ATAntoine Tijou

Antoine Tijou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Antoine Tijou has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Charles-Henri Flouzat-Lachaniette

    Department of Orthopaedic Surgery, Hôpital Henri Mondor, AP-HP, Université Paris Est Créteil (UPEC), 94010, Creteil, France; Cell and tissue engineering for musculoskeletal disorders (Group 5) / Biology of the NeuroMuscular System (INSERM Team 10) / Institut Mondor de Recherche Biomédicale, U955 INSERM-UPEC, Créteil, France

    1 shared publication
  • Giuseppe Rosi

    Laboratoire Modelisation et Simulation Multi Echelle, Universite Paris Est Creteil, MSME UMR 8208 CNRS, 61 Avenue du General de Gaulle, 94010 Creteil, France

    1 shared publication
  • Guillaume Haiat

    CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, Creteil, France

    1 shared publication
  • Philippe Hernigou

    Department of orthopedic surgery, APHP, Henri Mondor teaching hospital, Creteil, France

    1 shared publication

Latest Publications

  • Open Access

    Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors

    by Antoine Tijou, Giuseppe Rosi, Philippe Hernigou, Charles-Henri Flouzat-Lachaniette, Guillaume Haïat

    The acetabular cup (AC) implant stability is determinant for the success of cementless hip arthroplasty. A method based on the analysis of the impact force applied during the press-fit insertion of the AC implant using a hammer instrumented with a force sensor was developed to assess the AC implant stability. The aim of the present study was to investigate the performance of a method using a hammer equipped with strain sensors to retrieve the AC implant stability. Different AC implants were inserted in five bovine samples with different stability conditions leading to 57 configurations. The AC implant was impacted 16 times by the two hammers consecutively. For each impact; an indicator IS (respectively IF) determined by analyzing the time variation of the signal corresponding to the averaged strain (respectively force) obtained with the stress (respectively strain) hammer was calculated. The pull-out force F was measured for each configuration. F was significantly correlated with IS (R2 = 0.79) and IF (R2 = 0.80). The present method has the advantage of not modifying the shape of the hammer that can be sterilized easily. This study opens new paths towards the development of a decision support system to assess the AC implant stability.