Hongmei Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hongmei Hu has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoning Zhang
State Key Laboratory of Resource Insects, College of Sericulture, Textile and Biomass Sciences
8 shared publications Tiejun Li
Key Laboratory of Sustainable Utilization of Technology Research for Fisheries Resources of Zhejiang Province, Zhejiang Marine Fisheries Research Institute, Zhoushan 316021, China
6 shared publications- Yuanming Guo
Key Laboratory of Sustainable Utilization of Technology Research for Fishery Resource of Zhejiang Province, Zhejiang Marine Fisheries Research Institute, Zhoushan 316021, China
6 shared publications - Heyong Cheng
College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
5 shared publications Yuanming Guo
Key Laboratory of Sustainable Utilization of Technology Research for Fisheries Resources of Zhejiang Province, Zhejiang Marine Fisheries Research Institute, Zhoushan 316021, China
5 shared publicationsXiaoning Zhang
State Key Laboratory of Silkworm Genome Biology, College of Sericulture, Textile and Biomass Sciences, Southwest University, Chongqing 400715, China
4 shared publications
Latest Publications
- Open Access
Tetracyclines Removal from Aquaculture Effluents by Waste Mussel Shells After Thermal Modification
As a class of low-cost and broad-spectrum antibiotics in wide aquaculture use, residues of tetracyclines (TCs) are imperiling aquatic organisms and public health worldwide, leading to a high demand for TC removal from the aquaculture environment. In addition, considerable consumption of thick-shell mussels generates massive mussel shell waste, and their treatment has been an economic and environmental issue. Herein, a low-cost and high-efficiency mussel shells-based material was successfully prepared for TC removal by thermal modification of shell waste of Mytilus coruscus. Morphological and structural characterizations revealed the phase transformation of calcium carbonate to calcium oxide. The shell-based material calcined at 1050 °C (MC1050) yielded a Langmuir-fitted maximum removal capacity (qm) of 68.0 mg/g towards oxytetracycline (OTC). Thermodynamic calculations indicate that OTC removal by MC1050 is a spontaneous and endothermic process. OTC removal by MC1050 is likely achieved via multiple co-existing pathways, where Ca-OTC co-precipitation driven by CaO-phase hydration and resultant high-pH conditions dominates, accompanied by auxiliary surface-interaction contributions. Furthermore, MC1050 achieves removal efficiencies exceeding 96% for the ten target TCs spiked at 20 μg/L in real-world freshwater and marine aquaculture effluent matrices. Overall, the developed shell-based material shows promising performance for wastewater treatment and facilitates the resource utilization of waste mussel shells.
Open AccessTetracyclines Removal from Aquaculture Effluents by Waste Mussel Shells After Thermal Modification
As a class of low-cost and broad-spectrum antibiotics in wide aquaculture use, residues of tetracyclines (TCs) are imperiling aquatic organisms and public health worldwide, leading to a high demand for TC removal from the aquaculture environment. In addition, considerable consumption of thick-shell mussels generates massive mussel shell waste, and their treatment has been an economic and environmental issue. Herein, a low-cost and high-efficiency mussel shells-based material was successfully prepared for TC removal by thermal modification of shell waste of Mytilus coruscus. Morphological and structural characterizations revealed the phase transformation of calcium carbonate to calcium oxide. The shell-based material calcined at 1050 °C (MC1050) yielded a Langmuir-fitted maximum removal capacity (qm) of 68.0 mg/g towards oxytetracycline (OTC). Thermodynamic calculations indicate that OTC removal by MC1050 is a spontaneous and endothermic process. OTC removal by MC1050 is likely achieved via multiple co-existing pathways, where Ca-OTC co-precipitation driven by CaO-phase hydration and resultant high-pH conditions dominates, accompanied by auxiliary surface-interaction contributions. Furthermore, MC1050 achieves removal efficiencies exceeding 96% for the ten target TCs spiked at 20 μg/L in real-world freshwater and marine aquaculture effluent matrices. Overall, the developed shell-based material shows promising performance for wastewater treatment and facilitates the resource utilization of waste mussel shells.
- Open Access
Determination and Ecological Risk Assessment of Organophosphate Esters in Drinking and Environmental Waters by Automated Liquid–Liquid Extraction Coupled with GC-MS/MS
Organophosphate esters (OPEs) are ubiquitous in the global water environment and may pose potential risks to aquatic ecosystems and human health. Herein, we present a simple and efficient method for accurate quantification of nineteen OPEs in water based on automated liquid–liquid extraction (LLE) with dichloromethane and hexane, followed by gas chromatography–tandem mass spectrometry (GC-MS/MS) with isotope dilution calibration. This method demonstrated a negligible matrix effect, satisfactory recoveries (70–120%), and low limits of detection (0.46–2.32 ng/L). A total of 3, 9, 10, and 11 OPEs were detected in Wahaha pure water, tap water, river water, and seawater, respectively, with total OPE (∑OPE) concentration ranges of 8.23–18.5 ng/L, 159–218 ng/L, 202–623 ng/L, and 111–175 ng/L, respectively. Among the detected OPEs, tris(2-chloroethyl) phosphate (TCEP) and tris(1-chloro-2-propyl) phosphate (TCIPP) were the predominant compounds in four test water matrices. The risk quotient (RQ) results revealed that OPEs exhibited a low risk to algae, crustaceans and fish in the river water of Zhoushan and seawater of Sanmen Bay. Overall, the proposed method is sensitive and reliable for routine OPE analysis in drinking and environmental waters.
Open AccessDetermination and Ecological Risk Assessment of Organophosphate Esters in Drinking and Environmental Waters by Automated Liquid–Liquid Extraction Coupled with GC-MS/MS
Organophosphate esters (OPEs) are ubiquitous in the global water environment and may pose potential risks to aquatic ecosystems and human health. Herein, we present a simple and efficient method for accurate quantification of nineteen OPEs in water based on automated liquid–liquid extraction (LLE) with dichloromethane and hexane, followed by gas chromatography–tandem mass spectrometry (GC-MS/MS) with isotope dilution calibration. This method demonstrated a negligible matrix effect, satisfactory recoveries (70–120%), and low limits of detection (0.46–2.32 ng/L). A total of 3, 9, 10, and 11 OPEs were detected in Wahaha pure water, tap water, river water, and seawater, respectively, with total OPE (∑OPE) concentration ranges of 8.23–18.5 ng/L, 159–218 ng/L, 202–623 ng/L, and 111–175 ng/L, respectively. Among the detected OPEs, tris(2-chloroethyl) phosphate (TCEP) and tris(1-chloro-2-propyl) phosphate (TCIPP) were the predominant compounds in four test water matrices. The risk quotient (RQ) results revealed that OPEs exhibited a low risk to algae, crustaceans and fish in the river water of Zhoushan and seawater of Sanmen Bay. Overall, the proposed method is sensitive and reliable for routine OPE analysis in drinking and environmental waters.
- 29 January 2026
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 504, 141256
Simultaneous preconcentration and penta-elemental speciation analysis of Cr, As, Cd, Hg, and Pb by online solid-phase extraction and high-performance liquid chromatography–inductively coupled plasma mass spectrometry
- 29 January 2026
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 504, 141256
Simultaneous preconcentration and penta-elemental speciation analysis of Cr, As, Cd, Hg, and Pb by online solid-phase extraction and high-performance liquid chromatography–inductively coupled plasma mass spectrometry
- 28 January 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1771, 466752
Accurate quantification of quinolones in marine sediment by UPLC-MS/MS after ultrasonic extraction and automated SPE clean-up
- 28 January 2026
- Published by Elsevier in Journal of Chromatography A
- Vol. 1771, 466752
Accurate quantification of quinolones in marine sediment by UPLC-MS/MS after ultrasonic extraction and automated SPE clean-up
- 15 January 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 487, 137245
Occurrence, bioaccumulation, and ecological and health risks of Cd, Sn, Hg, and Pb compounds in shrimp and fish from aquaculture ponds
- 15 January 2025
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 487, 137245
Occurrence, bioaccumulation, and ecological and health risks of Cd, Sn, Hg, and Pb compounds in shrimp and fish from aquaculture ponds
- Open Access
Determination and Ecological Risk Assessment of Quinolone Antibiotics in Drinking and Environmental Waters Using Fully Automated Disk-Based SPE Coupled with UPLC–MS/MS
Quinolone antibiotics (QNs) contamination in the aquatic environment is a global public health issue considering their resistance and mobility. In this study, a simple, efficient, and sensitive method was developed for the accurate quantification of fifteen QNs in water using automated disk-based solid-phase extraction (SPE) coupled with ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS). By utilizing a 3M SDB-XC disk to enrich QNs from a 1000 mL water sample, the detection limits were improved to 0.008–0.055 ng/L due to the satisfactory enrichment factors of 897−1136, but only requiring about 60 min per six samples. The linearity of the method ranged from 0.05 to 100 μg/L for the 15 QNs, with correlation coefficients of 0.9992–0.9999, and the recoveries were in the range of 81–114%, with relative standard deviations of 0.2–13.3% (n = 6). The developed method was applicable for the quantification of trace QNs at low ng/L levels in drinking and environmental waters. The results showed that no QNs were detected in tap water, while three and four QNs were detected in the river water of Zhoushan and the seawater of Daiquyang and Yueqing Bay, East China, respectively, with a total concentration of 1.600–8.511 ng/L and 1.651–16.421 ng/L, respectively. Among the detected QNs, ofloxacin (OFL) was the predominant compound in river water, while enrofloxacin (ENR) was predominant in seawater. The risk quotient (RQ) results revealed that QNs posed a low risk to crustaceans and fish, but a low-to-medium risk to algae, and OFL presented the main ecological risk factor in river water, while ENR and CIP in seawater. Overall, the proposed automated disk-based SPE–UPLC–MS/MS method is highly efficient and sensitive, making it suitable for routine analysis of QNs in drinking and environmental waters.
Open AccessDetermination and Ecological Risk Assessment of Quinolone Antibiotics in Drinking and Environmental Waters Using Fully Automated Disk-Based SPE Coupled with UPLC–MS/MS
Quinolone antibiotics (QNs) contamination in the aquatic environment is a global public health issue considering their resistance and mobility. In this study, a simple, efficient, and sensitive method was developed for the accurate quantification of fifteen QNs in water using automated disk-based solid-phase extraction (SPE) coupled with ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS). By utilizing a 3M SDB-XC disk to enrich QNs from a 1000 mL water sample, the detection limits were improved to 0.008–0.055 ng/L due to the satisfactory enrichment factors of 897−1136, but only requiring about 60 min per six samples. The linearity of the method ranged from 0.05 to 100 μg/L for the 15 QNs, with correlation coefficients of 0.9992–0.9999, and the recoveries were in the range of 81–114%, with relative standard deviations of 0.2–13.3% (n = 6). The developed method was applicable for the quantification of trace QNs at low ng/L levels in drinking and environmental waters. The results showed that no QNs were detected in tap water, while three and four QNs were detected in the river water of Zhoushan and the seawater of Daiquyang and Yueqing Bay, East China, respectively, with a total concentration of 1.600–8.511 ng/L and 1.651–16.421 ng/L, respectively. Among the detected QNs, ofloxacin (OFL) was the predominant compound in river water, while enrofloxacin (ENR) was predominant in seawater. The risk quotient (RQ) results revealed that QNs posed a low risk to crustaceans and fish, but a low-to-medium risk to algae, and OFL presented the main ecological risk factor in river water, while ENR and CIP in seawater. Overall, the proposed automated disk-based SPE–UPLC–MS/MS method is highly efficient and sensitive, making it suitable for routine analysis of QNs in drinking and environmental waters.
- 9 August 2024
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (10) , 912-921
Determination of Volatile Halogenated Hydrocarbons in Drinking and Environmental Waters by Headspace Gas Chromatography
Volatile halogenated hydrocarbons (VHHs) are annually produced and released into the environment, posing a threat to public health. In this study, a simple, rapid, sensitive and automated method based on headspace and gas chromatography (GC) with electron-capture detection was described for the determination of VHHs in different concentration levels in water samples. The proposed headspace GC method was initially optimized, and the optimum experimental conditions found were 10-mL water sample containing 20% w/v sodium chloride placed in a 20-mL vial and stirred at 60°C for 35 min, and then 14 VHHs were well separated on DB-35 MS capillary column with a split ratio of 12.5: 1. The limits of detection were in the low μg/L level, ranging between 0.01 and 0.6 μg/L. Finally optimized method was applied for determination 14 VHHs in drinking and environmental waters. The total mean concentrations of VHHs were 34.962, 26.183, 3.228 and 647.344 μg/L in tap water, purified water with 1-year-old filter element, seawater and effluents, respectively. However, no VHHs was detected in purified water with a new filter element. The main composition is different among different water matrix, which may be attributed to their different sources.
- 9 August 2024
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 62 (10) , 912-921
Determination of Volatile Halogenated Hydrocarbons in Drinking and Environmental Waters by Headspace Gas Chromatography
Volatile halogenated hydrocarbons (VHHs) are annually produced and released into the environment, posing a threat to public health. In this study, a simple, rapid, sensitive and automated method based on headspace and gas chromatography (GC) with electron-capture detection was described for the determination of VHHs in different concentration levels in water samples. The proposed headspace GC method was initially optimized, and the optimum experimental conditions found were 10-mL water sample containing 20% w/v sodium chloride placed in a 20-mL vial and stirred at 60°C for 35 min, and then 14 VHHs were well separated on DB-35 MS capillary column with a split ratio of 12.5: 1. The limits of detection were in the low μg/L level, ranging between 0.01 and 0.6 μg/L. Finally optimized method was applied for determination 14 VHHs in drinking and environmental waters. The total mean concentrations of VHHs were 34.962, 26.183, 3.228 and 647.344 μg/L in tap water, purified water with 1-year-old filter element, seawater and effluents, respectively. However, no VHHs was detected in purified water with a new filter element. The main composition is different among different water matrix, which may be attributed to their different sources.
- Open Access
Rapid Determination of Tetracyclines in Drinking and Environmental Waters Using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry
The abuse and irrational use of tetracyclines (TCs) in human medicine and animal husbandry has become a serious concern, affecting the ecological environment and human health. The aim of this study was to develop a sensitive and selective method using fully automatic solid-phase extraction coupled with ultra-performance liquid chromatography–tandem mass spectrometry for the determination of twelve TCs in water. Four isotope-labeled internal standards for TCs were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the optimum experimental conditions found were 1.0 L water sample with 0.5 g/L Na2EDTA (pH 3.0) extracted and enriched by CNW HLB cartridge and eluted by 4 mL of acetone:methanol (v/v, 1:1). The enrichment factors were up to 798−1059 but only requiring about 60 min per six samples. Under the optimized conditions, the linearity of the method ranged from 0.2 to 100 μg/L for 12 TCs, the detection limits were as low as 0.01−0.15 ng/L, and the recoveries were in the range of 70%–118%, with relative standard deviations less than 15%. The developed method can be successfully utilized for the determination of 12 TCs in pure water, tap water, river water, and mariculture seawater. In summary, three and six TCs were detected in river water and mariculture seawater, respectively, with total concentrations of 0.074–0.520 ng/L (mean 0.248 ng/L) and 0.792–58.369 ng/L (12.629 ng/L), respectively. Tetracycline (TC) and oxytetracycline (OTC) were the dominant TCs in river water, while doxytetracycline (DXC) and OTC were dominant in mariculture seawater.
Open AccessRapid Determination of Tetracyclines in Drinking and Environmental Waters Using Fully Automatic Solid-Phase Extraction with Ultra-Performance Liquid Chromatography–Tandem Mass Spectrometry
The abuse and irrational use of tetracyclines (TCs) in human medicine and animal husbandry has become a serious concern, affecting the ecological environment and human health. The aim of this study was to develop a sensitive and selective method using fully automatic solid-phase extraction coupled with ultra-performance liquid chromatography–tandem mass spectrometry for the determination of twelve TCs in water. Four isotope-labeled internal standards for TCs were used to correct matrix effects. Several parameters affecting extraction efficiency were systematically optimized, and the optimum experimental conditions found were 1.0 L water sample with 0.5 g/L Na2EDTA (pH 3.0) extracted and enriched by CNW HLB cartridge and eluted by 4 mL of acetone:methanol (v/v, 1:1). The enrichment factors were up to 798−1059 but only requiring about 60 min per six samples. Under the optimized conditions, the linearity of the method ranged from 0.2 to 100 μg/L for 12 TCs, the detection limits were as low as 0.01−0.15 ng/L, and the recoveries were in the range of 70%–118%, with relative standard deviations less than 15%. The developed method can be successfully utilized for the determination of 12 TCs in pure water, tap water, river water, and mariculture seawater. In summary, three and six TCs were detected in river water and mariculture seawater, respectively, with total concentrations of 0.074–0.520 ng/L (mean 0.248 ng/L) and 0.792–58.369 ng/L (12.629 ng/L), respectively. Tetracycline (TC) and oxytetracycline (OTC) were the dominant TCs in river water, while doxytetracycline (DXC) and OTC were dominant in mariculture seawater.
- 27 January 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1294, 342294
Simultaneous preconcentration and quantification of ultra-trace tin and lead species in seawater by online SPE coupled with HPLC-ICP-MS
- 27 January 2024
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1294, 342294
Simultaneous preconcentration and quantification of ultra-trace tin and lead species in seawater by online SPE coupled with HPLC-ICP-MS
- 26 January 2024
- Published by Elsevier in Food Chemistry
- Vol. 443, 138552
Simultaneous quantification of tin and lead species in Antarctic krill and fish by interfacing high-performance liquid chromatography with inductively coupled plasma mass spectrometry based on strong cation-exchange and Amphion columns
- 26 January 2024
- Published by Elsevier in Food Chemistry
- Vol. 443, 138552
Simultaneous quantification of tin and lead species in Antarctic krill and fish by interfacing high-performance liquid chromatography with inductively coupled plasma mass spectrometry based on strong cation-exchange and Amphion columns