Jun Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jun Tan has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Lijun Li
Departments of3Spine Surgery and
6 shared publicationsMingjie Yang
Departments of3Spine Surgery and
6 shared publicationsGuixin Sun
Traumatology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
4 shared publicationsSong Guo
Departments of3Spine Surgery and
4 shared publicationsCheng Zeng
Department of Spine, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China
3 shared publicationsJunxiang Wen
Department of Orthopaedics, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
3 shared publications
Latest Publications
- 15 July 2019
- Published by Springer Nature in European Spine Journal
- Vol. 28 (9) , 2223
Letter to the Editor concerning “Intraosseous basivertebral nerve ablation for the treatment of chronic low back pain: a prospective randomized double-blind sham-controlled multi-center study” by Fischgrund JS, et al. [Eur Spine J; (2018) 27(5): 1146–1156]
- 15 July 2019
- Published by Springer Nature in European Spine Journal
- Vol. 28 (9) , 2223
Letter to the Editor concerning “Intraosseous basivertebral nerve ablation for the treatment of chronic low back pain: a prospective randomized double-blind sham-controlled multi-center study” by Fischgrund JS, et al. [Eur Spine J; (2018) 27(5): 1146–1156]
- 1 October 2018
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 29 (4) , 470-480
Recovery of respiratory function and autonomic diaphragm movement following unilateral recurrent laryngeal nerve to phrenic nerve anastomosis in rabbits
The authors studied restoration of respiratory function in rabbits, using the recurrent laryngeal nerve to restore function after the phrenic nerve had been severed. The results of this animal study are encouraging and suggest that a similar technique could possibly be used to help patients with severe cervical spinal cord injuries.
- 1 October 2018
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 29 (4) , 470-480
Recovery of respiratory function and autonomic diaphragm movement following unilateral recurrent laryngeal nerve to phrenic nerve anastomosis in rabbits
The authors studied restoration of respiratory function in rabbits, using the recurrent laryngeal nerve to restore function after the phrenic nerve had been severed. The results of this animal study are encouraging and suggest that a similar technique could possibly be used to help patients with severe cervical spinal cord injuries.
- Open Access
- 26 January 2018
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 22 (4) , 2098-2109
Leptin regulates disc cartilage endplate degeneration and ossification through activation of the MAPK‐ERK signalling pathway in vivo and in vitro
Recent findings demonstrate that leptin plays a significant role in chondrocyte and osteoblast differentiation. However, the mechanisms by which leptin acts on cartilage endplate (CEP) cells to give rise to calcification are still unclear. The aim of this study was to evaluate the effects of leptin that induced mineralization of CEP cells in vitro and in vivo. We constructed a rat model of lumbar disc degeneration and determined that leptin was highly expressed in the presence of CEP calcification. Rat CEP cells treated with or without leptin were used for in vitro analysis using RT‐PCR and Western blotting to examine the expression of osteocalcin (OCN) and runt‐related transcription factor 2 (Runx2). Both OCN and Runx2 expression levels were significantly increased in a dose‐ and time‐dependent manner. Leptin activated ERK1/2 and STAT3 phosphorylation in a time‐dependent manner. Inhibition of phosphorylated ERK1/2 using targeted siRNA suppressed leptin‐induced OCN and Runx2 expression and blocked the formation of mineralized nodules in CEP cells. We further demonstrated that exogenous leptin induced matrix mineralization of CEP cells in vivo. We suggest that leptin promotes the osteoblastic differentiation of CEP cells via the MAPK/ERK signal transduction pathway and may be used to investigate the mechanisms of disc degeneration.
- 26 January 2018
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 22 (4) , 2098-2109
Open AccessLeptin regulates disc cartilage endplate degeneration and ossification through activation of the MAPK‐ERK signalling pathway in vivo and in vitro
Recent findings demonstrate that leptin plays a significant role in chondrocyte and osteoblast differentiation. However, the mechanisms by which leptin acts on cartilage endplate (CEP) cells to give rise to calcification are still unclear. The aim of this study was to evaluate the effects of leptin that induced mineralization of CEP cells in vitro and in vivo. We constructed a rat model of lumbar disc degeneration and determined that leptin was highly expressed in the presence of CEP calcification. Rat CEP cells treated with or without leptin were used for in vitro analysis using RT‐PCR and Western blotting to examine the expression of osteocalcin (OCN) and runt‐related transcription factor 2 (Runx2). Both OCN and Runx2 expression levels were significantly increased in a dose‐ and time‐dependent manner. Leptin activated ERK1/2 and STAT3 phosphorylation in a time‐dependent manner. Inhibition of phosphorylated ERK1/2 using targeted siRNA suppressed leptin‐induced OCN and Runx2 expression and blocked the formation of mineralized nodules in CEP cells. We further demonstrated that exogenous leptin induced matrix mineralization of CEP cells in vivo. We suggest that leptin promotes the osteoblastic differentiation of CEP cells via the MAPK/ERK signal transduction pathway and may be used to investigate the mechanisms of disc degeneration.
- 1 June 2017
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 30 (5) , E592-E597
Development of a Remodeled Caspar Retractor and Its Application in the Measurement of Distractive Resistance in an In Vitro Anterior Cervical Distraction Model
Study Design: In vitro biomechanical study of the cervical intervertebral distraction using a remodeled Caspar retractor. Objective: To investigate the torques required for distraction to different heights in an in vitro C3–C4 anterior cervical distraction model using a remodeled Caspar retractor, focusing on the influence of the intervertebral disk, posterior longitudinal ligament (PLL), and ligamentum flavum (LF). Summary of Background Data: No previous studies have reported on the torques required for distraction to various heights or the factors resisting distraction in anterior cervical discectomy and fusion. Methods: Anterior cervical distractions at C3–C4 was performed in 6 cadaveric specimens using a remodeled Caspar retractor, under 4 conditions: A, before disk removal; B, after disk removal; C, after disk and PLL removal; and D, after disk and PLL removal and cutting of the LF. Distraction was performed for 5 teeth, and distractive torque of each tooth was recorded. Results: The torque increased with distraction height under all conditions. There was a sudden increase in torque at the fourth tooth under conditions B and C, but not D. Under condition A, distraction to the third tooth required 84.8±13.3 cN m. Under conditions B and C, distraction to the third tooth required <13 cN m, and further distraction required dramatically increased torque. Under condition D, no marked increase in torque was recorded. Conclusions: Distraction of the intervertebral space was much easier after disk removal. An intact LF caused a sudden marked increase in the force required for distraction, possibly indicating the point at which the LF was fully stretched. This increase in resistance may help to determine the optimal distraction height to avoid excessive stress to the endplate spacer. The remodeled Caspar retractor in the present study may provide a feasible and convenient method for intraoperative measurement of distractive resistance.
- 1 June 2017
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 30 (5) , E592-E597
Development of a Remodeled Caspar Retractor and Its Application in the Measurement of Distractive Resistance in an In Vitro Anterior Cervical Distraction Model
Study Design: In vitro biomechanical study of the cervical intervertebral distraction using a remodeled Caspar retractor. Objective: To investigate the torques required for distraction to different heights in an in vitro C3–C4 anterior cervical distraction model using a remodeled Caspar retractor, focusing on the influence of the intervertebral disk, posterior longitudinal ligament (PLL), and ligamentum flavum (LF). Summary of Background Data: No previous studies have reported on the torques required for distraction to various heights or the factors resisting distraction in anterior cervical discectomy and fusion. Methods: Anterior cervical distractions at C3–C4 was performed in 6 cadaveric specimens using a remodeled Caspar retractor, under 4 conditions: A, before disk removal; B, after disk removal; C, after disk and PLL removal; and D, after disk and PLL removal and cutting of the LF. Distraction was performed for 5 teeth, and distractive torque of each tooth was recorded. Results: The torque increased with distraction height under all conditions. There was a sudden increase in torque at the fourth tooth under conditions B and C, but not D. Under condition A, distraction to the third tooth required 84.8±13.3 cN m. Under conditions B and C, distraction to the third tooth required <13 cN m, and further distraction required dramatically increased torque. Under condition D, no marked increase in torque was recorded. Conclusions: Distraction of the intervertebral space was much easier after disk removal. An intact LF caused a sudden marked increase in the force required for distraction, possibly indicating the point at which the LF was fully stretched. This increase in resistance may help to determine the optimal distraction height to avoid excessive stress to the endplate spacer. The remodeled Caspar retractor in the present study may provide a feasible and convenient method for intraoperative measurement of distractive resistance.
- 1 March 2017
- Published by Elsevier in Biomaterials
- Vol. 121, 1-14
Calcium phosphate-phosphorylated adenosine hybrid microspheres for anti-osteosarcoma drug delivery and osteogenic differentiation
- 1 March 2017
- Published by Elsevier in Biomaterials
- Vol. 121, 1-14
Calcium phosphate-phosphorylated adenosine hybrid microspheres for anti-osteosarcoma drug delivery and osteogenic differentiation
- Open Access
- 22 December 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (12) , e0168498
A Biomechanical Stability Study of Extraforaminal Lumbar Interbody Fusion on the Cadaveric Lumbar Spine Specimens
Transforaminal lumbar interbody fusion (TLIF) is an effective surgery for lumbar degenerative disease. However, this fusion technique requires resection of inferior facet joint to provide access for superior facet joint resection, which results in reduced lumbar spinal stability and unnecessary trauma. We have previously developed extraforaminal lumbar interbody fusion (ELIF) that can avoid back muscle injury with direct nerve root decompression. This study aims to show that ELIF enhances lumbar spinal stability in comparison to TLIF by comparing lumbar spinal stability of L4–L5 range of motion (ROM) on 12 cadaveric spine specimens after performing TLIF or ELIF. 12 cadaveric spine specimens were randomly divided and treated in accordance with the different internal fixations, including ELIF with a unilateral pedicle screw (ELIF+UPS), TLIF with a unilateral pedicle screw (TLIF+UPS), TLIF with a bilateral pedicle screw (TLIF+BPS), ELIF with a unilateral pedicle screw and translaminar facet screw (ELIF+UPS+TLFS) and ELIF with a bilateral pedicle screw (ELIF+BPS). The treatment groups were exposed to a 400-N load and 6 N·m movement force to calculate the angular displacement of L4-L5 during anterior flexion, posterior extension, lateral flexion and rotation operation conditions. The ROM in ELIF+UPS group was smaller than that of TLIF+UPS group under all operating conditions, with the significant differences in left lateral flexion and right rotation by 36.15% and 25.97% respectively. The ROM in ELIF+UPS group was higher than that in TLIF+BPS group. The ROM in the ELIF+UPS+TLFS group was much smaller than that in the ELIF+UPS group, but was not significantly different than that in the TLIF+BPS group. Despite that TLIF+BPS has great stability, which can be comparable by that of ELIF+UPS. Additionally, ELIF stability can be further improved by using translaminar facet screws without causing more tissue damage to patient.
- 22 December 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (12) , e0168498
Open AccessA Biomechanical Stability Study of Extraforaminal Lumbar Interbody Fusion on the Cadaveric Lumbar Spine Specimens
Transforaminal lumbar interbody fusion (TLIF) is an effective surgery for lumbar degenerative disease. However, this fusion technique requires resection of inferior facet joint to provide access for superior facet joint resection, which results in reduced lumbar spinal stability and unnecessary trauma. We have previously developed extraforaminal lumbar interbody fusion (ELIF) that can avoid back muscle injury with direct nerve root decompression. This study aims to show that ELIF enhances lumbar spinal stability in comparison to TLIF by comparing lumbar spinal stability of L4–L5 range of motion (ROM) on 12 cadaveric spine specimens after performing TLIF or ELIF. 12 cadaveric spine specimens were randomly divided and treated in accordance with the different internal fixations, including ELIF with a unilateral pedicle screw (ELIF+UPS), TLIF with a unilateral pedicle screw (TLIF+UPS), TLIF with a bilateral pedicle screw (TLIF+BPS), ELIF with a unilateral pedicle screw and translaminar facet screw (ELIF+UPS+TLFS) and ELIF with a bilateral pedicle screw (ELIF+BPS). The treatment groups were exposed to a 400-N load and 6 N·m movement force to calculate the angular displacement of L4-L5 during anterior flexion, posterior extension, lateral flexion and rotation operation conditions. The ROM in ELIF+UPS group was smaller than that of TLIF+UPS group under all operating conditions, with the significant differences in left lateral flexion and right rotation by 36.15% and 25.97% respectively. The ROM in ELIF+UPS group was higher than that in TLIF+BPS group. The ROM in the ELIF+UPS+TLFS group was much smaller than that in the ELIF+UPS group, but was not significantly different than that in the TLIF+BPS group. Despite that TLIF+BPS has great stability, which can be comparable by that of ELIF+UPS. Additionally, ELIF stability can be further improved by using translaminar facet screws without causing more tissue damage to patient.
- Open Access
- 26 August 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (8) , e105646
Digitalized Design of Extraforaminal Lumbar Interbody Fusion: A Computer-Based Simulation and Cadaveric Study
This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF), a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study. The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the superior articular process, dilation of the vertebral foramen, and placement of pedicle screws and a cage. ELIF anatomical measures were documented using a digitalized technique and subsequently validated on fresh cadavers. The use of the Mimics allowed for the vivid simulation of ELIF surgical procedures, while the cadaveric study proved the feasibility of this novel approach. ELIF had a relatively lateral access approach that was located 8–9 cm lateral to the median line with an access depth of approximately 9 cm through the intermuscular space. Dissection of the superior articular processes could fully expose the target intervertebral discs and facilitate a more inclined placement of the pedicle screws and cage with robust enhancement. According to the computer-based simulation and cadaveric study, it is feasible to perform ELIF. Further research including biomechanical study is needed to prove ELIF has a superior ability to preserve the posterior tension bands of the spinal column, with similar effects on spinal decompression, fixation, and fusion, and if it can enhance post-fusion spinal stability and expedites postoperative recovery.
- 26 August 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (8) , e105646
Open AccessDigitalized Design of Extraforaminal Lumbar Interbody Fusion: A Computer-Based Simulation and Cadaveric Study
This study aims to investigate the feasibility of a novel lumbar approach named extraforaminal lumbar interbody fusion (ELIF), a newly emerging minimally invasive technique for treating degenerative lumbar disorders, using a digitalized simulation and a cadaveric study. The ELIF surgical procedure was simulated using the Mimics surgical simulator and included dissection of the superior articular process, dilation of the vertebral foramen, and placement of pedicle screws and a cage. ELIF anatomical measures were documented using a digitalized technique and subsequently validated on fresh cadavers. The use of the Mimics allowed for the vivid simulation of ELIF surgical procedures, while the cadaveric study proved the feasibility of this novel approach. ELIF had a relatively lateral access approach that was located 8–9 cm lateral to the median line with an access depth of approximately 9 cm through the intermuscular space. Dissection of the superior articular processes could fully expose the target intervertebral discs and facilitate a more inclined placement of the pedicle screws and cage with robust enhancement. According to the computer-based simulation and cadaveric study, it is feasible to perform ELIF. Further research including biomechanical study is needed to prove ELIF has a superior ability to preserve the posterior tension bands of the spinal column, with similar effects on spinal decompression, fixation, and fusion, and if it can enhance post-fusion spinal stability and expedites postoperative recovery.
- 19 February 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (5) , 974-984
Comparison of unilateral versus bilateral pedicle screw fixation in degenerative lumbar diseases: a meta-analysis
Traditionally, lumbar spinal surgery is performed with bilateral pedicle screw fixation to provide stability as the fusion heals. However, many studies have reported that unilateral pedicle screw fixation is as effective as bilateral constructs. To compare the clinical outcomes, complications, and surgical trauma between the two techniques for treatment of degenerative lumbar diseases, we conducted a meta-analysis. We searched MEDLINE, EMBASE, PubMed, Google Scholar, and Cochrane databases for relevant controlled studies up to August 2013 that compared unilateral with bilateral fixation for the treatment of degenerative lumbar diseases. We independently performed title/abstract screening and full-text screening. A random effects model was used for heterogeneous data; otherwise, a fixed effect model was used, pooling data using mean difference (MD) for continuous outcomes and odds ratio (OR) for dichotomous outcomes. A total of 12 articles (865 participants) were eligible. Overall, there were significant differences between the two groups for blood loss (MD = −171.73, 95 % CI = −281.70 to −61.76; p = 0.002), operation time (MD = −66.02, 95 % CI = −115.52 to −16.51; p = 0.009), and fusion rate (OR = 0.50, 95 % CI = 0.26–0.96; p = 0.004). However, there were no significant differences in hospital stay (MD = −4.44, 95 % CI = −13.37 to 4.50), ODI (MD = −0.09, 95 % CI = −0.59 to 0.42; p = 0.74), JOA (MD = 0.18, 95 % CI = −0.77 to 1.14; p = 0.71), VAS (MD = −0.04, 95 % CI = −0.16 to 0.08; p = 0.49), SF-36 (PF: MD = −1.11, 95 % CI = −4.38 to 2.17, p = 0.51; GH: MD = 1.22, 95 % CI = −2.17 to 4.60, p = 0.48; MH: MD = −0.22, 95 % CI = −3.83 to 3.38, p = 0.90) and complications (OR = 1.15, 95 % CI = 0.72–1.85; p = 0.56). This meta-analysis shows that there was significantly less blood loss in unilateral group and less operating time; however, the fusion rate was significantly higher in the bilateral group. The outcomes of hospital stay, ODI, JOA, VAS, SF-36 score, and complications are similar in the two groups.
- 19 February 2014
- Published by Springer Nature in European Spine Journal
- Vol. 23 (5) , 974-984
Comparison of unilateral versus bilateral pedicle screw fixation in degenerative lumbar diseases: a meta-analysis
Traditionally, lumbar spinal surgery is performed with bilateral pedicle screw fixation to provide stability as the fusion heals. However, many studies have reported that unilateral pedicle screw fixation is as effective as bilateral constructs. To compare the clinical outcomes, complications, and surgical trauma between the two techniques for treatment of degenerative lumbar diseases, we conducted a meta-analysis. We searched MEDLINE, EMBASE, PubMed, Google Scholar, and Cochrane databases for relevant controlled studies up to August 2013 that compared unilateral with bilateral fixation for the treatment of degenerative lumbar diseases. We independently performed title/abstract screening and full-text screening. A random effects model was used for heterogeneous data; otherwise, a fixed effect model was used, pooling data using mean difference (MD) for continuous outcomes and odds ratio (OR) for dichotomous outcomes. A total of 12 articles (865 participants) were eligible. Overall, there were significant differences between the two groups for blood loss (MD = −171.73, 95 % CI = −281.70 to −61.76; p = 0.002), operation time (MD = −66.02, 95 % CI = −115.52 to −16.51; p = 0.009), and fusion rate (OR = 0.50, 95 % CI = 0.26–0.96; p = 0.004). However, there were no significant differences in hospital stay (MD = −4.44, 95 % CI = −13.37 to 4.50), ODI (MD = −0.09, 95 % CI = −0.59 to 0.42; p = 0.74), JOA (MD = 0.18, 95 % CI = −0.77 to 1.14; p = 0.71), VAS (MD = −0.04, 95 % CI = −0.16 to 0.08; p = 0.49), SF-36 (PF: MD = −1.11, 95 % CI = −4.38 to 2.17, p = 0.51; GH: MD = 1.22, 95 % CI = −2.17 to 4.60, p = 0.48; MH: MD = −0.22, 95 % CI = −3.83 to 3.38, p = 0.90) and complications (OR = 1.15, 95 % CI = 0.72–1.85; p = 0.56). This meta-analysis shows that there was significantly less blood loss in unilateral group and less operating time; however, the fusion rate was significantly higher in the bilateral group. The outcomes of hospital stay, ODI, JOA, VAS, SF-36 score, and complications are similar in the two groups.
- Open Access
- 12 November 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (11) , e79552
Partial Recovery of Respiratory Function and Diaphragm Reinnervation following Unilateral Vagus Nerve to Phrenic Nerve Anastomosis in Rabbits
Respiratory dysfunction is the leading cause of mortality following upper cervical spinal cord injury (SCI). Reinnervation of the paralyzed diaphragm via an anastomosis between phrenic nerve and a donor nerve is a potential strategy to mitigate ventilatory deficits. In this study, anastomosis of vagus nerve (VN) to phrenic nerve (PN) in rabbits was performed to assess the potential capacity of the VN to compensate for lost PN inputs. At first, we compared spontaneous discharge pattern, nerve thickness and number of motor fibers between these nerves. The PN exhibited a highly rhythmic discharge while the VN exhibited a variable frequency discharge pattern. The rabbit VN had fewer motor axons (105.3±12.1 vs. 268.1±15.4). Nerve conduction and respiratory function were measured 20 weeks after left PN transection with or without left VN-PN anastomosis. Compared to rabbits subjected to unilateral phrenicotomy without VN-PN anastomosis, diaphragm muscle action potential (AP) amplitude was improved by 292%, distal latency by 695%, peak inspiratory flow (PIF) by 22.6%, peak expiratory flow (PRF) by 36.4%, and tidal volume by 21.8% in the anastomosis group. However, PIF recovery was only 28.0%, PEF 28.2%, and tidal volume 31.2% of Control. Our results suggested that VN-PN anastomosis is a promising therapeutic strategy for partial restoration of diaphragm reinnervation, but further modification and improvements are necessary to realize the full potential of this technique.
- 12 November 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (11) , e79552
Open AccessPartial Recovery of Respiratory Function and Diaphragm Reinnervation following Unilateral Vagus Nerve to Phrenic Nerve Anastomosis in Rabbits
Respiratory dysfunction is the leading cause of mortality following upper cervical spinal cord injury (SCI). Reinnervation of the paralyzed diaphragm via an anastomosis between phrenic nerve and a donor nerve is a potential strategy to mitigate ventilatory deficits. In this study, anastomosis of vagus nerve (VN) to phrenic nerve (PN) in rabbits was performed to assess the potential capacity of the VN to compensate for lost PN inputs. At first, we compared spontaneous discharge pattern, nerve thickness and number of motor fibers between these nerves. The PN exhibited a highly rhythmic discharge while the VN exhibited a variable frequency discharge pattern. The rabbit VN had fewer motor axons (105.3±12.1 vs. 268.1±15.4). Nerve conduction and respiratory function were measured 20 weeks after left PN transection with or without left VN-PN anastomosis. Compared to rabbits subjected to unilateral phrenicotomy without VN-PN anastomosis, diaphragm muscle action potential (AP) amplitude was improved by 292%, distal latency by 695%, peak inspiratory flow (PIF) by 22.6%, peak expiratory flow (PRF) by 36.4%, and tidal volume by 21.8% in the anastomosis group. However, PIF recovery was only 28.0%, PEF 28.2%, and tidal volume 31.2% of Control. Our results suggested that VN-PN anastomosis is a promising therapeutic strategy for partial restoration of diaphragm reinnervation, but further modification and improvements are necessary to realize the full potential of this technique.
- 20 November 2010
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 30 (11) , 1201-1205
Anterior cervical decompression technique via intervertebral space under microscope
Objective To discuss the technique of the anterior cervical decompression via intervertebral space under microscope.Methods A total of 271 patients with cervical disc herniation underwent anterior microsurgical decompression and intervertebral fusion from Jun.2000.6 to Dec.2005.The patients included 178 cases with single level herniation,71 with double level ones,and 22 with three level ones.MRI images showed slight or medium anterior compression with slight abnormal changes within spinal cord in all cases.The main equipment included operation microscope for neurosurgery and high speed bur.The annular fibrous and osteophytes were removed by high speed bur to expose and clean the degenerative nucleus pulpous.We lifted the posterior longitudinal ligament(PLL) with tension using a hook-like stripper and cut it;then the residual PLL and posterior bony edges were removed.Results There were no severe complications such as injuries of the spinal cord,nerve root or blood vessels.The average intraoperative blood loss was(126 ±29.4) ml and the mean operative time was(62 ±12.4) min.The average time for the patients to get off bed was(1.8 ±0.4) days.The nerve functions were improved in all patients after operation,with the excellent nerve function found in 69 cases,good in 157 cases,fair in 27 cases,and poor in 18 cases according to JOA scores.Conclusion Anterior cervical decompression via intervertebral space under microscope is suitable for treatment of pathological changes of the intervertebral space;delicate manipulation under microscope and high speed bur can contribute to a successful operation;and the anatomy of intervertebral space is more suitable for the biomechanics of the cervical vertebrate.
- 20 November 2010
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 30 (11) , 1201-1205
Anterior cervical decompression technique via intervertebral space under microscope
Objective To discuss the technique of the anterior cervical decompression via intervertebral space under microscope.Methods A total of 271 patients with cervical disc herniation underwent anterior microsurgical decompression and intervertebral fusion from Jun.2000.6 to Dec.2005.The patients included 178 cases with single level herniation,71 with double level ones,and 22 with three level ones.MRI images showed slight or medium anterior compression with slight abnormal changes within spinal cord in all cases.The main equipment included operation microscope for neurosurgery and high speed bur.The annular fibrous and osteophytes were removed by high speed bur to expose and clean the degenerative nucleus pulpous.We lifted the posterior longitudinal ligament(PLL) with tension using a hook-like stripper and cut it;then the residual PLL and posterior bony edges were removed.Results There were no severe complications such as injuries of the spinal cord,nerve root or blood vessels.The average intraoperative blood loss was(126 ±29.4) ml and the mean operative time was(62 ±12.4) min.The average time for the patients to get off bed was(1.8 ±0.4) days.The nerve functions were improved in all patients after operation,with the excellent nerve function found in 69 cases,good in 157 cases,fair in 27 cases,and poor in 18 cases according to JOA scores.Conclusion Anterior cervical decompression via intervertebral space under microscope is suitable for treatment of pathological changes of the intervertebral space;delicate manipulation under microscope and high speed bur can contribute to a successful operation;and the anatomy of intervertebral space is more suitable for the biomechanics of the cervical vertebrate.