Magdalena Richter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Magdalena Richter has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Wiktoria Maria Suchorska
Department of Electroradiology, Poznan University of Medical Sciences, Garbary 15, 61-866 Poznan, Poland
7 shared publications - Michał Stefan Lach
Department of Orthopaedics and Traumatology, Poznan University of Medical Sciences, 28 Czerwca 1956r. 135/147 Street, 61-545, Poznan, Poland; Radiobiology Laboratory, Greater Poland Cancer Centre, Garbary 15 Street, 61-866, Poznan, Poland
5 shared publications - Katarzyna Kulcenty
Radiobiology Laboratory, Greater Poland Cancer Centre, Garbary 15 Street, 61-866 Poznan, Poland
3 shared publications - Monika Anna Rosochowicz
Doctoral School, Poznan University of Medical Sciences Poznan, Poland; Department of Orthopaedics and Traumatology, Poznan University of Medical Sciences, 28 Czerwca 1956r. 135/147 Street, 61-545, Poznan, Poland; Radiobiology Laboratory, Greater Poland Cancer Centre, Garbary 15 Street, 61-866, Poznan, Poland
3 shared publications - Tomasz Trzeciak
Department of Orthopedics and Traumatology, Poznan University of Medical Sciences, 61-545 Poznan, Poland
3 shared publications - Tomasz Trzeciak
Department of Orthopaedics and Traumatology, Poznan University of Medical Sciences, 28 Czerwca 1956r. 135/147 Street, 61-545, Poznan, Poland
3 shared publications
Latest Publications
- Open Access
- 15 July 2025
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 777, 152336
iPSC-conditioned medium mitigates the adverse effects of osteoarthritic synovial fluid on chondrocyte cultures
- 15 July 2025
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 777, 152336
Open AccessiPSC-conditioned medium mitigates the adverse effects of osteoarthritic synovial fluid on chondrocyte cultures
- Open Access
- 11 July 2024
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 730, 150392
The iPSC secretome is beneficial for in vitro propagation of primary osteoarthritic chondrocytes cell lines
- 11 July 2024
- Published by Elsevier in Biochemical and Biophysical Research Communications
- Vol. 730, 150392
Open AccessThe iPSC secretome is beneficial for in vitro propagation of primary osteoarthritic chondrocytes cell lines
- Open Access
- 12 February 2023
- Published by MDPI AG in Antioxidants
- Vol. 12 (2) , 464
Oxidative Stress in Long-Term Exposure to Multi-Walled Carbon Nanotubes in Male Rats
Multi-walled carbon nanotubes (MWCNTs) serve as nanoparticles due to their size, and for that reason, when in contact with the biological system, they can have toxic effects. One of the main mechanisms responsible for nanotoxicity is oxidative stress resulting from the production of intracellular reactive oxygen species (ROS). Therefore, oxidative stress biomarkers are important tools for assessing MWCNTs toxicity. The aim of this study was to evaluate the oxidative stress of multi-walled carbon nanotubes in male rats. Our animal model studies of MWCNTs (diameter ~15–30 nm, length ~15–20 μm) include measurement of oxidative stress parameters in the body fluid and tissues of animals after long-term exposure. Rattus Norvegicus/Wistar male rats were administrated a single injection to the knee joint at three concentrations: 0.03 mg/mL, 0.25 mg/mL, and 0.5 mg/mL. The rats were euthanized 12 and 18 months post-exposure by drawing blood from the heart, and their liver and kidney tissues were removed. To evaluate toxicity, the enzymatic activity of total protein (TP), reduced glutathione (GSH), glutathione S–transferase (GST), thiobarbituric acid reactive substances (TBARS), Trolox equivalent antioxidant capacity (TEAC), nitric oxide (NO), and catalase (CAT) was measured and histopathological examination was conducted. Results in rat livers showed that TEAC level was decreased in rats receiving nanotubes at higher concentrations. Results in kidneys report that the level of NO showed higher concentration after long exposure, and results in animal serums showed lower levels of GSH in rats exposed to nanotubes at higher concentrations. The 18-month exposure also resulted in a statistically significant increase in GST activity in the group of rats exposed to nanotubes at higher concentrations compared to animals receiving MWCNTs at lower concentrations and compared to the control group. Therefore, an analysis of oxidative stress parameters can be a key indicator of the toxic potential of multi-walled carbon nanotubes.
- 12 February 2023
- Published by MDPI AG in Antioxidants
- Vol. 12 (2) , 464
Open AccessOxidative Stress in Long-Term Exposure to Multi-Walled Carbon Nanotubes in Male Rats
Multi-walled carbon nanotubes (MWCNTs) serve as nanoparticles due to their size, and for that reason, when in contact with the biological system, they can have toxic effects. One of the main mechanisms responsible for nanotoxicity is oxidative stress resulting from the production of intracellular reactive oxygen species (ROS). Therefore, oxidative stress biomarkers are important tools for assessing MWCNTs toxicity. The aim of this study was to evaluate the oxidative stress of multi-walled carbon nanotubes in male rats. Our animal model studies of MWCNTs (diameter ~15–30 nm, length ~15–20 μm) include measurement of oxidative stress parameters in the body fluid and tissues of animals after long-term exposure. Rattus Norvegicus/Wistar male rats were administrated a single injection to the knee joint at three concentrations: 0.03 mg/mL, 0.25 mg/mL, and 0.5 mg/mL. The rats were euthanized 12 and 18 months post-exposure by drawing blood from the heart, and their liver and kidney tissues were removed. To evaluate toxicity, the enzymatic activity of total protein (TP), reduced glutathione (GSH), glutathione S–transferase (GST), thiobarbituric acid reactive substances (TBARS), Trolox equivalent antioxidant capacity (TEAC), nitric oxide (NO), and catalase (CAT) was measured and histopathological examination was conducted. Results in rat livers showed that TEAC level was decreased in rats receiving nanotubes at higher concentrations. Results in kidneys report that the level of NO showed higher concentration after long exposure, and results in animal serums showed lower levels of GSH in rats exposed to nanotubes at higher concentrations. The 18-month exposure also resulted in a statistically significant increase in GST activity in the group of rats exposed to nanotubes at higher concentrations compared to animals receiving MWCNTs at lower concentrations and compared to the control group. Therefore, an analysis of oxidative stress parameters can be a key indicator of the toxic potential of multi-walled carbon nanotubes.
- Open Access
- 30 May 2022
- Published by GSC Online Press in World Journal of Advanced Research and Reviews
- Vol. 14 (2) , 261-283
Metal ions release from metallic orthopedic implants exposed to tribocorrosion and electrochemical corrosion conditions in simulated body fluids: Clinical context and in vitro experimental investigations
The use of metallic biomaterials in the medical implant devices has become increasingly prevalent over the past few decades. Patients find themselves being exposed to metals in a variety of ways, ranging from external exposure to instruments such as medical devices to internal exposure via surgical devices being implanted in their bodies. Potential health risks are associated with metallic wear debris in the form of nanoparticles in situ generation and the release of in vitro metal ions into human biological specimen's circulation. In combination with mechanically accelerated electrochemical processes, this can lead to the release of toxic metal ions, nanoparticles or micro scaled debris in the surrounding tissues and body fluids bring about relevant health issues and contribute to implant loss of failure. Metal ions release from metallic materials; stainless steel, cobalt-chromium alloys, titanium and its alloys, and nickel-titanium alloys implanted into the human body in orthopedic surgery is becoming a major cause of concern. The degradation mechanisms of the metallic implants lead to implants failure and tissue inflammation. However, the levels of metallic ions in those fluids can vary depending on the involved degradation mechanism of the implant. After briefly recalling the clinical context, this article analyses the in vitro studies on metals and metallic alloys corrosion, tribocorrosion and electrochemical corrosion under simulated inflammation conditions. Specifically, the present review reported the results of in vitro experimental investigations on the release of metal ions from metallic orthopedic implant materials, subjected to different electrochemical corrosion and tribocorrosion conditions, into simulated human body fluids.
- 30 May 2022
- Published by GSC Online Press in World Journal of Advanced Research and Reviews
- Vol. 14 (2) , 261-283
Open AccessMetal ions release from metallic orthopedic implants exposed to tribocorrosion and electrochemical corrosion conditions in simulated body fluids: Clinical context and in vitro experimental investigations
The use of metallic biomaterials in the medical implant devices has become increasingly prevalent over the past few decades. Patients find themselves being exposed to metals in a variety of ways, ranging from external exposure to instruments such as medical devices to internal exposure via surgical devices being implanted in their bodies. Potential health risks are associated with metallic wear debris in the form of nanoparticles in situ generation and the release of in vitro metal ions into human biological specimen's circulation. In combination with mechanically accelerated electrochemical processes, this can lead to the release of toxic metal ions, nanoparticles or micro scaled debris in the surrounding tissues and body fluids bring about relevant health issues and contribute to implant loss of failure. Metal ions release from metallic materials; stainless steel, cobalt-chromium alloys, titanium and its alloys, and nickel-titanium alloys implanted into the human body in orthopedic surgery is becoming a major cause of concern. The degradation mechanisms of the metallic implants lead to implants failure and tissue inflammation. However, the levels of metallic ions in those fluids can vary depending on the involved degradation mechanism of the implant. After briefly recalling the clinical context, this article analyses the in vitro studies on metals and metallic alloys corrosion, tribocorrosion and electrochemical corrosion under simulated inflammation conditions. Specifically, the present review reported the results of in vitro experimental investigations on the release of metal ions from metallic orthopedic implant materials, subjected to different electrochemical corrosion and tribocorrosion conditions, into simulated human body fluids.
- Open Access
The Induced Pluripotent Stem Cells in Articular Cartilage Regeneration and Disease Modelling: Are We Ready for Their Clinical Use?
The development of induced pluripotent stem cells has brought unlimited possibilities to the field of regenerative medicine. This could be ideal for treating osteoarthritis and other skeletal diseases, because the current procedures tend to be short-term solutions. The usage of induced pluripotent stem cells in the cell-based regeneration of cartilage damages could replace or improve on the current techniques. The patient’s specific non-invasive collection of tissue for reprogramming purposes could also create a platform for drug screening and disease modelling for an overview of distinct skeletal abnormalities. In this review, we seek to summarise the latest achievements in the chondrogenic differentiation of pluripotent stem cells for regenerative purposes and disease modelling.
Open AccessThe Induced Pluripotent Stem Cells in Articular Cartilage Regeneration and Disease Modelling: Are We Ready for Their Clinical Use?
The development of induced pluripotent stem cells has brought unlimited possibilities to the field of regenerative medicine. This could be ideal for treating osteoarthritis and other skeletal diseases, because the current procedures tend to be short-term solutions. The usage of induced pluripotent stem cells in the cell-based regeneration of cartilage damages could replace or improve on the current techniques. The patient’s specific non-invasive collection of tissue for reprogramming purposes could also create a platform for drug screening and disease modelling for an overview of distinct skeletal abnormalities. In this review, we seek to summarise the latest achievements in the chondrogenic differentiation of pluripotent stem cells for regenerative purposes and disease modelling.
- Open Access
- 21 October 2021
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (3) , 549-553
Effect of continuous passive motion on the early recovery outcomes after total knee arthroplasty
Introduction: Continuous passive motion (CPM) is a frequently used method in the early post-operative rehabilitation of patients after knee surgery. In this study, the effectiveness of the CPM method was evaluated after primary total knee arthroplasty during an early recovery period. Methods: Eighty patients undergoing total knee arthroplasty were assigned into two groups. The experimental group received CPM and active exercises, while the control group active exercises only. All subjects were evaluated once before the surgery and at a discharge, in terms of mean active range of motion (AROM), mean Knee Society Score (KSS), and Western Ontario and MacMaster Universities Osteoarthritis Index (WOMAC). Results: The mean AROM for the experimental group was 82.3° ± 14.3° and 76.1° ± 22.2° for the control. The mean KSS score was 136.4 ± 19.3 points for the experimental group, and 135.7 ± 15.1 for the control. There were no statistical differences between the two groups. The KSS functional score was 66.4 ± 8.1 points for the experimental group compared to 62.2 ± 7.3 points for the control, but there was a statistically significant difference between the groups at discharge from the hospital (p = 0.009). A subjective estimation of the pain level, joint stiffness and function also showed a statistically significant difference between the two groups (38.6 ± 14.3 points for the CPM group and 21.2 ± 15.7 for the control). Conclusion: These findings show that there is no significant effect of CPM in terms of improving clinical measurements. However, there was a significant beneficial effect on the subjective assessment of pain level, joint stiffness, and functional ability.
- 21 October 2021
- Published by Springer Nature in International Orthopaedics
- Vol. 46 (3) , 549-553
Open AccessEffect of continuous passive motion on the early recovery outcomes after total knee arthroplasty
Introduction: Continuous passive motion (CPM) is a frequently used method in the early post-operative rehabilitation of patients after knee surgery. In this study, the effectiveness of the CPM method was evaluated after primary total knee arthroplasty during an early recovery period. Methods: Eighty patients undergoing total knee arthroplasty were assigned into two groups. The experimental group received CPM and active exercises, while the control group active exercises only. All subjects were evaluated once before the surgery and at a discharge, in terms of mean active range of motion (AROM), mean Knee Society Score (KSS), and Western Ontario and MacMaster Universities Osteoarthritis Index (WOMAC). Results: The mean AROM for the experimental group was 82.3° ± 14.3° and 76.1° ± 22.2° for the control. The mean KSS score was 136.4 ± 19.3 points for the experimental group, and 135.7 ± 15.1 for the control. There were no statistical differences between the two groups. The KSS functional score was 66.4 ± 8.1 points for the experimental group compared to 62.2 ± 7.3 points for the control, but there was a statistically significant difference between the groups at discharge from the hospital (p = 0.009). A subjective estimation of the pain level, joint stiffness and function also showed a statistically significant difference between the two groups (38.6 ± 14.3 points for the CPM group and 21.2 ± 15.7 for the control). Conclusion: These findings show that there is no significant effect of CPM in terms of improving clinical measurements. However, there was a significant beneficial effect on the subjective assessment of pain level, joint stiffness, and functional ability.
- Open Access
- 30 March 2021
- Published by GSC Online Press in World Journal of Advanced Research and Reviews
- Vol. 9 (3) , 167-187
Review of the local tissue reaction to metallic spinal implant debris: Ions and nanoparticles
Biologic reactivity to implant debris is the primary determinant of long-term clinical performance. The metallic implants placed in human bodies can exhibit electrochemical or mechanical corrosion that yields in the liberation of metallic products. Such implants-derived metal wear products can be present in the form of metal ions and particulate metal debris with still unknown effects on human health. In situ generation of metallic wear particles, corrosion products and in vivo trace metal ions release from metal and metallic alloys implanted into the body in spine surgery is becoming a major cause for concern regarding the health and safety of patients. In vivo clinical studies addressing the adverse local tissue reaction effects of metallic wear products on surrounding soft tissues and bodily fluids are less numerous. Although numerous studies have focused on the clinical significance of corrosion and wear of hip and knee replacements, research involving spine instrumentation is not well documented. This review explores how migration of metallic wear nanoparticles and trace metal ions in the area of metallic spinal implants influences the surrounding tissues and bodily fluids, and what the clinical consequences of this process may be.
- 30 March 2021
- Published by GSC Online Press in World Journal of Advanced Research and Reviews
- Vol. 9 (3) , 167-187
Open AccessReview of the local tissue reaction to metallic spinal implant debris: Ions and nanoparticles
Biologic reactivity to implant debris is the primary determinant of long-term clinical performance. The metallic implants placed in human bodies can exhibit electrochemical or mechanical corrosion that yields in the liberation of metallic products. Such implants-derived metal wear products can be present in the form of metal ions and particulate metal debris with still unknown effects on human health. In situ generation of metallic wear particles, corrosion products and in vivo trace metal ions release from metal and metallic alloys implanted into the body in spine surgery is becoming a major cause for concern regarding the health and safety of patients. In vivo clinical studies addressing the adverse local tissue reaction effects of metallic wear products on surrounding soft tissues and bodily fluids are less numerous. Although numerous studies have focused on the clinical significance of corrosion and wear of hip and knee replacements, research involving spine instrumentation is not well documented. This review explores how migration of metallic wear nanoparticles and trace metal ions in the area of metallic spinal implants influences the surrounding tissues and bodily fluids, and what the clinical consequences of this process may be.
- Open Access
Utilization of Carbon Nanotubes in Manufacturing of 3D Cartilage and Bone Scaffolds
Cartilage and bone injuries are prevalent ailments, affecting the quality of life of injured patients. Current methods of treatment are often imperfect and pose the risk of complications in the long term. Therefore, tissue engineering is a rapidly developing branch of science, which aims at discovering effective ways of replacing or repairing damaged tissues with the use of scaffolds. However, both cartilage and bone owe their exceptional mechanical properties to their complex ultrastructure, which is very difficult to reproduce artificially. To address this issue, nanotechnology was employed. One of the most promising nanomaterials in this respect is carbon nanotubes, due to their exceptional physico-chemical properties, which are similar to collagens—the main component of the extracellular matrix of these tissues. This review covers the important aspects of 3D scaffold development and sums up the existing research tackling the challenges of scaffold design. Moreover, carbon nanotubes-reinforced bone and cartilage scaffolds manufactured using the 3D bioprinting technique will be discussed as a novel tool that could facilitate the achievement of more biomimetic structures.
Open AccessUtilization of Carbon Nanotubes in Manufacturing of 3D Cartilage and Bone Scaffolds
Cartilage and bone injuries are prevalent ailments, affecting the quality of life of injured patients. Current methods of treatment are often imperfect and pose the risk of complications in the long term. Therefore, tissue engineering is a rapidly developing branch of science, which aims at discovering effective ways of replacing or repairing damaged tissues with the use of scaffolds. However, both cartilage and bone owe their exceptional mechanical properties to their complex ultrastructure, which is very difficult to reproduce artificially. To address this issue, nanotechnology was employed. One of the most promising nanomaterials in this respect is carbon nanotubes, due to their exceptional physico-chemical properties, which are similar to collagens—the main component of the extracellular matrix of these tissues. This review covers the important aspects of 3D scaffold development and sums up the existing research tackling the challenges of scaffold design. Moreover, carbon nanotubes-reinforced bone and cartilage scaffolds manufactured using the 3D bioprinting technique will be discussed as a novel tool that could facilitate the achievement of more biomimetic structures.
- Open Access
- 5 September 2019
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 20 (18) , 4371
The Role of MicroRNAs in Early Chondrogenesis of Human Induced Pluripotent Stem Cells (hiPSCs)
Human induced pluripotent stem cells (hiPSCs) play an important role in research regarding regenerative medicine. Particularly, chondrocytes differentiated from hiPSCs seems to be a promising solution for patients suffering from osteoarthritis. We decided to perform chondrogenesis in a three-week monolayer culture. Based on transcriptome analysis, hiPSC-derived chondrocytes (ChiPS) demonstrate the gene expression profile of cells from early chondrogenesis. Chondrogenic progenitors obtained by our group are characterized by significantly high expression of Hox genes, strongly upregulated during limb formation and morphogenesis. There are scanty literature data concerning the role of microRNAs in early chondrogenesis, especially in chondrogenic differentiation of hiPSCs. The main aim of this study was to investigate the microRNA expression profile and to select microRNAs (miRNAs) taking part in early chondrogenesis. Our findings allowed for selection crucial miRNAs engaged in both diminishing pluripotency state and chondrogenic process (inter alia hsa-miR-525-5p, hsa-miR-520c-3p, hsa-miR-628-3p, hsa-miR-196b-star, hsa-miR-629-star, hsa-miR-517b, has-miR-187). These miRNAs regulate early chondrogenic genes such as: HOXD10, HOXA11, RARB, SEMA3C. These results were confirmed by RT-qPCR analysis. This work contributes to a better understanding of the role of miRNAs directly involved in chondrogenic differentiation of hiPSCs. These data may result in the establishment of a more efficient protocol of obtaining chondrocyte-like cells from hiPSCs.
- 5 September 2019
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 20 (18) , 4371
Open AccessThe Role of MicroRNAs in Early Chondrogenesis of Human Induced Pluripotent Stem Cells (hiPSCs)
Human induced pluripotent stem cells (hiPSCs) play an important role in research regarding regenerative medicine. Particularly, chondrocytes differentiated from hiPSCs seems to be a promising solution for patients suffering from osteoarthritis. We decided to perform chondrogenesis in a three-week monolayer culture. Based on transcriptome analysis, hiPSC-derived chondrocytes (ChiPS) demonstrate the gene expression profile of cells from early chondrogenesis. Chondrogenic progenitors obtained by our group are characterized by significantly high expression of Hox genes, strongly upregulated during limb formation and morphogenesis. There are scanty literature data concerning the role of microRNAs in early chondrogenesis, especially in chondrogenic differentiation of hiPSCs. The main aim of this study was to investigate the microRNA expression profile and to select microRNAs (miRNAs) taking part in early chondrogenesis. Our findings allowed for selection crucial miRNAs engaged in both diminishing pluripotency state and chondrogenic process (inter alia hsa-miR-525-5p, hsa-miR-520c-3p, hsa-miR-628-3p, hsa-miR-196b-star, hsa-miR-629-star, hsa-miR-517b, has-miR-187). These miRNAs regulate early chondrogenic genes such as: HOXD10, HOXA11, RARB, SEMA3C. These results were confirmed by RT-qPCR analysis. This work contributes to a better understanding of the role of miRNAs directly involved in chondrogenic differentiation of hiPSCs. These data may result in the establishment of a more efficient protocol of obtaining chondrocyte-like cells from hiPSCs.
- Open Access
- 2 June 2019
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 20 (11) , 2711
Chondrogenic Differentiation of Pluripotent Stem Cells under Controllable Serum-Free Conditions
The repair of damaged articular cartilage using currently available implantation techniques is not sufficient for the full recovery of patients. Pluripotent stem cells (iPSC)-based therapies could bring new perspectives in the treatment of joint diseases. A number of protocols of in vitro differentiation of iPSC in chondrocytes for regenerative purposes have been recently described. However, in order to use these cells in clinics, the elimination of animal serum and feeder cells is essential. In our study, a strictly defined and controllable protocol was designed for the differentiation of pluripotent stem cells (BG01V, ND 41658*H, GPCCi001-A) in chondrocyte-like cells in serum- and a feeder cell-free system, using the embryoid bodies step. The extension of the protocol and culture conditions (monolayer versus 3D culture) was also tested after the initial 21 days of chondrogenic differentiation. Promotion of the chondrogenic differentiation in 3D culture via the elevated expression of genes related to chondrogenesis was achieved. Using immunofluorescence and immunohistochemistry staining techniques, the increased deposition of the specific extracellular matrix was indicated. As a result, chondrocyte-like cells in the early stages of their differentiation using pellet culture under fully controlled and defined conditions were obtained.
- 2 June 2019
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 20 (11) , 2711
Open AccessChondrogenic Differentiation of Pluripotent Stem Cells under Controllable Serum-Free Conditions
The repair of damaged articular cartilage using currently available implantation techniques is not sufficient for the full recovery of patients. Pluripotent stem cells (iPSC)-based therapies could bring new perspectives in the treatment of joint diseases. A number of protocols of in vitro differentiation of iPSC in chondrocytes for regenerative purposes have been recently described. However, in order to use these cells in clinics, the elimination of animal serum and feeder cells is essential. In our study, a strictly defined and controllable protocol was designed for the differentiation of pluripotent stem cells (BG01V, ND 41658*H, GPCCi001-A) in chondrocyte-like cells in serum- and a feeder cell-free system, using the embryoid bodies step. The extension of the protocol and culture conditions (monolayer versus 3D culture) was also tested after the initial 21 days of chondrogenic differentiation. Promotion of the chondrogenic differentiation in 3D culture via the elevated expression of genes related to chondrogenesis was achieved. Using immunofluorescence and immunohistochemistry staining techniques, the increased deposition of the specific extracellular matrix was indicated. As a result, chondrocyte-like cells in the early stages of their differentiation using pellet culture under fully controlled and defined conditions were obtained.