John E. Iyaniwura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
John E. Iyaniwura has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Hanif M. Ladak
Department of Otolaryngology-Head and Neck Surgery, Western University, London, Canada
1 shared publication - Mai Elfarnawany
Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
1 shared publication - Sumit Kishore Agrawal
Department of Medical Biophysics, Western University, London, ON, Canada
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 47 (1) , 5
An automated A-value measurement tool for accurate cochlear duct length estimation
Background: There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Method: Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. Results: The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values ( r = 0.70, p < 0.01 and r = 0.69, p < 0.01, respectively). Conclusion: An automated A-value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit cochlear implant recipients in the future.
- 1 January 2018
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 47 (1) , 5
Open AccessAn automated A-value measurement tool for accurate cochlear duct length estimation
Background: There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Method: Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. Results: The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values ( r = 0.70, p < 0.01 and r = 0.69, p < 0.01, respectively). Conclusion: An automated A-value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit cochlear implant recipients in the future.