AHAndrew F. Hall

Andrew F. Hall

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew F. Hall has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and Accuracy Assessment of an Automated Image-Guided Robotic Osteotomy System

    by Prathamesh V. Bhagvath, Philippe Mercier, Andrew F. Hall

    Image-guided robotic spine surgery systems, currently used only for pedicle screw placement, have been in clinical use since 2004. Robotic spine osteotomy (bone removal and shaping), however, is still in the research phase. This article presents the development and evaluation of a KUKA-based image-guided robotic system that automates the osteotomy process, from automatic milling path determination to milling execution, using laminectomy as the experimental paradigm. An approach to quantify milling (overall path) and margin (from thecal sac penetration) accuracy is also described. System accuracy was evaluated in two experiments. In the first, common preoperative images and image fiducial points were used to perform a bilateral laminectomy on 10 identical 3D-printed vertebrae phantoms. In the second, individual preoperative images with individually identified fiducial points were used to perform a bilateral laminectomy on 4 identical 3D-printed vertebrae phantoms. The accuracy results for the first experiment were 0.19 ± 0.16 mm (milling) and 0.69 ± 0.37 mm (margin). For the second, the accuracy results were 0.24 ± 0.15 mm and 0.42 ± 0.26 mm, respectively. The results compare favorably to current accepted clinical standards for laminectomy. The system developed here implements a valuable new role for robotics in spinal surgery.


  • Guiding the Prostatic Artery Embolization Procedure With Computational Fluid Dynamics

    by Mostafa Mahmoudi, Chadrick Jennings, Keith Pereira, Andrew F. Hall, Amirhossein Arzani

    Benign prostatic hyperplasia (BPH) is a common disease associated with lower urinary tract symptoms and is the most frequent benign tumor in men. To reduce BPH therapy complications, prostatic artery embolization (PAE) was developed to replace the surgical options. PAE is a minimally invasive technique in which emboli are injected into the prostate arteries (PA), obstructing the blood flow in the hypervascular nodules. In this work, a personalized PAE treatment strategy was proposed using patient-specific computational fluid dynamics (CFD). First, the hemodynamics environment in the iliac arterial tree considering a large network of bifurcations was studied. The results showed complex blood flow patterns in the iliac arterial network. Subsequently, the transport of embolic particulates during PAE for the standard horizontal and hypothetical vertical patient positioning was simulated using Lagrangian particle tracking. Emboli of different sizes were released at various locations across the iliac arterial tree. The emboli entering the PA were mapped back to their initial location to create emboli release maps (ERMs). The obtained ERMs during the standard patient positioning for smaller emboli at certain release locations showed distinct regions in which if the emboli were released within these regions, all of them would reach the PA without nontarget embolization. During the hypothetical vertical patient positioning, the larger emboli formed a larger coherent region in the ERMs. Our patient-specific model can be used to find the best spatial location for emboli injection and perform the embolization procedure with minimal off-target delivery.


  • Open Access

    Automated Polyaxial Screw Placement Using a Commercial-Robot-Based, Image-Guided Spine Surgery System

    by Alexander D. Smith, Jacob Chapin, Paul V. Birinyi, Prathamesh V. Bhagvath, Andrew F. Hall

    Robotic spine surgery systems, used for placing pedicle screws, have been in clinical use since 2004; however, these systems act only as a positioner for guide tubes, which the surgeon uses to manually advance tools to prepare the site and place hardware (e.g. pedicle screws). This paper presents the development, operation, and evaluation of a new, commercial-robot-based, image-guided surgery system that automates the process of bone preparation and polyaxial screw placement. The system is based on the KUKA LBR iiwa 7-axis collaborative robot. Fiducial marker and screw locations are defined on a pre-operative CT image using the 3D Slicer open source image visualization platform. The system uses the robot’s internal localization system for registration, by touching fiducial markers in a hand-guiding mode. A rotary-motor end effector with exchangeable tools is used for both hole-drilling and screw placement. A novel single-motor based mechanism was developed for placing polyaxial pedicle screws. An accuracy test was performed by placing polyaxial screws in synthetic vertebrae which mimic the mechanical properties of human bone. In placing 10 screws, the entry point accuracy was 0.49 ± 0.17 mm and the destination point accuracy was 1.49 ± 0.46 mm. The results compare favorably to evaluations of commercial robotic spine surgery systems.


  • Open Access

    Tissue Engineering Scaffolds Fabricated in Dissolvable 3D-Printed Molds for Patient-Specific Craniofacial Bone Regeneration

    by Angela Alarcon De la Lastra, Katherine R. Hixon, Lavanya Aryan, Amanda N. Banks, Alexander Y. Lin, Andrew F. Hall, Scott A. Sell

    The current gold standard treatment for oral clefts is autologous bone grafting. This treatment, however, presents another wound site for the patient, greater discomfort, and pediatric patients have less bone mass for bone grafting. A potential alternative treatment is the use of tissue engineered scaffolds. Hydrogels are well characterized nanoporous scaffolds and cryogels are mechanically durable, macroporous, sponge-like scaffolds. However, there has been limited research on these scaffolds for cleft craniofacial defects. 3D-printed molds can be combined with cryogel/hydrogel fabrication to create patient-specific tissue engineered scaffolds. By combining 3D-printing technology and scaffold fabrication, we were able to create scaffolds with the geometry of three cleft craniofacial defects. The scaffolds were then characterized to assess the effect of the mold on their physical properties. While the scaffolds were able to completely fill the mold, creating the desired geometry, the overall volumes were smaller than expected. The cryogels possessed porosities ranging from 79.7% to 87.2% and high interconnectivity. Additionally, the cryogels swelled from 400% to almost 1500% of their original dry weight while the hydrogel swelling did not reach 500%, demonstrating the ability to fill a defect site. Overall, despite the complex geometry, the cryogel scaffolds displayed ideal properties for bone reconstruction.


  • Open Access

    Three‐dimensional printing CT‐derived objects with controllable radiopacity

    by Borhan Alhosseini Hamedani, Alexa Melvin, Kirubahara Vaheesan, Sameer Gadani, Keith Pereira, Andrew F. Hall

    Purpose: The goal of this work was to develop phantoms for the optimization of pre‐operative computed tomography (CT) scans of the prostate artery, which are used for embolization planning.Methods: Acrylonitrile butadiene styrene (ABS) pellets were doped with barium sulfate and extruded into filaments suitable for 3D printing on a fused deposition modeling (FDM) printer. Cylinder phantoms were created to evaluate radiopacity as a function of doping percentage. Small‐diameter tree phantoms were created to assess their composition and dimensional accuracy. A half‐pelvis phantom was created using clinical CT images, to assess the printer's control over cortical bone thickness and cancellous bone attenuation. CT‐derived prostate artery phantoms were created to simulate complex, contrast‐filled arteries.Results: A linear relationship (R = 0.998) was observed between barium sulfate added (0%–10% by weight), and radiopacity (−31 to 1454 Hounsfield Units [HU]). Micro‐CT scans showed even distribution of the particles, with air pockets comprising 0.36% by volume. The small vessels were found to be oversized by a consistent amount of 0.08 mm. Micro‐CT scans revealed that the phantoms' interiors were completely filled in. The maximum HU values of cortical bone in the phantom were lower than that of the filament, a result of CT image reconstruction. Creation of cancellous bone regions with lower HU values, using the printer's infill parameter, was successful. Direct volume renderings of the pelvis and prostate artery were similar to the clinical CT, with the exception that the surfaces of the phantom objects were not as smooth.Conclusions: It is possible to reliably create FDM 3D printer filaments with predictable radiopacity in a wide range of attenuation values, which can be used to print dimensionally accurate radiopaque objects derived from CT data. Phantoms of this type can be quickly and inexpensively developed to assess and optimize CT protocols for specific clinical applications.


  • Cryogel scaffolds from patient-specific 3D-printed molds for personalized tissue-engineered bone regeneration in pediatric cleft-craniofacial defects

    by Katherine R Hixon, Alexa M Melvin, Alexander Y Lin, Andrew F Hall, Scott A Sell

    Bone defects are extremely common in children with cleft-craniofacial conditions, especially those with alveolar cleft defects and cranial defects. This study used patient-specific 3D-printed molds derived from computed tomography and cryogel scaffold fabrication as a proof of concept for the creation of site-specific implants for bone reconstruction. Cryogel scaffolds are unique tissue-engineered constructs formed at sub-zero temperatures. When thawed, the resulting structure is macroporous, sponge-like, and mechanically durable. Due to these unique properties, cryogels have excellent potential for the treatment of patient-specific bone defects; however, there is little literature on their use in cleft-craniofacial defects. While 3D-printing technology currently lacks the spatial resolution to print the microstructure necessary for bone regeneration, it can be used to create site-specific molds. Thus, it is ideal to integrate these techniques for the fabrication of scaffolds with patient-specific geometry. Overall, all cryogels possessed appropriate geometry to allow for cell infiltration after 28 days. Additionally, suitable mechanical durability was demonstrated where, despite mold geometry, all cryogels could be compressed without exhibiting crack propagation. Such a patient-specific scaffold would be ideal in pediatric cleft-craniofacial defects, as these are complex 3D defects and children have less donor bone availability.