analyzers were used to monitor cellular proliferation in microfluidic culture systems with exposure to three different concentrations (10 μg/mL, 100 μg/mL, and 1000 μg/mL) of cefazolin, ciprofloxacin, and vancomycin, respectively. The correlation of cell index at day 7 with optical density values from WST-1 assays using conventional cultures was evaluated by calculating the Pearson’s coefficient. RNA analysis was performed to investigate the expression of osteogenic markers in the cultured cells, including core-binding factor alpha 1 (Cbfa1), osteopontin (OPN), and osteopontin promoter (OPNp), relative to glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as the endogenous control. A significant dose-related inhibition of cell index was found for all the 3 antibiotics, whereas the WST-1 assays showed a significant dose-related inhibition of cellular proliferation only at a high dose of cefazolin (1000 μg/mL) and medium-to-high dose of ciprofloxacin (100 μg/mL and 1000 μg/mL). Pearson’s coefficient analysis indicated a high correlation between the cell index and optical density values of WST-1 assays only for medium and high doses of ciprofloxacin (100 μg/mL and 1000 μg/mL); a moderate correlation was seen for cefazolin, and a low dose of ciprofloxacin (10 μg/mL). RNA analysis confirmed significant dose-related inhibition of cfba1, OPN, and OPNp expression by all three antibiotics. With optimal seeding amounts, rabbit periosteal cells can be dynamically monitored in the xCELLigence microfluidic system. Dose-related inhibition of cellular proliferation and osteogenic expression was found after exposure to cefazolin and ciprofloxacin. By providing real-time detection and exhibiting comparable correlation, microfluidic impedance-based analyzer is a feasible alternative to the conventional WST-1 assays.
- Open Access
- 13 February 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 35
Mid-term survivorship of cruciate-retaining versus posterior-stabilized total knee arthroplasty using modular mini-keel tibial implants
Reports of diverse outcomes in modular mini-keel tibial componentry for total knee arthroplasty (TKA) have raised concerns about early aseptic loosening. Cruciate-retaining (CR) prostheses, using mini-keel implants, have yet to be reported and compared to posterior-stabilizing (PS) designs. A retrospective, case-matched study of 91 consecutive TKAs (n = 46 CR; n = 45 PS prostheses), using modular mini-keel tibial componentry with a 45-mm drop down stem extension, was conducted. The Knee Society Score functional survey, radiographic analysis including alignment and periprosthetic radiolucency, TKA prosthesis longevity, and surgical complications were reported and compared between CR and PS groups. The Knee Society Score at 5-year follow-up averaged 81.67 ± 11.97 and 80.12 ± 14.16 in the CR and PS groups, respectively (p = 0.29). The femorotibial angle averaged 5.85° ± 2.62° and 5.85° ± 3.27° valgus in the CR and PS groups, respectively (p = 0.60). The average tibial component angle was 0.46° ± 1.6° and 0.61° ± 1.3° varus in the CR and PS groups, respectively (p = 0.30); posterior inclination averaged 2.28° ± 2.36° and 1.93° ± 2.72° in the CR and PS groups, respectively (p = 0.51). Radiolucency was noted in 17 zones of the CR group and in 9 zones of the PS group (p = 0.24). Three TKAs required further surgery: one locking plate fixation for a periprosthetic tibial fracture (PS group) and two revision TKAs (one CR infection and one PS fracture). Modular mini-keel tibial components showed good reliability and results with both CR and PS prostheses in minimally invasive surgery TKA.
- 13 February 2018
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 13 (1) , 35
Open AccessMid-term survivorship of cruciate-retaining versus posterior-stabilized total knee arthroplasty using modular mini-keel tibial implants
Reports of diverse outcomes in modular mini-keel tibial componentry for total knee arthroplasty (TKA) have raised concerns about early aseptic loosening. Cruciate-retaining (CR) prostheses, using mini-keel implants, have yet to be reported and compared to posterior-stabilizing (PS) designs. A retrospective, case-matched study of 91 consecutive TKAs (n = 46 CR; n = 45 PS prostheses), using modular mini-keel tibial componentry with a 45-mm drop down stem extension, was conducted. The Knee Society Score functional survey, radiographic analysis including alignment and periprosthetic radiolucency, TKA prosthesis longevity, and surgical complications were reported and compared between CR and PS groups. The Knee Society Score at 5-year follow-up averaged 81.67 ± 11.97 and 80.12 ± 14.16 in the CR and PS groups, respectively (p = 0.29). The femorotibial angle averaged 5.85° ± 2.62° and 5.85° ± 3.27° valgus in the CR and PS groups, respectively (p = 0.60). The average tibial component angle was 0.46° ± 1.6° and 0.61° ± 1.3° varus in the CR and PS groups, respectively (p = 0.30); posterior inclination averaged 2.28° ± 2.36° and 1.93° ± 2.72° in the CR and PS groups, respectively (p = 0.51). Radiolucency was noted in 17 zones of the CR group and in 9 zones of the PS group (p = 0.24). Three TKAs required further surgery: one locking plate fixation for a periprosthetic tibial fracture (PS group) and two revision TKAs (one CR infection and one PS fracture). Modular mini-keel tibial components showed good reliability and results with both CR and PS prostheses in minimally invasive surgery TKA.
- Open Access
- 28 November 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 495
Influence of age, gender, and radiographic features on the deltoid splitting approach for surgical osteosynthesis in displaced proximal humerus fractures: a comparison study
The deltoid splitting approach has recently been widely adopted to facilitate less invasive procedures for proximal humerus fractures. However, there are still concerns regarding its effectiveness in aging people and in cases involving complex fractures. This study was conducted to evaluate the efficacy of a proximal humeral locking plate using the anterolateral deltoid splitting approach and to specifically examine the effect of patient age, gender, and fracture pattern on surgical outcomes. Forty-two cases of proximal humeral fractures treated using the deltoid splitting approach and locking plate fixation were reviewed. Outcome differences were evaluated in terms of age, gender distribution, and radiographic analysis based on the Neer Classification. The influence of the surgical approach was further investigated by age-matched paired analysis after subdividing patients into two age groups (younger than 60 years vs. older than 60 years; N = 21, in each group). In total, 41 patients (98%) demonstrated fracture union. The average Constant score was 80.4. No significant differences were found between patients younger than 60 years, and the older patients. Higher mean scores were found in men than in women (p = 0.448) and in simple fractures than in complex fractures (p = 0.454), without any significant differences. Better postoperative functional outcomes were observed when the humeral head–neck angle was greater than 105°, with a significant difference (p = 0.000). Surgical complications were found in 16 patients (38%) without significant difference between two age groups (p = 0.268). The most common complication was screw penetration. Anterolateral deltoid splitting using locking plate fixation provided a feasible alternative for surgery of proximal humerus fractures in different age groups and yielded comparable outcomes when the neck-shaft angle was properly restored. Surgeons must be cautious regarding potential complications, especially with screw penetration when using the locking plate through a less invasive approach. ISRCTN75494532 . Trial Date: 2017/01/31.
- 28 November 2017
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 18 (1) , 495
Open AccessInfluence of age, gender, and radiographic features on the deltoid splitting approach for surgical osteosynthesis in displaced proximal humerus fractures: a comparison study
The deltoid splitting approach has recently been widely adopted to facilitate less invasive procedures for proximal humerus fractures. However, there are still concerns regarding its effectiveness in aging people and in cases involving complex fractures. This study was conducted to evaluate the efficacy of a proximal humeral locking plate using the anterolateral deltoid splitting approach and to specifically examine the effect of patient age, gender, and fracture pattern on surgical outcomes. Forty-two cases of proximal humeral fractures treated using the deltoid splitting approach and locking plate fixation were reviewed. Outcome differences were evaluated in terms of age, gender distribution, and radiographic analysis based on the Neer Classification. The influence of the surgical approach was further investigated by age-matched paired analysis after subdividing patients into two age groups (younger than 60 years vs. older than 60 years; N = 21, in each group). In total, 41 patients (98%) demonstrated fracture union. The average Constant score was 80.4. No significant differences were found between patients younger than 60 years, and the older patients. Higher mean scores were found in men than in women (p = 0.448) and in simple fractures than in complex fractures (p = 0.454), without any significant differences. Better postoperative functional outcomes were observed when the humeral head–neck angle was greater than 105°, with a significant difference (p = 0.000). Surgical complications were found in 16 patients (38%) without significant difference between two age groups (p = 0.268). The most common complication was screw penetration. Anterolateral deltoid splitting using locking plate fixation provided a feasible alternative for surgery of proximal humerus fractures in different age groups and yielded comparable outcomes when the neck-shaft angle was properly restored. Surgeons must be cautious regarding potential complications, especially with screw penetration when using the locking plate through a less invasive approach. ISRCTN75494532 . Trial Date: 2017/01/31.