Pimpet Sratong-On
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pimpet Sratong-On has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Hideki Hosoda
Laboratory for Future Interdisciplinary Research of Science and Technology & Materials and Structures Laboratory, Institute of Integrated Research (IIR), Institute of Science Tokyo, Yokohama 226-8501, Japan
4 shared publications- Volodymyr A. Chernenko
BCMaterials, Basque Center for Materials, Applications and Nanostructures, EHU Science Park, Leioa, Spain
4 shared publications - Wan-Ting Chiu
School of Materials and Chemical Technology
4 shared publications Masaki Tahara
Laboratory for Future Interdisciplinary Research of Science and Technology & Materials and Structures Laboratory, Institute of Integrated Research (IIR), Institute of Science Tokyo, Yokohama 226-8501, Japan
3 shared publications- Hideki Hosoda
Institute of Innovative Research (IIR), Tokyo Institute of Technology, Yokohama, Japan
2 shared publications - Sawanya Suwannawong
Thai-Nichi Institute of Technology
2 shared publications
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (10) , 105001
Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate
Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate, Sratong-on, Pimpet, Sukjai, Onanong, Suwannawong, Sawanya, Foo, Hui Lin, Lim, Kaylen, Lee, Chuen Kum, Sasaki, Kazuhiko Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate, Sratong-on, Pimpet, Sukjai, Onanong, Suwannawong, Sawanya, Foo, Hui Lin, Lim, Kaylen, Lee, Chuen Kum, Sasaki, Kazuhiko
- 1 October 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (10) , 105001
Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate
Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate, Sratong-on, Pimpet, Sukjai, Onanong, Suwannawong, Sawanya, Foo, Hui Lin, Lim, Kaylen, Lee, Chuen Kum, Sasaki, Kazuhiko Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate, Sratong-on, Pimpet, Sukjai, Onanong, Suwannawong, Sawanya, Foo, Hui Lin, Lim, Kaylen, Lee, Chuen Kum, Sasaki, Kazuhiko
- 6 September 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 239 (9) , 934-951
Structural integrity and failure of transfemoral prosthetic socket fabricated using carbon prepreg technique: Influence of fiber orientation and curing conditions
This study provides valuable guidance for simplifying fabrication procedures and enhancing the structural integrity and safety of carbon fiber (CF) laminate transfemoral (TF) prosthetic sockets. While the high specific strength of CF laminate sockets offers advantages over conventional plastics, essential production data—their orientation-dependent strength and optimal cure conditions—are lacking, often requiring complex, costly cure cycles. This study investigated (i) the influence of fiber orientation on TF prosthetic CF socket strength via finite element analysis (FEA) during standing, and (ii) optimal single-step Vacuum-Bag-Only (VBO) cure conditions for prepreg in a low-cost conventional oven. Three distinct CF laminates ((45/−45/45/−45), (0/90/0/90), (0/45/−45/90)) were implemented in TF socket finite element (FE) models. Tensile and flexural tests validated FE results and assessed laminate failure modes. Differential Scanning Calorimetry (DSC) investigated cure temperatures, while surface voids were inspected to identify optimal single-step cure conditions. A 1-h isothermal cure at 90°C facilitated resin flow and yielded minimal surface voids. FEA revealed ply orientations insignificantly influenced residual limb pressure. Most plies in the (45/−45/45/−45) CF laminate favorably aligned with oblique deformation for TF socket stabilization during standing. Experimentally, it exhibited the lowest stiffness (10.86 GPa) and strength (161.49 MPa). Nevertheless, its strength is superior to other socket materials and enhances safety through clear pre-fracture signs from ductile failure. Maximum pressure of up to 32.2 kPa at the medial-distal site during standing was insufficient to cause discomfort. These findings provide guidelines for high-quality TF sockets using prepreg by simplifying the fabrication process.
- 6 September 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 239 (9) , 934-951
Structural integrity and failure of transfemoral prosthetic socket fabricated using carbon prepreg technique: Influence of fiber orientation and curing conditions
This study provides valuable guidance for simplifying fabrication procedures and enhancing the structural integrity and safety of carbon fiber (CF) laminate transfemoral (TF) prosthetic sockets. While the high specific strength of CF laminate sockets offers advantages over conventional plastics, essential production data—their orientation-dependent strength and optimal cure conditions—are lacking, often requiring complex, costly cure cycles. This study investigated (i) the influence of fiber orientation on TF prosthetic CF socket strength via finite element analysis (FEA) during standing, and (ii) optimal single-step Vacuum-Bag-Only (VBO) cure conditions for prepreg in a low-cost conventional oven. Three distinct CF laminates ((45/−45/45/−45), (0/90/0/90), (0/45/−45/90)) were implemented in TF socket finite element (FE) models. Tensile and flexural tests validated FE results and assessed laminate failure modes. Differential Scanning Calorimetry (DSC) investigated cure temperatures, while surface voids were inspected to identify optimal single-step cure conditions. A 1-h isothermal cure at 90°C facilitated resin flow and yielded minimal surface voids. FEA revealed ply orientations insignificantly influenced residual limb pressure. Most plies in the (45/−45/45/−45) CF laminate favorably aligned with oblique deformation for TF socket stabilization during standing. Experimentally, it exhibited the lowest stiffness (10.86 GPa) and strength (161.49 MPa). Nevertheless, its strength is superior to other socket materials and enhances safety through clear pre-fracture signs from ductile failure. Maximum pressure of up to 32.2 kPa at the medial-distal site during standing was insufficient to cause discomfort. These findings provide guidelines for high-quality TF sockets using prepreg by simplifying the fabrication process.
- 27 November 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (12) , 125035
Influence of superelastic training and huge strains on field-induced martensitic variants reorientation in particulate Ni–Mn–Ga/silicone composite
Ni–Mn–Ga ferromagnetic shape memory alloys (FSMAs) are promising materials for actuator and transducer devices. Their intrinsic brittleness and high fabrication cost in the bulk form are issues to be solved. One of the solutions is a development of composites comprising these materials as a filler component whereby representing an emerging research field in the FSMAs. To address the improvement and stability challenges of the magnetic field-induced martensitic variant reorientation (MVR) characteristics of the particles in the previously elaborated ‘Ni–Mn–Ga single-crystalline particles/silicone rubber’ composites and to unveil new aspects of their functional behaviors, in the present work, we have investigated MVR characteristics as a function of compression cycling and under huge in-situ opposing contractions. It was found that after cycling with the 30% of compressive strain along the particle chains, the value of switching magnetic field needed to start MVR events was notably reduced, whereas it was almost intact when in-situ measured under the same compression level. In-situ measurements of the ‘magnetization versus magnetic field’ curves of the composite squeezed by 50% or 70% did not show MVR blocking. Instead, they revealed both a drastic decrease of the MVR switching field and narrowing of the MVR interval caused by the barreling effect. The results can be useful for the development of novel types of actuators and transducers.
- 27 November 2024
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 33 (12) , 125035
Influence of superelastic training and huge strains on field-induced martensitic variants reorientation in particulate Ni–Mn–Ga/silicone composite
Ni–Mn–Ga ferromagnetic shape memory alloys (FSMAs) are promising materials for actuator and transducer devices. Their intrinsic brittleness and high fabrication cost in the bulk form are issues to be solved. One of the solutions is a development of composites comprising these materials as a filler component whereby representing an emerging research field in the FSMAs. To address the improvement and stability challenges of the magnetic field-induced martensitic variant reorientation (MVR) characteristics of the particles in the previously elaborated ‘Ni–Mn–Ga single-crystalline particles/silicone rubber’ composites and to unveil new aspects of their functional behaviors, in the present work, we have investigated MVR characteristics as a function of compression cycling and under huge in-situ opposing contractions. It was found that after cycling with the 30% of compressive strain along the particle chains, the value of switching magnetic field needed to start MVR events was notably reduced, whereas it was almost intact when in-situ measured under the same compression level. In-situ measurements of the ‘magnetization versus magnetic field’ curves of the composite squeezed by 50% or 70% did not show MVR blocking. Instead, they revealed both a drastic decrease of the MVR switching field and narrowing of the MVR interval caused by the barreling effect. The results can be useful for the development of novel types of actuators and transducers.
- 5 January 2023
- Published by Elsevier in Scripta Materialia
- Vol. 227
Aging behavior of Ni-Mn-Ga/silicone particulate composites exhibiting large recoverable magnetostrain
- 5 January 2023
- Published by Elsevier in Scripta Materialia
- Vol. 227
Aging behavior of Ni-Mn-Ga/silicone particulate composites exhibiting large recoverable magnetostrain
- Open Access
- 30 December 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 23, 131-142
Bi-doping engineering of Ni-Mn-Ga polycrystals and resulting grain particles for smart Ni-Mn-Ga/polymer composites
- 30 December 2022
- Published by Elsevier in Journal of Materials Research and Technology
- Vol. 23, 131-142
Open AccessBi-doping engineering of Ni-Mn-Ga polycrystals and resulting grain particles for smart Ni-Mn-Ga/polymer composites
- 1 January 2022
- Published by Elsevier in Scripta Materialia
- Vol. 207
Large magnetostrains of Ni-Mn-Ga/silicone composite containing system of oriented 5M and 7M martensitic particles
- 1 January 2022
- Published by Elsevier in Scripta Materialia
- Vol. 207
Large magnetostrains of Ni-Mn-Ga/silicone composite containing system of oriented 5M and 7M martensitic particles
- Open Access
- 5 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 3443
Magnetic field-induced rubber-like behavior in Ni-Mn-Ga particles/polymer composite
Single crystalline Ni-Mn-Ga is well known as a prototype ferromagnetic shape memory alloy (FSMA) exhibiting a giant magnetic field-induced strain (MFIS), up to 12%, due to the magnetically driven twin boundary rearrangement. The large stroke and fast magnetomechanical response make it important for actuators and sensors. Polycrystalline Ni-Mn-Ga is inexpensive and technologically easy accessible, but constrains from the grain boundaries inhibit the twin boundary motion, whereby a very low MFIS is observed. Here, we have shown for the first time that a polycrystalline Ni-Mn-Ga can be split into the magnetostrain-active single grains which, being specially assembled in a silicone polymer matrix, caused large and fully reversible MFIS of the resulting composite. We termed the unique reversibility of a large MFIS of the composite as the magnetic field-induced rubber-like behavior. The magnetostrain of individual particles was explored by the X-ray μCT 3D imaging. The results suggest novel solutions for development of the low cost magnetic actuators and sensors for haptic applications.
- 5 March 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 3443
Open AccessMagnetic field-induced rubber-like behavior in Ni-Mn-Ga particles/polymer composite
Single crystalline Ni-Mn-Ga is well known as a prototype ferromagnetic shape memory alloy (FSMA) exhibiting a giant magnetic field-induced strain (MFIS), up to 12%, due to the magnetically driven twin boundary rearrangement. The large stroke and fast magnetomechanical response make it important for actuators and sensors. Polycrystalline Ni-Mn-Ga is inexpensive and technologically easy accessible, but constrains from the grain boundaries inhibit the twin boundary motion, whereby a very low MFIS is observed. Here, we have shown for the first time that a polycrystalline Ni-Mn-Ga can be split into the magnetostrain-active single grains which, being specially assembled in a silicone polymer matrix, caused large and fully reversible MFIS of the resulting composite. We termed the unique reversibility of a large MFIS of the composite as the magnetic field-induced rubber-like behavior. The magnetostrain of individual particles was explored by the X-ray μCT 3D imaging. The results suggest novel solutions for development of the low cost magnetic actuators and sensors for haptic applications.
- 25 July 2018
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 27 (8) , 085024
Compression response of Ni–Mn–Ga/silicone composite and study of three-dimensional deformation of particles
Ni–Mn–Ga particles/silicone composite was fabricated for a mechanical investigation. The characteristic twinning structure of particles and soft enough matrix provide the conditions enabling the possibility for particles to deform by the twin boundaries motion mechanism under applied stress and/or magnetic field. On the macroscopic scale, the large hysteretic loops in the stress–strain curves for composite evidence about its high energy absorption capability. On the microscopic scale, the in situ compression test was performed using an x-ray micro-computed tomography to study the individual deformation of particles. The strain behavior of individual particles in the three different configuration of groups was disclosed as a function of the compression degree of composite showing large reversible deformation of particles, signature of the twin structure rearrangement. The unusual drop of particles strains at very high compression degrees of composite is explained in terms of the non-uniform stress field in polymer produced by the neighbor particles interactions affected by barreling. The obtained results support the reason that the particles in composite should be arranged in single chains to avoid their interaction which is a way to improve the composite performance in the mechanical damping and magnetic actuator applications.
- 25 July 2018
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 27 (8) , 085024
Compression response of Ni–Mn–Ga/silicone composite and study of three-dimensional deformation of particles
Ni–Mn–Ga particles/silicone composite was fabricated for a mechanical investigation. The characteristic twinning structure of particles and soft enough matrix provide the conditions enabling the possibility for particles to deform by the twin boundaries motion mechanism under applied stress and/or magnetic field. On the macroscopic scale, the large hysteretic loops in the stress–strain curves for composite evidence about its high energy absorption capability. On the microscopic scale, the in situ compression test was performed using an x-ray micro-computed tomography to study the individual deformation of particles. The strain behavior of individual particles in the three different configuration of groups was disclosed as a function of the compression degree of composite showing large reversible deformation of particles, signature of the twin structure rearrangement. The unusual drop of particles strains at very high compression degrees of composite is explained in terms of the non-uniform stress field in polymer produced by the neighbor particles interactions affected by barreling. The obtained results support the reason that the particles in composite should be arranged in single chains to avoid their interaction which is a way to improve the composite performance in the mechanical damping and magnetic actuator applications.